-. it Product Approval
}4 e y4,�Yi� USER: Public User
L�-S.>o-eJn'gv
Product Approval Heru> Produrt or Aoolicabon search > Aoppcation Ust> Application Detail
FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed
the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
FL1654-R2F
Revision
2014
Approved
G
POLYGLASS USA
150 Lyon Drive
Fernley, NV 89408
(570) 384-1230 Ext 242
jakins@polyglass.com
James Akins
jakin@polyglass.com
SCANNED
BY
St. Lucie County
THESE PLANS AND ALL PROPOSED WO%''(
ARE SUBJECT TO ANY CORRECTIONS
' RLGUIRED BY FIELD INSPECTORS THAT
MAY BE NECESSARY IN ORDER TO
C0I aPLYWITH ALL APr UCAME CMES,
Maury Alpert
lilt W. Newport Center Drive
Deerfield Beach, FL 33442
(912) 429-8610
MAlpert@polyglass.com
James Akins
555 Oakridge Road
Humboldt Industrial Pkwy
Hazleton, PA 18201
(800) 894-4563
jakins@polyglass.com
Roofing
Modified Bitumen Roof System
COOLED FASTWO OnArrACHmirs
ARE TOE RESPQNSIBM OF THE
0QNNiA=0FRECORD
ST. LUCIE COUNTY
BUILDING DIVISION
REVIEWED
FOR COMPLIANCE/
DATE
MUST -BE KEPT ON'JOB OR
NO INSPECTION WILL BE MADE
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
L Evaluation Report - Hardcopy Received
Robert Nieminen
PE-59166
UL LLC
10/06/2018
John W. Knezevich, PE
W Validation Checklist - Hardcopy Received
FL1654 R21 COI 2017 01 COT Nieminen.odf
Standard
year
ASTM D6162
2000
ASTM D6163
2000
ASTM D6164
- 2005
ASTM D6222
2008
ASTM D6509
2009
FM 4470
1992
FM 4474
2004
http://v, ww.floridabuilding.org/pr/pr_app_dtI.aspx?param=wGEVXQwtDgvgqu2wb/D2bnF... 8/21/2017
Florida building Code Onlin Page 2 of 2
UL 1897
2008
Equivalence of Product Standards
Certified By
Sections from the Code
THESE PLA-NS AND ALL PROPOSCO VdcRK
ARE SUBJECT TO ANY COPRECi7CN5
`�OUIRED
Product Approval Method
Method 1 option D
BY FIELD INSPECTORS THAT
Date Submitted
06/01/2017
fill -AY BE IiecESSARY IN OPtDC-rfq TO
Date Validated
06/08/2017
CO"41V WITH ALL APPLICABLE CODES.
Date Pending FBC Approval
06/14/2017
Date Approved
08/08/2017
Summary of Products
F. 1
FL #
Model, Number or Name
Description
1654.1
Polyglass SBS and APP
SBS and APP modified bitumen roof systems
Modified Bitumen Roof
Systems
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL1654 R21 11 2017 05 FINAL Al ER POLYGLASS MODBIi FL16 4-
R21.odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Robert Nleminen PE-59166
Design Pressure: +N/A/-622.5
Created by Independent Third Party: Yes
Other: 1.) The design pressure in this
Evaluation Reports
application relates to one particular assembly
FL1654 R21 AF 2017 05 FINAL FR POLYGLASS MODBIT FL1654-
R221 od
over concrete deck. Refer to the ER Appendix for
other systems and deck types. 2.) Refer to. ER,
Created by Independent Third Party: Yes
Section 5 for other Limits of Use.
Back F.amr
Conrad Us :: 2601 Blair Stone Road, Tallahassee Fl, 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employe, Copyright 2007-2013 state of Florida.:: Privacy Statement:: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public reports. If you do not want your a -mall address released in response to a public -records request, do not send
electronic mall to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395.'Pursuant to
Section 455.275(1), Florida Stau tea, effective October 1, 2012, licensees licensed under chapter 455, F.S. must provide the Department with an email address If
they have one. The malls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to
supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under
chapter 455, F.S., please Click here .
product Approval Accepts:
MIT99 ® 99 I
Credit Card
Safe
9 y
t
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgvgqu2wd/b2bnF... 8/21 /2017
r
Wi.J. I0, tf�� 4 f.
V I KININ I ERD
Table
Deck
Application
Type
Description
Page
_ SA
Wood
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
5
113-1
Wood
New or Reroof (Tear -Off)
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
5-9
1B-2
Wood
New, Reroof (Tear -Off) or Recover
A-2
Mech. Attached Anchor5heet, Bonded Insulation, Bonded Roof Cover
30-11
IC
Wood
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover -
11
12-13
3E Wood New, Reroof (Tear -Off) or Recover D Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover 14-15
1F-1 Wood New or Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet (nails), Bonded Roof Cover I6-18
1F-2 Wood New, Reroof (Tear-Offl or Recover E Non -Insulated. Mech. Attached Base Sheet (screws & Dlatesl. Bonded Roof Cover 19-21
1G
Wood
New or Reroof (Tear -Off)
F
Non -Insulated, Bonded Roof Cover
21
2A
Steel cr5tructural concrete
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
22-24-
2B
Steel or5tructural concrete
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
25-28
2C
Steel or5tructural concrete
New, Reroof (Tear -Off) or Recover
D
Prelim. Attached Insulation,Mech. Attached Base Sheet, Bonded Roof Cover
29-31
3A
Structural concrete
New or Reroof (Tear -Off)
A-1
Banded Insulation, Bonded Roof Cover
32-39
3B
Structural concrete
New or Reroof (Tear -Off)
F
Non -Insulated, Bonded Roof Cover
39
4A
LWIC
New or Reroof (Tear-Off1
A-1
Bonded Insulation. Bonded Roof Cover
40-41
4B
LWIC
New or Reroof (Tear -Off)
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
42
4C
LWIC
New or Reroof (Tear -Off)
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
43-45
SA
CWF
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
46
5B
CWF
New, Reroof(Tear-Off)or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
47
5C
CWF
New, Reroof (Tear -Off) or Recover
B
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
48
50
CWF
New, Reroof (Tear -Off) or Recover
C
Mech. Attached Insulation, Bonded Roof Cover
48
SE
CWF
New, Reroof (Tear -Off) or Recover
E
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
48
6A
Gypsum
Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
49-51
6B
Gypsum
Reroof (Tear -Off) or Recover
A-2
Mech. Attached Anchor5heet, Bonded Insulation, Bonded Roof Cover
51
6C Gypsum Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 52
6D Gypsum Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 52
7A Various Recover A-1 Bonded Insulation, Bonded Roof Cover 53-56
7B Various Recover F Non -Insulated, Bonded Base Sheet, Bonded Roof Cover 56
The following notes apply to the systems outlined herein:
1. The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation.
2. Insulation / base sheet fasteners shall be of sufficient length for the following deck engagement:
➢Wood: Minimum 0.75-inch penetration.
D Steel: Minimum 0.75-inch penetration and engage the top flute of the steel deck.
D Structural concrete: Minimum 1-inch embedment into pilot hole in accordance with fastener manufacturers published installation instructions.
3. Unless otherwise noted, insulation may be any one layer or combination of po lyisccya nu rate, polystyrene, wood fiberboard, perlite, gypsum -based roof board or mineral -wool roof board that meets the OA
requirements of F.A.C. Rule 63G20-3 and is documented as meeting FBC 1505.1 and, forfoam plastic, FBC Chapter 26, when installed with the roof cover.
Exterior Research and Design, LLG d/b/a Trinity I ERD Evaluation Report P9290.02.08-R19 for FL3654-RZ1
Certificate of Authorization d9503 FBC NON.HVHZ EVALUATION Revision 19: 05/30/2017
Prepared by: Robert Nleminen, PE-59166 Polyglass USA, Inc.; (570) 384-1230 Appendix 1, Page 1 of 56
`,.l I KINITY ERD
Minimum 200 psi, minimum 2-inch thick lightweight insulating concrete may be substituted for rigid insulation board for System Type D (mechanically attached base sheet, bonded roof cover), whereby the base
sheet fasteners are installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal a greater configuration to the steel and concrete deck listings. Roof decks and
structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC
Approval documentation.
Unless otherwise noted; insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturers published instructions.
➢ Hot asphalt (HA): Full coverage at 25-30 lbs/square.
➢Dow lnsta-Stik Roofing Adhesive(D-IS): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c.
➢ Millennium One Step Foamable Adhesive(M-OSFA): Continuous 0.25 to 0.5-inch wide ribbons, 12-inch o.c.
➢ Millennium PG-1 Pump Grade Adhesive (M-PG3): Continuous 0.25 to 0.5-inch wide ribbons,12-inch o.c.
➢ OMG OlyBond 500 (OB500): Continuous 0.75 to 1-inch wide ribbons,12-Inch o.c. (PaceCart or SpotShot). Note. OlyBond Green maybe used where O1yBond500 is referenced.
D OlyBond Classic (OB Classic): Full coverage at 1 gal/square.
➢ ICP Adhesive & Sealants CR-20: Continuous 2.5-3.5-inch wide ribbons, 12-inch ox.
➢ Note: When multiple layers(s) of insulation and/or caverboord are installed in ribbon -applied adhesive, board joints shall be staggered.
D Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing.
Unless otherwise noted, all insulations are flat -stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum
Design Pressure (MDP) limitations. In no case shall these values be used to 'increase' the MOP listings in the tables; rather if MDP listing below meets or exceeds that listed for a particular system in the tables, then
the thinner board listed below may be used as a drop -in for the equivalent thicker material listed in the table:
D Millennium One Step Foamable Adhesive (M-OSFA): MOP -157.5 psf (Min. 0.5-inch thick)
➢Millennium PG-1 Pump Grade Adhesive(M-PGS): MDP -157.5-psf (Min. 0.5-Inch thick)
➢ OMG OlyBond 500 (OB500): MDP -87.5 psf (Min. 0.5-inch thick Multi -Max FA-3) � �
➢ OMG OlyBond 500 (0B500): MDP -315.0 psf (Min. 0.5-inch thick ISO ENRGY )
E CLAwy
➢ OMG OlyBond 500 (OB500): MDP -315.0 psf (Min. 0.5-inch thick ENRGY 3)
D OMG OlyBond 500 (OB500): MDP -487.5 psf (Min. 0.5-inch thick ACFoam II)
D ICP Adhesives &Sealants CR-20: MDP -117.5 psf (Min. 1.0-inch thick)16
7. Bonded polyisocyanurate insulation boards shall be maximum 4 x 4 ft.
S. For mechanically attached components or partially bonded Insulation, the maximum design pressure for the selected. assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC
Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD-1, FM Loss
Prevention Data Sheet 1-29, RAS 117 and RAS 137. Assemblies marked with an asterisk' carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3
enhancements.
9. For fully bonded assemblies, the maximum design pressure forthe selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16, and no rational analysis is permitted. J
10. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the
minimum requirements for the system. Testing and analysis shall be in accordance with AN51/SPRI FX-1 or TAS 105.
11. For existing substrates in a bonded recover installation, the existing roof system shall be examined for compatibility and bond performance with the selected adhesive, and the existing roof system shall be capable of
resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing In accordance with AN51/SPRI IA-1, ASTM E907, FM Loss
Prevention Data Sheet 1-52 or TA5124.
12. For Recover Applications using System Type D, the insulation is optional; however, the existing roof system shall be suitable for a recover application.
13. LWIC shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWIC is referenced, refer to current LWIC Product Approval for specific deck
construction and limitations. For systems where specific LWIC is not referenced, the minimum design mix shall be 300 psi. In all cases, the minimum top -coat thickness is 2-inches. For LWIC over structural concrete,
reference is made to FBC Section 1917.4.1, Point 1.
Exterior Research and Design, U.C. d/b/a Trinity ERD Evaluation Report P9290.02.08-1139 for FL3654-R21
Certificate of Authorization h9503 FBC NON-HVHZ EVALUATION Revision 19: 05/30/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass USA, Inc.; (570) 384-1z3D Appendix 1, Page 2 of 56
-JTRINITYI ERD
14. Unless otherwise noted, refer to the following references for bonded base, ply or cap sheet applications.
TABLE I: POLVGLASS ROOF COVERS
Reference
Layer
Material
Application
BP -AA
Base Ply
One or more plies Polyglass G2 Base, FBC Approved ASTM.D4601, Type II
Hot Asphalt at 20-40
(Base and Ply sheets, Asphalt-
Ply
One or more plies Polyglass PI IV, Polyglass Ply VI, FBC Approved ASTM D2178, Tye IV or VI
Applied)
Note:
Asphalt -applied sheets or insulation shal/notbe applied to poly -film surfaced membranes.
Ibs/square
Base Ply
One ply Elastobase (sand/sand), Elastoflex V, Elastoflex S6, Elastoflex S6 Type It, Polyglass HT Base 650
PG350 at 1.5-2.0
SBS-CA1
Cap Ply
Elastoflex VG, Elastoflex VG FR, Elastoflex 56, Elastoflex 56 Type II, Elastoflex S6 G, Elastoflex S6 G FR, Elastoshield T5-G, Elastoshield
gal/square
TS-G FR, Polyfresko G SBS (sand -backed), Polyfresko G SBS FR (sand -backed)
Base Ply
One ply Elastobase (sand/sand), Elastoflex V, Elastoflex 56, Elastoflex S6 Type II
Polyplus 35 at 1.5-2.0
SBS-CA2
Cap Ply
Elastoflex VG, Elastoflex VG FR, Elastoflex S6, Elastoflex S6 Type II, Elastoflex S6 G, Elastoflex 56 G FR, Elastoshield TS-G, Elastoshield
gal/square
TS-G FR, Polyfresko G SBS (sand -backed), Polyfresko G SBS FR (sand -backed)
Base Ply or Ply
One or more plies Elastobase (sand/sand or poly/sand), Elastobase P (sand/sand or poly/sand), Elastoflex V, Elastoflex 56, Elastoflex
56 Type II, Polyglass HT Base 650
SBS-AA
(SBS, Asphalt -Applied)
Cap Ply
Elastoflex V, Elastoflex VG, Elastoflex VG FR, Elastoflex 56, Elastoflex 56 Type II, Elastoflex 56 G, Elastoflex 56 G FR, Elastoshield TS-G,
Hot Asphalt at 20.40
Ibs/square
Elastoshield TS-G FR, Polyfresko G SBS (sand -backed), Polyfresko G SBS FR (sand -backed)
Note:
Asphalt -applied sheets or insulation shall not beapplied to poi-flm surfaced membranes.
Base Ply or Ply
or more plies Elastobase (sand/poly), Elastobase (poly/poly), Elastoflex V, Elastoflex 56, Elastoflex S6 Type 11, Polyglass HT Base
6
SBS-TA
0
(SBS, Torch -Applied)
Elastoflex V, Elastoflex VG, Elastoflex VG FR, Elastoflex S6, Elastoflex 56 Type II, Elastoflex 56 G, Elastoflex S6 G FRI, Elastoshield TS-G,
Torch -Applied
Cap Ply
Elastoshield TS-G FR, Polyfresko G SBS (poly -film backed), Polyfresko G SBS FR (poly -film backed)
Base Ply
One or more plies Elastoflex SA V Base, Elastoflex SA V FR Base, Elastoflex SA V Plus, Elastoflex SA V Plus FR
SBS-SA
Cap Ply
Elastoflex SA P, Elastoflex SA P FR, Polyreflect
Self
(SBS, Self -Adhering)
Unless otherwise noted, permissible membrane substratesfor SBS-SA are limited to the SUS -SA Base Ply options herein,
-Adhering
Note:
Elastobase (poly/sand) or Elastobase (poly/poly).
APP-CAS
Cap Ply
Polyflex G FR
PG350 at 1.5-2.0
gal/square
APP-TA
Base Ply or Ply
One or more plies Polyglass APP Base, Polyflex, Polybond
Torch -Applied
(APP, Torch -Applied)
Cap Ply
Polyflex, Polyflex G, Polyflex G FR, Polybond, Polybond G, Polyfresko G, Polyfresko G FR
Cap Ply
Polyflex SA P, Polyflex SA P FR, Polyfresko G SA, Polykool
APP SA
(APP, Self -Adhering)
Note:
Unless otherwise noted, permissible membrane substratesforAPP-SA are limited to the SBS-SA Base Ply options herein,
Self -Adhering
Elastobase 1poly/sand) or Elastobase /poly/poly).
15. Any of the following FBC Approved coatings may be applied to the top roof membrane without adverse effect on the system wind load performance,
associated with coating usage.
Y PG200 Non Fibered Roof Coating;
Y PG300 Fibered Roof Coating;
➢ PG600 Non-Fibered Aluminum Roof Coating;
Y PG650 Fibered Aluminum Roof Coating;
➢ PG700 High Quality Elastomeric Roof Coating or KM Acryl 25;
Y' PG700QS(Quick Set) High Quality Elastomeric Roof Coating or KM Acryl 25-QS(for granule -surfaced APP or SBS only);
Y PG800 Asphalt Emulsion RoofCoating;
Y Palyplus 60 Premium Nan-Fibered Aluminum Roof Coating;
Y Poiyplus 65 Premium Fibered Aluminum Roof Coating;
• Polybrite 70 Premium Grade Elastomeric Roof Coaling or KM Acryl 15;
Y Polybrite 70QS(Quick Set) Premium Grade Elastomeric Roof Coating or KM Acryl 15-Q5(for granule -surfaced APP or SBS only);
Y Polybrite 90 High Solids Silicone Roof Coating or Polybrite 95 Silicone Roof Coating.
Exterior Research and Design; I.I.C. d/b/a Trinity I ERD
Certificate of Authorization A9503 FBC NON-HVHZ EVALUATION
Prepared by: Robert Nieminen, PE-59166 Polyglass USA, Inc.; (570) 384-1230
Refer to current Roofing Materials Directory for fire ratings
114�
� O64NR
...•, l
Evaluation Report P9290.02.08-R19 for FL3654-R21
Revision 19: 05/30/2017
Appendix 1, Page 3 of 56
\JTRINITY ERD
16. Dens Deck shall he field -primed with PG100 prior to self -adhering membrane application. Refer to tables herein for other priming requirements.
17. Vapor barrier options for use over structural concrete deck followed by adhered insulation carry the following Maximum Design Pressure (MDP) limitations. The lesser of the MDP listings below vs. those in Table 3A
applies:
VAPORBARRIEROPTIONS;STRUCTURALCONCRETEDE
Kf ANNEREDINSIIIATIONPERTA8U3A
Option #
Primer
Vapor Barrier
Insulation Adhesive
MDP (psf)
Type
Attach
VB-1.
P6100
Elastoflex SAV Plus
Self -Adhering
Inta-Stik or CR-20, 12-inch o.c.
-60.0
VB-2.
PG100
Polyglass APP Base
Torch -applied
Inta-Stik or CR-20,12-inch o.c.
-75.0
VB-3.
PG100
Elastoflex SAP
Self -Adhering
Insta-Stik, 12-inch o.c.
-75.0
VB-4.
PG100
Elastoflex SA P
Self -Adhering
Millennium One Step Foamable Adhesive, 12-Inch o.c.
-157.5
VB-5.
PG100
Elastoflex SA P
Self -Adhering
CR-20, 12-inch mc.
-270.0
VB-6.
PG100
Elastoflex SA V Base, Elastoflex SA V FR Base,
Elastoflex SA V Plus, Elastoflex SA V Plus FR
Self -Adhering
Millennium One Step Foamable Adhesive, Millennium PG-1 Pump Grade
Adhesive, OlyBond 500 or CR-20, 12-inch o.c.
-290.0
18. "MDP". = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads.
W
Zml
IV 1 �
Exterior Research and Design, U.C. d/b/a TrinitylERD Evaluation Report P9290.02.08-1319 for FL1654-R21
Certificate of Authorization #9503 - FBC NON-HVHZ EVALUATION Revision 19: 05/30/2017
Prepared by: Robert Nieminen, PE-59166 Polyglass USA, Inc.; (570) 384-1230 Appendix 1, Page 4 of 56
�, �TRINITYJERD
TABLE: IF-2:, WOOD DECKS-, NEW CONSTRUCTION, REROOF(TEAR�-OFF) OR: RECOVER"
—
4 SYSTEM TYPE E; NON -INSULATED, MECHANICALLYATTACHED:BASE SHEET (SCREWS &PLaTrs),BONDED ROOF COVER !:�.^"
' - •-
`'
System
Deck (Note 1)
Base Sheet
Roof Cover (Note .14)
MOP
No.
Type
Fasten
Attach
Base Ph/
Cap
(ps
SELF-AuHERiNG BASE PLY:
W-136
Min. 19/32-
Elastobase, Elastobase P
Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast 014
12-inch o.c. in 4-inch lap and 12-inch o.c in two
SBS-SA, APP-SA, SBS_
Inch plywood
(poly -film top)
or Trufast 3" Metal Insulation Plate with Trufast HD
(2), equally spaced, staggered center rows
SBS-SA
TA APPTA
-52.5-
W-137
Min. 19/32-
Elastobase, Elastobase P
Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with Dekfast 014
12-inch o.c. in4-inch lap and 12-inch o.c in two
inch plywood
(poly -film top)
or Trufast 3" Metal Insulation Plate with Trufast HD
(2), equally spaced, staggered center rows
Polyflex SA Base
APP-TA
-52.5•
W-138
Min. 19/32-
Elastobase, Elastobase P
OMG Flat Bottom Plates (square) with Roofgrip 412
12-inch o.c. in 4-inch lap and 12-inch C.C. in two
SBS-SA
SBS-SA, APP-SA, SBS-
-60.0•
inch plywood
.(poly -film top)
(2), equally spaced, staggered center rows
TA, APP-TA
W-139
Min. 19/32-
iElastobase, Elastobase P
OMG Flat Bottom Plates (square) with Roofgrip q12
12-Inch o.c. in 4-inch lap and 12-Inch o.c. in two
poly0ez SA Base
APP-TA
-60.0'
inch plywood
',(poly -film top)
(2), equally spaced, staggered center rows
.: TABLEIG; WOOD DECKS -NEW CONSTRUCTION OR REROOF,(TEAR-OFF)
-
' SYSTEM TYPE F:NON-INSULATED, BONDED ROOF COVER
System
Deck (Note 1)
Primer
Roof Cover (Note 141
MOP (psQ
Joint Treatment
Base Ply
Ply
Cap Ply
No.
W-140
Min. 15/32-
None
None
SBS-SA
(Optional) SBS-SA,SBS-
SBS-
TAS-ASAPTPAP-SA,5B5-
-90.0
inch plywood
Min. 15/32-
W-141
inch plywood
(Optional)PG100
None
PolyFlez SA Base
(Optional)APP-TA
APP-TA
-90.0
W 142
Min. 15/32-
pG100
None
SBS-SA
(Optional)SBS-SA, SBS-
SBS-SA, APP-SA, SBS-
-97.S
Inch plywood
TA, APP-TA
TA, APP-TA
W-143
Min. 15/32-
(Optional) PGI00
Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus, rolled into
Elastoflex SA V Base or
(Optional) SBS-SA, SBS-
SBS-SA, APP-SA, SBS-
inch plywood
place to create continuous bond.
Elastoflex SA V FR Base
TA, APP-TA
TA, APP-TA
-97'S
W 144
Min. 15/32-
WB-3000
None
SBS-SA
(Optional)
SBS-SA, APP-SA, SBS-
-105.0
inch plywood
TA, APP-TA
W,15
Min. 15/32-
jDptional)PGI00
Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus, rolled into
Elastoflex SA V Plus or
(Optional)SBS-SA, SBS-
SBS-SA, APP-SA,SBS-
inchplywood
place to create continuous bond.
Elastoflex SA V Plus FR
TA, APP-TA
TA, APP-TA
-135.0
W-146
Min. I5/32-
(Optional)PGS00
Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus, rolled into
Polyflex SA Base
(Optional) APP-TA
APP-TA
-135.0
Inch plywood
place to create continuous bond.
- s,✓A ,�s a -'r�, N
Exterior Research and Design, ULC. d/b/a Trinity) ERD Evaluation Report P9290.02.08-1119 for F1.3654-1121
Certificate of Authorization 49503 FBC NON-HVHZ EVALUATION Revision 19: 05/30/2017
Prepared by: Robert Nieminen, PE-59166 PoWlass USA, Inc; (570) 384-2230 Appendix 1, Page 21 of 56
kyle � �S
(oacb A(A jeyu5 t
MEASUREMENTS 4
SQUARES
Actual Squares: 124.32 Sqs.
Total Squares
(Inc. Waste at 2 %): 126.81 Sqs.
PITCH MEASUREMENTS
Pitch 0/12: 42.00 Sqs.
Pitch 6/12: 82.32 Sqs.
y/
LINE MEASUREMENTS
Eaves:
Rakes:
Ridges:
Hips:
Valleys:
Step:
Wall:
Pitch Change:
a�
CATEGORY MEASUREMENTS
Ice & Water Shield:
Ridge Vent:
Rake Edge:
Eave Edge:
Step Flashing:
Apron Flashing:
Gutters:
Gutter Toppers:
Down Spouts:
555 Ft.
0 Ft.
0 Ft.
0 Ft.
0 Ft.
0 Ft.
230 Ft.
0 Ft.
0 Ft.
0 Ft.
0 Ft.
0 Ft.
0 Ft.
0 Ft.
0 Ft.
0 Ft.
0 Ft.
1Him
..
61