Loading...
HomeMy WebLinkAboutDESIGN AND SPECIFICATIONRADON MITIGATION SYSTEM DESIGN AND SPECIFICATIONS Owner: BR Carroll St. Lucie, LLC 7700 Pine Lakes Blvd Port St. Lucie, FL 34952 SCANNED BY St. Lucie County UOVYPROPERTY NAME = ARIUM PINE LAKES APARTmEFTILE "ft Job Address = 7769 Pine Lakes Blvd, Port St. Lucie, FL 34952 (Building # 1) Contents M1 = Radon Mitigation System Diagram (2 Bed / 2 Bath) M2 = Radon Mitigation System Diagram (Profile) M3 = Radon Mitigation System Diagram — AC Return Closet Detail M4 = Ventilation Fan Specification M5 = Access Panel Specification M6 = Deco Grill Specification (Supply Grill) M7 = Outside Air Vent Hood Specification M8 = Timer & Manometer Specification Ell = Electrical Specifications Contractors Air Conditioning Contractor = Radon Mitigation Services, LLC 3361 5�h Ave SW Naples, FL 34117 Gene Yacobacci CAC1816667 239-340-0027 Electrical Contractor = Mike Lang Electrical Cont., Inc 5408 San Roma Circle Lake Worth, FL 33467 Michael T. Lang ECO000227 561-723-2895 Applicable Codes FL Building Code 2014 FL Mechanical Code 2014 Electrical Code — NEC2014 ST.ILUCIE COUNTY PLAN REVIEW BUXI: DATE�-- ELECI aze nAm&ALL? PLUM- nA,TEL----...... MECW, 0,11K DATMLQ--;--L7 CIA Supply To AC Return - Deco Grill Installed In Ceiling UANG, FRY00114-11 1 3r X 16v PAHO 13' x 4 D 4-Inch Thermo Fin Metal Duct Routes Above Drywall Ceiling Il F. X\ I or 4 " ELECTRICAL— INSTALL RECEPTACLE & UL LISTED TIMER / DISCONNECT AT ACCESS PANEL LOCATION. Power From General Lighting Circuit. SEE El R �M THE VENTILATION FAN IS INSTALLED ABOVE THE DRYWALL CEILING IN THE BEDROOM CLOSET A 14" X 14" ACCESS PANEL IS INSTALLED IN THE CEILING I All Wall Penetrations Are Located Fresh Air Intake On Exterior Walls. No Hallway Or vent Breezeway Penetrations Two Bedroom / Two Bathroom 1,039 Sq. Ft. Radon Mitigation System Design Mechanical Ventilation Radon Mitigation Services, LLC FL State Certified Radon Mitigation Business #RB1 599 3361 5'nAvenue SW Naples, FL 34117 239-340-0027 Gene Yacobacci FL State Certified Radon Mitigation Specialist #R1 598 FIL State Certified General Contractor #CGC 1520422 FL State Certified AC Contractor #CAC1 816667 Arium Pines Lake Apartments 7769 Pine Lakes Blvd. Port St. Lucie, FL 34952 Building # 1 M1 System Failure Device U-Tube Manometer - Installed In Each AC Closet. Upper Floor Unit (S) No Access Required Radon Mitigation System Design Radon Mitigation Services, LLC FL State Certified Radon Mitigation Business #RB1 599 3361 5th Avenue SW Naples, FL 34117 239-340-0027 Gene Yacobacci FL State Certified Radon Mitigation Specialist #R1598 FL State Certified General Contractor #CGC1520422 FL State Certified AC Contractor #CAC1 816667 Outside Air Intake Vent Hood Exterior Block Wall Arium Pines Lake Apartments 7769 Pine Lakes Blvd. Port St. Lucie, FL 34952 Building # 1 M2 4-inch Radon Duct 4-INCH DECO GRILL Fresh air Supply AIR HANDLER System Failure Device U-Tube Manometer Installed In Each AC Closet. WATER HEATER SUPPLY AIR DUCT Mechanical Closet Profile - Typical All Units Radon Mitigation Services, LLC: FL State Certified Radon Mitigation Business #RB1 599 33615 th Avenue SW Naples, FL 34117 239-340-0027 Gene Yacobacci FL State Certified Radon Mitigation Specialist #R1 598 FL State Certified General Contractor #CGC1520422 FL State Certified AC Contractor #CAC1 816667 Arium Pines Lake Apartments 7769 Pine Lakes Blvd. Port St. Lucie, FL 34952 Building # 1 M31 F-�-)ON FAN SPEC1F1CAT10Nf"---',, RADONAWAY (SPRUCE) RV100 8.5" Designed specially for radon mitigation, RV Series Fans provide superb performance, use little electric power, run ultra quiet and are attractive. An ideal choice for most radon mitigation systems. Model selection is dependent on building characteristics and 9.5" should be made by a radon professional. *Typical monthly electric cost $1.00 - $2.00 depending on model, electric rates & operating conditions. (a Maximum Typical CFM vs Static Pressure W&7 Pressure 1 2.0" WC 1 55 5 - Year Warranty. Mounts on duct 4" diameter ducts. Rugged .125" Noryl plastic housing. Electrical box for hard wire or plug in. ETL Safety Agency Listed - tested to UL Standard 507 for indoor or outdoor use. Meets all electrical code requirements. Size: 9.511" x 8.5" Dia. Weight- 6 lbs. Continuous Duty / Thermally protected Class B Insulation 3000 RPM Rated for Indoor or Outdoor use ICONCRETE DECK I Fan Supported Using Factory Bracket Secured To Deck Using (3) 3/8 X I % Tap Cons I 4- 4-INCH DUCT DROP CEILING SPACE 12' TOOLITSIDEWALL IRV100 FAN UNIT INSTALLED F [FRE9AJR DISCHARGE 1 114'X14- CESSPANELI JINDROPCEILING DR�MLL ROPCEILING1 Radon Mitigation Services, LLC FL State Certified Radon Mitigation Business #RB1599 3361 5th Avenue SW Naples, FL 34117 239-340-0027 Gene Yacobacci FL State Certified Radon Mitigation Specialist #R1598 FL State Certified General Contractor #CGC1520422 FL State Certified AC Contractor #CAC1816667 Ariurn Pines Lake Apartments 7769 Pine Lakes Blvd. Port St. Lucie, FL 34952 Building # I M41 0 4700 W. 161 Cleveland, C.,�.35 ACCESS ABLEO PH:8013-321-9532 ACCESS PANELS 0 FX*8OG-321-9W5 Vam.nateir.com SPECIFICATION TECHNICAL SPECIFICATION: Oatey Access Able Access Panels are designed to allow access to service areas. Access Panels can be used for aooess to plumbing, electriced, security systems, telephonp, computer cables, and sprinkler systems. Reversible feature allows for flush mounting orsurface mounting. U.S.FatentF04,890418,R5355526. Az PHYSICAUCHEMICAL PROPERTIES Material U.V. Stabilized ABS Color White DIRECTION$ FOR USE Surface Mount Installation: Cut appropriate size opening using frame as a template. Check for level. Apply construction adhesive to backside of frame flange. Fit frame Into opening. Press flange against wall to ensure flat Installation. After adhesive Is set, snap door Into place. Flush Mount Installation: Nall or screw frame into place at desired location with flange flat against the sbid. Check for level. Drywall or plaster to the top of the flange. Snap on door after wall covering is complete. Daley Access Panels provid access to service areas, while allowing an easy Installation Into wag surface. Patented dips on panel door and frame eliminate sagging or bowing of door In ceiling applications. PRODUCT I DESCRIPTION ActualDoorSize FrameSizeto Wall Opening PACIC NUMBER I Outer Flange I A I B I C I D I E I 34056 1 14" x 140 Access Panel 1 13-3/4" 1 13-Y4" 1 17' 1 17- 140 114' 16 Data is subject to manufacturing tolerances. Radon Mitigation Services, LLC FIL State Certified Radon Mitigation Business #RB1 599 33615 th Avenue SW Naples, FIL 34117 239-340-0027 Gene Yacobacci FL State Certified Radon Mitigation Specialist #R1 598 FL State Certified General Contractor #CGC1520422 FIL State Certified AC Contractor #CAC1816667 M5 I Arium Pines Lake Apartments 7769 Pine Lakes Blvd. Port St. Lucie, FL 34952 Building # I Gene Yacobacci FL State Certified Radon Mitigation Specialist #R1 598 FL State Certified General Contractor #CGC1520422 FIL State Certified AC Contractor #CAC1816667 M5 I Arium Pines Lake Apartments 7769 Pine Lakes Blvd. Port St. Lucie, FL 34952 Building # I PRODUCT ^MEFUC�A, SPECIFICATIONS and TECHNICAL AM11112! Deco Grille DATA MaidlillWA6 0810 B Part# Size Description A B C D 22 0721 9' WHITE PLASTIC (ABS).G RILLE 3" 4-3/4" 33 �72 i.. WHITE PLASTIC (ABS) GRILLE 4�- 5-3/4" 1 22 078 .5.. WHITE PLASTIC(ABS) GRILLE 5' 6-1/2" 51W 1-1/4" 1 �AkRAIEFIlaAALM @aides VIIEW-11`111-jw1c 4621 1 9th Street Court E., Suite 104, Bradenton, FL 34203 USA Phone: 941-361-34411 Fax: 941-351-3442 vvvwv.ameri canal des-com I E-mail: info@aldes-us.com 1&9 TIC PRATIC L Lim IN deco_gnlle—specj810 Naples, FIL 34117 239-340-0027 Gene Yacobacci FL State Certfied Radon Mitigation Specialist #R1 598 FL State Certified General Contractor #CGC1520422 FL State Certified AC Contractor #CAC1 816667 Radon Mitigation Services, LLC FL State Certified Radon Mitigation Business #RB1 599 33615 th Avenue SW Ariurn Pines Lake Apartments 7769 Pine Lakes Blvd. Port St. Lucie, FL 34952 Building # 1 4621 1 9th Street Court E., Suite 104, Bradenton, FL 34203 USA Phone: 941-361-34411 Fax: 941-351-3442 vvvwv.ameri canal des-com I E-mail: info@aldes-us.com 1&9 TIC PRATIC L Lim IN deco_gnlle—specj810 Naples, FIL 34117 239-340-0027 Gene Yacobacci FL State Certfied Radon Mitigation Specialist #R1 598 FL State Certified General Contractor #CGC1520422 FL State Certified AC Contractor #CAC1 816667 Radon Mitigation Services, LLC FL State Certified Radon Mitigation Business #RB1 599 33615 th Avenue SW Ariurn Pines Lake Apartments 7769 Pine Lakes Blvd. Port St. Lucie, FL 34952 Building # 1 ---dQec ttriijilt:5 In 100.00, Technical Product Fresh Air Intake Vent mfith moided plastic grid HSM4W,HSM4B (M Plastic collar (SVMAW4 only) Model No. A B C HSM4W 6' 5/-' 4' HSM4B 6' 5V 4' ,SVMAW4 6' 5V 4' 1 518.. I A j Lvj�"T.-Iw �--��lpe SZW4 only) Radon Mitigation Services, LLC FL State Certified Radon Mitigation Business #RB1 599 33615 th Avenue SW Naples, FL 34117 239-340-0027 Gene Yacobacci FL State Certified Radon Mitigation Specialist #R1598 FL State Certified General Contractor #CGC1520422 FL State Certified AC Contractor #CAC1 816667 Model No. Description Color SVMAW4 Hood/pipe/collar assem. White for all plastic molded fresh air intake vents Hood Calcium filled Polypropylene Melting POint:225- F+ C UV Inhibitor a ded Pipe Aluminum Collar - Styrene • Free Air 4" dia. = to square inches • Protective Grid Size 4"dia. = protective grid • stationary molded plastic louvers • quick, easy installation • plastic furnace fresh air intakes come with a molded screen to help prevent birds and rodents from entering • durable weather resistant Molded for easy connection of pipe Side View B so. Rear View Ariurn Pines Lake Apartments 7769 Pine Lakes Blvd. Port St. Lucie, FL 34952 Building # 1 M7 CHICAGO 121"STED E-218111 Timer Instructions: Warning: 1. The Timer is designed for indoor use only. 2. Keep this product out of the hands of children. 3. Only plug the timer into a 125VAC electrical outlet. 4. Maximum Watts: 2,000 Watts (Do not exceed). 5. Keep Timer dry at all times. Do not plug in the Timer if hands or feet are wet. 6. Plug the one or two appliances into the Timer. Set the ONIOFF switch to ON. Plug the Timer into a 125VAC electrical outlet, and the Timer set-up is complete. Setting the ON/OFT function: Note the black time indicators behind the dial. Each time indicator represents 15 minutes. When setting the ON/OFF function, you have to push the appropriate time indicators down, away from the dial. Example: Setting the light to turn on at 8 P.M. and turn off at 6 A.M. All time indicators between 20 (8 P.M.) and 6 (6 A.M.) must be pushed down, away from the dial. When setting the time indicators. Note the RED ON/OFF switch on the side of the Timer. Pushing this switch upward will activate the timer. Push this switch downward to deactivate the Timer. Easy Read Dynameter Vacuum Gauge 1. Reads 0 — 4" W.C. 2. Non -toxic Fluid 3. Adjustable zero 4. Vinyl tube connects 5, Mounts On Wall of AC closet or other visible location Radon Mitigation Services, LLC FIL State Certified Radon Mitigation Business #RB1599 33615 th Avenue SW Naples, FIL 34117 239-340-0027 Gene Yacobacci FL State Certified Radon Mitigation Specialist #R1 598 FL State Certified General Contractor #CGC1520422 FL State Certified AC Contractor #CAC1 816667 Fan ON Arium Pines Lake Apartments 7769 Pine Lakes Blvd. Port St. Lucie, FL 34952 Building # 1 M New Receptacle Installed For Radon Fan Unit. Includes UL Listed Timer RV100 Fan Installed Above Drywall Ceiling Behind Access Panel By AC Contractor Fan = 40W 0.6A 14 / 2 OR 12/ 2 ROMEX TO PANEL BOX OR GENERAL Circuit Shall Have Adequate Capacity LIGHTING CIRCUIT To Support Additional Load 20A UL Listed Timer ELECTRICAL PLANS I Receptacle — Ground Floor Unit PANEL BOX OR GENERAL LIGHTING CIRCUIT Mike Lang Electrical Cant. Arium Pines Lake Apartments 5408 San Roma Circle 7769 Pine Lakes Blvd. Lake Worth, FL 33467 Port St. Lucie, FIL 34952 561-723-2895 Building # 1 Michael T. Lang i� FL State Certified Electrical Contractor # ECO000227 & Michael T. Lang El