Loading...
HomeMy WebLinkAboutELECTRICAL PROPOSALSCANNED BY Electrical Proposal I LEE u tii ,f St. Lucie County - -. .,,.,...�.. 7/27/2017 OWNER INFORMATION Name Remodel of Vero Beach Address 3321 Bridge Plaza Dr. City, State ZIP Vero Beach, Fl. 32963 Phone Email Project name Ft. Pierce Condo SCOPE OF WORK CONTRACTOR INFORMATION Company Brandon Blais Electric Address 1056 Old Dixie Hwy. Suite B City, State ZIP Vero Beach, FI. 32960 Phone 772.559.5196 Email BmndonBlaisElec@gmail.com 1. Replace all outlets and switches to Decora • 12. Replace master bath exhaust fan 2. Move washer and dryer outlet' 13. Replace master closet light with round LED light 3. Move kitchen switch to dining room area s 14. Add (1) 4" recess light in guest bathroom 4. Remove phone outlet in kitchenr 15. Add (1) 4" recess light over toilet in guest bath S. Move hall and dining switch by bathroom door • 16. Replace guest bath exhaust fan 6. Remove 6" recess lights in kitchen# 17. Add closet light and switch in guest bedroom 7. Add (2) 4" recess lights in hall • 18. Install (6) dimmers 8. Add (6) 4" recess lights in kitchenr 9. Remove vanity light in master bathroom 10. Add (2) 4" recess lights over master bath sink 11. Add (1) 4" recess light in master bath shower INCLUDED : +• `' 13 Recess can w/trim LED ST WCIEt'A P - 1 15" Round LED Fixture - 2 Bath exhaust fans 20 Receptacles Q 'BLDG. 13 1 Pole Switches O q G j - DA'M• 4 3way switches 6 LED Dimmers t - ELEC: 4 GFloutlets �O OATB: 1 i Stack switch Dryeroutlet O muss DATE - Wire, Boxes and connectors MECH. ,_�. nATC- Vvjz; tie � `,y�' �'° • N Y wrightsofte Project Summary Entire House WEB REPS LLC. Job: Hlblscus By the Sea, 0 &.. Date: August 14, 2017 By: Anthony Avena Plan: Hibiscus By the Sea, 05 1880 82nd !venue Suite It 203. Vero Beach, FL 32966 Phone: S00 810J280 Fax ass 971.2999 Email: a nthony@mbrepshwc.com Vlkb: v .mbrepsxfiWesale.com License:... Project• • For: Dave Rhoades, Rhoades Air&Heat RECE= 6 w EED 8285 104th Court, Vero Beach, FL 32967 Phone: 772 571-5734 AUG 2 9 2017 Email: rhoadesair@gmail.com Notes: Hibiscus By the Sea, # 505 Bid 1, 3870 N A1A, Fort Pierce, FL der rn i 4- nVR. 00) 0 Weather: Vero Beach Muni, FL, US Winter Design Conditions Summer Design Conditions Outside db 43 OF Outside db 91 OF Inside db 70 OF Inside db 75 OF Design TO 27 OF Design TO 16 OF Daily range L Relative humidity 50 % Moisture difference 59 grab Heating Summary Sensible Cooling Equipment Load Sizing Structure 12420 Btuh Structure 14369 Btuh Ducts 2594 Btuh Ducts 3764 Btuh Central vent (21 cfm) 612 Btuh Central vent (21 cfm) 351 Btuh Outside air Outside air Humidification 0 Btuh Blower 1707 Btuh Piping 0 Btuh Equipment load 15625 Btuh Use manufacturer's data y Rate/swing multiplier Equipment load 1.00 20191 Btuh Infiltration sensible Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 6043 Btuh Ducts 942 Btuh Central vent (21 cfm) 831 Btuh Heatingy Coolingg Outside air Area (ft2 1288 1288 Equipment latent load 7817 Btuh Volume �W) 10308 10308 Air changes/hour 0.45 0.23 Equipment Total Load (Sen+Lat) 28007 Btuh Equiv. AVF (cfm) 77 40 Req. total capacity at 0.70 SHR 2.4 ton Heating Equipment Summary Cooling Equipment Summary Make Trane Make Trane Trade Trade Model GSHC0301B Cond GSHC0301B AHRI ref Coil AHRI ref Efficiency 4.24 COP Efficiency 12.89 EER Heating Input 13.6 kW Sensible cooling 20210 Btuh Heating output 46305 Btuh Latent cooling 8661 Btuh Temperature rise 54 OF Total cooling 28871 Btuh Actual air flow 779 cfm Actual air flow 779 cfm Air flow factor 0.052 cfm/Btuh Air flow factor 0.043 cfm/Btuh Static pressure 0.59 in H2O Static pressure 0.59 in H2O Space thermostat Load sensible heat ratio 0.72 Capacity balance point = 0 OF Backup: American Standard 10KW Heat Strip Input = 10 kW, Output = 34121 Btuh, 100 AFUE Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. .-%� 2017-Aug-141 + wright SCft' RlghtSuile® Universal 201717.0.23 RSU00902 Page 1 �y Page 1 AI.tA� ...rend Heat,Hibiscus By The Sea, Bid 1 d SOS.rup Cale = MI8 Fmnt Door faces: S 8x8 98, 6x6 65 cfi 8x8 148 cfm #: Hibiscus By the Sea, # 505 Bid 1, 38... Performed by Anthony Averse for - Dave Rhoades 8285 104th Court Vero Beach, R.32967 Phone: 7725715734 # 505, Bldg 1 WEB REPS LLC. 1880 82ndAvenue Suite # 203 Vero Beach, R-32966 Phone: 800810-3280 Fax 888971-2999 repswholesalenom anthoniy@Nebrepstuac.com Scale: 1 : 78 Page 1 RIMI- ite® Urdvasal 2017 17.0.23 RS000902 2017-Au,F1416'.48-.43 ...sas By The Se, Bld 1 #505.rup 1- wrightsoft• Duct System Summary Entire House WEB REPS LLC. Job: Hibiscus By the Sea, # 5... Date: August 14, 2017 By: Anthony Aversa Plan: Hibiscus By the Sea, # 5 1880 82nd Avenue Suite @ 203, Vem Beach, FL 32988 Phone: 800 810-VM Fax 888 971-2999 Email: anthony@mbrepshvac.com Web: v .vebrepsvlrolesale.com License:... Project • • For: Dave Rhoades, Rhoades Air & Heat 8285 104th Court, Vero Beach, FL 32967 Phone: 772 571-5734 Email: rhoadesair@gmail.com Heating Cooling External static pressure 0.59 in H2O 0.59 in H2O Pressure losses 0.22 in H2O 0.22 in H2O Available static pressure 0.37 in H2O 0.37 in H2O Supply / return available pressure 0.284 / 0.086 in H2O 0.284 / 0.086 in H2O Lowest friction rate 0.140 in/100ft 0.140 in/100ft Actual air flow 779 cfm 779 cfm Total effective length (TEL) 264 it Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Mail Actual Ln (ft) Ftg.Egv Ln (ft) Trunk Bath h 867 45 16 0.163 4.0 Ox0 VIFx 23.8 150.0 st1 Bedroom h 2573 134 70 0.140 6.0 Ox0 VIFx 32.2 170.0 st3 Entry h 716 37 35 0.193 4.0 Ox0 VIFx 17.3 130.0 st3 lOtchen C 3436 122 148 0.184 6.0 Ox0 VIFx 14.5 140.0 st3 Wng Rm c 3008 99 129 0.161 6.0 Ox0 VIFx 25.8 150.0 st4 Living Rm-A C 3008 99 129 0.154 6.0 OXO VIFX 14.8 170.0 st2 Master Bdnn C 2272 90 98 0.218 5.0 OXO VIFx 25.3 105.0 S1:5 MasterBdnn-A c 2272 90 98 0.182 5.0 Ox0 VIFx 16.0 140.0 st4 Mstr Bath h 1248 65 57 0.169 4.0 OXO VIFx 7.8 160.0 st2 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FIR (fpm) (in) (in) Material Trunk st3 PeakAVF 292 252 0.140 526 8.6 10 x 8 RectFbg st1 st1 PeakAVF 337 268 0.140 607 8.9 10 x 8 RectFbg st2 PeakAVF 442 511 0.154 613 10.4 10 x 12 RectFbg st4 PeakAVF 278 324 0.161 584 8.7 10 x 8 RectFbg st2 sty PeakAVF 90 98 0.218 716 1 5.0 0 x 0 VinlFlx st4 �. + wrightSOft' RlghtSuite® Universe] 2017 17.0.23 RS0009D2 2017-Aug-14 16:48:37 Page 1 ACCiA ...r and Heat,Hibiscus By The Sea, Bid i 4 505.rup Cale = MI8 From Door faces: 8 Return Branch Detail Table Name Grille Size (in) Htg (cfm) CI9 (cfm) TEL M Design FIR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb1 Ox0 779 779 61.5 0.140 558 16.0 Ox 0 VIFx wrightSOft° RIBhtSuite® Unly al 2017 17.0.23 RS000902 AOM ...r and Heat,Hibiscus By The Sea, Bid 1 d 505.rup Calc = M18 Front Door faces: S 2017-Aug-14 16.48:37 Page 2