Loading...
HomeMy WebLinkAboutDESIGN AND SPECIFICATIONRADON MITIGATION SYSTEM DESIGN AND SPECIFICATIONS Owner: BR Carroll St. Lucie, LLC 7700 Pine Lakes Blvd Port St. Lucie, FL 34952 SCANNED BY St. Lucie County PROPERTY NAME = ARIUM PINE LAKES APARTMENTS Job Address = 7773 Pine Lakes Blvd, Port St. Lucie, FIL 34952 (Building # 1) Contents M1 = Radon Mitigation System Diagram (2 Bed 12 Bath) M2 = Radon Mitigation System Diagram (Profile) M3 = Radon Mitigation System Diagram — AC Return Closet Detail M4 = Ventilation Fan Specification M5 = Access Panel Specification M6 = Deco Grill Specification (Supply Grill) M7 = Outside Air Vent Hood Specification M8 = Timer & Manometer Specification El = Electrical Specifications Contractors Air Conditioning Contractor = Radon Mitigation Services, 3361 5�� Ave SW Naples, FL 34117 Gene Yacobacci CAC1816667 239-340-0027 Electrical Contractor = Mike Lang Electrical Cont., Inc 5408 San Roma Circle Lake Worth, FL 33467 Michael T. Lang ECO000227 561-723-2895 Applicable Codes FL Building Code 2014 FL Mechanical Code 2014 Electrical Code — NEC2014 LLC ZrIUCIE COUNW ' PLM REMEW em: DATE' ELEQ PLUMB;__ I A ' :D R o OA O/A Supply To AC Return - Dew Grill Installed In Ceiling Lmnir-3. FRCAom 1 3r X 1�6p PA110; 13'x 4 Fill 4-Inch Thermo Fin Metal Duct Routes Above Drywall Ceiling THE VENTILATION FAN IS INSTAT I ED ABOVE THE DRYWALL CEILING IN THE BEDROOM CLOSET A 14"X 14" ACCESS PANEL IS INSTALLED IN THE CEILING B10 rd 1 -1 � X M00174" ELECTRICAL— INSTALL RECEPTACLE & UL LISTED TIMER / DISCONNECT AT ACCESS PANEL LOCATION. Power From General Lighting Circuit. SEE El I All Wall Penetrations Are Located Fresh Air Intake On Exterior Walls. No Hallway Or Vent Breezeway Penetrations Two Bedroom / Two Bathroom 1,039 Sq. Ft. Radon Mitigation System Design Mechanical Ventilation Radon Mitigation Services, ILLC FL State Certified Radon Mitigation Business #RB1 599 33615 th Avenue SW Naples, FL 34117 239-340-0027 Gene Yacobacci FL State Certified Radon Mitigation Specialist #R1 598 FL State Certified General Contractor #CGC1520422 FL State Certified AC Contractor #CAC1 816667 Arium Pines Lake Apartments 7773 Pine Lakes Blvd. Port St. Lucie, FL 34952 Building # 1 I 1V Yacobacci M 1 System Failure Device U-Tube Manometer — Installed In Each AC Closet. 12-Inches Air Handier Return Closet 3MW Upper Floor Unit (S) No Access Required Concrete Deck i 14"x 14" 4-Inch Metal Duct Access Panel Timer —Plugs In To New Receptacle Drywall Ventilation Fan ling. InstalledAbove Drywall Ceiling .' � A , - A% Radon Mitigation System Design Outside Air Intake Vent Hood Exterior Block Wall Radon Mitigation Services, LLC Arium Pines Lake Apartments FL State Certified Radon Mitigation Business #RB1599 7773 Pine Lakes Blvd. 33615 th Avenue SW Port St. Lucie, FL 34952 Naples, FIL 34117 Building # 1 239-340-0027 Gene Yacobacci FL State Certified Radon Mitigation Specialist #R1 598 FL State Certified General Contractor #CGC1520422 FL State Certified AC Contractor #CAC1 816667 M21 4-Inch Radon Duct 4-INCH DECO GRILL Fresh air Supply VFZ9,7M,F11 IWIZ System Failure Device U-Tube Manometer Installed In Each AC Closet. WATER HEATER SUPPLY AIR DUCT Mechanical Closet Profile - Typical All Units Radon Mitigation Services, LLC FIL State Certified Radon Mitigation Business #RB1599 33615 th Avenue SW Naples, FL 34117 239-340-0027 Gene Yacobacci FIL State Certified Radon Mitigation Specialist #R1 698 FL State Certified General Contractor #CGC 1520422 FIL State Certified AC Contractor #CAC1 816667 Ariurn Pines Lake Apartments 7773 Pine Lakes Blvd. Port St. Lucie, FIL 34952 Building # 1 M3. DON FAN SPECIFICATION" RADONAWAY (SPRUCE) RV100 Designed specially for radon mitigation, RV Series Fans provide superb performance, use little electric power, run ultra quiet and are attractive. An ideal choice for most radon mitigation systems. Model selection is dependent on building characteristics and should be made by a radon professional. 9.5" *Typical monthly electric cost $1.00 - $2.00 depending on model, electric rates & operating conditions. (a Maximum IF-- Typical CFM vs; Static Pressure -WC" -A Pressure F-1-00--] 357 5 - Year Wa rra nty. Mounts on duct 4" diameter ducts. Rugged .125" Noryl plastic housing. Electrical box for hard wire or plug in. ETL Safety Agency Listed - tested to UL Standard 507 for indoor or outdoor use. Meets all electrical code requirements. Size: 9.51-1" x 8.5" Dia. Weight- 6 lbs. Continuous Duty / Thermally protected Class B Insulation 3000 RPM Rated for Indoor or Outdoor use Fan Supported Using Factory Bracket Secured To Deck Using (3) 3/8 X I % Tap Cons X INCH DUCT 4- 4- DROP CEILING SPACE 120 TOOUTSIDEWALL -- - - - - - - - - - - RV100 FAN UNIT INSTALLED FFRE7AIR DISCHARGE I jWX14- CESSPANELI E I IN DROP CEILING DR�ELL DROP CEILING Radon Mitigation Services, ILLC FL State Certified Radon Mitigation Business #RB1 599 3361 !�h Avenue SW Naples, FL 34117 239-340-0027 Gene Yacobacci FL State Certified Radon Mitigation Specialist #R1 598 FL State Certified General Contractor #CGC1520422 FL State Certified AC Contractor #CAC1 816667 Arium Pines Lake Apartments 7773 Pine Lakes Blvd. Port St. Lucie, FIL 34952 Building # 1 M4 C) 4700W.16 Cleveland, �-- , as ACCESS ABLIP ACCESS PANELS [Igo Saw Ute www.oatey.com .SPECIFICATION TECHNICAL SPECIFICATION: Oatey Access Able Access Panels are designed to allow access to serAce areas. Acnes Panels can be used for access to plumbing, electrical, security systems, telephone, computer cables, and sprinkler systems. Reversible feature allows for flush mounting or surface mounting. V—%PjtentF#489Q418&5355526. PHYSICAL/CHEMXCAL PROPERnES Material UN. Stabilized ASS Color White DIRECTIONS FOR USE Surface Mount Installation- Cut appropriate size opening using frame as a template. Check for level. Apply construction adhesive to backside of frame flange. Fit frame Into opening. Press Range against wall to ensure flat Installation. After adhesive Is set, snap door Into place. Flush Mount Installation: Nall or screw frame Into place at desired location with flange flat against the stud. Check for level. Drywall or plaster to the top of the flange. Snap on door after wall covering Is complete. DNS Oatey Access Panels provide access to smice areas, while allowling an easy Installation Into wall surface. Patented clips on panel door and frame eliminate sagging or bowing of door In ceiling applications. PRODUCT DESCRIPTION ActuaIDoorSIze FrameStreto Wall Opening PACK NUMBER I I Outer Flange I A I B I C I D E 34056 1 140 x 14" Access Panel 13-Y40 13—V40 170 17- 1 14' 14- 6 Data is subject to manufaciuring tolerances. Radon Mitigation Services, LLC FL State Certified Radon Mitigation Business #RB1 599 33615 1h Avenue SW Naples, FL 34117 239-340-0027 Gene Yacobacci FL State Certified Radon Mitigation Specialist #R1 598 FL State Certified General Contractor #CGC1520422 FL State Certified AC Contractor #CAC1 816667 M5 Arium Pines Lake Apartments 7773 Pine Lakes Blvd. Port St. Lucie, FL 34952 Building # 1 Gene Yacobacci FL State Certified Radon Mitigation Specialist #R1 598 FL State Certified General Contractor #CGC1520422 FL State Certified AC Contractor #CAC1 816667 M5 Arium Pines Lake Apartments 7773 Pine Lakes Blvd. Port St. Lucie, FL 34952 Building # 1 ( PRODUCT A0kMEFt1C;A,,__ SPECIFICATIONS and TECHNICAL Maldes Deco Grille DATA 0810 C pa�" L' ze Description A B C D WHITEP LASTIC(!n��G� 1 4-a14" 11T' 5/8" ABS) �R�� 33 L72 I" VVH ITE PLASTI C ( LLE 4': 5-3/4" 11/16" V U 078 5 1. WHITE PLASTIC (ABS) GRILLE 5' 1 6-112" 1 5/&' 1 1-1/0 ^ME=-F11C;^N Maides 4521 1 9th Street Court E.. Suite 104, Bradenton, FL 34203 USA Phone: 941-351-34411 Fax: 941-351-3442 wwmamericanaldes.com I E-mail: info@aldes-us.com 1AIR 0Tin LATIG JNE 7749 deco_gn11e_spec.0910 Gene Yacobacci FL State Certified Radon Mitigation Specialist #R1 598 FL State Certified General Contractor #CGC1520422 FL State Certified AC Contractor #CAC1 816667 M6 Radon Mitigation Services, LLC FL State Certified Radon Mitigation Business #RB1599 3361 5to Avenue SW Naples, FL 34117 239-340-0027 Ariurn Pines Lake Apartments 7773 Pine Lakes Blvd. Port St. Lucie, FL 34952 Building # 1 4521 1 9th Street Court E.. Suite 104, Bradenton, FL 34203 USA Phone: 941-351-34411 Fax: 941-351-3442 wwmamericanaldes.com I E-mail: info@aldes-us.com 1AIR 0Tin LATIG JNE 7749 deco_gn11e_spec.0910 Gene Yacobacci FL State Certified Radon Mitigation Specialist #R1 598 FL State Certified General Contractor #CGC1520422 FL State Certified AC Contractor #CAC1 816667 M6 Radon Mitigation Services, LLC FL State Certified Radon Mitigation Business #RB1599 3361 5to Avenue SW Naples, FL 34117 239-340-0027 Ariurn Pines Lake Apartments 7773 Pine Lakes Blvd. Port St. Lucie, FL 34952 Building # 1 ec tm%, ware C!� Technical Product Specifications sh Air Intake Vent with molded plastic grid Made[ No. Description Color SVMAW4 Hood/pipe/collar assem. White HSM4W,HSIM4B 4- (CD Plastic collar (SVMAW4 Only) Model No. A B I C HSM4W 6" 5%" 4" HSM413 �jl 4- SVMAW4 6. 5 1�.j 5111" I A I SVMAW4 (pipe SVMAW4 Only) Radon Mitigation Services, LLC FL State Certified Radon Mitigation Business #RB1 599 3361 5th Avenue SW Naples, FL 34117 239-340-0027 Gene Yacobacci FL State Certified Radon Mitigation Specialist #R1598 FL State Certified General Contractor #CGC1520422 FL State Certified AC Contractor #CAC1 816667 for all plastic molded fresh air intake vents Hood Calcium filled Polypropylene • Melting point: 3250 F+ • UV Inhibitor added Pipe Aluminum Collar - Styrene • Free Air 4" dia. = to square inches • Protective Grid Size 4"dia. = protective grid • stationary molded plastic louvers • quick, easy installation • plastic furnace fresh air Intakes come with a molded screen to help prevent birds and rodents from entering • durable weather resistant Molded for easy connection of pipe Side View B sq. Rear View Arium Pines Lake Apartments 7773 Pine Lakes Blvd. Port St. Lucie, FL 34952 Building # 1 M7 CHICAGO 2' 8 L I "ST E 0 E218111 Timer Instructions: Warning: 1. The Timer is designed for indoor use only. 2. Keep this product out of the hands of children. 3. Only plug the timer into a 125VAC electrical outlet. 4. Maximum Watts: 2,000 Watts (Do not exceed). 5. Keep Timer dry at all times. Do not plug in the Timer if hands or feet are wet. 6. Plug the one or two appliances into the Timer. Set the ON/OFF switch to ON. Plug the Timer into a 125VAC electrical outlet, and the Timer set-up is complete. Setting the ON/OFF function: Note the black time indicators behind the dial. Each time indicator represents 15 minutes. When setting the ONIOFF function, you have to push the appropriate time indicators down, away from the dial. Example: Setting the light to turn on at 8 P.M. and turn off at 6 A.M. All time indicators between 20 (8 P.M.) and 6 (6 A.M.) must be pushed down, away from the dial. When setting the time indicators. Note the RED ON/OFT switch on the side of the Timer. Pushing this switch upward will activate the timer. Push this switch downward to deactivate the Timer. Easy Read Dynameter Vacuum Gauge 1. Reads 0 — 4" W.C. 2. Non -toxic Fluid 3. Adjustable zero 4. Vinyl tube connects 5. Mounts On Wall of AC closet or other visible location Radon Mitigation Services, LLC FL State Certified Radon Mitigation Business #RB1599 3361 E�h Avenue SW Naples, FIL 34117 239-340-0027 Gene Yacobacci FL State Certified Radon Mitigation Specialist #R1 598 FL State Certified General Contractor #CGC1520422 FL State Certified AC Contractor #CAC1816667 Fan ON Arium Pines Lake Apartments 7773 Pine Lakes Blvd. Port St. Lucie, FIL 34952 Building # 1 M rx-1 New Receptacle Installed For Radon Fan Unit. Includes UL Listed Timer RV100 Fan Installed Above Drywall Ceiling Behind Access Panel By AC Contractor Fan = 40W 0.6A 14 / 2 OR 12/ 2 ROMEX TO PANEL BOX OR GENERAL Circuit Shall Have Adequate Capacity LIGHTING CIRCUIT To Support Additional Load 20A UL Listed Timer �' 1, -� ELECTRICAL PLANS 1 Receptacle — Ground Floor Unit PANEL BOX OR GENERAL LIGHTING CIRCUIT Mike Lang Electrical Cont. Arium Pines Lake Apartments 5408 San Roma Circle 7773 Pine Lakes Blvd. Lake Worth, FIL 33467 Port St. Lucie, FIL 34952 561-723-2895 Building # 1 Michael T. Lang FIL State Certified Electrical Contractor # ECO000227 Michael T. Lang El