Loading...
HomeMy WebLinkAboutMISC EMAILChief Building Official St Lucie County Building Department 2300 Virginia Avenue Ft Pierce, FL 34982 Reference: Hibiscus by the Sea Condo 3880 N. Highway AIA Ft. Pierce, FL 34949 Subject: New Roof Material — Gazebo Building August 15, 2017 SCANNED BY St. -Lucie County The roofer may install Advanced Aluminum Permatile Panel Aluminum 0.030 roof panels on the existing one story (5/12 pitch) pool bldg. per the attached FL- 1763-R2 Florida Test Report. #9-15 X 2-1/2" Woodbinder HSS 304 SS (w/with sealing washers) fasteners are to be installed in a 7", 7", 7", 7" pattern @ 12" spacing per Table "A" in all zones. The required applied uplifts in their appropriate zones for a mean roof height of < 15 feet, in exposure "D" during a 170 mph.1,,132 mph �d wind event are as follows: Zone #1 (45 psf) Zone #2 (-75 psf) Zone #3 (-113 psf) The product, installed per the aforementioned pattern / spacing, has been tested to provide a maximum total uplift design pressure of 153.5 psf, clearly exceeding the requirements for all three zones. If you have any questions, please call me at your convenience. Thank you. Dr. Ernest A. Kuonen, PE 022920 President, The Erning Corporation CA-8327 228 Moccasin Trail West Jupiter, FL 33458