HomeMy WebLinkAboutPRODUCT INFORMATIONN
CALL 1-800-999-3600
J
w N
w w 38 38'
�WT
Zz
000
W W
Do � •
i
I <
wl`;zi
� 137 I 137
TRAFFIC FLOW "'> 274
0- PLAN VIEW
as 13mm(157)DIA CONDUIT
TO HOUSE OPTIONAL
a CCTV CABLES
SEE VAT 21GX TYPICAL
SCHEMATIC USING ONE-WAY
AND TWO WAY CCTV SYSTEM
FILE NUMBER 178-2055
w
LL
O
W
Q
IL .0--- WSEN
VACUUM AIR TUBE 21GX
CUSTOMER, OPERATOR, CONTROL AND BLOWER DETAILS
C0 ) .
OCUINMOFR —�{
EUNIT
BASE JJ 4-J
L
1
m
N NOTE: r� OF Ci
USED WITH 13485G OPERATOR UNIT UNIT
OR
13483 DUAL SIDED OPERATOR UNIT
SEE PAGE 2AND 30E-8
MAXIMUM TUBE LENGTH 152 METERS
(500 LINEAR FEET)
—13mm (h') CIA. CONDUIT TO HOUSE CONTROL AND AUDIO CABLES
CONTROL CABLE -'GG' CABLE #20 GAUGE STRANDED TINNED COPPER,
7 CONDUCTOR, UNSHIELDED, 300V PPIPVC (19-200216-0062) BY DIEBOLD
AUDIO CABLE -'OD"CABLE#20 GAUGE STRANDED TINNED
`OPTIONAL 13724 (GX)TWO-WAY
CUSTOMER UNIT COLOR CAMERA
0 AND COLOR DISPLAY
L
h11CROPHONE I
i
i
1.�
r
x
.itr*aVac9
+2A'aCV+•9xl
FRONT VIEW `38mm(1 $') OIA. CONDUIT (SEE DETAIL A)!
FOR UNDERGROUND ROUTING OF CONTROL,
AUDIO AND OPTIONAL CCTV CABLES.
45
OF CONDUIT
DETAIL A
J CONTROC AND AUDIO CABLES
O BE RUN UNDER TO UNDER)
IDENTIFICATION PANEL -
NUMBER AND COLOR CODED
TO MATCH OPERATOR UNIT
COPPER,
3 SHIELDED TWISTED PAIRS, INDIVIDUAL FOIL SHIELDS WIT
H DRAIN,
COLOR CODED (91.200170-0062) BY DIEBOLD
`OPTIONAL 13724 (GX)TWO-WAY
CUSTOMER UNIT COLOR CAMERA
0 AND COLOR DISPLAY
L
h11CROPHONE I
i
i
1.�
r
x
.itr*aVac9
+2A'aCV+•9xl
FRONT VIEW `38mm(1 $') OIA. CONDUIT (SEE DETAIL A)!
FOR UNDERGROUND ROUTING OF CONTROL,
AUDIO AND OPTIONAL CCTV CABLES.
45
OF CONDUIT
DETAIL A
J CONTROC AND AUDIO CABLES
O BE RUN UNDER TO UNDER)
IDENTIFICATION PANEL -
NUMBER AND COLOR CODED
TO MATCH OPERATOR UNIT
-
i
i
i
! �JIII
i
i
in y
i
i
i
i
i
i
i
i
i
�I
i
i
i
i
i
i
i
i
i
i
i
n n
10
SIDE VIEW
SIDE VIEW
-
I
A
m
LL
O
N
W
Q
a
CALL 1-BOD-999-3600
PLAN VIEW
FRONT VIEW
VACUUM AIR TUBE 21 GX
13485G OPERATOR UNIT DETAILS
NOTE:
MA%IMUM TUBE LENGTH 152 METERS
(6DS LINEAR FEET)
114..(4 ") DIA. PNEUMATIC TUBE
OPERATOR CONTROL PANEL
��wGENUa a BRING'
'END BUTTON: A MOMENTARY ACTION BUTTON, WHEN
'RESSED BY THE OPERATOR, DISPATCHES THE CARRIER
'O THE CUSTOMER
INFORMATION TECHNOLOGY EQUIPMENT
• UL TESTEOJ01 ETP LO
ULVT4:OFFIC--IAFPUANCVWBUSINESS
EQUIPMENFT, B60RAMTESTSPECIFICATION
UNDERWRITERS LABORATORIES (U
CORPORATE HEADQUARTERS
333 PFINGSTEN ROAD
NORTHBROOK, IL 60062-2696
CUSTOMER CONTROL PANEL X 2
I O SEIN LI `• � I
SEND BUTTON:A MOMENTARY ACTION BUTTON, WHEN
PRESSED BY THE CUSTOMER, DISPATCHES THE CARRIER
TO THE OPERATOR.
BRING BUTTON: A MOMENTARY ACTION BUTTON, WHEN CALL BUTTON: A MOMENTARY ACTION BUTTON, WHEN
PRESSED BY THE OPERATOR, RECALLS THE CARRIER FROM PRESSED BY THE CUSTOMER, ACTIVATES THE AUDIO
THE CUSTOMER UNIT( NOT IN-FLIGHT). CHIME, INDICATING COMMUNICATION IS DESIRED.
POWER SWITCH: TURNS SYSTEM ON AND OFF. BEFORE
SYSTEM IS TURNED OFF CARRIER MUST BE RETURNED
TO OPERATOR UNIT AND OPERATOR DOOR MUST BE OPEN
LOCATION ABOVE AND BELOW CARRIER ACCESS
TYPICAL TRANSACTION
1E CUSTOMER UNIT, WITH DOOR OPEN AND THE
)MER PLACES TRANSACTION INSIDE CARRIER, AND
(LOWERS ENERGIZE AND THE CARRIER IS DISPATCHED
ARRIVAL ATTHE OPERATOR, THE OPERATOR TERMINAL
CUSTOMER UNIT DOOR WILL CLOSE.
UPLETES THE TRANSACTION, THE CARRIER IS PLACED
AL, AND THE SEND BUTTON IS PRESSED. BLOWERS
IER IS DISPATCHED TO THE CUSTOMER. AFTER THE
:USTOMER UNIT, THE CUSTOMER UNIT DOOR WILL
i UNIT DOOR WILL CLOSE.
ALTERNATE
TOR UNIT INSTALLATION
114. (4%) DIA. TUBE
197 32
MULTIPLE UNIT CONFIGURATION
PAD
SIDE VI
PLAN VIEW
(4) UNITS
(2) UNITS
(3) UNITS
wm
J_
� LL
Z Z
00
WW
mN
00
LL
O
M
W
Q
a
Z
1
VACUUM AIR l u6E 21 GX SYSTEM
13660 DUAL SIDED OPERATOR UNIT DETAILS
CALL 1-800-999-3600
114 (4T)DIA OPERATOR CONTROL PANEL
PNEUMATIC TUBE SIDE WITH
i POWER fowl
-- SWITCH(CUSTOMER CONTROL PANEL X 2
v•
--� m SIDE WITH o
-- - r- _..... ...._._.. - ----. _...... n._....._.._.
i '- NO POWER
SWITCH
I
t02 ! 102 SEND BUTTON: A MOMENTARY ACTION BUTTON, WHEN SEND BUTTON:A MOMENTARY ACTION BUTTON, WHEN
PRESSED BYTHE OPERATOR, DISPATCHES THE CARRIER PRESSED BY THE CUSTOMER, DISPATCHES THE CARRIER
(4•) i (4') TOTHECUSTOMER. TO THE OPERATOR.
2M BRING BUTTON: A MOMENTARY ACTION BUTTON, WHEN CALL BUTTON: A MOMENTARY ACTION BUTTON, WHEN
(B•) PRESSED BY THE OPERATOR, RECALLS THE CARRIER FROM PRESSED BY THE CUSTOMER, ACTIVATES THE AUDIO
PLAN VIEW THE CUSTOMER (NOT IN-FLIGHT). CHIME, INDICATING COMMUNICATION IS DESIRED.
POWER SWITCH: LOCATED ONLY ON ONE SIDE OF THE LOCATION ABOVE AND BELOW CARRIER ACCESS
UNIT. TURNS SYSTEM ON AND OFF. BEFORE
i SYSTEM IS TURNED OFF CARRIER MUST BE RETURNED
i TO OPERATOR UNIT AND OPERATOR DOOR MUST BE OPEN.
TYPICAL TRANSACTION
CUSTOMER ARRIVES AT THE CUSTOMER UNIT, WITH THE DOOR OPEN AND THE
CARRIER PRESENT. CUSTOMER PLACES TRANSACTION INSIDE CARRIER. AND
PRESSES SEND BUTTON. BLOWERS ENERGIZE AND THE CARRIER IS DISPATCHED
TOTHEOPERATOR. UPON ARRIVAL ATTHE OPERATOR, THE OPERATOR TERMINAL
DOOR WILL OPEN AND THE CUSTOMER UNIT DOOR WILL CLOSE.
WHEN THE OPERATOR COMPLETES THE TRANSACTION, THE CARRIER IS PLACED
IN THE OPERATOR TERMINAL, AND THE SEND BUTTON IS PRESSED, BLOWERS
ENERGIZE, AND THE CARRIER IS DISPATCHED TO THE CUSTOMER. AFTER THE
CARRIER ARRIVES IN THE CUSTOMER UNIT, THE CUSTOMER UNIT DOOR WILL
OPEN, AND THE OPERATOR UNIT DOOR WILL CLOSE.
ALTERNATE OPERATOR UNIT INSTALLATION
44_, Al(
fl �i
�tstY S'i
229 u
FRONT VIEW SIDE VIEW
PLAN VIEW (2) UNITS
MULTIPLE
PLAN VIEW (3) UNITS
229
SIDE VIEW
PLAN VIEW (4) UNITS
N
CALL 1-800.999-3600
J
NOTE: -
MAX IMUMTUBE LENGTH 152 METERS
(500 LINEAR FEET)
WW
MNOTE:
W CHASE AND LOCATION AS REQUIRED
�u (BY OWNER'S G.C.) SIZED TO HOUSE ALL
Zz INTERCONNECTING CONTROLIAUDIO CABLES
Z Z CHASE
00 413485GVAT21GX
OPERATOR UNIT
w w SHOWN.
as
CIO f(ai
.I III
O n 17 N q
II'I
Wo 1'II
<uit
ow
�a
r a 660
VACUUM AIR TUBE 21GX
TYPICAL DRIVE -UP INSTALLATION USING
TRANSACTION DRAWER AND (1) VAT 21GX SYSTEM
A
DIA
TUBE
235NBE
TRAFFIC
#13486GVAT2IGX
'.r''
(9 )
FLOW
CUSTOMER UNIT
j ..
^ •m n
89mm 3Y.') DIA FLEXIBLE
AIR LINE OR 76mm(3') RIGID
-
PVCTUBING
- -
!
O. I O.'
21
- - (ETRANSACA DRAWER
TRAFFIC
CURB FLOW
PLAN VIEW
OPERATORICUSTOMER UNIT
BLOWER PACKAGES. OWNER'S G.C.
TO PROVIDE SERVICE ACCESS
(LOCATION CAN VARY)
NOTES:
1. ALL WORK AND MATERI
ALSECTRIC CONFORM HI THE MAY BE NAL.APPLICABLE.
FILL
ALL STATE, AND LOCH ELECTRICAL COONS WHICH MAYBE APPLICABLE.
ELECTRICAL CONTRACTOR TO BE RESPONSIBLE FOR My CHANGES
NECESSARY TO COMPLY WRFi THESE CODES.
2. ALL CONDUIT, POWER WIRES, JUNCTION BOXES, AND OVERLOAD PROTECTION
DEVICES, ARE TO BE PROVIDED AND INSTALLED BY ELECTRICAL CONTRACTOR.
cO
LL
O 762m (2'-6') MINIMUM
CLEARANCE HEIGHT
i; „ - REQUIRED TO CONCEAL
Lu,qyg r70mm(2-Y') MIN. TO OBSTRUCTION TUBE RADII AND CLAMPS
Q ({' I TUBE SUPPORT SYSTEM
a1
-------------------------- --
o
_J I40TE:
n- 1 OPERATOWCUSTOMER UNIT - QQ GENERAL CONTRACTOR TO PROVIDE
- .� (_ �! BLOWER PACKAGES (LOCATION „ .N ACCESS TO BLOWER PACK AGE
CAN VARY) nq AND TUBE SYSTEM
zQ !
a� a 7 —_
... I 1/4mm (44z')DI0. CLEAR PLASTIC TUBING
n q I — -)i- -#13485G VAT 21GX
Yy .K iV I OPERATOR UNIT - 2134(7'-D-)STANDARD
SHOWN m� n4.i 3048(1P-O')OPTIDNAL
-
p �A Nm
%�TRANSACTION DRAWER
cj> J1
#13486G VAT 2IGX CUSTOMER UNIT
ts
0 i csl
Z # ALL DIMENSIONS MARKED WITH AN ASTERISK
W MAY VARY WITH BUILDINGfCANOPY CONSTRUCTION
SECTION/ELEVATION
N
O
J
WZ
,0
ZF
40
K0
_O
CALL 1-800-999-3600
TRAFFIC FLI
0
0
m
W
Q
a
n
0
N
m
d
Z
W
J
LL
VACUUM A'.._ TUBE 21GX
13486G CUSTOMER UNIT DETAILS
FIRST LANE OR WALL RECESS INSTALLATION
NOTE:
DETAILS SHOWN ARE FOR VAT 21GX INSTALLATIONS WHERE CUSTOMER'S SITE CONDITIONS REQUIRE THE
CUSTOMER UNIT POSITIONED IN THE FIRST LANE AND/OR AGAINST THE BUILDING WALL
DETAILS SHOWN ARE FOR ILLUSTRATION ONLY AND ACTUAL SITE CONDITIONS MUST BE VERIFIED BEFORE INSTALLATION
SEE SHEET 4 OF 8 FOR TYPICAL DRIVE -UP SCENARIO.
TION
PLAN VIEW - FIRST LANE MINIMUM CURB
1, Am, X-0-1 �x
PLAN VIEW - MINIMUM WALL RECESS
1
®o ` 41022812 VACUUM AIR T.� 21GX CONTROL BOX
AND
BLOWER PACKAGE ASSEMBLY
CALL 1-800-999-3600
TRANSFORMER CABLE -'HH' CABLE
#20 GAUGE STRANDED TINNED COPPER,
2 CONDUCTOR, PVC INSULATION. TWISTED,
WITH SHIELD, 300V (91-200212-0062)
SY DIESOLD
/10 ww �I
Ie V i-z--
w 133
Z
I (5 y-) 1 90
?? PLAN VIEW
V1
Zz
Z
00
H O BLOWER CONTROL CABLE -'HH-CABLE
W w O #20 GAUGE STRANDED TINNED COPPER
g m 2 CONDUCTOR, PVC INSULATION, TWISTED,
cc WITH SHIELD, 300V (91-200212-0062) BY
DIEBOLD
O CONTROL CABLE-'GG'CABLE
#20 GAUGE STRANDED TINNED COPPER
7 CONDUCTOR UNSHIELDED, 300V PPIPVC
(91-200216-0062) BY DIEBOLD
OTRANSFORMER CABLE
J Z n 1628 (6'A')
O AIL W �p�
5`B UIJ �ry
O �g
tFa
FRONT VIEW SIDE VIEW
00
LL
0
O0
LU
0-
a
C ,rom
t 1 y
110k 5
NOTE:
LOCATE IN OPERATORS KNEE SPACE AREA
BACK VIEW
VACUUM AIR TUBE 21 GX CONTROL BOX
pw (g}
ai
_ PLAN VIEW
NOTE:
o;
BLOIL'ER CAN DE MOUNTED VERTICALLY.
ou BLOWER WEIGHT 3.3 kg(7.2 LBS.)
it
s�
(6')
CLEARANCE RECOMMENDED FOR SERVICING BLOWERS
BLOWER CONTROL CABLE -'HH'CA13LE
#20 GAUGE STRANDED TINNED COPPER,
2 CONDUCTOR, PVC INSULATION, TWISTED,
WITH SHIELD, 300V (91-200212-0062) BY DIEBOLD
TO OPERATOR OR CUSTOMER UNIT
POWER CORD 1829mm (6'-0' LONG)
(1)120 VAC, 60 HZ. SINGLE-PHASE (3W),
20 AMP DEDICATED BRANCH CIRCUIT
REQUIRED. MUST BE REMOVED WHEN
UNIT IS HARD WIRED.
-- CLEARANCE
RECOMMENDED
FOR SERVICING
BLOWERS
1'S24mm(5'-0') OF FLEXIBLE CONDUIT TO ALLOW FOR
FRONT VIEW
SERVICEABILITY (BY OWNER'S E.C.). CONDUIT MAY BE REQUIRED
WHEN LOCAL CODES SPECIFY HARD WIRE INSTALLATION.
OWNER'S E.C. TO PROVIDE "DISCONNECT SWITCH TO BLOWER
WHEN HARD WIRED. SEE -CUT SHEET FILE NUMBER 178-2080 FOR
HARD WIRED INSTALLATION REQUIREMENTS.
PERSPECTIVE
(8) 1W,,. (q-) DIA. HOLES FOR
SLOWER HANGERS OR MOUNTING
SIDE VIEW
VACUUM AIR TUBE 21 GX BLOWER PACKAGE ASSEMBLY
WF
ww
m2
wZ
EF
J_ w
� LL
z
z
00
zzww
ZZ
ww
00
00
NJ
I
CALL 1-800-999-3600
BEAM
VACUUM AIR TUBE 21GX
BLOWER PACKAGE MOUNTING DETAILS
7m (Y%20) THREADED
8mm (%,-18)'J' HOOK
LOCAL PURCHASE
SECTION VIEW
DIRECT MOUNTING
WOOD TRUSS OR BEAM
CO
UL
0
8mm
UU 'J' HOOKS
QLOCAL PURCHASE
D_
ki
BLOWER MOUNTING FROM SUSPENDED UNISTRUT
[� �j AND 6mm (1/4'-20) THREADED ROD
�J i = I FUNISTRUT
msl`
®........ .......
1829 mm
(8'-0') LONG
i rC�I CORDS .
emm(9ia) 89 mm(35j')AIRLINE
5'HOOK TO PNEUMATIC TUBE
LOCAL PURCHASE AIR NIPPLE
•J•
8mm („)'S' HOOKS ---
LOCAL PURCHASE
® .................... o e
N O
O / -•
N } O O
J O O9 e o O
Z 89 mm (31T) AIRLINE
TRNIPPLE TIC TUBE
W.AFRONT VIEW
SECTION VIEW
BLOWER MOUNTING FROM SUSPENDED UNISTRUT SUPPORT WITH HANGERS
VACUUM AIR TUBE 21 GX
CONTROL AND AUDIO SCHEMATIC DETAILS
CALL 1-800-999-3600
CONTROL CABLE -'GG' CABLE BLOWER CONTROL CABLE -'HH' CABLE
#20 GAUGE STRANDED TINNED COPPER, 920 GAUGE STRANDED TINNED COPPER,
7 CONDUCTOR, UNSHIELDED, 300V PPIPVC 2 CONDUCTOR, PVC INSULATION, TWISTED
(91-20021E0062) BY DIEBOLD WITH SHIELD, 300V (91-200212-0062) BY DIEBOLD
OPTIONALTUBE
h m HEATER
W W CONTROL CABLE -'GG'CABLE
V #20 GAUGE STRANDED TINNED COPPER,
w 2 7 CONDUCTOR, UNSHIELDED, 300V PPoPV r-- -.-�
F (91-200216-0062) BY DIEBOLD ------------- ------------- - ---------
FLEXIBLE HOSE
u (AIR LINE) '�FLEXIBLE HOSE
? ? (AIR LINE)
BLOWER BLOWER
90 A
CONTROL i PACKAGE PACKAGE
BOX . �.
W W i A ----------
00
1 � i
i
BUILDINGS i AUDIO CABLE •'DD'CABLE
D ELECTRICAL CO AUDIO CONTROL
SUPPLY 420 GAUGE STRANDED TINNED COPPER,
3 SHIELDED TWISTED PAIR INDIVIDUAL
MODULE FOIL SHIELDS WITH DRAIN,COLOR CODED
W451NTERCONNECRNG (91-200170.0962) BY DIEBOLD
CABLE<26IMETERS I OPTIONAL CUSTOMER DOOR RAIL HEATER
(14'-0') (29.016665 oa0A) q i 420 GAUGE STRANDED TINNED COPPER,
2 CONDUCTOR, PVC INSULATION, TWISTED,
Z WITH SHIELD, 300V (91-200212-0062)
CJ�:' 'HH'CABLE BY DIEBOLD
Ow W-U'POWER CORD ( •k p(y•••
1
50 Ff DUAL SIDED
AUDIO SWITCHER BOX J) . UNIT
OPERATOR CUSTOMER
LOCATE IN OPERATORS KNEE SPACE AREA UNIT UNIT
SCHEMATIC FOR CONTROL/AUDIO CABLES OVER TO OVER
NOTE:
OOWNER'S ELECTRICAL CONTRACTOR TO PROVIDE (1 ) DUPLEX OUTLETAT EACH 'A'
ON (1)120 VAC. 60 HZ, SINGLE-PHASE (3W), 20 AMP DEDICATED BRANCH CIRCUIT SEE CUT SHEET FILE NUMBER 178.2080 FOR HARD WIRED
INSTALLATION REQUIREMENTS.
SEE CUT SHEET FILE NUMBER 178-1953 FOR POWER CONSOLIDATION AND
DISTRIBUTION GUIDELINES.
CONTROL CABLE -'GG' CABLE CONTROL CABLE-'GG'CABLE BLOWER CONTROL CABLE -'HH'CABLE
7 CONDGE UCTOR.
UNOEDTWNEO COPPER, 020 GAUGE STRANDED TINNED COPPER, #20 GAUGE STRANDED TINNED COPPER.
LL 7 CONDUCTOR• UNSHIELDED, 300V PPIPVC 7 CONDUCTOR, UNSHIELDED, 300V PPIPVC 2 CONDUCTOR, PVC INSULATION, TWISTED
LL (91-200218-0062) BY DIEBOLD
0 (91-200216-0D62)BY DIEBOLD WITH SHIELD, 300V (91-200212-0062)BY DIEBOLD
_ OPTIONAL TUBE
HEATER
W _ r-
QFLEXIBLE HOSE _ _ _._._._._._._ _._._ _ _ _
(AIRLINE)
i
•
FLEXIBLE HOSE
CONTROL BLOWER BLOWER 1 (AIRLINE)
R i PACKAGE PACKAGE i
Box Q-4- A ��
.�---Btfi AU010
BUILDINGS -- - CONTROL
ELECTRICAL �. ryl MODULE
SUPPLY
SUPPLY
CABLE-1267 METERS
(14'-DT(29.01686S000A)
B'-0' POWER CORD
OPTIONAL CUSTOMER DOOR RAIL HEATER
420 GAUGE STRANDED TINNED COPPER,
2 CONDUCTOR, PVC INSULATION, TWISTED,
WITH SHIELD, 300V (91-200212-0062)
'HH' CABLE BY DIEBOLD
•]� RELOCATION IN CANOPY. OPTIONAL
LOCATION IN OPERATORS KNEE SPACE
AREA
.61 ` AL SI ....,9Q,
OR AAA 1111,11
DUAL SIDED
UNIT
O�RATORUNII '-
E CON
—AUDIO SWITCHER BOX
AUDIO CABLE -'DD' CABLE
#20 GAUGE STRANDED TINNED COPPER,
3 SHIELDED TWISTED PAIRS, INDIVIDUAL
FOIL SHIELDS WITH DRAIN, COLOR CODED
(91-2001760062) BY DIEBOLD
CUSTOMER
.]( 38mm(1h') CONDUIT REQUIRED UNIT
LOCATE IN OPERATORS KNEE SPACE AREA (1) PER CUSTOMER UNIT
SCHEMATIC FOR CONTROL/AUDIO CABLES UNDER TO UNDER