Loading...
HomeMy WebLinkAboutDESIGN AND SPECIFICATIONRADON MITIGATION SYSTEM DESIGN AND SPECIFICATIONS Owner: BR Carroll St. Lucie, LLC 7700 Pine Lakes Blvd SCANNED Port St. Lucie, FL 34952 BY St. Lucie County PROPERTY NAME = ARIUM PINE LAKES APARTMENTS Job Address = 7771 Pine Lakes Blvd, Port St. Lucie, FIL 34952 (Building # 1) Contents M1 = Radon Mitigation System Diagram (I Bed / 1 Bath) M2 = Radon Mitigation System Diagram (Profile) M3 = Radon Mitigation System Diagram —AC Return Closet Detail M4 = Ventilation Fan Specification M5 = Access Panel Specification M6 = Deco Grill Specification (Supply Grill) M7 = Outside Air Vent Hood Specification FILE C ff jqm N M8 = Timer & Manometer Specification vtoy El = Electrical Specifications Contractors Air Conditioning Contractor = Radon Mitigation Services, LLC 33615" Ave SW Naples, FL 34117 Gene Yacobacci CAC1816667 239-340-0027 Electrical Contractor = Mike Lang Electrical Cont., Inc 5408 San Roma Circle Lake Worth, FL 33467 Michael T. Lang ECO000227 561-723-2895 Applicable Codes FL Building Code 2014 FL Mechanical Code 2014 Electrical Code — NEC2014 SUMEcaw" PLANREvIEW aok� nue�� amede— amne.21117 RLEMM OVE MMZ� DATEja-A-12 ELECTRICAL — INSTALL RECEPTACLE & UL LISTED TIMER / ON/ OFF SWITCH AT ACCESS PANEL LOCATION. Power From General Lighting Circuit. SEE El O/A Supply To AC Return - Deco Grill Installed In Cellirtq UNEN Fresh Air Intake f*%00 Vent THE VENTILATION FAN IS INSTALLED ABOVE THE DRYWALL 7WA I LL CEILING IN THE BATHROOM A 14"X 14" ACCESS PANEL IS INSTALLED IN THE CEILING -14* X -11' 4-Incl �,errnoo Fin _n' Metal Duct R utes bo, mll UIANG Room Above Drywa I 'a D Call. 13' x 1!Sw Ceiling 7 nhmm� All Wall Penetrations Are Located PAM On Exterior Walls. No Hallway Or 13'� x 4 � Breezeway Penetrations Applicable Codes FL Building Code 2014 FL Mechanical Code 2014 Electrical Code — NEC2014 One Bedroom / One Bathroom 786 Sq. Ft Radon Mitigation System Design Mechanical Ventilation Radon Mitigation Services, LLC Arium Pines Lake Apartments Fl- State Certified Radon Mitigation Business #RB1599 7771 Pine Lakes Blvd. 3361 5th Avenue SW Port St. Lucie, FIL 34952 Naples, FIL 34117 Building # 1 239-340-0027 Gene Yacobacci FL State Certified Radon Mitigation Specialist #R1 598 FL State Certified General Contractor #CGC1520422 FL State Certified AC Contractor #CAC1816667 Gene Yacobacci M 1 System Failure Device U-Tube Manometer, Installed In Each AC Closet. Upper Floor Unit (8) No Access Required Radon Mitigation System Design Radon Mitigation Services, LLC FL State Certified Radon Mitigation Business #RB1599 3361 5th Avenue SW Naples, FL 34117 239-340-0027 Gene Yacobacci Fl- State Certified Radon Mitigation Specialist #R1598 Fl- State Certified General Contractor #CGC1520422 FL State Certified AC Contractor #CAC1816667 Outside Air Intake Vent Hood Exterior Block wall Ariurn Pines Lake Apartments 7771 Pine Lakes Blvd. Port St. Lucie, FL 34952 Building # 1 L 4-Inch Radon Duct 4-INCH DECO GRILL Fresh air Supply AIR HANDLER System Failure Device U-Tube Manometer Installed In Each AC Closet. WATER HEATER SUPPLY AIR DUCT Mechanical Closet Profile - Typical All Units Radon Mitigation Services, ILLC FL State Certified Radon Mitigation Business #RB1 599 33615 0 Avenue SW Naples, FL 34117 239-340-0027 Gene YacobaGCi FL State Certified Radon Mitigation Specialist #R1 598 FL State Certified General Contractor #CGC1520422 FL State Certified AC Contractor #CAC1 816667 Ariurn Pines Lake Apartments 7771 Pine Lakes Blvd. Port St. Lucie, FL 34952 Building # 1 M3- F '��,ON FAN SPEC IFI CATION' S-- RADONAWAY (SPRUCE) RV100 Designed specially for radon mitigation, RV Series Fans provide superb performance, use little electric power, run ultra quiet and are attractive. An ideal choice for most radon mitigation systems. Model selection is dependent on building characteristics and should be made by a radon professional. r *Typical monthly electric cost $1.00 - $2.00 depending on model, electric rates & operating conditions. a Maximum Typical CIFM vs Static Pressure WC" Pressure 100 IF 80 5 - Year Warranty. Mounts on duct 4" diameter ducts. Rugged .125" Noryl plastic housing. Electrical box for hard wire or plug in. ETL Safety Agency Listed - tested to UL Standard 507 for indoor or outdoor use. Meets all electrical code requirements. Size: 9.511" x 8.5" Dia. Weight 6 lbs. Continuous Duty / Thermally protected Class B Insulation 3000 RPM Rated for Indoor or Outdoor use ICONCRETE DECK I Fan Supported Using Factory Bracket Secured To Deck Using (3) 3/8 X 1 % Tap Cons I N �& 4 A # 4 A "D4- 4-INCH DUCT ROP CEILING SPACE 12" TOOUTSIDEWALL IRVIOD FAN UNIT INSTALLED [FRE;iAIR DISCHARGE 1 114'X14- CESSPANELI JINDROPCEILING 1DRYWALL DROP CEFILING Radon Mitigation Services, LLC FL State Certified Radon Mitigation Business #RB1 599 3361 5th Avenue SW Naples, FIL 34117 239-340-0027 Gene Yacobacci FL State Certified Radon Mitigation Specialist #R1 598 FL State Certified General Contractor #CGC1520422 FL State Certified AC Contractor #CAC1 816667 Arium Pines Lake Apartments 7771 Pine Lakes Blvd. Port St. Lucie, FIL 34952 Building # 1 M41 0 4700 16 W cle"114 ACCESS ABLEP P111:81IM21-9532 ACCESS PANELS IWUMIDW FX81110-321-9535 www.oaley.com .SPECIRCATIDN TECHNICAL SPECIFICATION: Oatey Access Able Access Panels are designed to allow access to service areas. Access Panels can be used for access to plumbing, eJectrical, security systems, telephone, computer cables, and sprinkler systenm Reversible feature allows for flush mounting or surface mounting. U.S. F1atw1s#489Q4J8&5355526. IZ -L IA PHYSICALICHEMICAL PROPERTIES Material UN. Stabilized Ass Color White DXRF-CBONS FOR USE Surface Mount Installation: Cut appropriate size opening using frame as a template. Check for level. Apply constructon adhesive to backside of frame flange. Pit frame Into opening. Press flange against wall to ensure flat Installailon. After adhesive Is set, snap door Into place. Flush Mount Installation: Nall or screw frame Into place at desired location with flange flat against the stud. Check forlevel. Drywall or plaster to the top of the flange. Snap on door after wall covering Is complete. Oatey Access Panels provide access to service areas, while allowing an easy Installallon Into wall surface. Patented clips on panel door and frame eliminate sagging or bowing of door In ceiling applications. PRODUCT ESCRIP71ON ActualDoorSlze FrameSizveto Wall Opening PACK Outer Flange I E I F 34056 114" x 14"Access Panel 13-Y4m 1 13-V4" 1 17a 1 17' 14" 14' 16 Data Is subject to manufacturing tolerances. Radon Mitigation Services, LLC FL State Certified Radon Mitigation Business #RB1 599 3361 5th Avenue SW Naples, FL 34117 239-340-0027 Gene Yacobaccii FL State Certified Radon Mitigation Specialist #R1 598 FL State Certified General Contractor #CGC1 520422 FL State Certified AC Contractor #CAC1816667 M5 Ariurn Pines Lake Apartments 7771 Pine Lakes Blvd. Port St. Lucie, FL 34952 Building # 1 Gene Yacobaccii FL State Certified Radon Mitigation Specialist #R1 598 FL State Certified General Contractor #CGC1 520422 FL State Certified AC Contractor #CAC1816667 M5 Ariurn Pines Lake Apartments 7771 Pine Lakes Blvd. Port St. Lucie, FL 34952 Building # 1 PRODUCT SPECIFICATIONS and TECHNICAL Maides- Deco Grille DATA 0810 J4kMlEF%1C;JqLN Maldes VIEN-ir 4521 1 ft Street Court E., Suite 104, Bradenton, FL 34203 USA Phone: 941-351-34411 Fax: 941-351-3442 wwmarnericanaldes.com I E-mail: info@aldes-us.com Part# Size Desuiption A B C D ELAH (ABS)GRILLE 3" 4-3/4" 1/V 5/8" Pasr!iS 2 22 E7 F2 o7 4 WHITE ABS)GRILLE 4" 5-3/4" 11/16" V 22078 V' WAITE PLASTIC (ABS) GRILLE 5' 6-1/2" 5/9' 1-lfil" 1A UTIC Lim 771 decq_griIIe_specj8l0 Gene Yacobacci FL State Certified Radon Mitigation Specialist #R1 598 FIL State Certified General Contractor #CGC 1520422 FL State Certified AC Contractor #CAC1 816667 M6 Radon Mitigation Services, LLC FL State Certified Radon Mitigation Business #RB1 599 33615 Ih Avenue SW Naples, FL 34117 239-340-0027 Ariurn Pines Lake Apartments 7771 Pine Lakes Blvd. Port St. Lucie, FIL 34952 Building # 1 Part# Size Desuiption A B C D ELAH (ABS)GRILLE 3" 4-3/4" 1/V 5/8" Pasr!iS 2 22 E7 F2 o7 4 WHITE ABS)GRILLE 4" 5-3/4" 11/16" V 22078 V' WAITE PLASTIC (ABS) GRILLE 5' 6-1/2" 5/9' 1-lfil" 1A UTIC Lim 771 decq_griIIe_specj8l0 Gene Yacobacci FL State Certified Radon Mitigation Specialist #R1 598 FIL State Certified General Contractor #CGC 1520422 FL State Certified AC Contractor #CAC1 816667 M6 Radon Mitigation Services, LLC FL State Certified Radon Mitigation Business #RB1 599 33615 Ih Avenue SW Naples, FL 34117 239-340-0027 Ariurn Pines Lake Apartments 7771 Pine Lakes Blvd. Port St. Lucie, FIL 34952 Building # 1 �ware Technical Product Specifications Fresh Air Intake Vent with molded plastic grid HSM4W,HSM4B (CD Plastic collar (SVMAW4 Only) Model No. I A B C HSM4W 6* 5/-" 4' HSN14B SVMAW4 6- 5 4- 5/9' I A I SVMAW4 go ���Wp- SVMAW4 only) Radon Mitigation Services, LLC Fl- State Certified Radon Mitigation Business #RB1 599 3361 e Avenue SW Naples, FL 34117 239-340-0027 Gene Yacobacci FL State Certified Radon Mitigation Specialist #111598 FL State Certified General Contractor #CGC1520422 FL State Cerfified AC Contractor #CAC1816667 Model No. Description Color SVMAW4lHood/pipe/collarassem. Whilt, Hood Calcium filled Polypropylene • Melting Point: 3250 F+ • UV Inhibitor added Pipe Aluminum Collar - Styrene • Free Air 4" dia. = io square inches • Protective Grid Size 4"dia. = protective grid • stationary molded plastic louvers • quick, easy installation • plastic furnace fresh air intakes come with a molded screen to help prevent birds and rodents from entering • durable weather resistant Molded for easy connection of pipe Side View B sq. Rear View Arium Pines Lake Apartments 7771 Pine Lakes Blvd. Port St. Lucie, FL 34952 Building # 1 M7 CHICAGO -2KA8. MED Timer Instructions: Warning: 1. The Timer is designed for indoor use only. 2. Keep this product out of the hands of children. 3. Only plug the timer into a 125VAC electrical outlet. 4. Maximum Watts: 2,000 Watts (Do not exceed). 5. Keep Timer dry at all times. Do not plug in the Timer if hands or feet are wet. 6. Plug the one or two appliances into the Timer. Set the ON/OFF switch to ON. Plug the Timer into a 125VAC electrical outlet, and the Timer set-up is complete. Setting the ON/OFF function: Note the black time indicators behind the dial. Each time indicator represents 15 minutes. When setting the ONIOFF function, you have to push the appropriate time indicators down, away from the dial. Example: Setting the light to turn on at 8 P.M. and turn off at 6 A.M. All time indicators between 20 (8 P.M.) and 6 (6 A.M.) must be pushed down, away from the dial. When setting the time indicators. Note the RED ON/OFF switch on the side of the Timer. Pushing this switch upward will activate the timer. Push this switch downward to deactivate the Timer. Easy Read Dynameter Vacuum Gauge 1. Reads 0 — 4" W.C. 2. Non -toxic Fluid 3. Adjustable zero 4. Vinyl tube connects 5. Mounts On Wall of AC closet or other visible location Radon Mitigation Services, LLC FL State Certified Radon Mitigation Business #RB1 599 3361 5th Avenue SW Naples, FL 34117 239-340-0027 Gene Yacobacci FL State Certified Radon Mitigation Specialist #R1 598 FL State Certified General Contractor #CGC1520422 FL State Certified AC Contractor #CAC1 816667 Fan ON Arium Pines Lake Apartments 7771 Pine Lakes Blvd. Port St. Lucie, FIL 34952 Building # 1 M r_1 iku New Receptacle Installed For Radon Fan Unit. Includes UL Listed Timer RV100 Fan Installed Above Drywall Ceiling Behind Access Panel By AC Contractor Fan = 40W 0.6A 14 / 2 OR 12/ 2 ROMEX TO PANEL BOX OR GENERAL Circuit Shall Have Adequate Capacity LIGHTING CIRCUIT To Support Additional Load 20A UL Listed Timer ELECTRICAL PLANS 1 Receptacle — Ground Floor Unit PANEL BOX OR GENERAL LIGHTING CIRCUIT Mike Lang Electrical Cont Arium Pines Lake Apartments 5408 San Roma Circle 7771 Pine Lakes Blvd. Lake Worth, FL 33467 Port St. Lucie, FL 34952 561-723-2895 Building # 1 Michael T. Lang 0:� FL State Certified Electrical Contractor # ECO000227 & Michael T. Lang El