HomeMy WebLinkAboutPRODUCT APPROVALcS e-�
� PWfioA ovanp7anuroP �, ca -..
Business O.rofessional Regulation � -
.. _ . s.f '.obPll�ilgr`'e .. oeow.P,!srs.:dd—.-.wf. ypli
j,� ` Product Approval
l:. "j USER: Public User
Honda
�g
Product Avvroval Menu > Product or AovncadOn 5earchAovlicattOn Search > Application Ms[ > AppIIOUOn aetall
FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
SCANNED
BY
St. Lucie County
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed
the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
FL1763-R2
Revision
2014
Approved THESE PUNS AND ALL PROQOKI) WORK
ARE SUBJECT TO ANY CORRECTIONS
-REQUIRED BY FIELD INSPECTORS THAT
. MAY EE NECESSARY IN ORDER TO
Advanced Aluminum COMPLY WITH ALL APPLICABLE CODES.
2934 Parkway Street
Lakeland, FL 33811
(863)648-5787
advancedaluminum@msn.com
James Smith
advancedaluminum@msn.com
Roofing
Metal Roofing
ST. LUCIE COUNTY
BUILDING DIVISION
REVIEWED
FOR COMPLIANCE;
REVIEWED BY G
DATE
MUST BE KEPT ON OB OR
NO INSPECTION WIYL BE MADE
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Terrence E. Wolfe CORO'MUD
P,gTIupRSOnATTACHMEWS
PE-44923 MRSPOHS16101 OFTHE
Architectural Testing, Inc. ow
'y•,�' �,�yy1��1,y}`�yi�',1-y �lt
12/31/2018 �'a%„"I MMIFaFdY1/IlY
Locke Bowden
R Validation Checklist - Hardcopy, Received
FL1763 R2 COI Letter of Certification - Secured.odf
Standard
year
TAS 100
_ 1995
TAS 125
2003
UL 1897
2004
UL 580
2006
htlps:lAvww.floddabuilding.org/pr/pr app_dU.aspx7param=wG[VXQwtDgvFGYZsirZFRIYlNtr7Z6JQfrODQVAXOOg%3d 1/2
712Jr2017 r
Product Approval Method
Florida Building Code Online
Method 1 Option D
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
(16/18/2015
06/19/2015
06/28/2015
,
08/18/2015FILL
'y
FL #
Model, Number or Name
Description
1763.1
Advantage Panel 26 Ga.
26 Ga. Advantage Roof Panel over Plywood
Limits of Use
Installation Instructions
Approved for use In HVHZ.• Yes
FL1763 R2 li 26 Ga Advantage Roof Panel over Plywood
HVHZ - Secured.Ddf
Verified By: Terrence E. Wolfe, P.E. 44923
j Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-123.SPSF
Created by Independent Third Party: Yes
Other: -82.25 psf at 9'-9"-9"-9" Fastener Pattern at 24' O.C.
Fastener Sparing. -123.5 psf at 9"-9"-9'-9" Fastener Pattern at
Evaluation Reports
FL1763 R2 AE 26 Ga Advantage Roof Panel over Plywood
HVHZ - Secured.odf
12" O.C. Fastener Spacing. Install per manufadu s details.
For use in HVHZ Zones.
Created by Independent Third Party: Yes
1763.2
flPermatile Panel 26 Ga.
26 Ga. Permatile Roof Panel over Vz" Plywood
Limits of Use
Approved for use In HVHZ: Yes
Installation Instructions
FL1763 R2 iI 26 Ga Permatile Roof Panel over Plywood
HVHZ - Secured.pdf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Terrence E. Wolfe, P.E. 44923
Design Pressure: +N/A/-161.0PSF
Created by Independent Third Party: Yes
Other: -74.8 psf at 14"-14" Fastener Pattern at 14" O.C.
Fastener Spacing. -161.0 psf at 7"-7"-7"-7" Fastener Pattern at
Evaluation Reports
FL1763 R2 AE 26 Ga Permatile Roof Panel over Plywood
HVHZ - Secured.odf
14" O.C. Fastener Spacing. Install per manufacturer's details.
For use in HVHZ Zones.
Created by Independent Third Party: Yes
1763.3 Permatle Panel Aluminum 0.030"
030' Aluminum Permatile Roof Panel over Plywood
Limits of se
Approved a in HVHZ: Yes
14tallation Instructions
17 R2 II u in= Permatile Roof Panel over Plywood
HVHZ - Secured ndf
Verified By: Terrence E. Wolfe, P.E. 44923
Approved for use ou i e
Impact Resistant: N/A
Design Pressure: +N/A/-153.Spsf
Created by Independent Third Party: Yes
Other: -104.8 psf at 14"-14' Fastener Pattern at 12' O.C.
Evaluation Reports
Fastener Spacing. -153.5 psf at 70-7"-7"-7' Fastener Pattern at
FL1763 R2 AE Aluminum Permatile Roof Panel over Plywood
HVHZ - Secured.odf
12" O.C. Fastener Spacing. Install per manufacturer's details.
For use in HVHZ Zones.
I Created by Independent Third Party: Yes
each Crag[
Contact Us :: 2601 BI ' Store Road. Tall h Fl, 32399 Ph.... 850487-1824
The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Atcessibim, Statement :: Refund Statement
Under Flodda law, emali addresses are public records. If you do not want your e-mall acidness releasM in respom e to a pubdo-remrds request, do not send electrum,
mall to MIS entity. Instead, contact the office by phone or by badillonal mad. If you have any questions, please contact 850A87.1395.'Pur uent to Section
455.275(1), Florida Statutes, effective OCMber 1, 2012, licensees licensed under chapter 455, F.S. must provide the Department with an =all address If they have
one. The enrolls provided maybe used for official communication with the licensee. However lamed addresses are pubdc record. If you do noc wish tc Supply a Peracnel
address, please provide the Department with an anal] address which can be made available to Me public. To deterinlne if you are a licansoe under chapter 455, F.S.,
please dirk ere.
Product Approval Acoeptst
st;cu_r�LyAlrrx�cs
https:tlw .floridabuilding.org/pr/pr app dg.aspa?pa m�GEVXQwtDgvFGYZsjrZFR1YINbrZ6JQfE00OVAXOOg%3d 212
rEngineering Testing lnc.n
93blcwood Drive
H.blc,TX 77338
Product Evaluation Report
ADVANCED ALUMINUM
Aluminum Permatile Roof Panel over Plywood
Florida Product Approval # 1763.3
Florida Building Code 2014
Per Rule 61G20-3
Method: I-D
Category: Roofing
Subcategory: Metal Roofing
Compliance Method: 61G203.005(1)(d)
HVH2
Product Manufacturer.
Advanced Aluminum
2934 Parkway Street
Lakeland, Florida 33831
Engineer Evaluator. HLE
(;0mY
Terrence E. Wolfe, P.E. # 44923
Florida Evaluation ANE ID:1920
Validator:
Locke Bowden, P.E., FL #49704
9450 Alysbury Place
Montgomery, AL 36117
Contents:
Evaluation Report Pages l-4
111111 a r rye',
C E' F-
O
r
STA7E OF
smO0orrArma i�, d .. �V ���
FL# 1763.3
June 18, 2015
l`
Force Engineering & Testing Inc.
19530 Rumblewood Drive
Hu.-uble,TX 77338
Compliance Statement: The product as described in this report has demonstrated compliance with the
Florida Building Code 2014, Sections 1504.3.2, 1518.9, 1523.6.5.2.4.
Product Description: Aluminum Permatile Roof Panel, 0.030" Aluminum, 28" Coverage, through
fastened roof panel over APA Plywood decking. Non -Structural Application.
Panel Material/Standards: Material: 0.030" Aluminum, ASTM B209 conforming to Florida Building Code
2014 Section 1507.4.3.
Panel Coating (Optional): Fluropon® Coating by Valspar Corp.
Yield Strength: Min.25.Oksi
Corrosion Resistance: Panel Material shall comply with Florida Building Code
2014, Section 1507.4.3
Panel Dimension(s): Thickness: 0.030" min.
Coverage: 28" maximum coverage
Rib Height: 1 Y" tall major rib at 7" O.C.
Panel Fastener. #9-15 x 2-1/2" Woodbinder HSS 304 SS with sealing washing or approved equal
Y<" minimum penetration through plywood
Corrosion Resistance: Per Florida Building Code 2014, Section 1506.6, 1517.6.
Substrate Description: 1) For HVHZ construction, use 19/32" or greater APA Rated plywood or wood
plank. In reroofing applications where the deck is less than 19/32" thick (min.
15/32") the attachment of the decking in no case shall be less than 8D annual
ring shank nails at 6" O.C. Design of plywood and plywood supports are outside
the scope of this evaluation. Substrate must be designed in accordance w/
Florida Building Code 2014.
2) For Non-HVHZ applications, use min.15/32" thick, APA Rated plywood over
supports at maximum 24" O.C. Design of plywood and plywood supports are
outside the scope of this evaluation. Substrate must be designed in accordance
w/ Florida Building Code 2014.
' 7 'tic' zsak IMF
�
FL# 17633
'%1&HNr11
CE iYSF
No. 40
STATE OF ; ¢ �'
se.mmofs ��� F • O RI
June 18, 2015
Design Uplift Pressures:
,-fr7 rForcengineering 8c Testing Inc.
19530 R rnblmood Drive
Humblc.TX 77338
Table"A"
Maximum Total Uplift Design Pressure:
104.8 psf
Fastener Pattern:
14"-14"
Fastener Spa6ng:
12" O.C.
'Design Pressure includes a Safety Factor= 2.0.
Code Compliance: The product described herein has demonstrated compliance with
The Florida Building Code 2014, Section 1504.3.2,1518.9, 1523.6.5.2.4.
Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load
requirements of the Florida Building Code 2014, as relates to Rule 61G20-3.
Performance Standards: The product described herein has demonstrated compliance with:
• TAS 125-03
• UL 580-06 -Testfor Uplift Resistance of Roof Assemblies
• UL 1897-04- Uplift Test for Roof Covering Systems
• TA5100-95 -Test Procedure for Wind and Wind Driven Rain Resistance
of Discontinuous Roof Systems
• TAS 110.00- Accelerated Weathering / Salt Spray
Reference Data: 1. TA5125-03: UL 580.06 / 1897-04 Uplift Test
Force Engineering & Testing, Inc (FBC Organization # TST-5328)
Report No. 343-0150T-13A-C
2. TAS 100-95
Farabaugh Engineering & Testing, Inc. (FBC Organization # TST-1654)
Report No. T225-13
3. TAS 11D-00: Fluropon° mating by Valspar Corporation
A) ASTM G 155 by PRI Asphalt Technologies
B) ASTM B 117 by PRI Asphalt Technologies
4. Certificate of Independence
By Terrence E. Wolfe, P.E. (No. 44923) @ Force Engineering & Testing, Inc
(FBC Organization # ANE ID:1920)
NSErEtt�I
t• c E NSF<��
q • STATE OF ; c
�.•��` AL O R19 A �v
i/�M
FL# 17633
June 18, 2015
V,
Force Engineering &Testing Inc.
19530 Ramblewood Drive
rinmblaTX 77338
Quality Assurance Entity:
The manufacturer has established compliance of roof panel products in
accordance with the Florida Building Code and Rule 611320-3.005 (3) for
manufacturing under a quality assurance program audited by an approved
quality assurance entity.
Minimum Slope Range:
2:12. Minimum Slope shall comply with Florida Building Code 2014, including
Section 2515.2.2 and in accordance with Manufacturers recommendations. For
slopes less than 3:12, lap sealant must be used in the panel side laps.
Installation:
Install per manufacturer's recommended details and RAS 133.
Underlayment:
Per Manufacturer's installation guidelines per Florida Building Code 2014.
Fire Barrier:
Any approved fire barrier having a current NOA. Refer to a current fire directory
listing for fire ratings of this roofing system assembly as well as the location of
the fire barrier within the assembly. Fire classification is not part of this
acceptance.
Shear Diaphragm:
Shear diaphragm values are outside the scope of this report
Design Procedure:
Based on the dimensions of the structure, appropriate wind loads are
determined using Chapter 16 of the Florida Building Code 2014 for roof cladding
wind loads. These component wind loads for roof cladding are compared to the
allowable pressure listed above. Support framing must be in compliance with
Florida Building Code 2014 Chapter 22 for steel, Chapter 23 for wood and
Chapter 16 for structural loading.
CENyFC^`�:
STATE OF
?'. 4
��t` ALORI9A.•�+'�
mewrmem � 6 • . V1 ��
oxO6im ,��� it�N IItt1 10%
FL# 1763.3
June 18, 2015
FASTENER PATTERN TYPE A. AT 12" O.C.
I la I le
#9-15 x 2-1/2" WOODBINDER HSS 304 SS W/ WASHER
FASTENER PATTERN TYPE B. AT 12" O.C.
7' _I_ r _I, r
#9-15 x 2-1/2" WOODBINDER HSS 304 SS W/ WASHER
awaomadda
QOA.
19R&779
L^q4C �t a�. �. 1jF�PdP
!!•: a .ups 'A
trtr)tl)t)a�}
June 18,2 015
32" OVERALL PANEL WIDTH
Tv
1-3/4" UNDERLAP
/-\ M T7`\
OVERLAP SIDE
Shatod At�IL
C.OA
28" COVERAGE WIDTH #20M
PermaTile
,;MANUFACCQ45E, F99MA3R,ALUMII+uk
Profile
Mott n e u►°i°
�� �....., 0 .,
•'..Vo
ho.44923
-p: STATE OF ; ,C
TC0Rto tn :
DESCRIPTION: PERMATILE PANEL PROFILE
STYLE: PERMATILE .030 ALUMINUM PANEL
FILE: PTPANELPROFILE-01
NOTE: ALWAYS INSTALL PANELS FROM RIGHT
TO LEFT (Looking up at ridge from eave)
U.j
IFREE RIB
FASTENERS 2-1/2" #9 304 STAINLESS
HEX HEAD SELF -DRILLING WITH
ALUMINUM PEPMATILE f EPDM WASHER
PANEL
UNDERIAP SIDE
VIEW
A
PPNElaFa1G ADDEO�
OVERLAP SIDE
SIDE
SIDE
Note: Above is the general screw pattern for Permatile.
For HVHZ zones or wind speed restricted areas, please
see the Permatile Load Table Over Plywood testing
paper for proper fastening in your area.
I.---i
Module/Tlle
Spacing
RIGHT SIDE OF PANE_ LOOKING
FROM FASCIA END (SEE VIEW Al
State at Fit
C.OA
� 9SgTr1
cE
No.4
923
STATE
OF •� a
Aj
DESCRIPTION: PERMATILE SCREW FASTENING DETAIL
STYLE: STANDARD PERMATILE PANEL
FILE: SCREWPATTERN-01
F7
2 E12017C ?
us
norloa owwitg a.we vnunn
EMS Nome Log In User Registratlonv ! HMToplm I Submit Surcharge Stats & Facts Publiodcm FBC Staff I BCIS Site Map '� Links ;~ Seartli
x '}�
Y- Product Approval
bY- USER: Public User
a
Fmtluct Aooroval Menu > PmtluR or Aoollotion Search > Aool'otlon LISP > Application DetaB
FL #
RL5259-1125
Application Type
Revision
Code Version
2014
Application Status
Approved
Comments
Archived
Product Manufacturer POLYGLASS USA
Address/Phone/Email. 150 Lyon Drive
Fernley, NV 89408
(570) 384-1230 Ext 242
jakins@polyglass.com
Authorized Signature James Akins
jakins@polyglass.com
Technical Representative Steve Wadding
Address/Phone/Email 150 Lyon Drive
Fernley, NV 98408
(602) 363-7139
stevew@polyglass.com
THESE PLA;idS AND ALL PROPOSED IINORK
ARE SUBJECT TO ANY CORRECT IONS
'REQUIRED BY FIELD INSPECTORS THA71
MAY BE NECESSARY IN ORDER TO
COMPLY WiT I ALL XIFIMABLE CODES.
Quality Assurance Representative James Akins
Address/Phone/Email 555 Oakridge Road
Humboldt Industrial Pkwy
Hazleton, PA 18201
(800) 894-4563
jakins@polyglass.com
SCANNED
BY
St. Lucie County
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Ucensed
Florida Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed
Robert Nieminen
the Evaluation Report
Florida Ocense
PE-59166
Quality Assurance Entity
UL LLC
Quality Assurance Contract Expiration Date
04/24/2018
Validated By
John W. Knezevich, PE
v. Validation Checklist - Hardcopy Received
Certificate of Independence
FI 5259 R25 COI 2016 01 COI Nieminen ndf
Referenced Standard and Year (of Standard)
Standard
Year
ASTM D1970
2009
ASTM D226
2006
ASTM D6164
2005
ASTM D6222
2008
ASTM G154
2006
ASTM G155
2005
https9Avww.floridabuilding.org/pr/pr app dtl.aspx7param=wGEVXOwtDgvbSgAaZp3Crk2vS°/a2feg01ipmOTAu7g3GAlUPJLg638cVw%3d°had 1/2
208=17
Florida Building Code Online
FM 4474
2004
FRSA/lRI April 2012
2012
TAS 103
1995
UL 1897
2004
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 10/17/2016
Date Validated 10/18/2016
Date Pending FBC Approval 10/19/2016
Date Approved 12/15/2016
Summary of Products
FL#
Model, Number or ame
Description
5259.1
Polyglass Roof
Roofing underlayments
Underiayments
Limits of Use
Installation Instructions
Approved for use in HVH2: No
FL5259 R25 II 2016 30 FINAL ER POLYGLASS UNDERLAYMENTS FL5259-
2R 5.odf
Approved for use outside HVH2: Yes
Impact Resistant: N/A
Verified By: Robert Nieminen PE-59166
Design Pressure: +N/A/-622.5
Created by Independent Third Party: Yes
Other. 1.) The design pressure In this
Evaluation Reports
application relates to one particular
FLS259 R25 AE 2016 10 FINAL ER POLYGLASS UNDERLAYMENTS ELS259-
R25.odf
underlayment system (over concrete deck) for
use under foam -on the systems (where the
Created by Independent Third Party: Yes
underlayment forms part of the load -path).
Refer to ER Section 5.6.4 for other systems,
other deck types and associated maximum
design pressures. 2.) Refer to ER Section 5 for
other limits of use.
Back nest
Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 85U-487-1824
The State of Florida Is an AA/EE0 employer. copyright 20D7-2013 State of Fladda.:: Pdvacv Statement :: Accesslbliity Statement :: Refund Statement
Under Florida law, email addresses ere public remrtls. If you do not want your e-mail address released in response to a publio-records request, do not send electronic
mall to this amity. Instead, contact the office by phone or by hadltioned mall. If you have any questions, please wrrtact 850.487.1395. *Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 201Z Hansom licensed under Chapter 455, F.S. must provide the Department with an email address if they have
one. The malls provided may be used for offidal communication with the licensee. However email addresses are public record. If you do not wish to supply a
personal address, please provide the Department with an email address which can be made available to the public To determine If you are a Ileertes under chapter
455, F.S., please dick here .
Product Approval Acrapts:
°c=
-a A
sccuriLs•r,u;iiite,
htlpsJ/www.floridabuildirlg.orglprlpr_app dtlaspx7param=wGEVXOwIDgvbSgAazp3Crk2vS%a2feg01ipmOTAu7g3GAlUPJLg63BCVw%3d%3d 2PL
r..._ ,
TRINITY' ERD
EVALUATION REPORT
EXTERIOR RESEARCH & DESIGN, I.I.C.
Certificate of Authorization #9503
353 CHRISTIAN STREET, UNIT#13
OXFORD, CT 06478
PHONE: (203) 262-9245
FAX: (203) 262-9243
• Polyglass USA, Inc. Evaluation Report P12060.02.09-R21
.150 Lyon Drive FL5259-R25
Fernley, NV 98408 Date of Issuance: 02/24/2009
Revision 21:10/17/2026
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E.
for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products
described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code sections noted
herein.
DESCRIPTION: Polyglass Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the'Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes orthe
referenced Quality Assurance documentation changes. Trinity) ERD requires a complete review of this Evaluation Report
relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinitylERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 13.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCAANE1983
The facsimile seal appearing was authorized by Robert Nieminen,
P.E. on 10/17/2016. This does not serve as an electronically
signed document. Signed, sealed hardcopies have been
transmitted to the Product Approval Administrator and to the
named dient
CERTIFICATION OF INDEPENDENCE:
1. Trinity]ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity] ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have norwill acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
S. This is a building code evaluation. Neither Trinity) ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
TRINITY, ERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: Roof Underlayments, as produced by Poiyglass USA, Inc., have demonstrated compliance with the
following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is
subject to the Installation Requirements and Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section
Property
Standard
Year
1504.3.1
Wind Uplift
FM 4474
2004
1504.3.1
Wind Uplift
UL 1897
20D4
1504.6
Accelerated Weathering
ASTM G154
2006
1504.6
Accelerated Weathering
ASTM G155
2005
1507.2.3, 1507.3.3,1507.5.3, 1507.7.3,
Physical Properties
ASTM D226
2006
1507.8.3, 1S07.9.3
1507.2.4, 1507.2.9.2, 1507.5.3, 1507.7.3
Physical Properties
ASTM D1970
2009
1507.11.2
Physical Properties
ASTM D6164
2005
1507.11.2
Physical Properties
ASTM D6222
2008
1507.3.3
Installation Practice
FRSA/TRI April 2012
2012
1523.6,5.2.1
Physical Properties
TAS 103
1995
3. REFERENCES:
90211
Examination
Reference
Date
FM Approvals (TST 1867)
Wind Uplift
3004091
O1/12/2000
PRI (TST 5878)
Physical Properties
PRI01111
04/08/2002
PRI (TST 5878)
Physical Properties
PUSA-005-02-01
01/31/2002
PRI (TST 5878)
Physical Properties
PUSA-013-02-01
12/23/2002
PRI (TST5878)
Physical Properties
PUSA-013-02-02
12/23/2002
PRI (TST 5878)
Physical Properties
PUSA-013-02-03
12/23/2002
PRI (TSTS878)
Physical Properties
PUSA-018-02-01.
07/14/2003
PRI (TST 5878)
Physical Properties
PUSA-028-02-01
07/13/2005
PRI (TST 5878)
Physical Properties
PUSA-033-02-01
01/12/2006
PRI (TST 5878)
Physical Properties
PUSA-035-02-01
09/29/2006
PRI (TST 5878)
Physical Properties
PUSA-055-02-02
12/10/2007
PRI (TST 5878)
Physical Properties
PUSA-061-02-02
01/28/2008
PRI (TST 5878)
Physical Properties
PUSA-076-02-01
02/22/2008
PRI (TST 5878)
Physical Properties
PUSA-083-02-01
04/14/2008
PRI (TST 5878)
Physical Properties
PUSA-088-02-01
07/29/2009
MTI (TST 2508)
Physical Properties
JX20H7A
04/O1/2008
MTI (TST 2508)
Physical Properties
RX14E8A
01/29/2009
ERD (TST 6049)
Physical Properties
11752.09.99.1
02/08/2000
ERD (TST 6049)
Wind Uplift
11757.08.01-1
O9/13/2001
ERD (TST 6049)
Wind Uplift
11776.06.02
01/16/2003
ERD (TST 6049)
Physical Properties
02200.07.03
07/14/2003
ERD (TST 6049)
Wind Uplift
P3740.01.07
O1/04/2007
ERD (TST 6049)
Physical Properties
P5110.04.07-1
04/11/2007
ERD (TST 6049)
Wind Uplift
P9260.03.08
03/21/2008
ERD (TST 6049)
Physical Properties
P13450.08.09
08/13/2009
ERD (TST 6049)
Wind Uplift
P30540.11.09-R3
11/30/2009
ERD (TST 6049)
Physical Properties
P11030.11.09-1
11/30/2009
ERD (TST 6049)
Wind Uplift
P31030.11.09-2
11/30/2009
ERD (TST 6049)
Physical Properties
P11030.11.09-3
11/30/2009
ERD (TST 6049)
Physical Properties
P33360.06.10
06/25/2010
Exterior Research and Design, I.I.C.
Certificate of Authorization N9503
FBC NON-HVHZ EVALUATION
Evaluation Report P32060.02.09-R21
FL5259-R25
Revision 21: 10/17/2016
Page 2 of 13
TRINITY l! ERD
90ifty
Examination
Reference
Date
ERD (TST 6049)
Physical Properties
P33370.03.11
03/02/2011
ERD (TST 6049)
Physical Properties
P33370.04.11
04/26/2011
ERD (TST 6049)
Physical Properties
P37300.10.11
10/19/2011
ERD (TST 6049)
Physical Properties
P40390.08.12-1
08/06/2012
ERD (TST 6049)
Physical Properties
P40390.08.12-2
09/07/2012
ERD (TST 6049)
Physical Properties
C41420.09.12-3
09/11/2012
ERD (TST 6049)
Wind Uplift
P39680.03.13
03/04/2013
ERD (TST 6049)
Physical Properties
P45370.04.13
04/26/2013
ERD (TST 6049)
Wind Uplift
P1738.02.07-R2
04/29/2013
ERD (TST 6049)
Wind Uplift
11757.04.01-1-R1
04/30/2013
ERD (TST 6049)
Wind Uplift
P41630.08.13
08/06/2013
ERD (TST 6049)
Wind Uplift
P11751.05.03-Ri
11/26/2013
ERD (TST 6049)
Wind Uplift
P11781.11.03-Ri
11/26/2013
ERD (TST 6049)
Physical Properties
P45270.05.14
05/12/2014
ERD (TST 6049)
Physical Properties
6020.07.14-1
09/08/2014
ERD (TST 6049)
Physical Properties
6020.09.14-2
09/08/2014
ERD (TST 6049)
Physical Properties
6020,09.14-3
09/08/2014
ERD (TST 6049)
Physical Properties
6020.09.14-4
09/08/2014
ERD (TST 6049)
Physical Properties
6020.09.14-5
09/08/2014
ERD (TST 6049)
Physical Properties
6020.09.14-6
09/08/2014
ERD (TST 6049)
Physical Properties
P46520.10.14
10/03/2014
ERD (TST 6049)
Physical Properties
P44360.10.14
10/07/2014
ERD (TST 6049)
Physical Properties
P43290.10.14
10/17/2014
ERD (TST 6049)
Physical Properties
PLYG-SC7550.03.15
03/24/2015
ERD (TST 6049)
Physical Properties
P40390.04.15
04/03/2015
ERD (TST 6049)
Physical Properties
PLYG-SC8080.05.15-1
05/20/2015
ERD (TST 6049)
Wind Uplift
PLYG-SC8905.05.16-1
05/17/2016
ERD (TST 6649)
Physical Properties
PLYG-SC8080.07.16
07/16/2016
ERD (TST 6049)
Wind Uplift
PLYG-SC12025.30.16
10/12/2016
ICC-ES (EVL 2396)
IBC Compliance
ESR-1697
11/01/2014
Miami -Dade (CER 1592)
HVHZ Compliance
NOA 14-0717.09
01/22/2015
Polyglass USA
Manufacturing Affidavit
Products Current
02/18/2009
Polyglass USA
P/LAffidavit
Mule -Hide Crass Ltg
03/01/2008
Polyglass USA
Materials Affidavit
Polystick SA Compound
08/18/2011
UL, L-C. (QUA9625)
quality Control
Service Confirmation
Exp. 04/24/2018
4. PRODUCT DEScRIPTION:
4.1 Mechanically Fastened Underlayments:
4.1.1 Elastobase is a fiberglass reinforced, SBS modified bitumen base sheet.
4.1.2 Elastobase P is a polyester -reinforced, SBS modified bitumen base sheet.
4.1.3 Polyglass G2 Base is a fiberglass -reinforced, asphaltic base sheet.
4.1.4 Polyglass APP Base is a fiberglass -reinforced, APP modified bitumen base sheet.
4.2 Self-AdheringUnderlayments:
4.2.1 Polystick MTS is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, surfaced
with polyolefinic film surface; meets ASTM D1970 and TAS 103.
4.2.2 Polystick MTS PLUS is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced
surfaced with poly -film surface; meets TAS 103.
4.2.3 Polystick IR-Xe is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with an
aggregate surface; meets ASTM D3970.
Exterior Research and Design, U.C. Evaluation Report P12060.02.09-R21
Certifimte of Authorization H9503 FBC NON-HVHZ EVALUATION FL5259-R25
Revision 21: 10/17/2016
Page 3 of 13
a
TRINITY! ERD
4.2.4 Polystick TU Plus is a nominal 0-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with a
of esterfabric surfac ets ASTM D1970 and TAS 103.
4.2.5 Polystick TU P is a nominal 130-mil thick rubberized asphalt waterproofing membrane, glass-fiber/polyester
reinforced, with a granular surface; meets ASTM D1970 and TAS 103.
4.2.6 Polystick TU Max is a nominal 60-mil thick rubberized asphalt waterproofing membrane with a 190 g/m2 polyester
fabric surface; meets ASTM D1970 and TAS 103.
4.2.7 Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR) are polyester
reinforced, APP modified bitumen cap sheets; meet ASTM D6222.
4.2.8 Polystick Dual Pro" is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass
reinforced, with a polyester fabric surface; meets ASTM D1970.
4.2.9 Polystick Tile Prom is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass
reinforced, with a polyester fabric surface; meets ASTM D1970 and TAS 103.
4.2.10 Polystick MU-X is a nominal 54-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass
reinforced, with a polypropylene film surface; meets AC188 and physical requirements of ASTM D3970.
4.3 Mechanically Fastened and/or Bonded Underlayments:
4.3.1 Elastoflex SIG and Elastoflex S6 G FR are polyester reinforced, SBS modified bitumen cap sheets; meet ASTM D6164.
4.3.2 Polyflex G and Polyflex G FR are polyester reinforced, APP modified bitumen cap sheets; meet ASTM D6222.
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity ERD nor Robert Nieminen, P.E. are, in any way, the Designer of
Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire
ratings of this product.
5.4 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for
approval based on this evaluation combined with supporting data for the prepared roof covering.
5.5 Allowable Roof Covers:
TABiis 1: RooF CoyErtOPnoes �.r - ` -
,� y
Underlayment
Asphalt Shingles
Nail -On Tile
Foam -On Tile
Metal
wood Shakes&
Slate
shingles
Yes
Yes
Elastobase -
Yes
(base sheet 2�ly
(base sheet in 2-ply
Yes
Yes
Yes
system)
system)
Yes
Yes
ElastobaseP
Yes
)basesheetin2-ply
(base sheet in 2-pry
Yes
Yes
Yes
system)
system)
Yes
Yes
Polyglass G2 Base
No
(base sheet In 2-ply
(base sheet N 2-pry
No
No
No
system)
system)
Yes
Yes
Polyglass APP Base
No
(base sheet In 2-ply
(base sheet in 2-ply
No
No
No
system)
system)
Polystick MrS
Yes
Yes
No
Yes
Yes
Yes
Polystick Mrs PLUS
Yes
Yes
No
Yes
Yes
Yes
Polystick lR-Xe
Yes
No _
_No
No
Yes
Yes
Polystick TUP
Yes
Yes
Yes
No
Yes
Yes
See S.S.1
Polystick TU Plus
Yes
Yes
Yes
Yes
Yes
Yes
See S.5.1
Exteno�'LC.
Certificate of Authorization #9503
FBC NON-HVHZ EVALUATION
Evaluation Report P12060.02.09-R21
FL5259-R25
Revision 21: 10/17/2016
Page 4 of 13
J
TRINITY ' ERD
... _,..•..'. ," - - ,+.: :`. _ ", :.TABLE1: RoDFCovER6PT10N5=-.: .',.. �... ..
Underlayment
Asphalt Shingles
Nail -On Tile
Foam -On Tile
Metal
wood Shakes&
Slate
Shingles
Polys[ick TO Max
No
Yes
Yes
Yes
No
No
See 5.5.1
Polystick Dual Pro
Yes
Yes
No
Yes
Yes
Yes
Polystick Tile Pro
Yes
Yes
Yes
Yes
Yes
Yes
See 5.S.1
Polystick MU-X
Yes
No
No
Yes
Yes
Yes
Elastoflex S6G
Yes
Yes
Yes
No
Yes
Yes
See 5.5.1
Elastoflex S6 G FR
Yes
Yes
No
No
Yes
Yes
Polyflex G
Yes
Yes
Yes
No
Yes
Yes
See 5.5.1
Polyflex G FR
Yes
Yes
No
No
Yes
Yes
Polynex SAP or SAP FR
Yes
Yes
Yes
No
Yes
Yes
See 55.1
Mule -Hide SA-APP Cap Sheet
Yes
or SA-APP Cap Sheet (FR)
Yes
Yes
See 5.5.1
No
Yes
Yes
5.5.1 "Foam -On Tile" is limited to use of the following Approved tile adhesives unless tensile adhesion / long term aging
data from an accredited testing laboratory is provided.
✓ 3MTM 2-Component Roof Tile Adhesive AH-160 (FL6332): Polystick TU P, Polystick TU Plus, Polystick TU Max,
Elastoflex S6 G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR, Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP
Cap Sheet (FR) or Tile Pro.
✓ 3M" Foam Roof 'rile Adhesive RTA-1 (FL6276): Polystick TU P, Polystick TU Plus, Polystick TU Max, Elastoflex S6
G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR, Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR)
or Tile Pro
✓ Convenience Products' Touch 'n Seal Storm Bond Roof,Tile Adhesive (FL34506): Polystick TU Plus, Polystick TU
Max.
✓ Dow TileBond (FL717):* Polystick TU P, Polystick TU Plus, Polyflex SAP or Tile Pro.
✓ Polyglass PolyLok Roof Tile Adhesive (FL37855): Polystick TU Plus or Polystick TU Max.
5.6 Allowable Substrates:
5.6.1 Direct -Bond to Deck:
Polystick (all variations), Dual Pro, Tile Pro, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet
(FR) self -adhered to:
➢ New untreated plywood; ASTM D41 primed new untreated plywood; Existing plywood; ASTM D41 primed existing
plywood; New or existing, unprimed OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed
Southern Yellow Pine; ASTM D41 primed structural concrete; Huber Engineered Woods "ZIP System" Panels
(designed and installed to meet wind loads for project).
Note: Polyglass does not require priming of new or existing plywood or 05B sheathing. New or existing plywood or
OSB sheathing should be cleaned of all dirt and debris prior to application of Polystick membranes.
Elastoflex S6 G or S6 G FR in hot asphalt to:
➢ ASTM D41 primed structural concrete.
Polyflex G or G FR torch -applied to:
➢ ASTM D41 primed structural concrete.
Exterior Research and Design, U.C.
Certificate of Authorizotion #9503
FBC NON-HVHZ EVALUATION
Evaluation Report P12060.02.09-R21
F15259-R25
Revision 21: 10/17/2016
Page 5 of 13
l--Ji
TRINITY ERD
5.6.2 Bond -to -Insulation:
Polystick (all variations), Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered
to:
➢ ASTM C1289, Type II, Class 1 polyisocyanurate or Type V polyisocyanurate-composite insulation; Dens Deck
DuraGuard; Dens Deck Prime; or SECUROCK Gypsum -Fiber Roof Board.
Elastoflex S6 G or S6 G FR in hot asphalt to:
➢ Dens Deck Prime orSECUROCK Gypsum -Fiber Roof Board.
Polyflex G or G FR torch -applied to:
➢ ASTM D41 primed structural concrete; Dens Deck Prime or SECUROCK Gypsum -Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum
requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam -on tile
systems, insulation attachment shall be designed by a qualified design professional and installed based on testing of
the insulation/underlayment system in accordance with FBC Section 1504.3.1.
5.6.3 Bond to Mechanically Attached Base Laver:
Polystick (all variations), Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Dual Pro or
Tile Pro self -adhered to:
> ASTM 0226, Type I or 11 felt; Elastobase; Elastobase P or Mule -Hide Nail Base.
Elastoflex S6 G or S6 G FR in hot asphalt to:
> ASTM D226, Type I or II felt; Elastobase; Elastobase P, Mule -Hide Nail Base or Polyglass G2 Base.
Polyflex G or G FR torch -applied to:
D Elastobase; Elastobase P, Mule -Hide Nail Base, Polyglass G2 Base or Polyglass APP Base.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum
codified requirements. For installations under foam -on tile systems, base layer shall be attached per minimum
requirements of FRSA/TRI April 2012 (04-12), Appendix A, Table 1, or as listed in Section 5.6.4 herein, or as tested in
accordance with FBC Section 1504.3.1.
5.6.4 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12) does not
address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where the underlayment
forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not
addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on tile applications. Maximum Design Pressure is the
result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure
divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-
12), Appendix A, Table 1A or FBC 1609 for determination of design wind loads.
5.6.4.1 Maximum Design Pressure=-90 usf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: None
Base Ply: (Optional) Polystick MTS PLUS, self -adhered
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
5.6.4.2 Maximum Design Pressure=-97.5 osf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Base Ply: (Optional) Polystick MTS PLUS, self -adhered
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x
1'/." ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c.
Exterior Research and Design, I.I.C.
Certificate o/Authorization #9503
FBC NON-HVHZ EVALUATION
Evaluation Report P12060.02.09-R21
FL5259-R25
Revision 21: 10/17/2016
Page 6 of 13
{ l ` / TR" 1N1TY { ERD
5.6.4.3 Maximum Design Pressure = -105 osf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: WB-3000
Base Ply: (Optional) Polystick MTS PLUS, self -adhered
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x
IY." ring shank nails through 32 ga., 1-5/9" diameter tin caps spaced 12-inch o.c.
5.6.4.4 Maximum Design Pressure =-135 osf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: (Optional) PG100 or ASTM D41
Joints: Min. 4-inch wide strips of Elastoflez SA-V over all plywood joints.
Base Ply: (Optional) Polystick MTS PLUS, self -adhered
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
5.6.4.5 Maximum Design Pressure =-315 osf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Base Ply: (Optional) Polystick MTS PLUS, self -adhered
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Tile Pro, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap
Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
5.6.4.6 Maximum Design Pressure = -622.5 nsf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Underlayment: Elastoflez S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
5.6.4.7 Maximum Design Pressure = -30.0 osf':
Deck: Min. 15/32-inch OSB to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga. x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing; 6-inch o.c. at the 3-Inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS PLUS, self -adhered
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
5.6.4.8 Maximum Design Pressure=-37.5 osf•:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga. x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS PLUS, self -adhered
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
5.6.4.9 Maximum Design Pressure=-37.5 osf':
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: One (1) or two (2) layers ASTM D226, Type II felt
Fasteners: 11 ga. x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c. at the 3-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt.
Exterior Research and Design, I.I.C.
Certificate of Authorization R9503
FBC NON-HVHZ EVALUATION
Evaluation Report P12060.02.09-R21
FL5259-RZS
Revision 21: 10/17/2016
Page 7 of 13
r
• � TRiNIIY I ERD
5.6.4.10 Maximum Design Pressure =45 osf•
Deck:
Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet:
One (1) layer ASTM D226, Type II felt
Fasteners:
11 ga. x 1.25-inch x 3/8-Inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing:
4-inch o.c. at the 2-inch wide side laps and 4-inch o.c. at two (2) equally spaced staggered center rows.
Base Ply:
(Optional; for use with self -adhering underlayment only) Polystick MTS PLUS, self -adhered
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered or Elastoflex 56 G, applied in full mopping of hot asphalt
5.6.4.11 Maximum Design Pressure =-45 osf•:
Deck:
Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet:
Two (2) layers ASfM D226, Type II felt
Fasteners:
11 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing:
9-inch o.c. at the 2-inch wide side laps and 9-inch o.c. at two (2) equally spaced staggered center rows.
Base Ply:
(Optional; for use with self -adhering undedayment only) Polystick MTS PLUS, self -adhered
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered or Elastoflex S6 G, applied in full mopping of hot asphalt
5.6.4.12 Maximum Design Pressure =-45 osf:
Deck:
Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet:
Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners:
Simplex MAXX Cap Fasteners
Spacing:
9-inch o.c. at the 2-inch wide side laps and 18-inch o.c, at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hat asphalt or Polyflex G, torch -applied.
5.6.4.13 Maximum Design Pressure=-52.5 osf:
Deck:
Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet:
Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners:
Simplex MAXX Cap Fasteners
Spacing:
9-inch o.c. at the 2-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex 56 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
5.6.4.14 Maximum Design Pressure =-52.5 osf•.
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: Simplex Original Cap Nails
Spacing: 6-inch o.c. at the 3-inch wide side laps and 5-inch o.c. at four (4) equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS PLUS, self -adhered
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
5.6.4.15 Maximum Design Pressure =-52.5 osf:
Deck:
Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet:
Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners:
Simplex Original Cap Nails
Spacing:
6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied In full mopping of hot asphalt or Polyflex G, torch -applied.
5.6.4.16 Maximum Design Pressure =-60osf:
Deck:
Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet:
Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners:
11 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing:
8-inch o.c. at the flinch wide side laps and 8-Inch o.c, at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
Exterior Research and Design, U.C.
Certificate of Authorization N9503
FBC NON-HVHZ EVALUATION
Evaluation Report 1312060.02.09-1121
FL5259-RZS
Revision 21: 10/17/2016
Page 8 of 13
TRINITY tERD
5.6.4.17 Maximum Design Pressure =-60 osf:
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: OMG #12 Standard Roofgrip with OMG Fiat Bottom Metal Plates
Spacing: 12-inch o.c. at the 4-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
5.6.4.18 Maximum Design Pressure=-67.5 osf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass APP Base (requires use of torch -applied underlayment)
Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 8-inch o.c. at the 4-inch wide side laps and 8-inch o.c, at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -applied.
5.6.4.19 Maximum Design Pressure =-75
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass APP Base (requires use of torch -applied underlayment)
Fasteners: Dekfast #14 with Dekfast Hex plates, OMG #14 HD with OMG 3" Galvalume Steel Plates, OMG Roofgrip #14 with
OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap
Fasteners
Spacing: 10-inch o.c. at the 4-inch wide side laps and 10-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polynex G, torch -applied.
5.6.4.20 Maximum Design Pressure=-9O osf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c. at the 2-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
5.6.4.21 Maximum Design Pressure =-90osf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3" Round Metal Plates or OMG Flat Bottom Metal
Plates
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
5.6.4.22 Maximum Design Pressure = -90 osf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface)
Fasteners: Trufast #12 DP or Trufast #14 HD with Trufast 3" Metal Insulation Plates
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt
5.6.4.29 Maximum Design Pressure = -90 osf
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass APP Base (requires use of torch -applied underloyment)
Fasteners: Dekfast #14 with Dekfast Hex plates, OMG #14 HD with OMG 3" Galvalume Steel Plates, OMG Roofgrip #14 with
OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap
Fasteners
Spacing: 9-inch o.c. at the 4-inch wide side laps and 97inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -applied.
Exterior Research and Design, I.I.C. Evaluation Report P12060.02.09-R21
Certificate of Authorization #9503 FBC NON-HVHZ EVALUATION FL5259-R25
Revision 21: 10/17/2016
Page 9 of 13
'd TRINITY' ERD
5.6.4.24 Maximum Design Pressure =-97.5 psf:
Deck:
Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet:
Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners:
it ga. x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing:
4-inch o.c. at the 4-inch wide side laps and 4-inch o.c. at four (4) equally spaced staggered center rows.
Base Ply:
(Optional) Polystick MTS PLUS, self -adhered
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered. -
5.6.4.25 Maximum Desien Pressure =-105 psf:
Deck:
Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet:
Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners:
Simplex MAXX Cap Fasteners
Spacing:
6-inch o.c. at the 2-inch wide side laps and 6-inch o.c. at three (3) equally spaced, staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
5.6.4.26 Maximum Design Pressure=-112.5 psf:
Deck:
Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet:
Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners:
11 ga. x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing:
6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Primer:
PG100 or ASTM D41 primer at all tin -caps
Base Ply:
Polystick MTS PLUS, self -adhered
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
5.6.4.27 Maximum Design Pressure = -120 psf:
Deck:
Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet:
Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners:
OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3" Round Metal Plates or OMG Flat Bottom Metal
Plates
Spacing:
6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at five (5) equally spaced staggered center rows.
Underlayment: Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
5.6.4.28 Maximum Design Pressure = -220 psf:
Deck:
_
Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet:
Elastobase (sanded top surface)
Fasteners:
Trufast #12 DP or Trufast #14 HD with Trufast 3" Metal Insulation Plates
Spacing:
6-inch o.c. at the 4-inch wide side laps and 6-inch o.c, at five (5) equally spaced staggered center rows.
Underlayment: Elastoflex 56 G, applied in full mopping of hot asphalt.
5.6.4.29 All other direct -deck, adhered Polyglass underlayment systems beneath foam -on tile systems carry a Maximum
Design Pressure of -45 psf.
5.6.4.30 For mechanitally_attached base sheet, the maximum design pressure for the selected assembly shall meet or exceed
the Zone 1 design pressure determined in accordance with FRSA/TRI April 2012 (04-12), Appendix A, Table 3A or FBC
1609. Zones 2 and 3 shall employ an attachment density designed by a.qualified design professional to resist the
elevated pressure criteria. Commonly used methods are RAS 117, FM LPDS 1-29 and AN51/SPRI WD1. Assemblies
marked with an asterisk' carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29
(January 2016) for Zone 2/3 enhancements.
5.7 Exposure Limitations:
Elastobase, Elastobase P, Polyglass G2 Base or Polyglass APP Base shall not be left exposed for longer than 30-days
after installation,
Polystick IR-Xe or Polystick MU-X shall not be left exposed for longer than 90-days after installation.
Polystick MTS, MTS PLUS, TU P, TU Plus, TU Max, Dual Pro or Tile Pro shall not be left exposed for longer than 180-
days after installation.
Exterior Research and Design, LLC.
Certificate of Authorization #9503
FBC NON-HVHZ EVALUATION
Evaluation Report P12060.02.09-R21
FL5259-R25
Revision 21: 10/17/2016
Page 10 of 13
1
,:- I�RII�IIlY
ERD
.,
Polyflex SAP or SAP FR, or Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) does not have an exposure
limitation, unless the prepared roof covering is to be adhesive -set tile, in which case the maximum exposure is 30
days.
Elastoflex S6 G or S6 G FR or Polyflex G or G FR does not have an exposure limitation, unless the prepared roof
covering is to be adhesive -set tile (Elastoflex S6 G or Polyflex G only), in which case the maximum exposure is 180
days.
INSTALLATION:
6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation requirements
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris prior to application, and prime the substrate (if applicable).
6.3 Elastobase. Elastobase P or Mule -Hide Nail Base:
6.3.1 Shall be installed in compliance with the codified requirements for ASTM D226, Type II underlayment in FBC Sections
1507 for the type of prepared roof covering to be installed.
6.3.2 Non -Tile Applications:
Reference is made to the current edition of the NRCA Steep -slope Roofing Manual and ARMA recommendations for
installing shingle underlayments and flashings
Elastobase, Elastobase P or Mule -Hide Nail Base may be covered with a layer of Polystick, Polyflex SAP or SAP FR,
Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), Dual Pro or Tile Pro, self -adhered, Elastoflex S6 G or S6 G FR in
hot asphalt or Polyflex G or G FR, torch applied.
6.3.3 Tile Applications: -
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted
above as a guideline.
6.4
6.4.1
6.4.2
Polystick MTS, MTS PLUS, IR-Xe, TU P. TU Plus, TU Max, Dual Pro, rile Pro or MU-X or Polyflex SAP, Polyflex SAP FIR
Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Can Sheet (FRI:
Shall be installed in compliance with the codified requirements for ASTM D3970 underlayment in FBC Sections 1507
for the type of prepared roof covering to be installed.
Direct -to -Deck with Mechanically Fastened Roof Covers:
All self -adhering materials, with the exception of Polystick TU Plus, Polyflex SAP or SAP FR and Mule -Hide SA-APP Cap
Sheet or SA-APP Cap Sheet (FR) should be back -nailed in selvage edge seam in accordance with Polyglass / Mule -Hide
Back Nailing Guide. Nails shall be corrosion resistant, 11 gauge ring -shank type with a minimum 1-inch diameter
metal disk or Simplex -type metal cap nail, at a minimum rate of 12" o.c. Polystick TU Plus should be back -nailed using
the above noted fasteners and spacing, in area marked "nail area, area Para clavar" on the face of membrane. The
head lap membrane is to cover the area being back -nailed
All seal -lap seams (selvage laps) must -
firmly rolled with a -minimum 28 lb. hand
roller to ensure full contact and adhesion.
For Dual Pro and Tile Pro, align the edge of
the top sheet to the end of the glue pattern
(the sheet will overlap the fabric).
Exterior Research and Design, U.C.
Certificate of Authorization #9503
View of Ovelap Seam of Dual Pro and Tile Pro
FBC NON-HVHZ EVALUATION
Evaluation Report P32060.02.09-1121
FL5259-R25
Revision 21:10/17/2016
Page 11 of 13
r }
TPJNIlY ERD
All over -fabric and over -granule end -laps shall have a 6-inch wide, uniform layer of Polyplus 50 Premium Modified
Wet/Dry Cement or Polyglass PG500 Modified Cement applied in between the application of the lap.
Polystick TU Plus, Dual Pro and Tile Pro may not be used in any exposed application such as crickets, exposed valleys,
or exposed roof to wall details
Repair of Polystick membranes is to be accomplished by applying Polyplus 50 Premium Modified Wet/Dry Cement or
Polyglass PG500 Modified Cement to the area in need of repair, followed by a minimum 6 x 6 inch patch of the
Polystick material of like kind, set and hand rolled in place over the repair area. Patch laps, if needed, shall be
installed in a water shedding manner.
All Polystick membranes shall be installed to ensure full contact with approved substrates. Polyglass requires a
minimum of 40-lb weighted -roller or, on steep slopes, use of a stiff broom with approximately 40-lbs of load applied
for the field membrane. Hand rollers are acceptable for rolling of patches, laps (min. 28lb roller) or small areas of the
roof that are not accessible to a large roller or broom.
6.4.3 Tile Applications (not allowed for PalvsticklR-XeorPolystick MU-X):
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted
above as a guideline.
For mechanically fastened tile roofing over 2-ply system, consisting of base sheet and self -adhering top sheet(s), base
sheet fastening shall be not less than FRSA/TRI April 2012 (04-12), Table 1.
For adhesive -set tile applications, refer to Section 5.6.4 herein.
For nail -on tile systems over Polystick MTS, battens are required for loading / staging of the tile.
For nail -on tile systems over Polystick MTS PLUS:
D Battens are required for loading/staging of lugged tile regardless of slope.
D Battens are required for loading/staging of flat tile at slopes in excess of 5:12.
6.4.4 Two (2) Ply Underlavment Systems:
Polystick MTS or MTS PLUS followed by Polystick MTS, MTS PLUS, TU P, TU Plus, TU Max, rile Pro, MU-X or Polyflex
SAP is allowable for use under mechanically attached prepared roof systems. Limits of use are those associated with
the top -layer material. This is not a requirement, but is allowable if a 2-ply underlayment system is desired.
Polystick MTS PLUS followed by Polystick TU P, TU Plus, TU Max, Tile Pro or Polyflex SAP is allowable for use under
foam -on tile systems. Limits of use are those associated with the top -layer material. This is not a requirement, but is
allowable if a 2-ply underlayment system is desired.
6_5 Elastoflex S6 G or S6 G FR:
6.5.1 Elastoflex S6 G or S6 G FR shall be installed in compliance with current Polyglass published installation requirements.
For use in tile applications, reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein.
6.5.2 , Elastoflex S6 G or S6 G FR shall be fully asphalt -applied to the substrates noted in Section 5.6. Side laps shall be
minimum 3-inch and end -laps minimum 6-inch wide, off -set minimum 3 feet from course to course. Side and end
laps shall be fully adhered in a complete mopping of hot asphalt with asphalt extending approximately 3/8-inch
beyond the lap edge.
6.6 Polyflex G or G FR:
6.6.1 Polyflex G or G FR shall be installed in compliance with current Polyglass published installation requirements. For use
in tile applications, reference is made FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein.
6.6.2 Polyflex G or G FR shall be fully torch -applied to the substrates noted in Section 5.6. Side laps shall be minimum 3-
inch and end -laps minimum 6-inch wide, off -set minimum 3 feet from course to course. Side and end laps shall be
fully heat -welded and inspected to ensure minimum 3/8-inch flow of modified compound beyond the lap edge.
6_7 , Tile Staging:
6.7.1 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. Refer to
Polyglass published requirements for tile staging.
Exterior Research and Design, I.I.C. Evaluation Report P12060.02.09-1121
Certifkate ofAutharization #9503 FBC NON-HVHZ EVALUATION FL5259-R25
Revision 21: 10/17/2016
Page 12 of 13
-a TRINITY ? ERD
6.7.2 Battens and/or Counter -battens, as required by the tile manufacturer and FRSA/TRI April 2012 (04-12) must be used
on all roof slopes greater than 7:12. Precautions should be taken as needed, such as the use of battens or sail-
boards, to prevent tile sliding and/or damage to the underlayment during the loading process.
6.7.3 For nail -on tile systems over Polystick MTS, battens are required for loading / staging of the tile.
6.7.4 For nail -on tile systems over Polystick MTS PLUS:
➢ Battens are required for loading/staging of lugged tile regardless of slope.
➢ Battens are required for loading/staging of flat tile at slopes in excess of 5:12.
6.7.5 The minimum cure time after installation of self -adhering membranes and before loading of roofing tiles is forty-eight
(48) hours. .
7. BUILDING PERMIT REQUIREMENTS: _
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
S. MANUFACTURING PLANTS:
• Contact the noted QA agency for information on product locations covered for F.A.C. Rule 61G20-3 QA requirements.
9. QUALITY ASSURANCE ENTITY:
UL, LLC—QUA9625; (314) 578-3406; lcchancellor@us.ul.com
- END OF EVALUATION REPORT -
Exterior Research and Design, U.C. Evaluation Report P12060.02.09-R21
Certificate of Authorization#9503 - FBC NON-HVHZ EVALUATION FL5259-R25
Revision 21: 10/17/2016
Page 13 of 13