Loading...
HomeMy WebLinkAboutDESIGN AND SPECIFICATIONRADON MITIGATION SYSTEM DESIGN AND SPECIFICATIONS Owner: BR Carroll St. Lucie, LLC 7700 Pine Lakes Blvd Port St. Lucie, FL 34952 SCANNED BY PROPERTY NAME = ARIUM PINE LAKES APARTMENTS St. Lucie County Job Address = 7265 Pine Lakes Blvd, Port St. Lucie, FIL 34952 (Building # 4) Contents MI = Radon Mitigation System Diagram (2 Bed / 2 Bath) M2 = Radon Mitigation System Diagram (Profile) M3 = Radon Mitigation System Diagram — AC Return Closet Detail M4 = Ventilation Fan Specification M5 = Access Panel Specification M6 = Deco Grill Specification (Supply Grill) M7 = Outside Air Vent Hood Specification M8 = Timer & Manometer Specification El = Electrical Specifications Contractors Air Conditioning Contractor = Radon Mitigation Services, LLC 3361 5" Ave SW Naples, FL 34117 Gene Yacobacci CAC1816667 239-340-0027 STIUCIE COUNTY PLAN REvIEW BLDG DATE ELEC- DAT;*�--AE/ 7 PLUMB: DATE. MEC:j .. .7 DATE. Electrical Contractor = Mike Lang Electrical Cont., Inc 5408 San Roma Circle Lake Worth, FL 33467 M ECO000227 -'OWY ichael T. Lang ALE LO;- 561-723-2895 Applicable Codes FL Building Code 2014 FL Mechanical Code 2014 Electrical Code — NEC2014 O/A Supply To AC Return - Deco Grill Installed Jn Ceiling Urmc.). Room 1T x 160 P10.1 [a, 130'x 4' 19 4-Inch Thermo Fin Metal Duct Routes Above Drywall Ceiling THE VENTILATION FAN IS INSTALLED ABOVE THE DRYWALL CEILING IN THE BEDROOM CLOSET A 14"X 14"ACCESS PANEL IS INSTALLED IN THE CEILING I'l P X\1 (yar ELECTRICAL— INSTALL RECEPTACLE & UL LISTED TIMER / DISCONNECT AT ACCESS PANEL LOCATION. Power From General Lighting Circuit. SEE El I All Wall Penetrations Are Located Fresh Air Intake On Exterior Walls. No Hallway Or Vent I Breezeway Penetrations Two Bedroom / Two Bathroom 1,039 Sq. Ft. Radon Mitigation System Design Mechanical Ventilation Radon Mitigation Services, LLC Ariurn Pines Lake Apartments FL State Certified Radon Mitigation Business #RB1 599 7265 Pine Lakes Blvd. 3361 5th Avenue SIN Port St. Lucie, FIL 34952 Naples, Fl- 34117 Building # 4 239-340-0027 Gene Yacobacci FL State Certified Radon Mitigation Specialist #R1 598 Fl- State Certified General Contractor #CGC1520422 A FL State Certified AC Contractor #CAC1 816667 Gene Yacobacci M 1 System Failure Device U-Tube Manometer — Installed In Each AC Closet. 12-Inches Air Handler Return Closet amm Upper Floor Unit (S) No Access Required Concrete Deck 14"x 14' 4-Inch Metal Duct Access Panel Til _ Plugs In To New Receptacle W Drywall Ventilation Fan Ceiling. Installed Above Drywall Ceiling Radon Mitigation System Design Outside Air Intake Vent Hood Exterior Block Wall Radon Mitigation Services, ILLC Arium Pines Lake Apartments FL State Certified Radon Mitigation Business #RB1 599 7265 Pine Lakes Blvd. 3361 5th Avenue SW Port St. Lucie, Fl- 34952 Naples, Fl- 34117 Building # 4 239-340-0027 Gene Yacobacci Fl- State Certified Radon Mitigation Specialist #R1 598 FL State Certified General Contractor #CGC 1520422 FIL State Certified AC Contractor #CACI 816667 M2 4-Inch Radon Duct 51 4-INCH DECO GRILL Fresh air Supply AIR HANDLER System Failure Device U-Tube Manometer Installed In Each AC Closet. WATER HEATER SUPPLY AIR DUCT Mechanical Closet Profile - Typical All Units Radon Mitigation Services, LLC FL State Certified Radon Mitigation Business #RB1 599 33615 th Avenue SW Naples, FL 34117 239-340-0027 Gene Yacobacci FL State Certified Radon Mitigation Specialist #R1 598 FL State Certified General Contractor #CGC1520422 FL State Certified AC Contractor #CAC1 816667 Arium Pines Lake Apartments 7265 Pine Lakes Blvd. Port St. Lucie, FL 34952 Building # 4 M3� 7 -�PON FAN SPECIFICATIONI'� RADONAW" (SPRUCE) RV100 8.5" 0 Designed specially for radon mitigation, RV Series Fans provide superb performance, use little electric power, run ultra quiet and are attractive. An ideal choice for most radon mitigation systems. Model selection is 9.5" dependent on building characteristics and should be made by a radon professional. *Typical monthly electric cost $1.00 - $2.00 depending on model, electric rates & operating conditions. Maximum I[— Typical CIFM vs Static Pressure Pressure F71-070 5 - Year Wa rra nty. Mounts on duct 4" diameter ducts. Rugged .125" Noryl plastic housing. Electrical box for hard wire or plug in. ETL Safety Agency Listed - tested to UL Standard 507 for indoor or outdoor use. Meets all electrical code requirements. Size: 9.5H" x 8.5" Dia. Weight- 6 lbs. Continuous Duty / Thermally protected Class B Insulation 3000 RPM Rated for Indoor or Outdoor use ICONCRETE DECK I Fan Supported Using Factory Bracket Secured To Deck Using (3) 3/8 X 1 % Tap Cons I A W A A 4 V 4-INCH DUCT 4- 4- DROP CEILING SPACE 1T TOOLITSIDEWALL RV100 FAN UNIT INSTALLED FFRE7AJR DISCHARGE I 114PX14-AC ESSPANELI 1INDROPCEILING ID LL DROP CEILNG Radon Mitigation Services, LLC FL State Certified Radon Mitigation Business #RB1599 33615 th Avenue SW Naples, FIL 34117 239-340-0027 Gene Yacobacci FL State Certified Radon Mitigation Specialist #R1 598 FL State Certified General Contractor #CGC1 520422 FL State Certified AC Contractor #CAC1 816667 Arium Pines Lake Apartments 7265 Pine Lakes Blvd. Port St. Lucie, FL 34952 Building # 4 M41 0 4700 IN ' is, Clawaland, viv�,35 ACCESS ABLEO PH:800-321-9532 ACCESS PANELS AISQj9call, FXlNO-321-9W5 I www.caley.com �Iwv .SPECIFICATION TECHNICAL SPECIFICATION: Oatey Access Able Access Panels are designed to allow access to service areas. Access Panels can be used for acw= to plumbing, electrical, security systems, telephone, computer cables, and sprinkler systems. Reversible feature allows for flush mounting or surface mounting. VS.Pjtent9,f4M,4j8&5,355,526. I iz lZ 4 PROPERTIES S Material UN. Stabilized ABS Color White DJRECnONS FOR USE Surface Mount Installation- Cutappropriate size opening using frame as a template Check for level. Apply construction adhesive to backside of frame flange. Fit frame into opening. Press flange against wall to ensure flat Installation. After adhesive Is set, snap door Into place. Flush Mount Installation: Nail or screw frame Into place at desired location with flange flat against the stud. Check for level. Drywall or plaster to the top of the flange. Snap on door after wall covering Is complete. COMMON APPI-ICATXONS Oatey Access Panels provide access to service areas, while allowing an easy Installation Into wall surface. Patented clips on panel door and frame eliminate sagging or bowing of door in ceffling applications. PRODUCT I DESCRIPTION ActualDoorSize FrameSIzeto Wall Openln -nt�NUMBER Outer Flange C 1 0 E I F4!n 34056 1 14"x 14" Access Panel 13-3A" 1344" 17- 1 17" 1 140 14' 16 1 Data is subject to manufacturing tolerances. Radon Mitigation Services, LLC FL State Certified Radon Mitigation Business #RB1 599 3361 5 th Avenue SW Naples, FIL 34117 239-340-0027 Gene Yacobacci FL State Certified Radon Mitigation Specialist #R1598 FL State Certified General Contractor #CGC1520422 FL State Certified AC Contractor #CAC1 816667 M5 Arium Pines Lake Apartments 7265 Pine Lakes Blvd. Port St. Lucie, FL 34952 Building # 4 Naples, FIL 34117 239-340-0027 Gene Yacobacci FL State Certified Radon Mitigation Specialist #R1598 FL State Certified General Contractor #CGC1520422 FL State Certified AC Contractor #CAC1 816667 M5 Arium Pines Lake Apartments 7265 Pine Lakes Blvd. Port St. Lucie, FL 34952 Building # 4 I- I PRODUCT ^MMF11C;A,, SPECIFICATIONS and TECHNICAL Maides Deco Grille DATA 0810 ALM E=- F1 I C;,A N Maides Part# Size Description A 8 C D 22 72 3j 1 SITE PLAStICCABS).GRILLE 2 4-3/4" 1/7' 5/8" a 22079 ITE PLASTIC (ABS) GRILLE 4:: 5-3/4's 11/1611 V 22078 5" WHITE PLASTIC (ABS) GRILLE 5' 6-1/2" 518" 1 1-11W' 4521 1 9th Street Court E., Suite 104, Bradenton, FL 34203 USA Phone: 941-351-34411 Fax: 941-351-3442 www.ameficanaldes.com I E-mail: info@aldes-us.com Radon Mitigation Services, LLC FL State Certified Radon Mitigation Business #RB1 599 33615 th Avenue SW Naples, FL 34117 239-340-0027 Gene Yacobacci FL State Certified Radon Mitigation Specialist #R1 598 FL State Certified General Contractor #CGC1520422 FL State Certified AC Contractor #CAC1 816667 M6 Ariurn Pines Lake Apartments 7265 Pine Lakes Blvd. Port St. Lucie, FL 34952 Building # 4 Part# Size Description A 8 C D 22 72 3j 1 SITE PLAStICCABS).GRILLE 2 4-3/4" 1/7' 5/8" a 22079 ITE PLASTIC (ABS) GRILLE 4:: 5-3/4's 11/1611 V 22078 5" WHITE PLASTIC (ABS) GRILLE 5' 6-1/2" 518" 1 1-11W' 4521 1 9th Street Court E., Suite 104, Bradenton, FL 34203 USA Phone: 941-351-34411 Fax: 941-351-3442 www.ameficanaldes.com I E-mail: info@aldes-us.com Radon Mitigation Services, LLC FL State Certified Radon Mitigation Business #RB1 599 33615 th Avenue SW Naples, FL 34117 239-340-0027 Gene Yacobacci FL State Certified Radon Mitigation Specialist #R1 598 FL State Certified General Contractor #CGC1520422 FL State Certified AC Contractor #CAC1 816667 M6 Ariurn Pines Lake Apartments 7265 Pine Lakes Blvd. Port St. Lucie, FL 34952 Building # 4 A%01,ec wt .5a Technicat Product Speciftations Fre h Air Intake Vent with molded plastic grid Model No. Description Color SVMAW4 Hood/pipe/collar assem. White HSM4W,HSM4B 4 (CD Plastic collar (SVMAW4 OflIY) Model No. A B C HS&14W 6" 5/2' 4' SV W4 6; ;4- 511F. I A j 5VMAW4 SVMAW4 only) Radon Mitigation Services, LLC FL State Certified Radon Mitigation Business #RB1 599 33615 th Avenue SW Naples, FL 34117 239-340-0027 Gene Yacobacci FL State Certified Radon Mitigation Specialist #R1598 FL State Certified General Contractor #CGC1520422 FL State Certified AC Contractor #CAC1 816667 vents Hood Calcium filled Polypropylene Melting point:2250 F+ C UV Inhibitor a ded Pipe Aluminum Collar - Styrene • Free Air 4" dia. = io square inches • Protective Grid Size 4"dia. = protective grid • stationary molded plastic louvers • quick, easy installation • plastic furnace fresh air intakes come with a molded screen to help prevent birds and rodents from entering • durable weather resistant Molded for easy connection of pipe Side View B sq. Rear View Arium Pines Lake Apartments 7265 Pine Lakes Blvd. Port St. Lucie, FL 34952 Building # 4 M7 CHICAGO L 17 8. ED E218111 Timer Instructions: Warning: 1. The Timer is designed for indoor use only. 2. Keep this product out of the hands of children. 3. Onl� plug the timer into a 125VAC electrical outlet. 4. Maximum Watts: 2,000 Watts (Do not exceed). 5. Keep Timer dry at all times. Do not plug in the Timer if hands or feet are wet. 6. Plug the one or two appliances into the Timer. Set the ON/OFF switch to ON. Plug the Timer into a 125VAC electrical outlet, and the Timer set-up is complete. Setting the ON/OFF function: Note the black time indicators behind the dial. Each time indicator represents 15 minutes. When setting the ON/OFF function, you have to push the appropriate time indicators down, away from the dial. Example: Setting the light to turn on at 8 P.M. and turn off at 6 A.M. All time indicators between 20 (8 P.M.) and 6 (6 A.M.) must be pushed down, away from the dial. When setting the time indicators. Note the RED ON/OFF switch on the side of the Timer. Pushing this switch upward will activate the timer. Push this switch downward to deactivate the Timer. Easy Read Dynameter Vacuum Gauge 1. Reads 0 — 4" W.C. 2. Non -toxic Fluid 3. Adjustable zero 4. Vinyl tube connects 5. Mounts On Wall of AC closet or other visible location Radon Mitigation Services, LLC FL State Certified Radon Mitigation Business #RB1599 33615 th Avenue SW Naples, FL 34117 239-340-0027 Gene Yacobacci FL State Certified Radon Mitigation SpecialisUR-1598 FL State Certified General Contractor #CGC1520422 FL State Certified AC Contractor #CAC1 816667 Fan ON Arium Pines Lake Apartments 7265 Pine Lakes Blvd. Port St. Lucie, FL 34952 Building # 4 M New Receptacle Installed For Radon Fan Unit. Includes UL Listed Timer RV100 Fan Installed Above Drywall Ceiling Behind Access Panel By AC Contractor Fan = 40W 0.6A 14 / 2 OR 1212 ROMEX TO PANEL BOX OR GENERAL Circuit Shall Have Adequate Capacity LIGHTING CIRCUIT To Support Additional Load 20A UL Listed Timer CHICAGO 1,2KAS: L LISTED E-21 8 111 ELECTRICAL PLANS 1 Receptacle — Ground Floor Unit PANEL BOX OR GENERAL LIGHTING CIRCUIT Mike Lang Electrical Cont. Arium Pines Lake Apartments 5408 San Roma Circle 7265 Pine Lakes Blvd. Lake Worth, FL 33467 Port St. Lucie, FL 34952 561-723-2895 Building # 4 Michael T. Lang FL State Certified Electrical Contractor # ECO000227 Michael T. Lang El