HomeMy WebLinkAboutROOF INFORMATIONTo:�, Page'4 of 10 2017-06-06 13:39:48 (GMT) !:rom: Elaine Newnum - Advanced Commerical R I REC.EIVEI) 8503 US Hwy 1 Ste. 9 Port St. Lucie, FL 34952 GUIDE SPEC WE-1P-EX SEP 0, 6 41M 411117 White Elastomeric PERMITTING SCANNED 11441POECounty, FL BY I Ply Polyfiber Membrane Rcv-071317 St. Lucie County Over Existing roof surface IM6 C44-6S1A0i3O*b . Plastic roof cements, mechanical fasteners. walk ways; as supplied by others. 20 Ye . ar 5 vtja��i Part 3— Application 3.01 Preparation Replace any rotten or damaged substrate and build up with insulation level with surrounding roof. Clean surface prior to commencement of roofing application. Insure surface is dry prior to application and that is has proper drainage necessary to meet NRCA recommenclations. 3.02 Insulation Installation in repaired areas Description . Cold process built up roofing - Consists of a property prepared existing roof surface followed covered vvith a ply of Flexbond polyflber membrane, embedded in layers of Flexbond mastic and a final surfacing of White Elastomeric coating. Part 11— General Requirements • Substrate must be dry and free of loose debris. • Roof area must have adequate drainage as per NRCA guidelines. z • Airless spray equipment recommended. Part 2— Products 2.01 Acceptable Products G Materials manufactured, supplied or approved by � 2S Advantage Systems Marketing. 2.02 Product Delivery F3 Bulk delivery materials shall be by a authorized des of Advantage Systems Marketing. 2.03 Materials 'Es • Ply Sheets Flexbond polyfiber membrane 44 • Inter -ply adhesive . Flexbond modified asphalt mastic I Surfacing ASM apEroved White Elastorneric coating (oil base2fpla-�- PLANS AIND ALL PROPOSED VIORK Miscellaneous ARE SUH-=T TO ANY CURECTIONS RrC'UIRED By FIELD INSPECTORS THAT MAY SE NECESSARY IN 019DER TO COiMPLY VVITH ALL APPLIG14Ue CODES. Install the selected insulation over the exposed decking in a manner so as to break the joints by staggering the insulation by 50% of it's length. i.e. when installing 8'sheets cut the first sheet of the second course in half making a 4' x 4'starting piece. Over metal decking install an compatible insulation board with a minimum thickness of 1.5". Base Installation over insulation (three options) 0. Adhered Adhere by applying a layer of Flexbond modified asphalt mastic as a tack coat at a rate of approx. 2 gallons per square. Mechanically fastened Mechanically fasten the lapped edge 12' o.c. and in the middle of the field at 24" o.c. Adhered and mechanically fastened Apply a tack coat of Flexbond modified asphalt mastic at a rate of approx. 1-2 gallons per square. Mechanically fasten the lap edge 18" o.c covering the fasteners with the next strip of base sheet. BUILDING DIVISION REVIEWED POR COMPLIANCE REVIEWED BY DATE PLANS AND PERMIT MUST BE KEPT ON JOB OR No INSPECTION WILL BE MADE To:', Pa9615 of 10 2017-09-06 13:39:48 (GMT) From: Elaine Newnum - Advanced Commerical R 8503 US Hwy I Ste. 9 Port St. Lucie, FL 34952 GUIDE SPEC WE-1 P-EX(cont.) White Elastomeric Surface 1 Ply Polyfiber Membrane Over Existing roof surface Rev-071317 4:' overlap. Continue the roof membrane up onto 1.0 ve . ai Ill S vi? a ; r Iabo , T".' walls and penetrations 1-2', trimming off excess. Hand brush polyfiber on walls and penetrations to insure good adhesion and to remove any voids or wrinkles. Flashing (penetration) Milo Apply a layer of plastic cement around roof penetration being flashed. Coat the plastic cement with Flexbond FILt uupy modified asphalt mastic, brushing to remove excess mastic. 3.02 Base Installation (cont.) Embed a layer of Flexbond polyfiber General flashing membrane into the mastic. Hand brush the polyfiber into mastic to • Base sheet laps to be either parallel to remove air voids and wrinkles and to the flow of water or with a positive lap insure that the polyfiber contacts where laps shed the flow of water. mastic and starts the absorption • Walls must be adhered and process. mechanically fastened. Apply a layer of Flexbond modified Reinforce comers with plastic cement asphalt mastic over the exposed applied under and over base sheet 6'In polyfiber, brushing to remove excess. all directions Flashing (wall) Smooth out minor plane change Apply a minimum 3" wide strip of irregularities (greater than 1/4" and up plastic cement along anticipated top to 3/4") with plastic cement. termination point of the Flexbond Smooth out larger plane change polyfiber flashing membrane. irregularities (greater than 314") with Coat the plastic cement and the wall either wood, metal or insulation. with Flexbond modified asphalt mastic, 3.03 Membrane Installation brushing to remove excess. Mastic (base coat) Lmbed a layer of Flexbond polyfiber flashing membrane into the mastic. Adhere by applying a layer of Flexbond modified asphalt mastic at a rate of Hand brush the polyfiber into mastic to approx. 4 gallons per square. remove air voids and wrinkles and to insure that the polyfiber contacts mastic and starts the absorption Polyfiber process Install a layer of Flexbond polyliber —membrane into the wet mastic. Broom the polyliber with a medium stiff bristle push broom into mastic to remove air voids and insure that the polyfiber contacts mastic and starts the absorption process. End and side laps to have a minimum To:', Page,6 of to 2017-09-06 13:39:48 (GMT) From: Elaine Newn.um - Advanced Commerical R 8503 US Hwy I Ste. 9 Port St. Lucie, FL 34952 GUIDE SPEC WE-1 P-EX (cont.) jgrgmg�u gg VM Rev-071317 ;i67,mii Appika 6itirn Rate:' 3.03 Membrane Installation (cont). 6 Mastic (top coat) . General Apply a layer of Flexbond modified asphalt mastic to the field of the membrane at a rate of approx. 4 gallons per square. The intent is to saturate the polyfiber with the mastic. When applying mastic.to walls the excess should be removed in order to avoid 'slumping". The coated wall should be brusher from top to bottom in a downward motion. Top coat of mastic must be applied in such a way as to allow the worker to bark off tire roof without having to walk thru the finished layer of mastic. Allow mastic to cure approx. 60-90 days before walking on the mastic. Walkway may be installed over the top layer of mastic immediately after application. The walkway will adhere to the roof and should be left in place, therefore install the walkway with great care giving consideration to the appearance as will as the functionality. When coating around penetrations or -protrusions, care should be taken to insure that all sides are coated, avoiding unseen areas being missed. 3.04 White Elastomeric Coating Application Gray Coat A layer of ASM approved oil based White Elastomeric coating is to be White Elastomeric Surface 1 Ply Polyfiber Membrane Over Existing roof surface applied at an approx. rate of .75 gallons per square with the intent of covering the mastic completely. It should be noted that this first coat will be somewhat inconsistent In color due to the fact that some areas will have a heavier coating than specified. Even though the first Goat is the same color as the top coat, the black asphalt mastic will show thru this coat, this is why this first coat is referred to as the 'Gray" coat. . White Coat 0 General A layer of ASM approved oil based White Elastomeric coating is to be applied at an approx. rate of .75 gallons per square with the intent of covering the gray Goat completely. It is expected that this final coat will be consistent in it's appearance. Equipment and/or other items should be cleaned as soon as practical using an oil based solvent, preferably mineral spirits. Job Specific Information Customer - Project Name- Address- City/State- Warranty- 20 yr. material 5 yr. labor Start clate- Applicable Product Approval Codes - FL 15654-112 NOAIS-0616.04 ASTM D6083 FL 11475.1 FL 12974.1 NOA14-0401.03 Installer- Advanced Commercial Roofing Licenses- C151460S, 104-00046460, 0004692,CCCO57594 Product Approval CONTRACTOR-, Advanced Commercial Roofing ADDRESS: 8503 US Hwy 1 Ste. 9 Port St. Lucie. IPERMIT No. Rodua type Need Model Number Need Manufacturer thitpao Nhr- lmpa�t Design pre.u. Florida Product approval Code Miami Dade NOA # Code Edition Polyfiber DuraSpun 033MBO Johns Manville N/Al-367.5 FL 11475.1 ASTM D 6878 2014 Walkway (SBS) Firestone SBS White Granulated Firestone Building Products FL 984.1 2014 Elastomeric Roof Coaling Lucas 96000 Elastomeric R.M. Lucas Co. FL 15654.1 14-051101 2014 Roof Cement Lucas #779 All Weather Cement R.M. Lucas Co. FL 15654.2 2014 Modified Asphalt Mastic Parma Mop Owens Coming Fl- 12874.1 .14-0401.03 2014 PAPER COPIES OF THE PRODUCT APPROVALS AND 11,1STALLATION INSTRUCTIONS MUST BE PROVIDED ON SITE AT THE TIME OF INSPECTION lihtd Mein he. Ieeh evelu,ifedl., ampli,trice With the Florida Building ewe in accordant,awihit Ith. phtiii.l.phival rehit.mants fffi. FI.nd.SWt,, Slatut. Cl 553 S42 nd the rl.ridaAd.i.it,thitte, Cott. Clhapteirr)N-3. 0 0 0 . 0 . Zito .,Iry V11;