HomeMy WebLinkAboutDESIGN AND SPECIFICATIONRADON MITIGATION SYSTEM DESIGN AND SPECIFICATIONS
Owner: BR Carroll St. Lucie, LLC
7700 Pine Lakes Blvd SCANNED
Port St. Lucie, FL 34952 BY
St. Lucie County
PROPERTY NAME = ARIUM PINE LAKES APARTMENTS
Job Address = 7771 Pine Lakes Blvd, Port St. Lucie, FIL 34952 (Building # 1)
Contents
M1 = Radon Mitigation System Diagram (I Bed / 1 Bath)
M2 = Radon Mitigation System Diagram (Profile)
M3 = Radon Mitigation System Diagram —AC Return Closet Detail
M4 = Ventilation Fan Specification
M5 = Access Panel Specification
M6 = Deco Grill Specification (Supply Grill)
M7 = Outside Air Vent Hood Specification FILE C ff jqm N
M8 = Timer & Manometer Specification vtoy
El = Electrical Specifications
Contractors
Air Conditioning Contractor = Radon Mitigation Services, LLC
33615" Ave SW
Naples, FL 34117
Gene Yacobacci
CAC1816667
239-340-0027
Electrical Contractor = Mike Lang Electrical Cont., Inc
5408 San Roma Circle
Lake Worth, FL 33467
Michael T. Lang
ECO000227
561-723-2895
Applicable Codes
FL Building Code 2014
FL Mechanical Code 2014
Electrical Code — NEC2014
SUMEcaw"
PLANREvIEW
aok�
nue��
amede—
amne.21117
RLEMM
OVE
MMZ�
DATEja-A-12
ELECTRICAL — INSTALL RECEPTACLE &
UL LISTED TIMER / ON/ OFF SWITCH AT
ACCESS PANEL LOCATION.
Power From General Lighting Circuit. SEE El
O/A Supply To AC Return -
Deco Grill Installed In Cellirtq
UNEN Fresh Air Intake
f*%00 Vent
THE VENTILATION FAN IS
INSTALLED ABOVE THE DRYWALL
7WA I
LL
CEILING IN THE BATHROOM
A 14"X 14" ACCESS PANEL IS
INSTALLED IN THE CEILING
-14* X -11'
4-Incl �,errnoo Fin
_n'
Metal Duct R utes
bo, mll
UIANG Room Above Drywa I
'a D
Call.
13' x 1!Sw Ceiling
7 nhmm� All Wall Penetrations Are Located
PAM On Exterior Walls. No Hallway Or
13'� x 4 � Breezeway Penetrations
Applicable Codes
FL Building Code 2014
FL Mechanical Code 2014
Electrical Code — NEC2014
One Bedroom / One Bathroom
786 Sq. Ft
Radon Mitigation System Design
Mechanical Ventilation
Radon Mitigation Services, LLC Arium Pines Lake Apartments
Fl- State Certified Radon Mitigation Business #RB1599 7771 Pine Lakes Blvd.
3361 5th Avenue SW Port St. Lucie, FIL 34952
Naples, FIL 34117 Building # 1
239-340-0027
Gene Yacobacci
FL State Certified Radon Mitigation Specialist #R1 598
FL State Certified General Contractor #CGC1520422
FL State Certified AC Contractor #CAC1816667 Gene Yacobacci M 1
System Failure Device
U-Tube Manometer,
Installed In Each AC
Closet.
Upper Floor Unit (8)
No Access Required
Radon Mitigation System Design
Radon Mitigation Services, LLC
FL State Certified Radon Mitigation Business #RB1599
3361 5th Avenue SW
Naples, FL 34117
239-340-0027
Gene Yacobacci
Fl- State Certified Radon Mitigation Specialist #R1598
Fl- State Certified General Contractor #CGC1520422
FL State Certified AC Contractor #CAC1816667
Outside Air
Intake Vent Hood
Exterior Block
wall
Ariurn Pines Lake Apartments
7771 Pine Lakes Blvd.
Port St. Lucie, FL 34952
Building # 1
L
4-Inch Radon Duct
4-INCH DECO GRILL
Fresh air Supply
AIR HANDLER
System Failure Device
U-Tube Manometer
Installed In Each AC
Closet.
WATER
HEATER
SUPPLY AIR DUCT
Mechanical Closet Profile - Typical All Units
Radon Mitigation Services, ILLC
FL State Certified Radon Mitigation Business #RB1 599
33615 0 Avenue SW
Naples, FL 34117
239-340-0027
Gene YacobaGCi
FL State Certified Radon Mitigation Specialist #R1 598
FL State Certified General Contractor #CGC1520422
FL State Certified AC Contractor #CAC1 816667
Ariurn Pines Lake Apartments
7771 Pine Lakes Blvd.
Port St. Lucie, FL 34952
Building # 1
M3-
F '��,ON FAN SPEC IFI CATION' S--
RADONAWAY (SPRUCE) RV100
Designed specially for radon mitigation, RV
Series Fans provide superb performance, use
little electric power, run ultra quiet and are
attractive. An ideal choice for most radon
mitigation systems. Model selection is
dependent on building characteristics and
should be made by a radon professional.
r
*Typical monthly electric cost $1.00 - $2.00 depending on model, electric rates & operating conditions.
a
Maximum
Typical CIFM vs Static Pressure WC"
Pressure
100 IF 80
5 - Year Warranty.
Mounts on duct
4" diameter ducts.
Rugged .125" Noryl plastic housing.
Electrical box for hard wire or plug in.
ETL Safety Agency Listed - tested to UL Standard 507 for indoor or outdoor use. Meets all electrical code
requirements.
Size: 9.511" x 8.5" Dia. Weight 6 lbs. Continuous Duty / Thermally protected
Class B Insulation 3000 RPM Rated for Indoor or Outdoor use
ICONCRETE DECK I
Fan Supported Using Factory Bracket Secured To
Deck Using (3) 3/8 X 1 % Tap Cons I
N �& 4 A # 4
A
"D4- 4-INCH DUCT
ROP CEILING SPACE 12" TOOUTSIDEWALL
IRVIOD FAN UNIT INSTALLED
[FRE;iAIR DISCHARGE 1 114'X14- CESSPANELI JINDROPCEILING 1DRYWALL DROP CEFILING
Radon Mitigation Services, LLC
FL State Certified Radon Mitigation Business #RB1 599
3361 5th Avenue SW
Naples, FIL 34117
239-340-0027
Gene Yacobacci
FL State Certified Radon Mitigation Specialist #R1 598
FL State Certified General Contractor #CGC1520422
FL State Certified AC Contractor #CAC1 816667
Arium Pines Lake Apartments
7771 Pine Lakes Blvd.
Port St. Lucie, FIL 34952
Building # 1
M41
0 4700 16
W
cle"114 ACCESS ABLEP
P111:81IM21-9532 ACCESS PANELS IWUMIDW
FX81110-321-9535
www.oaley.com
.SPECIRCATIDN
TECHNICAL SPECIFICATION: Oatey Access Able Access Panels are designed to allow access to service areas. Access
Panels can be used for access to plumbing, eJectrical, security systems, telephone, computer cables, and sprinkler systenm
Reversible feature allows for flush mounting or surface mounting. U.S. F1atw1s#489Q4J8&5355526.
IZ
-L IA
PHYSICALICHEMICAL PROPERTIES
Material UN. Stabilized Ass
Color White
DXRF-CBONS FOR USE
Surface Mount Installation: Cut appropriate size
opening using frame as a template. Check for level. Apply
constructon adhesive to backside of frame flange. Pit
frame Into opening. Press flange against wall to ensure flat
Installailon. After adhesive Is set, snap door Into place.
Flush Mount Installation: Nall or screw frame Into place
at desired location with flange flat against the stud. Check
forlevel. Drywall or plaster to the top of the flange. Snap
on door after wall covering Is complete.
Oatey Access Panels provide access to service areas, while
allowing an easy Installallon Into wall surface. Patented
clips on panel door and frame eliminate sagging or bowing
of door In ceiling applications.
PRODUCT ESCRIP71ON ActualDoorSlze FrameSizveto Wall Opening PACK
Outer Flange
I E I F
34056 114" x 14"Access Panel 13-Y4m 1 13-V4" 1 17a 1 17' 14" 14' 16
Data Is subject to manufacturing tolerances.
Radon Mitigation Services, LLC
FL State Certified Radon Mitigation Business #RB1 599
3361 5th Avenue SW
Naples, FL 34117
239-340-0027
Gene Yacobaccii
FL State Certified Radon Mitigation Specialist #R1 598
FL State Certified General Contractor #CGC1 520422
FL State Certified AC Contractor #CAC1816667
M5
Ariurn Pines Lake Apartments
7771 Pine Lakes Blvd.
Port St. Lucie, FL 34952
Building # 1
Gene Yacobaccii
FL State Certified Radon Mitigation Specialist #R1 598
FL State Certified General Contractor #CGC1 520422
FL State Certified AC Contractor #CAC1816667
M5
Ariurn Pines Lake Apartments
7771 Pine Lakes Blvd.
Port St. Lucie, FL 34952
Building # 1
PRODUCT
SPECIFICATIONS
and TECHNICAL
Maides- Deco Grille DATA
0810
J4kMlEF%1C;JqLN
Maldes
VIEN-ir
4521 1 ft Street Court E., Suite 104, Bradenton, FL 34203 USA
Phone: 941-351-34411 Fax: 941-351-3442
wwmarnericanaldes.com I E-mail: info@aldes-us.com
Part# Size Desuiption A B C D
ELAH (ABS)GRILLE 3" 4-3/4" 1/V 5/8"
Pasr!iS
2
22 E7
F2 o7 4 WHITE ABS)GRILLE 4" 5-3/4" 11/16" V
22078 V' WAITE PLASTIC (ABS) GRILLE 5' 6-1/2" 5/9' 1-lfil"
1A
UTIC
Lim
771
decq_griIIe_specj8l0
Gene Yacobacci
FL State Certified Radon Mitigation Specialist #R1 598
FIL State Certified General Contractor #CGC 1520422
FL State Certified AC Contractor #CAC1 816667
M6
Radon Mitigation Services, LLC
FL State Certified Radon Mitigation Business #RB1 599
33615 Ih Avenue SW
Naples, FL 34117
239-340-0027
Ariurn Pines Lake Apartments
7771 Pine Lakes Blvd.
Port St. Lucie, FIL 34952
Building # 1
Part# Size Desuiption A B C D
ELAH (ABS)GRILLE 3" 4-3/4" 1/V 5/8"
Pasr!iS
2
22 E7
F2 o7 4 WHITE ABS)GRILLE 4" 5-3/4" 11/16" V
22078 V' WAITE PLASTIC (ABS) GRILLE 5' 6-1/2" 5/9' 1-lfil"
1A
UTIC
Lim
771
decq_griIIe_specj8l0
Gene Yacobacci
FL State Certified Radon Mitigation Specialist #R1 598
FIL State Certified General Contractor #CGC 1520422
FL State Certified AC Contractor #CAC1 816667
M6
Radon Mitigation Services, LLC
FL State Certified Radon Mitigation Business #RB1 599
33615 Ih Avenue SW
Naples, FL 34117
239-340-0027
Ariurn Pines Lake Apartments
7771 Pine Lakes Blvd.
Port St. Lucie, FIL 34952
Building # 1
�ware
Technical Product Specifications
Fresh Air Intake Vent with molded plastic grid
HSM4W,HSM4B
(CD
Plastic collar
(SVMAW4 Only)
Model No. I
A
B
C
HSM4W
6*
5/-"
4'
HSN14B
SVMAW4
6-
5
4-
5/9'
I
A
I
SVMAW4
go
���Wp- SVMAW4 only)
Radon Mitigation Services, LLC
Fl- State Certified Radon Mitigation Business #RB1 599
3361 e Avenue SW
Naples, FL 34117
239-340-0027
Gene Yacobacci
FL State Certified Radon Mitigation Specialist #111598
FL State Certified General Contractor #CGC1520422
FL State Cerfified AC Contractor #CAC1816667
Model No. Description Color
SVMAW4lHood/pipe/collarassem. Whilt,
Hood
Calcium filled Polypropylene
• Melting Point: 3250 F+
• UV Inhibitor added
Pipe
Aluminum
Collar
- Styrene
• Free Air
4" dia. = io square inches
• Protective Grid Size
4"dia. = protective grid
• stationary molded plastic louvers
• quick, easy installation
• plastic furnace fresh air intakes come
with a molded screen to help prevent
birds and rodents from entering
• durable weather resistant
Molded for easy
connection of pipe
Side View
B sq.
Rear View
Arium Pines Lake Apartments
7771 Pine Lakes Blvd.
Port St. Lucie, FL 34952
Building # 1
M7
CHICAGO
-2KA8.
MED
Timer Instructions:
Warning:
1. The Timer is designed for indoor use only. 2. Keep this product out of the hands of children. 3. Only
plug the timer into a 125VAC electrical outlet. 4. Maximum Watts: 2,000 Watts (Do not exceed).
5. Keep Timer dry at all times. Do not plug in the Timer if hands or feet are wet. 6. Plug the one or two
appliances into the Timer. Set the ON/OFF switch to ON. Plug the Timer into a 125VAC electrical
outlet, and the Timer set-up is complete.
Setting the ON/OFF function: Note the black time indicators behind the dial. Each time indicator
represents 15 minutes. When setting the ONIOFF function, you have to push the appropriate time
indicators down, away from the dial. Example: Setting the light to turn on at 8 P.M. and turn off at 6
A.M. All time indicators between 20 (8 P.M.) and 6 (6 A.M.) must be pushed down, away from the dial.
When setting the time indicators.
Note the RED ON/OFF switch on the side of the Timer. Pushing this switch upward will activate the
timer. Push this switch downward to deactivate the Timer.
Easy Read Dynameter
Vacuum Gauge
1. Reads 0 — 4" W.C.
2. Non -toxic Fluid
3. Adjustable zero
4. Vinyl tube connects
5. Mounts On Wall of AC closet or other visible
location
Radon Mitigation Services, LLC
FL State Certified Radon Mitigation Business #RB1 599
3361 5th Avenue SW
Naples, FL 34117
239-340-0027
Gene Yacobacci
FL State Certified Radon Mitigation Specialist #R1 598
FL State Certified General Contractor #CGC1520422
FL State Certified AC Contractor #CAC1 816667
Fan ON
Arium Pines Lake Apartments
7771 Pine Lakes Blvd.
Port St. Lucie, FIL 34952
Building # 1
M
r_1
iku
New Receptacle
Installed For Radon
Fan Unit. Includes
UL Listed Timer
RV100 Fan Installed
Above Drywall Ceiling
Behind Access Panel By
AC Contractor
Fan = 40W 0.6A 14 / 2 OR 12/ 2 ROMEX TO
PANEL BOX OR GENERAL
Circuit Shall Have Adequate Capacity LIGHTING CIRCUIT
To Support Additional Load
20A UL Listed
Timer
ELECTRICAL PLANS
1 Receptacle — Ground Floor Unit
PANEL BOX OR
GENERAL LIGHTING
CIRCUIT
Mike Lang Electrical Cont Arium Pines Lake Apartments
5408 San Roma Circle 7771 Pine Lakes Blvd.
Lake Worth, FL 33467 Port St. Lucie, FL 34952
561-723-2895 Building # 1
Michael T. Lang 0:�
FL State Certified Electrical Contractor # ECO000227 &
Michael T. Lang El