Loading...
HomeMy WebLinkAboutDESIGN AND SPECIFICATIONRADON MITIGATION SYSTEM DESIGN AND SPECIFICATIONS Owner: BIR Carroll St. Lucie, LLC SCANNED 7700 Pine Lakes Blvd BY Port St. Lucie, FIL 34952 St. Lucie County PROPERTY NAME = ARIUM PINE LAKES APARTMENTS Job Address = 7749 Pine Lakes Blvd, Port St. Lucie, FL 34962 (Building # 1) Contents &'% j7t� MI = Radon Mitigation System Diagram (1 Bed / I Bath)FILLuupy M2 = Radon Mitigation System Diagram (Profile) M3 = Radon Mitigation System Diagram — AC Return Closet Detail M4 = Ventilation Fan Specification M5 = Access Panel Specification M6 = Deco Grill Specification (Supply Grill) M7 = Outside Air Vent Hood Specification M8 = Timer & Manometer Specification El = Electrical Specifications Contractors Air Conditioning Contractor = Radon Mitigation Services, LLC 3361 5�h Ave SW Naples, FIL 34117 Gene Yacobacci CAC1816667 239-340-0027 Electrical Contractor = Mike Lang Electrical Cont., Inc 5408 San Roma Circle Lake Worth, FL 33467 Michael T. Lang ECO000227 561-723-2895 Applicable Codes FIL Building Code 2014 FL Mechanical Code 2014 Electrical Code — NEC2014 MUCIE 00UN1Y PLAN REMEW BLDG: DAM ELEC: DATE-W-7 PLUMB;__ DATE�-. ELECTRICAL —INSTALL RECEPTACLE& UL LISTED TIMER / ON/ OFF SWITCH AT ACCESS PANEL LOCATION. MUM Power From General Lighting Circuit. SEE El O/A Supply To AC Return - u- Deco Grill Installed In Ceilinq -.if 7 7AWK-1 Fresh Air Intake Vent THE VENTILATION FAN IS INSTALLED ABOVE THE DRYWALL CEILING IN THE BATHROOM A 14"X 14" ACCESS PANEL IS INSTALLED IN THE CEILING 14' X -1 V 3 ln�h �hen`nouFin c T MI , et'l 0'c Me a 0 't R, te, UMNG Room Above Drywall v C 11 g 13 r x 1 S' Ceiling All Wall Penetrations Are Located RA'no On Exterior Walls. No Hallway Or 110 Breezeway Penetrations 13' x 4' Applicable Codes FL Building Code 2014 FL Mechanical Code 2014 Electrical Code — NEC2014 One Bedroom / One Bathroom 786 Sq. Ft Radon Mitigation System Design Mechanical Ventilation Radon Mitigation Services, LLC FL State Certified Radon Mitigation Business #RB1599 3361 5 th Avenue SW Naples, I'L 34117 239-340-0027 Gene Yacobacci FL State Certified Radon Mifigation Specialist #R1 598 FL State Certified General Contractor #CGC1520422 FL State Certified AC Contractor #CAC1816667 Gene Yacobacci Arium Pines Lake Apartments 7749 Pine Lakes Blvd. Port St. Lucie, FL 34952 Building # 1 LE System Failure Device U-Tube Manometer, Installed In Each AC closet. Upper Floor Unit (S) No Access Required Radon Mitigation System Design Radon Mitigation Services, LLC FL State Certified Radon Mitigation Business #RB1 599 3361 E�h Avenue SW Naples, FL 34117 239-340-0027 Gene Yacobacci FL State Certified Radon Mitigation Specialist #R1598 FL State Certified General Contractor #CGC1520422 FL State Certified AC Contractor #CAC1 816667 Outside Air Intake Vent Hood Exterior Block wall Arium Pines Lake Apartments 7-749 Pine Lakes Blvd. Port St. Lucie, FL 34952 Building # 1 M2 4-Inch Radon Duct 4-INCH DECO GRILL Fresh air Supply UILM". NOW System Failure Device U-Tube Manometer Installed In Each AC Closet. WATER HEATER SUPPLY AIR DUCT Mechanical Closet Profile - Typical All Units Radon Mitigation Services, LLC Fl- State Certified Radon Mitigation Business #RB1 599 3361 5th Avenue SW Naples, Fl- 34117 239-340-0027 Gene Yacobacci FL State Certified Radon Mitigation Specialist #R1 598 FL State Certified General Contractor #CGC1520422 FL State Certified AC Contractor #CAC1 816667 Arium Pines Lake Apartments 7749 Pine Lakes Blvd. Port St. Lucie, FL 34952 Building # 1 M3 -DON FAN SPECIFICATION,�-_, RADONAW" (SPRUCE) RV100 Designed specially for radon mitigation, RV Series Fans provide superb performance, use little electric power, run ultra quiet and are attractive. An ideal choice for most radon mitigation systems. Model selection is dependent on building characteristics and should be made by a radon professional. 9.5" *Typical monthly electric cost $1.00 - $2.00 depending on model, electric rates & operating conditions. (a Maximum [_ Ty ical CFM vs Static Pressure WC"--] Pressure F 10-0 F-5-5-1 5 - Year Warranty. Mounts on duct 4" diameter ducts. Rugged .125" Noryl plastic housing. Electrical box for hard wire or plug in. ETL Safety Agency Listed - tested to UL Standard 507 for indoor or outdoor use. Meets all electrical code requirements. Size: 9.5H" x 8.5" Dia. Weight 6 lbs. Continuous Duty / Thermally protected Class B Insulation 3000 RPM Rated for Indoor or Outdoor use Fan Supported Using Factory Bracket Secured To Deck Using (3) 3/8 X 1 % Tap Cons A 41 V 4-INCH DUCT J� DROP CEILING SPACE 12' JOOUTSIDEWALL RV100 FAN UNIT INSTALLED �TAJ R DISCHARGE 1 114'X14' CESS IN DROP CEILING L DROP CEILING39 FFR E_; PANEL] I I Radon Mitigation Services, LLC FL State Certified Radon Mitigation Business #RB1599 3361 5th Avenue SW Naples, FL 34117 239-340-0027 Gene Yacobacci FL State Certified Radon Mitigation Specialist #R1 598 FL State Certified General Contractor #CGC 1520422 FL State Certified AC Contractor #CAC1 816667 Arium Pines Lake Apartments 7749 Pine Lakes Blvd. Port St. Lucie, FL 34952 Building # I M41 QD 470D W. 111' *90 Cleveland, .—.—"�35 ACCESS ABLE" PR:800-321-M ACCESS PANELS FX*SDD-321-9535 www.oatey.com SPECIFICATION TECHNICAL SPECIFICATION: Oatey Access Able Access Panels are designed ba, allow access to serrvice areas. Access Panels can be used for acce to plumbing, electrical, security systems, telephone, computer cables, and sprinkler systems. Reversible feature allows for flush mounting or surface mounting. US.Pjta71s#4,M,418&5355526. 1 rZ Z PHYSICALICHEMICAL PROPER71ES Material U.V. Stabilized ABS Color White DIRECTIONS FOR USE Surface Mount Installation: Cut appropriate size opening using frame as a template. Check for level. Apply construction adhesive to backside of frame flange. Fit frame into opening. Press flange against wall to ensure flat Installation. After adhesive Is set, snap door Into place. Flush Mount Installation: Nall or screw frame Into place at desired location with flange flat against the stud. Check for level. Drywall or plaster to the top of the flange. Snap on door after wall covering Is complete. COMMON APPLICATIONS Oatey Access Panels provide access to service areas, while allowing an easy Installation Into wall surface. Patented clips on panel door and frame eliminate sagging or bowing of door In cidling applications. PRODUCT I DESCRIPTION Actual Door Size Frame Size to Wall Opening PACK NUMBER I I Outer Flange A 1 8 1 C I D I E I IF 1 34056 1 14" x 140 Amass Panel 113-114' 13-V40 1 170 1 17' 1 14N 1 1 1 1 1 1 1 1 1 Data is subjed to manufarchuing toleranan. Radon Mitigation Services, LLC FIL State Certified Radon Mitigation Business #RB1599 33615 th Avenue SW Naples, FL 34117 239-340-0027 Gene Yacobacci FL State Certified Radon Mitigation Specialist #R1 598 FL State Certified General Contractor #CGC1520422 FL State Certified AC Contractor #CAC1816667 M5 Arium Pines Lake Apartments 7749 Pine Lakes Blvd. Part St. Lucie, FL 34952 Building # 1 Gene Yacobacci FL State Certified Radon Mitigation Specialist #R1 598 FL State Certified General Contractor #CGC1520422 FL State Certified AC Contractor #CAC1816667 M5 Arium Pines Lake Apartments 7749 Pine Lakes Blvd. Part St. Lucie, FL 34952 Building # 1 MaideS Deco Grille PRODUCT SPECIFICATIONS andTECHNICAL DATA 0810 E C Part4 Size Dewription A B C D 22073 9' WHITE PLASTIC (ABS) GRILLE 3" 4-3/4" 1/7'.. "V 33 a72 N' WHITE PLASTIC (ABS) GRILLE 4' 5-3/4" 11/15 22078 WHITE PLASTIC (ABS) GRILLE 5- 5/8" 1:1::�1/4 Ma Ides %-F-W-M-�Wjc 4521 1 9th Street Court E., Suite 1 G4, Bradenton, FL 34203 USA Phone: 941-351-34411 Fax: 941-351-3442 wvvw-americanaides.com I E-mail: info@aldes-us.com 1 &9 0TIC UTIC INE 7749 deco_grille—spec.0810 Gene Yacobacci FL State Certified Radon Mitigation Specialist #R1598 FL State Certified General Contractor #CGC 1520422 FL State Certified AC Contractor #CAC1816667 L Radon Mitigation Services, LLC FL State Certified Radon Mitigation Business #RB1 599 3361 5 th Avenue SW Naples, FL 34117 239-340-0027 Ariurn Pines Lake Apartments 7749 Pine Lakes Blvd. Port St. Lucie, FIL 34952 Building # 1 1 &9 0TIC UTIC INE 7749 deco_grille—spec.0810 Gene Yacobacci FL State Certified Radon Mitigation Specialist #R1598 FL State Certified General Contractor #CGC 1520422 FL State Certified AC Contractor #CAC1816667 L Radon Mitigation Services, LLC FL State Certified Radon Mitigation Business #RB1 599 3361 5 th Avenue SW Naples, FL 34117 239-340-0027 Ariurn Pines Lake Apartments 7749 Pine Lakes Blvd. Port St. Lucie, FIL 34952 Building # 1 ,xidlectimd"- ���are Technical Product Specifications Fresh Air Intake Vent with molded plastic grid HSM4W,HSM4B (C: Plastic collar (SVMAW4 only) Model No. A B C HSM4W 6' OY 4" HSM4B 6' 1 VI.- 1 4-1 - -- �VMAW4 —T� 6 5V 4' 511r, I A I 5VMAW4 VMAW4 only) �—�(Plp"s 08 Radon Mitigation Services, LLC FL State Certified Radon Mitigation Business #RBI 599 3361 5lh Avenue SW Naples, FL 34117 239-340-0027 Gene Yacobacci FL State Certified Radon Mitigation Specialist #R 1598 FL State Certified General Contractor #CGC1520422 FL State Certified AC Contractor #CAC1 816667 Model No. Description Color SVMAW4 Hood/pipe/collarassem. White vents Hood Calcium filled Polypropylene Melting point: 3250 F+ UV Inhibitor added Pipe Aluminum Collar - Styrene • Free Air 4" dia. = lo square inches • Protective Grid Size 4"dia. = protective grid • stationary molded plastic louvers • quick, easy Installation • plastic furnace fresh air intakes come with a molded screen to help prevent birds and rodents from entering • durable weather resistant Molded for easy connection of pipe Side View B sq. Rear View Arium Pines Lake Apartments 7749 Pine Lakes Blvd. Port St. Lucie, FL 34952 Building # I M7 CH -,2XA8. E-218111- Timer Instructions: Warning: 1. The Timer is designed for indoor use only. 2. Keep this product out of the hands of children. 3. Only plug the timer into a 125VAC electrical outlet. 4. Maximum Watts: 2,000 Watts (Do not exceed). 5. Keep Timer dry at all times. Do not plug in the Timer if hands or feet are wet. 6. Plug the one or two appliances into the Timer. Set the ON/OFF switch to ON. Plug the Timer into a 125VAC electrical outlet, and the Timer set-up is complete. Setting the ON/OFF function: Note the black time indicators behind the dial. Each time indicator represents 15 minutes. When setting the ON/OFF function, you have to push the appropriate time indicators down, away from the dial. Example: Setting the light to turn on at 8 P.M. and turn off at 6 A.M. All time indicators between 20 (8 P.M.) and 6 (6 A.M.) must be pushed down, away from the dial. When setting the time indicators. Note the RED ON/OFT switch on the side of the Timer. Pushing this switch upward will activate the timer. Push this switch downward to deactivate the Timer. S Easy Read Dynameter Vacuum Gauge 1. Reads 0 — 4" W.C. 2. Non -toxic Fluid 3. Adjustable zero 4. Vinyl tube connects 5. Mounts On Wall of AC closet or other visible location Radon Mitigation Services, LLC FL State Certified Radon Mitigation Business #RB1 599 3361 5th Avenue SW Naples, FL 34117 239-340-0027 Gene Yacobacci FL State Certified Radon Mitigation Specialist #R1 598 FL State Certified General Contractor #CGC1520422 FL State Certified AC Contractor #CAC1 816667 Fan ON Arium Pines Lake Apartments 7749 Pine Lakes Blvd. Port St. Lucie, FL 34952 Building # 1 M rk- New Receptacle Installed For Radon Fan Unit. Includes UL Listed Timer RV100 Fan Installed Above Drywall Ceiling Behind Access Panel By AC Contractor Fan = 40W 0.6A 14 / 2 OR 12/ 2 ROMEX TO PANEL BOX OR GENERAL Circuit Shall Have Adequate Capacity LIGHTING CIRCUIT To Support Additional Load 20A UL Listed Timer ELECTRICAL PLANS 1 Receptacle — Ground Floor Unit PANEL BOX OR GENERAL LIGHTING CIRCUIT Mike Lang Electrical Cont. Arium Pines Lake Apartments 5408 San Roma Circle 7749 Pine Lakes Blvd. Lake Worth, FL 33467 Port St. Lucie, FL 34952 561-723-2895 Building # 1 Michael T. Lang FL State Certified Electrical Contractor # ECO000227 Michael T. Lang El