Loading...
HomeMy WebLinkAboutDESIGN AND SPECIFICATIONRADON MITIGATION SYSTEM DESIGN AND SPECIFICATIONS Owner: BR Carroll St. Lucie, LLC 7700 Pine Lakes Blvd SCANNED Port St. Lucie, FL 34952 BY St. Lucie County PROPERTY NAME = ARIUM PINE LAKES APARTMENTS Lucia 5?jijh( Job Address = 7245 Pine Lakes Blvd, Port St. FlU 9 cupv Contents M1 = Radon Mitigation System Diagram (1 Bed / I Bath) M2 = Radon Mitigation System Diagram (Profile) M3 = Radon Mitigation System Diagram — AC Return Closet Detail M4 = Ventilation Fan Specification M5 = Access Panel Specification M6 = Deco Grill Specification (Supply Grill) M7 = Outside Air Vent Hood Specification M8 = Timer & Manometer Specification El = Electrical Specifications Contractors Air Conditioning Contractor = Radon Mitigation Services, LLC 3361 5 th Ave SW Naples, FL 34117 Gene Yacobacci CAC 1816667 STIUciE coUMy 239-340-0027 PLM REVIEW Electrical Contractor Mike Lang Electrical Cont., Inc BU)Q 5408 San Roma Circle Lake Worth, FL 33467 DATE7� ezc:—� Michael T. Lang DATr=IZAV 7 ECO000227 PUJNM 561-723-2895 DATE_,_ r=C CH DATE._7-A-j Applicable Codes FL Building Code 2014 FL Mechanical Code 2014 Electrical Code — NEC2014 Z! O/A Supply To AC Return - Deco Grill Installed In Celling UMNG Room 13' x 15' PA -no 13'x 4' Applicable Codes FL Building Code 2014 FL Mechanical Code 2014 Electrical Code — NEC2014 ELECTRICAL —INSTALL RECEPTACLE& UL LISTED TIMER / ON/ OFF SWITCH AT ACCESS PANEL LOCATION. Power From General Lighting Circuit. SEE El VrK L NEN rFresh ALir ltk, Ve lNI JEN r V t I ent THE VENTILATION FAN IS INSTAI I ED ABOVE THE DRYWALL CEILING IN THE BATHROOM A 14" X 14" ACCESS PANEL IS INSTALLED IN THE CEILING 4-Inch Thermo Fin Metal Duct Routes Above Drywall Ceiling All Wall Penetrations Are Located On Exterior Walls. No Hallway Or Breezeway Penetrations One Bedroom / One Bathroom 786 Sq. Ft. Radon Mitigation System Design Mechanical Ventilation Radon Mitigation Services, LLC Arium Pines Lake Apartments FIL State Certified Radon Mifigation Business #RB1 599 7245 Pine Lakes Blvd. 33615 1h Avenue SW Port St. Lucie, FL 34952 Naples, FL 34117 Building # 4 239-340-0027 Gene Yacobacci FL State Certified Radon Mitigation Specialist #R1 598 1A FL State Certified General Contractor #CGC1520422 FIL State Certified AC Contractor #CAC1816667 Gene Yacobacci M 1 System Failure Device U-Tube Manometer — installed In Each AC Closet. Upper Floor Unit (S) No Access Required Concrete Deck 12-Inches omm 14"x 14" 4-Inch Metal Duct Access Panel Timer — Plugs In To New Receptacle ir Handier Return Closet 1/2" Drywall Ventilation Fan Ceiling. Installed Above Drywall Ceiling Radon Mitigation System Design Radon Mitigation Services, LLC FL State Certified Radon Mitigation Business #RB1599 33615 th Avenue SW Naples, FL 34117 239-340-0027 Gene Yacobacci FL State Certified Radon Mitigation Specialist #R1 598 FL State Certified General Contractor #CGC1520422 FL State Certified AC Contractor #CAC1 816667 Outside Air Intake Vent Hood Exterior Block wall Arium Pines Lake Apartments 7245 Pine Lakes Blvd. Port St. Lucie, FIL 34952 Building # 4 M2 4-Inch Radon Duct 4-INCH DECO GRILL Fresh air Supply AIR HANDLER System Failure Device U-Tube Manometer Installed In Each AC Closet. WATER HEATER SUPPLY AIR DUCT Mechanical Closet Profile - Typical All Units Radon Mitigation Services, ILLC FL State Certified Radon Mitigation Business #RB1 599 3361 5 1h Avenue SW Naples, FL 34117 239-340-0027 Gene Yacobacci FL State Certified Radon Mitigation Specialist #R1598 FL State Certified General Contractor #CGC 1520422 FL State Certified AC Contractor #CAC1 816667 Arium Pines Lake Apartments 7245 Pine Lakes Blvd. Port St. Lucie, FL 34952 Building # 4 M3� RADON FAN SPECIFICA 'ONS RADONAWAY (SPRUCE) RV100 8.5" Designed specially for radon mitigation, RV Series Fans provide superb performance, use — little electric power, run ultra quiet and are attractive. An ideal choice for most radon mitigation systems. Model selection is dependent on building characteristics and 9 should be made by a radon professional. *Typical monthly electric cost $1.00 - $2.00 depending on model, electric rates & operating conditions. (a Maximum F Typical CFM vs Static Pressure WC" Pressure I . RV100 1 40 1 2.0" WC 11 100 1 80 55 1� 35 1 - 5 - Year Warranty. Mounts on duct 4" diameter ducts. Rugged .125" Noryl plastic housing. Electrical box for hard wire or plug in. ETL Safety Agency Listed - tested to LIL Standard 507 for indoor or outdoor use. Meets all electrical code requirements. Size: 9.5H" x 8.5" Dia. Weight- 6 lbs. Continuous Duty / Thermally protected Class B Insulation 3000 RPM Rated for Indoor or Outdoor use ICONCRETE DECK I Fan Supported Using Factory Bracket Secured To Deck Using (3) 3/8 X 1 % Tap Cons I INC ME:H: DUCT DROP CEILING SPACE 12' TO OUTSIDE WALL RVIOD FAN UNIT INS FFRES�; AIR DISCHARGE 1 114-X14'AC ESSPANEL� 1INDROPCEILING ID LL DROP CEILIN�G] Radon Mitigation Services, LLC FL State Certified Radon Mitigation Business #RB1 599 3361 5 th Avenue SW Naples, FL 34117 239-340-0027 Gene Yacobacci FL State Certified Radon Mitigation Specialist #R1598 FL State Certified General Contractor #CGC1520422 FIL State Certified AC Contractor #CAC1816667 Arium Pines Lake Apartments 7245 Pine Lakes Blvd. Port St. Lucie, FL 34952 Building # 4 M4 i W. ilint!) St. ACCE .aland, 011144135 SS j FX'800-321-9535 PH:800-321-9532 ACCESS PANELS [is 0 GOT, INURV.DaISYMM 'AL SPECIFICATION TECHNICAL SPECIFICATION: Daley Access Able Access Panels are designed to allow access to service areas. Acoess Panels can be used for access to plumbing, electrical, security systems, telephone, computer cables, and sprinideT systems. Reversible feature allows for flush mounting "surface mounting. US.PatwtFzF489Q4J8&5355325. U, PHYS)CALICHEMICAL PROPERTIES Material U.V. Stabilized ABS Color White DIRECTIONS FOR USE Surface Mount Installation: Cut appropriate size opening using frame as a template. Check for level. Apply construction adhesive to backside of frame flange. Fit frame Into opening. Press flange against wall to ensure flat Installation. After adhesive Is set, snap door Into place. Flush Mount Installation: Nail or screw frame Into place at desired location with flange flat against the stud. Check for level. Drywall or plaster to the top of the flange. Snap on door after wall covering Is complete. COMMON APPLICATIONS Oatey Access Panels provide access to service areas, while allowing an easy Installation Into wall surface. Patented clips on panel door and frame eliminate sagging or bowing of door In ceiling applications. V/ PRODUCT DESCRIPTION Actual Door Size Frame Size to Wall Opening PACK NUMBER Outer Flange I C I D I E 1 34056 14" x 140 Access Panel 1344" 13-V4" 1 17" 1 17' 1 14N 1 Data is subject to manufacturing tolerances. Radon Mitigation Services, LLC FL State Certified Radon Mitigation Business #RB1 599 3361 5th Avenue SW Naples, FL 34117 239-340-0027 Gene Yacobacci Fl- State Certified Radon Mitigation Specialist #R1598 FL State Certified General Contractor #CGC 1520422 FL State Certified AC Contractor #CAC1 816667 M5 Arium Pines Lake Apartments 7245 Pine Lakes Blvd. Port St. Lucie, FL 34952 Building # 4 Gene Yacobacci Fl- State Certified Radon Mitigation Specialist #R1598 FL State Certified General Contractor #CGC 1520422 FL State Certified AC Contractor #CAC1 816667 M5 Arium Pines Lake Apartments 7245 Pine Lakes Blvd. Port St. Lucie, FL 34952 Building # 4 A* r*4 E Tjk N PRODUCT JE SPECIFICATIONS and TECHNICAL eS Deco Grille DATA 0810 C11 D Part# Size Description A B c D 22073 3' ELA T!C ABS)GRILLE 3" 4-3/4" T 1/2ft 5/8" WHI PL 72 MITF AST E�(AOS) GRILLE 4" 5-3/4" 11/16" V 22 E78 51, WHITE PLASTJ C(ABS)GRILLE 6' 6-1/2" 5/9' 1 1-110 ,,AM E=- F11 C;AA N Maldes lvv_m-r 4521 1 9th Street Court E., Suite 104, Bradenton, FL 34203 USA Phone: 941-351-34411 Fax: 941-351-3442 wvvw.amedcanaldes.com I E-mail: info@aldes-us.com 1A9T18 PRATID L LINE 4749 deco_grille—specL0610 Gene Yacobacci FL State Certified Radon Mitigation Specialist #R1 598 FL State Certified General Contractor #CGC1520422 FIL State Certified AC Contractor #CAC1816667 M6 Radon Mitigation Services, LLC FL State Certified Radon Mitigation Business #RB1 599 33615 th Avenue SW Naples, FL 34117 239-340-0027 Ariurn Pines Lake Apartments 7245 Pine Lakes Blvd. Port St. Lucie, FL 34952 Building # 4 4521 1 9th Street Court E., Suite 104, Bradenton, FL 34203 USA Phone: 941-351-34411 Fax: 941-351-3442 wvvw.amedcanaldes.com I E-mail: info@aldes-us.com 1A9T18 PRATID L LINE 4749 deco_grille—specL0610 Gene Yacobacci FL State Certified Radon Mitigation Specialist #R1 598 FL State Certified General Contractor #CGC1520422 FIL State Certified AC Contractor #CAC1816667 M6 Radon Mitigation Services, LLC FL State Certified Radon Mitigation Business #RB1 599 33615 th Avenue SW Naples, FL 34117 239-340-0027 Ariurn Pines Lake Apartments 7245 Pine Lakes Blvd. Port St. Lucie, FL 34952 Building # 4 .91 . dh �O a ware 0 Technical Product Fresh Air Intake Vent With molded plastic grid HSM4W,H5M4B 4" (CD Plastic collar (SVMAW4 only) Model No. I A B C 11SM4W 6' 5%' 4' HSM4B 6' VA" 4" SVMAW4 6' 5W 4' 51891 I A I Made[ No. Description Color SVMAW4 Hood/pipe/coltar assem. White for all plastic molded fresh air intake vents Hood Calcium filled Polypropylene • Melting point: 325- F+ • UV Inhibitor added Pipe Aluminum Collar - Styrene SVMAW4 9 Free Air 4" dia. = lo square inches e Protective Geld Size 4"dia. = protective grid 7 (pipe SVMAW4 oniV) 1P. � Radon Mitigation Services, LLC FL State Certified Radon Mitigation Business #RB1 599 3361 5th Avenue SW Naples, FL 34117 239-340-0027 Gene Yacobacci FL State Certified Radon Mitigation Specialist #R1 598 FL State Certified General Contractor #CGC1520422 FL State Certified AC Contractor #CACI 816667 • stationary molded plastic louvers • quick, easy installation • plastic furnace fresh air intakes come with a molded screen to help prevent birds and rodents from entering • durable weather resistant Molded for easy connection of pipe Side View B sq. Rear View Arium Pines Lake Apartments 7245 Pine Lakes Blvd. Port St. Lucie, FL 34952 Building # 4 M7 CHICAGO"' USUB E218111 Timer Instructions: Warning: 1. The Timer is designed for indoor use only. 2. Keep this product out of the hands of children. 3. Only plug the timer into a 125VAC electrical outlet. 4. Maximum Watts: 2,000 Watts (Do not exceed). 5. Keep Timer dry at all times. Do not plug in the Timer if hands or feet are wet. 6. Plug the one or two appliances into the Timer. Set the ON/OFF switch to ON. Plug the Timer into a 125VAC electrical outlet, and the Timer set-up is complete. Setting the ON/OFF function: Note the black time indicators behind the dial. Each time indicator represents 15 minutes. When setting the ON/OFF function, you have to push the appropriate time indicators down, away from the dial. Example: Setting the light to turn on at 8 P.M. and turn off at 6 A.M. All time indicators between 20 (8 P.M.) and 6 (6 A.M.) must be pushed down, away from the dial. When setting the time indicators. Note the RED ON/OFF switch on the side of the Timer. Pushing this switch upward will activate the timer. Push this switch downward to deactivate the Timer. Easy Read Dynameter Vacuum Gauge 1. Reads 0 — 4" W.C. 2. Non -toxic Fluid 3. Adjustable zero 4. Vinyl tube connects 5. Mounts On Wall of AC closet or other visible location Radon Mitigation Services, LLC FL State Certified Radon Mitigation Business #RB1 599 3361 5 th Avenue SW Naples, FL 34117 239-340-0027 Gene Yacobacci FL State Certified Radon Mitigation Specialist #R1 598 FL State Certified General Contractor #CGC1520422 FL State Certified AC Contractor #CAC1 816667 .4 . Fan ON Arium Pines Lake Apartments 7245 Pine Lakes Blvd. Port St. Lucie, FL 34952 Building # 4 M New Receptacle Installed For Radon Fan Unit. Includes UL Listed Timer RV100 Fan Installed Above Drywall Ceiling I Behind Access Panel By AC Contractor Fan = 40W 0.6A 14 2 OR 12/ 2 ROMEX TO PANEL BOX OR GENERAL Circuit Shall Have Adequate Capacity LIGHTING CIRCUIT To Support Additional Load 20A UL Listed Timer ) 2KAS LISTED ELECTRICAL PLANS 1 Receptacle — Ground Floor Unit PANEL BOX OR GENERAL LIGHTING CIRCUIT Mike Lang Electrical Cont. Arium Pines Lake Apartments 5408 San Roma Circle 7245 Pine Lakes Blvd. Lake Worth, FL 33467 Port St. Lucie, FL 34952 561-723-2895 Building # 4 Michael T. Lang Fl- State Cerlitied Electrical Contractor # ECO000227 Michael T. Lang El