HomeMy WebLinkAboutPRODUCT APPROVALlorida Building Code Online
httpsJ/www.floridabuilding.org/pr/pr app_ d.aspx?parem---vGEVX...
Y"I
)
BCS Rome W9N usv Repahatbn
wts,L SW�K9vtl n�9a 9atza.FaGs PtlWbrs
rEC�R �Sellap Ills "eaUi
pi 7fcd
4 Product Approval
vma�staamorai Renu>vma=o.a rcrn.��i>a�>nwecalwn}�miy>wtms�venocna
SCANNED
FL #
F, 3B9 RB
Application Type
Revision
BY
Code Version
2014
St. Lucie
Status
Approved
oution
County
n ty
Comments
Archived
Product Manufacturer American Shutter Systems Association, Inc.
Address/Phone/Email 4268 Westroads Drive
West Palm Beach, FL 33407
(561) 209-8263
bfeeley@eastemmetal.com
Authorized Signature Bill Feeley
Irodrig uezOeastemmetal.mm
Technical Representative
Address/Phone/Email
Quality Assumnce Representative
Address/Phone/Email
Category Shutters
Subcategory Accordion
Compliance Method Evaluation Report from a Florida Registered Arched: or a Licensed Florida Professional
Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Evaluation
Walter A.. TBFrt, Jr. P.E.
Report
Florida License
PE-44167
Quality Assurance Entity
National Accreditation and Management Institute
Quality Assurance Contract Exptration Date
12/31/2017
Validated By
John W. Knezevich, PE
Validation Cheddist - Hankopy Received
Certificate of independence FL389 R8 C,CQRDIONCI NONHVHV Z.9df
Referenced Standard and Year (of Standard) Standard Year
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
ASTM E-1886 2005
ASTM E-1996 2005
ASTM E-330 2002
TAS 201, 202, 203 1994
Method 1 Option D
04/29/2015
04/29/2015
05/07/2015
of 2 7/9/17.3:34 PM
Florida Building Code Online
- --
httpsJ/www.floridabuildi i org/pr/pr_app_dtl.aspx?param=wGEVX...
e
Date Approved
summary of Products
06/22/2015
._ _..________.._____._--__—,.
!.FL#Model, Number or Name
!Description_______.
389.1 i Bertha HV Accordion Shutter- Blade 3 - (Non-
i Extruded aluminum interhodring blades retained by tracks (top and bottom) for
; HVHZ) -Onv915-086
istorm protection
FALfimits oUse
P Installation Instructions
pprovedfor use lnHVHZ: No
1 FL389 RB II A.S.S.A. INC. DRWG.15-086.odf
Approved for use outside HVHZ: Yes
i Verified By: American Test lab of South Rodda Inc
Impact Resistant: Yes
y treated by Independent Third Party: Yes
! Design Pressure: N/A
`Evaluation Reports
f Other. Large Missile Level °D'.Max Span Is 12=T for 35 psf positive ASD load
i FL3@Q�BgE A S.S.A INs,_p E.R. O�WG 15-08S.Gdf
and 13'-0" for 35 psf negative ASD load the HV3 blade w/o window blade.5' 2'
Created by Independent7hlrd Parry: Yes
! for 110 psf ASD load for HV3 blade w/e window blade and S' 11' for 62 psf,
E
! 9'-6" for 55 psf HV3 blade w/window blade working in unLmn.Maxspan for HV3
blade w/o window blade for installations into Metal Stud walls is 79" for max.
i
ASD pressure rating of +72; 72 and 84" for +64,-64 psf. See sheet 5 for other
j
spans and ASD Pressures.
389.2 ,E Bertha HV Accordion Shutter -Blade 1 only-
i Extruded aluminum intedortang blades retained by trucks (top and bottom) for j
(Non-HVHZ)- Dnvg 15-085
shorn protection
i
Limits
rs of Use
LrstallaHun Lrstroctions
Approved far use In HVHZ: No
3�L 89 RB II A 5 S A INC. DRWG.15-0BS.otlf
Approved for use outside HVHZ: Yes
Verified By: American Test Lab of South Florida Inc.
Impact Resistant: Yes
i Created by Independent Third Parry: Yes
Design Pressure: N/A
(Evaluation Reports
Other: Large missile level ^D". Mm6 Span Is 16'-0" for 30 p.s.f negative ASO
! FL389 R8 AE A S 5 A INC. P.E.R. DRWG. 15-085 HV pdf
load depending on centermates and locking red configuration for the HVi blade,
f Created by Independent Third Party: Yes
! 8'-0" for+64, -72 p.s.t load for My blade for Keystmre mountings 7'-G' for+75,'i
75 p.s.f. for metals stud mountings and 8'-0" for 110 p.s.t for HV3 and HVIA
1
working in unison. See sheets 7, 11 and 20 respectively of installation drawlngs
for other spans and pressures. r
i
'Bertha HV Accordion Shutter -COMBO- (Non-
i Extruded aluminum imedi cking blades retained by trails (fop and bottom) for
INHZ} Drwg 15-084;i
rLIMIts
sura protection
of Use`___.__.__________�__.__._____.__.___`
Approved for use in NVXZ: No
Installation Instructions
( FL389 R8 II A S S A. INC. DRWG.15-0,$4.pd
Approved for use outside HVHZ: Yes
i verified By: American Test Lab of South Florida lmc
Impact Resistant: Yes
Created by Independent Third Party: Yes !
Design Pressure: N/A
L Evatuadott departs !
Other: Large missile. Max. 16'-0'span at 30 psf ASD load for Blade 1 and
ii389-RE A.S-S-BLJPC. PER DRWg-lE- B4.ndf i
IB'-0_for Blade 2. See schedules on sheet 12, 25 and 28 respectively_T _-_i
Created by Independent Third Party: Yes
Wwu fb4tla imu, ethos am.
pho�a or Ey traatm nal mai.
povme Me pe oa la ,
pvsor�al aNgs,
533�,q
a Ce mob: avaewk to tie puff.
]NOYA�pp�imi�L l� Ilc
Credit Card
Safe
aEa
Mt W"ws ,ya
of 2