HomeMy WebLinkAboutPLANCONTRACTOR: Jensen Br ,lumiumn
DESIGN CRITERIA:
Applicable Codes. Regulations, and Standards
1. The 6th Edition (2017) Florida Building Code, specifically Chapter
16 Structural Design, Chapter 20 Aluminum, and Chapter 23 Wood.
2. ASCE 7-10.
Wind Loads
1. Building Occupancy Category, Paragraph 1604.5 and Table 1604.5:
Risk Category 3.
2. Basic Wind Speed, Table 1609C, State of Florida Debris Region &
Basic Wind Speed, Paragraph 1609.3 an 1609.3.1
Equivalent Basic Wind Speed: Vutr=' VAsD=126
MPH.
3. Exposure Category, Paragraph 1609.4.3u=
Replacement of (3) Glass Windows.
1. Windows or doors not within 20 feet from comers.
Builder / Permit Application is to provide Florida Product Approvals
meeting required design pressures.
OPENING SCHEDULE
MARK
SIZE (W"xH")
MANUFACTURER
SERIES #
APPROVALS
DESIGN PRESSURES
ALLOWABLE PRESSURES
Qj
8"
1_ARGE MISSILE IMPACT)
S iM5
+30-0f�P_S�
Q375�4'[5t
=(LARGE MISSILE IMPACT)
-F1t139 25
1 _.�=;4
�.
Q3
rf1Q OYrX3_`��`0'�ki0_*_t,
P. _ I STR) 5
700 ULLION
sr267=R11
30s7�T33 ESF