Loading...
HomeMy WebLinkAboutDESIGN AND SPECIFICATIONSRADON MITIGATION SYSTEM DESIGN AND SPECIFICATIONS Owner: BIR Carroll St. Lucie, LLC 7700 Pine Lakes Blvd Port St. Lucie, FL 34952 SCA NIVA PROPERTY NAME = ARIUM PINE LAKES APARTMENTS &V S6 Job Address = 7755 Pine Lakes Blvd, Port St. Lucie, FIL 34952 (Building # 1) Contents E CUR MI = Radon Mitigation System Diagram (2 Bef M2 = Radon Mitigation System Diagram (Pr ofile) M3 = Radon Mitigation System Diagram — AC Return Closet Detail M4 = Ventilation Fan Specification M5 = Access Panel Specification M6 = Deco Grill Specification (Supply Grill) M7 = Outside Air Vent Hood Specification M8 = Timer & Manometer Specification El = Electrical Specifications Contractors Air Conditioning Contractor = Radon Mitigation Services, LLC 3361 5 1h Ave SW Naples, FL 34117 Gene Yacobacci CAC 1816667 SLLUCIE COMM 239-340-0027 PLM REVIEW Electrical Contractor Mike Lang Electrical Cont., Inc BU)G;.-� 5408 San Roma Circle DATE;.� Lake Worth, FL 33467 EUEC;j0j:-�-wV DATE;/ �7 Michael T. Lang ECO000227 PILULWL� 561-723-2895 GAIE7- -0 Applicable Codes FL Building Code 2014 FL Mechanical Code 2014 Electrical Code — NEC2014 O/A Supply To AC Return - Deoo Grill Installed In Ceiling Imme-1. Room 1 3r X 1�6r PA110; 13" x 41 E loy 3 4-Inch Thermo Fin Metal Duct Routes Above Drywall Ceiling THE VENTILATION FAN IS INSTALLED ABOVE THE DRYWALL CEILING IN THE BEDROOM CLOSET A 14" X 14" ACCESS PANEL IS INSTALLED IN THE CEILING ELECTRICAL— INSTALL RECEPTACLE& UL LISTED TIMER I DISCONNECT AT ACCESS PANEL LOCATION. Power From General Lighting Circuit. SEE El I All Wall Penetrations Are Located Fresh Air Intake On Exterior Walls. No Hallway Or Vent I Breezeway Penetrations Two Bedroom I Two Bathroom 1,039 Sq. Ft. Radon Mitigation System Design Mechanical Ventilation Radon Mitigation Services, LLC Ariurn Pines Lake Apartments FL State Certified Radon Mitigation Business #RB1 599 7755 Pine Lakes Blvd. 3361 5 th Avenue SW Port St. Lucie, FL 34952 Naples, FL 34117 Building # 1 239-340-0027 Gene Yacobacci FL State Certified Radon Mitigation Specialist #R1598 FL State Certified General Contractor #CGC1520422 FL State Certified AC Contractor #CAC1816667 Gene Yacobacd M 1 System Failure Device U-Tube Manometer, Installed In Each AG Closet. Upper Floor Unit (S) No Access Required Radon Mitigation System Design Radon Mitigation Services, ILLC FL State Certified Radon Mitigation Business #RB1599 3361 5th Avenue SW Naples, FL 34117 239-340-0027 Gene Yacobacci FL State Certified Radon Mitigation Specialist #111598 FL State Certified General Contractor #CGC1520422 FL State Certified AC Contractor #CAC1 816667 Outside Air Intake Vent Hood Exterior Block wall Arium Pines Lake Apartments 7755 Pine Lakes Blvd. Port St. Lucie, Fl- 34952 Building # 1 M2 4-Inch Radon Duct 4-INCH DECO GRILL Fresh air Supply V I A i T.11k 111113 Z�l System Failure Device U-Tube Manometer Installed In Each AC Closet. WATER HEATER SUPPLY AIR DUCT Mechanical Closet Profile - Typical All Units Radon Mitigation Services, LLC FL State Certified Radon Mitigation Business #RB1599 3361 5th Avenue SW Naples, FL 34117 239-340-0027 Gene Yacobacci FL State Certified Radon Mitigation Specialist #R1 598 FL State Certified General Contractor #CGC1520422 FL State Certified AC Contractor #CAC1 816667 Arium Pines Lake Apartments 7755 Pine Lakes Blvd. Port St. Lucie, FIL 34952 Building # 1 M3� V -,,)ON FAN SPECIFICATIONS-- RADONAW" (SPRUCE) RV100 Designed specially for radon mitigation, RV Series Fans provide superb performance, use little electric power, run ultra quiet and are attractive. An ideal choice for most radon mitigation systems. Model selection is dependent on building characteristics and should be made by a radon professional. 9.51 *Typical monthly electric cost $1.00 - $2.00 depending on model, electric rates & operating conditions. 0 Maximum IF —Typical CIFMI vs; Static Pressure Fjo-, _s" Pressure F-10-0 I 5 - Year Warranty. Mounts on duct 4" diameter ducts. Rugged .125" Noryl plastic housing. Electrical box for hard wire or plug in. ETL Safety Agency Listed - tested to LIL Standard 507 for indoor or outdoor use. Meets all electrical code requirements. Size: 9.5H" x 8.5" Dia. Weight- 6 lbs. Continuous Duty / Thermally protected Class B Insulation 3000 RPM Rated for Indoor or Outdoor use ICONCRETE DECK I Fan Supported Using Factory Bracket Secured To Deck Using (3) 3/8 X 1 % Tap Cons I 10 a -N � A 0 4 . - a a W < N a 0 41 & - 4 4 /_ . DROP CEILING SPACE 12' TOOUTSIDEWALL RV100 FAN UNIT INSTALLED [FRE--;7AJR DISCHARGE 1 114'X14'A CESS I - IN DROP CEILING FDR);TALL ROPCEILING1 Radon Mitigation Services, LLC FIL State Certified Radon Mitigation Business #RB1 599 3361 5t� Avenue SW Naples, FIL 34117 239-340-0027 Gene Yacobacci FIL State Certified Radon Mitigation Specialist #R1 598 FIL State Certified General Contractor #CGC1520422 FIL State Ceffified AC Contractor #CAC1816667 Arium Pines Lake Apartments 7755 Pine Lakes Blvd. Port St. Lucie, FIL 34952 Building # 1 L 4700 W. 11GO' Cleveland, 0" ".S ACCESS ABLE" PH:800-321-9532 FX'aGM21-9535 ACCESS PANELS W.Daley.com TECHNICAL SPECIFICATION TECHNICAL SPECIFICATION: Oatey Access Able Access Panels are designed to allow access to service areas. Access Panels can be used for access to plumbing, electrical, security systems, telephone, computer cables, and sprinkler systems. Reversible feature allows for flush mounting or surface mounting. USPats7tF#489Q418&5355526. L PROPERIXES Material LIN. Stabilized ABS Color White DIRECTIONS FOR US& Surface Mount Installation: Out appropriate size opening using frame as a template. Check for level. Apply construction adhesive to backside of frame flange. Fit frame Into opening. Press flange against wall to ensure flat Installation. After adhesive Is set snap door Into place. Flush Mount Installation: Nall or screw frame Into place at desired location with flange flat against the stud. Check for level. Drywall or plaster to the top of the flange. Snap on door after wall covering Is complete. COMMON APPLICATIONS Daley Access Panels provide arr to service areas, while allowing an easy Installation Into wall surface. Patented dips on panel door and frame eliminate sagging or bowing of door In ceiling applications. PRODUCT ESCRIP77ON ActualDoorS[ze FrameSizeto Outer Flange Wall Opening PACK C I D I E 34OS6 1 140 x 140 Access Panel 1344" 1 1344" 1 17" Ir 140 114' 1 6 Data Is subject to manufacturing toleran� Radon Mitigation Services, LLC FL State Certified Radon Mitigation Business #RB1 599 33615 th Avenue SW Naples, FL 34117 239-340-0027 Gene Yacobacci FL State Certified Radon Mitigation Specialist #R1 598 FL State Certified General Contractor #CGC1520422 FL State Certified AC Contractor #CAC1 816667 Arium Pines Lake Apartments 7755 Pine Lakes Blvd. Port St. Lucie, FL 34952 Building # 1 M5 PRODUCT SPECIFICATIONS and TECH N I CAL SaIdes- Deco Grille DATA 0810 jAMIEEFUC�^N @aides Vr=N-r 4521 1 Gth Street Court E., Suite 104, Bradenton, FL 34203 USA Phone: 941-351-34411 Fax: 241-351-3442 wwmarnericanaldes.com 1 E-mail: info@aldes-us.com Part# Size Description A B C D 22073 3" WHITE PLASTIC CABS) GRILLE 3" 4-3/4" I/Z. 5/8., 22 a72 N WHITE PLASTIC (ABS) G R1 LLE 1 4" 1 5-3/4" 1 11116" 1 V 22 d78 WHITE PLASTIC (ABS) GRILLE 1 5- 1 5-1/2" 1 519' 1 141N3 Radon Mitigation Services, LLC FL State Certified Radon Mitigation Business #RB1599 33615 th Avenue SW Naples, FIL 34117 239-340-0027 Gene Yacobacci FL State Certified Radon Mitigation Specialist #R1 598 FL State Certified General Contractor #CGC1520422 FL State Certified AC Contractor #CAC1 816667 Arium Pines Lake Apartments 7755 Pine Lakes Blvd. Port St. Lucie, FL 34952 Building # 1 Part# Size Description A B C D 22073 3" WHITE PLASTIC CABS) GRILLE 3" 4-3/4" I/Z. 5/8., 22 a72 N WHITE PLASTIC (ABS) G R1 LLE 1 4" 1 5-3/4" 1 11116" 1 V 22 d78 WHITE PLASTIC (ABS) GRILLE 1 5- 1 5-1/2" 1 519' 1 141N3 Radon Mitigation Services, LLC FL State Certified Radon Mitigation Business #RB1599 33615 th Avenue SW Naples, FIL 34117 239-340-0027 Gene Yacobacci FL State Certified Radon Mitigation Specialist #R1 598 FL State Certified General Contractor #CGC1520422 FL State Certified AC Contractor #CAC1 816667 Arium Pines Lake Apartments 7755 Pine Lakes Blvd. Port St. Lucie, FL 34952 Building # 1 ,jdaleio�tlmd �� �wa,,-- Technical Product Fresh Air Intake Vent mirith molded plastic grid HSM4W,HSM4B (CD Plastic collar (SVIVIAW4 Only) Model No. A B C HSIV14W 6' 5'1-' 4' HSM4B 6' Vh' 4" SV W4 6' 5W 4' fiff I A SVMAW4 SVMAW4 only) Radon Mitigation Services, LLC FL State Certified Radon Mitigation Business #RB1 599 3361 5 th Avenue SW Naples, FL 34117 239-340-0027 Gene Yacobacci FL State Certified Radon Mitigation Specialist #R1598 FL State Certified General Contractor #CGC1520422 FIL State Certified AC Contractor #CAC1816667 Model No. Description I Color SVMAW4 Hood/pipe/collarassem.1 White For all plastic molded fresh air intake vents Hood Calcium filled Polypropylene • Melting point: 3250 F+ • UV Inhibitor added Pipe Aluminum Collar - Styrene • Free Air 4" dia. = to square inches • Protective Grid Size 4"dia. = protective grid • stationary molded plastic louvers • quick, easy installation • plastic furnace fresh air intakes come with a molded screen to help prevent birds and rodents from entering • durable weather resistant Molded for easy connection of pipe Side View R sq. Rear View Arium Pines Lake Apartments 7755 Pine Lakes Blvd. Port St. Lucie, FL 34952 Building # 1 M7 CHI GO Timer Instructions: Warning: 1. The Timer is designed for indoor use only. 2. Keep this product out of the hands of children. 3. Only plug the timer into a 125VAC electrical outlet. 4. Maximum Wafts: 2,000 Watts (Do not exceed). 5. Keep Timer dry at all times. Do not plug in the Timer if hands or feet are wet. 6. Plug the one or two appliances into the Timer. Set the ON/OFF switch to ON. Plug the Timer into a 125VAC electrical outlet and the Timer set-up is complete. Setting the ON/OFF function: Note the black time indicators behind the dial. Each time indicator represents 15 minutes. When setting the ONIOFF function, you have to push the appropriate time indicators down, away from the dial. Example: Setting the light to turn on at 8 P.M. and turn off at 6 A.M. All time indicators between 20 (8 P.M.) and 6 (6 A.M.) must be pushed down, away from the dial. When setting the time indicators. Note the RED ON/Off switch on the side of the Timer. Pushing this switch upward will activate the timer. Push this switch downward to deactivate the Timer. 7, Easy Read Dynameter Vacuum Gauge 1. Reads 0 — 4" W.C. 2. Non -toxic Fluid 3. Adjustable zero 4. Vinyl tube connects 5. Mounts On Wall of AC closet or other visible location Radon Mitigation Services, LLC FL State Certified Radon Mitigation Business #RB1 599 33615 th Avenue SW Naples, FL 34117 239-340-0027 Gene Yacobaccl FL State Certified Radon Mitigation Specialist #R1 598 FL State Certified General Contractor #CGC1520422 FL State Certified AC Contractor #CAC1 816667 Fan ON Arium Pines Lake Apartments 7755 Pine Lakes Blvd. Port St. Lucie, FL 34952 Building # 1 M R-9 New Receptacle Installed For Radon Fan Unit. Includes UL Listed Timer RV100 Fan Installed Above Drywall Ceiling Behind Access Panel By AC Contractor Fan = 40W 0.6A 14 / 2 OR 12/ 2 ROMEX TO PANEL BOX OR GENERAL Circuit Shall Have Adequate Capacity LIGHTING CIRCUIT To Support Additional Load 20A UL Listed Timer ELECTRICAL PLANS 1 Receptacle — Ground Floor Unit PANEL BOX OR GENERAL LIGHTING CIRCUIT Mike Lang Electrical Cont. Arium Pines Lake Apartments 5408 San Roma Circle 7755 Pine Lakes Blvd. Lake Worth, FL 33467 Port St. Lucie, Fl- 34952 561-723-2895 Building # 1 Michael T. Lang i� FL State Cerfified Electrical Contractor # ECO000227 & Michael T. Lang El