Loading...
HomeMy WebLinkAboutPLANS 261 AMEMCANTOWERO ATC TOWER SERVICES, LLC 3500 REGENCY PARKWAY SUITE 100 CARY, NC 27518 PHONE: (919) 468-0112 COA: 9053 5080 = RELAY TOWER, FLORIDA 200 FT GUYED TOWER MODIFICATIONS AS -BUILT SIGN -OFF OESCRIPnm SIGNATURE DATE CONTRACTOR NAME CONTRACTOR REPRESENTATIVE (PRINT NANIE) CONTRACTOR REPRESENTATIVE (SIGNATURE) REDEVELOPMENT PAt (PRINT NAME) IFIEDEVELCPAONr PJ& (SIGNATURE) PROJECT SUMMARY ATC PROJECT NUMBER_ OAA697703C6_08 CUSTOMER: AT&T MOBILITY CUSTOMER SITE NAME: RIVER PARK z CUSTOMER SITE NUMBER- WA 1480 DYER ROAD SITE ADDRESS: PORT SAINT LUCIE, FL 34952 DATE: 06122117 GEOGRAPHIC COORDINATES: 27.324500 -80.311200 PROJECT DESCRIPTION I SHEET THE MODIFICATIONS PRESENTED ON THESE DRAWINGS ARE BASED ON THE RECOMMENDATIONS OUTLINED IN THE STRUCTURAL ANALYSIS CONIPLETED UNDER ENGINEERING PROJECT NUMBER OAA697703 C3 05 DATED 05112117. SATISFACTORY compLEnoN 6F -ffiE WORK INDICATED ON THESE DRAWINGS WILL RESULT IN THE STRUCTURE MEETING THE REQUIREMENTS OF THE SPECIFICATIONS UNDER WHICH THE STRUCTURAL WAS COMPLETED. I Poo I I a WL10161 Mmy SCANNED BY SL Lude coar*y #%unoo 9ionj -Is A13 G3NNVOS THECSE PLANS AND ALL PROPOSED ViORK .z ARE SUBJECT TO ANY CORRECTIONS , .REQUIRED BY FIELD INSPECTORS THAT. !05. MAY 8 C- N EC ES CA RY- I M 0 R D E R TO. COMPLY WIT H I'll. APPL1=11 CODES' SHEET TITLE B-1 BILL OF MATERIALS IGN IBC GENERAL NOTES sic SPECIAL INSPECTION CHECKLIST A-1 MODIFICATION PRORLE A-2 DIAGONAL INSTALLATION DETAILS A-3 GUY WIRE TENSION CHART GUY WIRE RETENSIONING AND STANDARD SAFETY' F_j MODIFICATION FABRICATION DETAILS DETAILS :4 WA 0 0 0 0 0 0 0 AL A%M ATC TOWER SERVICES, UjC 35DDIMGENCYPARMAY SUITE 100 CARV. NC 27518 PHOPM(919)46MI2 COA: 9053 DESCRIPMON BY DATE RRST ISSUE DRV OGr22n7 A ATCSrTrNU&lHER: 6080 ATC SITE NAME -- RELAY TOWER FLORIDA SITEADDREW. 1480 DYER RGAD PORTSAINTLUCIE.FL349W K - E N No. 77258 STATE F DRAWN Br. I3RV(rEP) APPROVED BY.] OATEDRAWN: ITIM ATC JOB 140, 1 OAA6WMG_CS_0S COVER SHEET NUMBEFt REVISION: COVER 0 GENERAL 1. ALL WORICTO BE COMPLETED PER APPLICABLE LOCAL. STATE, FEDERAL CODES AND ORDINANCES AND COMPLY YM H ATC MASTER SPECIFICATIONS FORWIRELESS TOWER SITES- THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING AND ABIDING BY ALL REQUIRED PERMITS 2- ALL WORK INDICATED ON THESE DRAWINGS SHALL BE PERFORMED BY QUALIFIED CONTRACTORS EXPERIENCED IN TOWER AND FOUNDATION CONSTRUCTION. 13. THE CONTRACTOR SHALL NOTIFY THE ENGINEER OF RECORD IMMEDIATELY OF ANY INSTALLATION INTERFERENCE& ALL NEW WORK SHALL ACCOMMODATE EXISTING CONDITIONS. DETAILSNOT SPECIFICALLY SHOWN ON THE DRAWINGS SHALL FOLLOW SIMILAR DETAILS FOR THIS JOB. 4. ANY SUBSTITUTIONS SHALL CONFORM TO THE REQUIREMENTS OF THESE NOTES AND SPECIFICATIONS. AND SHOULD BE SIMILAR TO THOSE SHOWN- ALL SUBSTITUTIONS SHALL BE SUBMITI ED TO THE ENGINEER OF RECORD FOR REVIEW AND APPROVAL PRIOR TO FABRICATION. S. ANY MANUFACTURED DESIGN ELEMENTS SHALL CONFORM TO THE REQUIREMENTS OF THESE NOTES AND SPECIFICATIONS AND SHOULD BE SIMILAR TO THOSE SHOWN - THESE DESIGN ELEMENTS MUST BE STAMPED BY AN ENGINEER PROFESSIONALLY REGISTERED IN THE STATE OF THE PROJECT, AND SUBMITTED TO THE ENGINEER OF RECORD FOR APPROVAL PRIOR TO FABRICATION. 6. ALL WORK SHALL BE DONE IN ACCORDANCE WITH LOCAL CODES AND OSHA SAFETY REGULATIONS. 7- THE CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND EXECUTION OF ALL MISCELLANEOUS SHORING, BRACING, TEMPORARY SUPPORTS. ETC- NECESSARY. PER TIA-1019 A-201 1. TO PROVIDE A COMPLETE AND STABLE STRUCTURE AS SHOWN ON THESE DRAWINGS. S. CONTRACTORS PROPOSED INSTALLATION SHALL NOT INTERFERE, NOR DENY ACCESS TO. ANY EXISTING OPERATIONAL AND SAFETY EQUIPMENT- STRUCTURALSTEEL I - ALL DETAILING. FABRICATION AND ERECTION OF STRUCTURAL STEEL SHALL CONFORM TO THE AISC SPECIFICATIONS, LATEST EDITION- Z ALL EXPOSED STRUCTURAL STEEL MEMBERS SHALL BE HOT -DIPPED GALVANIZED AFrERFABRICATIONPERASIMA123. EXPOSED STEEL HARDWARE AND ANCHOR BOLTS SHALL BE GALVANIZED PER ASTM A163 OR B695. 3. ALL U43OLTS SHALL BE ASIM A36 OR EQUIVALENT, WITH LOOKING DEVICE. UNLESS NOTED OTHERWISE 4- FIELD CUT EDGES. EXCEPT DRIUrD HOLES. SHALL BE GROUND SMOOTH. 5- ALL FIELD CUT SURFACES. FIELD DRILLED HOLES & GROUND SURFACES WHERE EXISTING PAINT OR GALVANIZATION REMOVAL WAS REQUIRED SHALL BE REPAIRED WITH (2) BRUSHED COATS OF ZRC GALVILITE COLD GALVANIZ]NG COMPOUND PER ASTM A780 AND MANUFACTURERS RECOMMENDATIONS. 6. ALL STRUCTURAL STEEL EMBEDDED IN THE CONCRETE SHALL BE APPLIED WITH (2) BRUSHED COATS OF POLYGUARD CA-14 MASTIC OR EQUIVALENT. REFER TO THE MANUFACTURER SPECIFICATIONS FOR SURFACE PREPARATION AND APPUCATIONL APPLICATION OF POLYGUARD 400 WRAP IS NOT ESSENTIAL 7. CONTRACTOR SHALL PERFORM WORK ON ONLY ONE (1) TOWER FACE AND REPLACMEINFORGE ONE (1) BOLTIMEMBER AT A TIME 8. ALL FIELD DRII LFn HOLES TO BE USED FOR FIELD BOLTING INSTALLATION SHALL BE STANDARD HOLES. AS DEFINED BY AISC. UNLESS NOTED OTHERWISE. .A I 11 MAXIMUM ALLOWABLE ANGLE CLIP 11 - - - - - - - - - --- AREAOFANGLE TO BE CUPPED 1.5XL MAX PAINT 1. AS REQUIRED. CLEAN AND PAINT PROPOSED STEEL ACCORDING TO FAAADVISORY CIRCULAR AC 7017460-IK WELDING 1- ALLWELDING TO BE PERFORMED BYAWS CERTIFIED WELDERS AND CONDUCTED IN ACCORDANCE WITH THE LATESTEDITION OF THEAWS WELDING CODE DI.I. Z ALL WELDS SHALL HE INSPECTED VISUALLY. IF DIRECTED BY ENGINEER OF RECORD. 25% OF WELDS SHALL BE INSPECTED WITH DYE PENETRANT OR MAGNETIC PARTICLE (1000% IF REJECTABLE DEFECTS ARE FOUND) TO MEEIFTHE ACCEPTANCE CRITERIA OFAWS DI.l. REPAIR ALL WELDS AS NECESSARY. 3- BYANAWS CERTIFIED WELD INSPECTOR- 4- ALL ELECTRODES TO BELOW HYDROGEN. MATCHING RI I FR MErAl- PER AWS Di.l. UNLESS NOTED GTHERVVISE- 5� ALL WELDING ON LATTICE TOWERS STRUCTURES SHALL BEDONEWITt E70)D( ELECTRODES- ALL WELDING ON POLE JNLESS NOTED OTHERWISE. Ii. PRIOR TO MELD WELDING GALVANIZED MATERIAL, CONTRACTOR SHALL GRIND OFF GALVANIZING Irr BEYOND ALL FIELD WELD SURFACES. AFrER WELD AND WELD INSPECTION IS COMPLETE. REPAIRALL GROUND AND WELDED SURFACES WITH 2RC GALVILrTE COLD GALVANIZING COMPOUND PERASTM A781 AND MANUFACTURERS RECOMMENDATIONS. BOLT TIGHTENING PROCEDURE 1. STRUCTURAL CONNECTIONS TO BEASSEMBLED AND INSPECTED IN ACCORDANCE WITH RCSC-2W4 (SPECIFICATIONS FOR STRUCTURAL JOINTS USING ASTM A325 OR ASTM A490 BOLTS.) 2 FLANGE BOLTS SHALL BE INSTALLED ANDTIGHTENED USING DIRECT TENSION INDICATING PEE) SQUIRTER WASHERS- On SQUIRTER WASHERS ARE TO BE INSTALLED AND ORIENTED MGHTENEO PER MANUFACTURER SPECIFICATIONS TO ACHIEVE DESIRED LEVEL OF BOLT PRE -TENSION. I IN LIEU OF USING DTI SQUIRTIER WASHERS. FLANGE BOLTS MAY BE TIGHTENED USING AISC I RCSC -TURN-OF-THE-NUT` METHOD, PENDING APPROVAL BY THE ENGINEER OF RECORD (EOR)- TIGHTEN FLANGE BOLTS USING THE CHART BELOW. APPLICABLE CODES AND STANDARDS 1. ANSWUL STRUCTURAL STANDARDS FOR STEELANTENNATOWERSAND ANTENNA SUPPORTING STRUCTURES, 222-G EDITIOAL 2 2012 INTERNATIONAL BUILDING CODE (FORSPECIAL INSPECTION REQUIREMENTS ONLY� 3. BUILDING CODE (2014) 4- ACI 318-. AMERICAN CONCRETE INSTITUTE. BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE. 31841. 5. CRSI: CONCRETE REINFORCING STEEL IMSTffUTF_MAh[UALOFSTANDARD PRACTICE, LATEST EDITION. 6. Al=. AMERICAN INSTITUTE OF STEEL CONSTRUCT[OAL MANUAL OFsTEEL CONSTRUCTION. LATEST EDMON. 7- AWS: AMERICAN WELDING SOCIETY DI-1. STRUCTURALINEUDING CODE� LATEST EDITION - SPECIAL INSPECTION 1. A QUALIFIED INDEPENDENT TESTING LABORATORY. EMPLOYED By THE OWNER. SHALL PERFORM INSPECTION AND TESTING IN AcroRDANcEwrrH ISO 2m. SECTION 1704 AS REQUIRED BY PROJECT SPECIFICATIONS FORTHE FOLLOWING a) STRUCTURAL WELDING (CONTINUOUS INSPECTION OFFIELD WELD ONLY) b) HIGH STRENGTH BOLTS (PERIODIC INSPECTION OFA32S EXTENSION FLANGE BOLTS TO BE TIGHTENED PER 9IMN-OF-THE-NUTMETHOD) 2. THE INSPECTION AGENCY SHALL SUBMIT INSPECTION AND TEST REPORTS To BOLT LENGTHS UP TO AND INCLUDING FOUR DIAMETERS THE BUILDING DEPARTMENT. THE ENGINEER OF RECORD. AND THE OWNER IN 11r BOLTS LJP70AND INCLUDING 2D INCH LENGTH -1/3 TURN BEYOND SNUG TIGHT ACCORDANCEWITH IBG201Z SECTION 1704. UNLESS THE FABRICATOR IS sw BOLTS UPTOAND INCUJDING2 S INCH LENGTH -143TURN BEYOND SNUGTIGHT APPROVED BY THE BUILDING OFFICIAL TO PERFORM SUCH WORKWITHOUT THE 3w BOLTS UPTOAND INCLUDING 3J) 94CH LENGTH +13TURN BEYOND SNUGT1GHT SPECIAL INSPECTION& 7Ar BOLTS UPTO AND DJCLL13M a5 INCH LENGTH +1)3TURN BEYOND SNUG TIGHT V BOLTS UPTO AND INCLUDING 4.0 INCH LENGTH -lfJ TURN BEYOND SNUG TIGHT 14T BOLTS IF TO AND INCLUDING 4.5 INCH LENGTH +IJ3 TURN BEYOND SNUG TIGHT IAW BOLTS UPTO AND INCLUDING 50 INCH LENGTH ASTURN BEYOND SNUG TIGHT 11AW BOLTS LIP TO AND MILUDING r5 INCH LENGTH +103 TURN BEYOND SNUGTIGHT I-10 BOLTS LIP TO AND INCLUDING 410 INCH LENGTH +1/3 TURN BEYOND SNUG TIGHT 1027 BOLTS2ZTO4.0INCHLENGFH SIT BOLTS Z75 70 52 INCH LENGTH 3w EXoLTsa25TO6.0INCHUENGTH 7fir BOLTS 3.75TO 7A 14CH LENGTH 1. BOLTS425TO&O "LENGTH IAT BOLTS 4.7570 92 INCH LENGTH I-lW BOLTS SM TO 10.0 INCH LENGTH I-W BOLTS 17570 11.0 04CH LENGTH 142P BOLTS 6.25TO 12 0 INCH LENGTH +12 TURN BEYOND SNUG TIGHT +lr2 TURN BEYOND SNUG TIGHT +112 TURN BEYOND SNUG TIGHT +12 TURN BEYOND SNUG TIGHT +lf2 TURN BEYOND SNUG MGHT +I)2TURNBEYONDSNIJGTIGHT 4- SPLICE BOLTS SUBJECTTO DIRECTTENSION SHALL BE INSrALUED AND TIGHTENED ASPER SECTION 82-1 OF THEAISCSPECIFICATION FOR STRUCTURAL JOINTS USING A325 OR A490 BOLTS. LOCATED IN THE AISC MANUAL OF STEEL CONSTRUCTION- THE INSTALLAT10N PROCEDURE IS PARAPHRASED AS FOLLOWS. FASTENERS SHALL BE INSTALLED IN PROPERLY ALIGNED HOLES AND TIGHTENED BY ONE OF THE METHODS DESCRIBED IN SUBSECTION 021 THROUGH 82A. 821 TURNlOF-NUT PRETENSIONING BOLTS SHALL BE INSTALLED IN ALL HOLES OFTRE CONNECTION AND BROUGHTTO A SNUG TIGHTCONDITION AS DEFINED IN SECTION B-1. UNTILALL THE BOLTS ARE SIMULTANEOUSLY SNUG TIGHTANDTHECONNECTION ISFULLYCOMPACTED. FOLLOWING THIS INITIAL OPERATION ALL BOLTS IN THE CONNECTION SHALL BETIGHTENED FURTHER BY THE APPLICABLEAMOUNT OF ROTATION SPECIFIED ABOVE. DURING THE TIGHTENING OPERATION THERE SHALL BE NO ROTATION OF THE PART NOTTURNED BY THE WRFNCH. TIGHTENING SHALL PROGRESS SYSTEMATICALLY- 5- ALL OTHER BOLTED CONNECTIONS SHALL BE BROUGHTTO A SNUG TIGHT CONDITION AS DEFINED IN SECnONS.10FTHESPECIFICATION- ALL BOLTHOLES SHALL BEALIGNED TO PERMIT INSERTION OF THE BOLTS WITHOUT UNDUE DAMAGETO THE THREADS. BOLTS SHALL BE PLACED IN ALL HOLES WITH WASHERS POSITIONED AS REQUIRED AND NUTSITHREADEDTO COMPLETE THE ASSEMBLY. COMPACTING THEJOINTTO THE SNUG -TIGHT' CONDITION SHALLPROGRESS SYSTEMATICALLY FROM THE MOST RIGID PART OFTHEJOKT. THE SNUG -TIGHTENED CONDITION IS THETIGHTNESS THAT IS ATTAINED WITH A FEW IMPACTS OFAN IMPACTVARENCH OR THE FULL EFFORT OF AN IRONWORKER USING AN OROINARYSPUD WRENCHTO BRING THE CONNECTED PLIES INTO FIRM CONTACT - A AM mme ATC TOVVM SFRVICES, LLC 3500 REGENCY PARKWAY SUITE1100 CARY, NC 27518 PHONE. (919)46BM12 COA- 9053 CC iZAR 1;;..A WY �-- �MD W�M�.COWRAUGR(S)� REV. DESCRIPTION BY DATE FiRsTISSUE DRV 09=17 A ATC SITE NUMBER 5080 ATC SITE NAME: RELAY TOWER FLORIDA SITE ADDRESS: 1480 DYER ROAD PORT SAINT LUCIE, FL 34952 i . %lillmill LA/V of Lu Z7.- FL DRAWN BY. DEW (TEP) APPROVED BY- AT?KCI DATEDRAWN: oarmi7 ATCJOBNO: OAA697M�-CELDB IBC GENERAL NOTES SHEET NUMBER REVISION: IGN 1 0 THE SPECIAL INSPECTION (81) PROCEDURE IS INTENDED TO CONF[RMTHATCONSTRUCnON AND IINSTALLATION MEETS ENGINEERING DESIGN. ATC PROCEDURES AND ATC STANDARD SPECIFICATIONS FORVORELESSTOWER SITES - TO ENSURE THATTHE REQUIREMENTS OF THE SI ARE MET. IT IS VITALTHATTHE GENERAL CONTRACTOR AND THE INSPECTOR BEGIN COMMUNICATING AND COORDINATING AS SOON ASA PO IS RECEIVED FROM AMERICAN TOWER L CORPORATION (ATC). IT IS EXPECTED THAT EACH PARTY WILL PROACTIVaY REACH OUTTO THE OTHER PARTY. IF CONTACT INFORMATION IS NOT KNOWN. CONTACT YOUR AMERICAN TOWER POINTOFCONTACT. SPECIAL INSPECTOR THE SPECIAL INSPECTOR IS REQUIRED TO CONTACT THE GENERAL CONTRACTOR AS SOON AS RECEIVING A PO FROM ATC- UPON RECEIVING A PO FROM ATC THE SPECIAL INSPECTOR AT A MINIMUM MUSP • REVIEW THE REQUIREMENTS OF THE SI CHECKLIST. • WORK WIT-ITHE GENERAL CONTRACTOR TO DEVELOP A SCHEDULE TO CONDUCT ON.SITE INSPECTIONS. INCLUDING FOUNDATION INSPECTIONS. • ANY CONCERNS WITH THE SCOPE OF WORK OR PROJECT COMMITMENT MUST 13E RELAYED TO THE ATC POINT OF CONTACT IMMEDIATELY. THE SPECLPLL INSPECTOR IS RESPONSIBLE FOR COLLECTING ALL GENERAL CONTRACTOR INSPECTION AND TEST REPORTS. REVIEWING THESE DOCUMENTS FOR ADHERENCE TO CONTRACT DOCUMENTS. CONDUC71NG THE IWFIEUD INSPECTIONS, AND SUBMITTING THE SI REPORT TO AMERICAN TOWER CORPORATION. THE GENERAL CONTRACTOR 13 REQUIRED TO CONTACT THE sl INSPECTOR AS SOON AS RECEIVING A PO FOR THE MODIFICATION INSTALLATION OR TURNKEY PROJECT TO. AT A MINIMUM: REVIEW THE REQUIREMENTS OF THE SI CHECKLIST, • WORK WITH THE SI TO DEVELOPA SCHEDULE TO CONDUCT OWSITE INSPECTIONS. INCLUDING FOUNDATION INSPECTIONS. • BETTER UNDERSTAND ALL INSPECTION AND TESTING REQUIREMENTS - THE GENERAL CONTRACTOR SHALL PERFORM AND RECORD THE TEST AND INSPECTION RESULTS IN ACCORDANCE WITH THE REQUIREMENTS OF THE SI CHECKLIST. SPECIAL INSPECTION CHECKLIST IRSPEcnom DocumEw DESCRIPTION INSPECTIONTESTING RESPONSIBILITY IN REVIEW REQUIRED INSPECTION FREQUENCY REQUIRED PRE CK DURING CX POST CX PERIODIC I CONTINUOUS DOCUMENTATION AND SITE VISIT CONDUCTED BY AN ATC APPROVED SPECIAL INSPECTOR AS REQUIRED BY ATC AND OTHER SPECIAL INSPECTION FIFi n WORK & REPORT AUTHORITIES HAVING JUPJSD[CnOhL INSPECTION PARAMETERS TO FOLLOW ATUS STANDARD SPECIFICATION FOR WIRELESS -w# SI TOWER SITES - ENGINEERING ASSEMBLY DRAWINGS GC SHALL SUBMIT DRAWINGS TO SI FOR INCLUSION IN St REPORT GC -#IF FABRICATED MATERIAL VEPJFICAT10N & INSPECTION MTR AND OR MELL CERTIFICATIONS FOR SUPPLIED MATERIALS GG SHALL SUPPLY SI WITH REPORTS TO BE INCLUDED IN St st REPORT WHEN REQUIRED BY ATC INSPECTION AND REPORT OFSTRUCTURAL WELDING PERFORMED DURING PROJECT COMPLETED BYA CAll AND INCLUDED CERTIFIED WELD INSPECTION WITHIN SI REPORT GC/TA VISUAL OBSERVATION AND APPROVAL OF FOUNDATION EXCAVATION. REBAR PLACEMENT. CASINGISHORINGIFORMING FOUNDATION INSPECTION & VEPJFlCAT10N PLACENENT.AND ANCHOR TEMPLATE AND ANCHOR PLACEMENT -TO BE SI APPROVED PRIOR TO CONCRETE POUR AND SI DOCUMENTED IN THE SI REPORT ANCHOR, ROCK ANCHOR OR HELICAL PULL-OUT TEST PULL TESTING OF INSTALLED ANCHORS TO BE COMPLETED AND DOCUMENTED IN SI REPORT GCITA CONCRETE MD(DESIGN. SLUMP TEST. CONPIUESSIVE TESTING. AND SAMPLE GATHERING TECHNIQUES ARE TO BE PROVIDED CONCRETE ZNSPECT10N & VERIFICATION FOR INCLUSION IN THE SI REPORT. SI SHALL VERIFY CONCRETE PLACEMENT AS REQUIRED BY THE DESIGN DOCUMENTS GCITA (INSPECTION FREQUENCY IS MARKED CONTINUOUS) DYWIDAG PLACEMENTIANCHOR BOLT EMBEDMENT- EPDXY(GROUT ANCHORfRAR EMBEDMENT. HOLE SIZF- EPDXVIGROUT TYPF- INSTALLATION TEMPERATURE AND INSTALLATION SHALL BE INSTALL VERIFIED BY THE SI AND INCLUDED IN THE 81 REPORT GCISI BASE PLATE GROUT INSPECTION & VERIMCAT10N BASE PLATE GROUTING TYPE AND PLACEMENT SHALL BE CONFIRMED BY THE St AND INCLUDED IN THE SI REPORT GCISI EXCAVATION. FILL. SLOPE. GRADE AND OTHER EARTHANORK REQUIREMENTS PER PLANS SHALL BE VERIFIED BY THE SI AND EARTHWORK INSPECT10N & VERIFICATION INCLUDED IN THE SI REPORT GCITA CONTRACTOR SHALL PROVIDEAN INDEPENDENTTHIRD PARTY CERTIFIED INSPECTION WHICH PROVIDES TEST RESULTS FOR COMPACTION VERIFICATION COMPACTION TEST OF SOILS IN PLACETO ASTM STANDARDS. GCITA GC SHALL PROVIDE DOCUMENTAT10N SHOWING THATTHE GROUNDING SYSTEM SHALL HAVE A MEASURED RESISTANCE TO GROUND TESTING & VERIFICATION THE GROUND OF NOT MORE THAN THE RECOMMENDED 10 OHMS. PER THE ATC CONSTRUCTION SPECIFICATION UNDER GC SECnON 2 15 THIS DOCUMENTATION MUST BE AN INDEPENDENT CERTIFICATION. 'ASUAL OBSERVATION AND APPROVAL OFSTEEL CONSTRUCTION TO BE PERFORMED BY THE SL INSPECTION TO INCLUDE STEEL CONSTRUCTION INSPECTION & VERIFICATION VERIFICATION OF NEW CONSTRUCTION OR MODIFICATION OF E)aSnNG CONSTRUCTION PER ENGINEERED PLANS. DETAILED SI VERIFICATION SHALL BE INCLUDED IN SI REPORT- OWSITE COLD GALVANIZING VERIFICAT10N SI SHALL VERIFY WTTH GC ALL COLD GALVANIZATION TYPE AND APPLICATION AND INCLUDE SUMMARY IN SI REPORT GC GUY WIRE TENSIONING & TOWER ALIGNMENT REPORT GC SHALL PROVIDE SI EVIDENCE OF PROPER GUY TENSIONING AND TOWER PLUMB PER PLANS. SI SHALL VERIFY AND GC INCLUDE PLUMB AND TENSION REPORTING IN SI REPORT. DRAWINGS WITH CONSTRUC TION RED -LINES GC SHALL SUBMITAS-BUILr DRAWINGS INDICATING ANY APPROVED CHANGES TO ENGINEERED PLANS TO SI FOR GC GG AS -BUILT APPROVAUREVIEW AND INCLUSION IN SI REPORT SI AS -BUILT DRAWINGS WITH INSPECTION RED-UNES (AS REQUIRED) SI SHALL SUBMIT-AS-BUILT'DRAWINGS INDICATING ANY APPROVED CHANGES TO ENGINEERED PLANS WlTHIN SI REPORT SI 'TIA INSPECTION SI SHALL COMPLETE TIA INSPECTION AND PROVIDE SEPARATE TIA INSPECTION DOCUMENTATION TO ATC cm 81 PHOTOGRAPHIC EVIDENCE OF SPECIAL INSPECTION. ON SITE REMEDIATION, AND ITEMS FAILING INSPECTION & REQUIRIP PHOTOGRAPHS FOLLOW UP TO BE INCLUDED WITHINTHE SI REPORT. COMPLETE PHOTO LOG IS TO BE SUBMITTED WITHIN SI REPORT. GCISI NOTE: SPECIAL INSPECTIONS ARE INTENDED TO BE A COLLA130RATIVE EFFORT BETWEEN GC AND SL WHENEVER POSSIBLE GG IS TO PROVIDE SI VITTH PHOTOGRAPHIC OR OTHER ACCEPTA13LE EVIDENCE OF PROPER INSTALLATION IF PERIODIC INSPECTION FREQUENCY IS ACCEPTABLE. THE GC AND 81 SHALL WORK TO COMPILE EVIDENCE OF PROPER CONSTRUCTION AND LIMIT THE NUMBER OF SI SITE VISITS REQUIRED. TABLE KEY: SI -ATGAPPROVED SPECIAL INSPECTOR CX - CONSTRUCTION GC - GENERAL CONTRACTOR CM - CONSTRUCTION MANAGER TA - 3RD PARTY TESTING AGENCY ATC - AMERICAN TOWER CORPORATION A Amw ATC TOWER SERVICES, LLC 3500 REGENCY PARKWAY SUITE 100 CARY.NC27518 PHONE.- (919)468-0112 CDA' 9053 W�� CWUPACMPIS)��AM REV. DESCRIPTION BY DATE DRV Dfir Z%---FRU—lSSUF 017 'A A ATCSITENUMBER: 5080 ATC SITE NAME. - RELAY TOWER FLORIDA SITE ADDRESS: 1480 DYER ROAD PORT SAINTLUCIF FL34952 IV N No. 77258 STATE Qr 0 DRAWN DRV (TEP) APPROVED BY: ATIKCI DATE DRAWN: 06rM17 ATC JOB NO: OAA69T703LCELD8 SPECIAL INSPECTION CHECKLIST SHEET NUMBER: REVISION: sic 1 0 PLUMB AND TENSION NOTES- 1- PLUMBANOTENSION TOWER UPON THE COMPLETION OF ANYOTHER REQUIRED STRUCTURAL MODIFICATIONS DETAILED IN THE MODIFICATION PACKAGE REFERTO GUYWIRE TENSION CHART FOR REQUIREDGUYWIRETENSIONVALUES- Fl-- 2OW [TOP OF STRUCTURE] 2- NOTIFYATC ENGIMEHRING PRIORTO RErENSIOMNG IF THE GUYANCHOR DROP, RISE OR RADIUS EXCEEDS 15 FrATANYGUYANCHOR LOCATION OR IFANY GUYWIRE S12E DIFFERS FROM THOSE STATED IN THESE DRAMIINGS- L A 3- RETENSIONING OF EXISTING GUYVARES SHALL BE PERFORMED ATATIMEWHEN THE WIND VELOCITY IS �,,ffiT-0M—ffYpOSEGJ 9 O�B[M PRO SECTION112 Iz— RETENSION EXISTING SW ENS GUY WINE LESS THAN 10 MPH AT GROUND LEVEL AND WITH NO ICE ON THE STRUCTURE AND THE GUY WIRES. EL: 185X 1 LT- - 10% BREAKING STRENGTH 4- PLUMB THE TOWERWHILE FIETENSIONING THE EXISTING GUYWIRES. THE HORIZONTAL DISTANCE El: JS0J(r BETWEEN THEVEIZTICAL CENTERLIKES ATANY TWO ELEVATIONS SHALL NOT EXCEED 0.25% OFTHE VERTICAL DISTANCE BETWEENTHE TWO ELEVATIONS (EXAMPLE. MOTTO EXCEED 0 6 INCHES FOR 20 FEETVERTIGAL DISTANCE). MOUNTIMAY REQUIRESUPPORr AND 5- THE TWIST BETWEEN ANY TWO ELEVATIONS SHALL NOT EXCEED 05 DEGREES IN in FEET. THEMAXIMUM SELTIONII RE-NIOUNTING DURING INSTALLATION. TWIST OVER THE STRUCTURE HEIGHTSHALL NOT EXCEEDS DEGREES. SEE NOTE BELOW. 6- SEEGUY WIRE RETENSTONING AND STANDARD SAFETY WIRE DEFAIWI SHEET FOR ACCEPTABLE GUY WIRE TERMINATION EXTENSION, IF REQUIRED - EL: 160ir INSTALLADDITIONAL DIAGONALS TO FORM BACK-TO43ACK DIAGONALS 7- INSTALLI REINSTALL THE GUY ANCHOR SAFETY WIRE AS SHOWN ON THEGUY WIRE RETENSIONING AND I2Ll3r4-Xl3WX3H6-I STANDARD SAFETY WIRE DE TAILS'SHEEr SECTION 10 FROM EL. 11400 TO ISDff. & FOR GUY WIRE REPLACEMENT. PROVIDE TEMPORARY GUYING TO SECURE TOWER. CONTRACTOR TO El- isailr SEESNEETA-21FOR ONLY REPLACE (1) GUYWIREATATIME INSTALLATION DETAILS. SECTIONS EL: 140.lr . . . . YTrRElON EE;MLG 3W ILS GUY WERE AT&TMOBHUTY PROPOSED EL.- 1400 1 LT. 10% BREAKING STRENGTH (4)02lrBAWGS (110-19'FIBERTRUKK SECTIONS INSTALLED BUNDLED D(IS77NO EL: 120ff RETENSION EXSYING 31r ENS GUY WINE ALONGSIDE 930STING COAX (TYP.) EL. 12WILT--10% BREAKING STRENGTH 0 %7 SECTION7 EL: 100ff x RETENSIONEXISTINGStl6*1ENSGUYINIRE xEL: qszTLF� —io% BffiEffiNTc--s-rpfEpiWii SECTION 6 CIJMBIAIC PEGS ON LEO EL: MIT NTH SAFETY CABLE 066606 000 SECTION 5 COAX DISTRIBUTION EL-- 6off PETENSION EXISTING lr-� ENS GUY WERE Elz 600 1 LT. = ID% BREAKING STRENGTH SECTION 4 EL40-(r fl+H4 RETEMSION EXISTING 117'EKS GUY WINE BECT10N 3 SECTION2 El� 10-Ir SECTIONI EL: 0-Ir FW. 4-,r [BOTTOM OF S11RUCTUREJ TOWER ELEVATION VIEW INNER GUY ANCHOR CHART A23MUTH ELEVATION I RADIUS 0 JSL 0.1y 14S(F C(sm iff 1 147 V OUTER GUYANCHORCHA917 AZIMUTH Ef�ATION RAU] 2! APM D 59jIr ff Cw liar STR CONTACTAMERICAN TOWER FIELD OPERATIONS WHEN EXISTING EQUIPMENTINTERFERES WITH INSTALLATION OF MODIFICATION& ONCE APPROVM EXISTING EQUIPMENTMAY BETENFORARLY MOVED DURING MSTALLATICN&FtER&TALLEDTOTHEOIUGHIALHEIGHT&LOr-ATIONSY CONTRACTOR POST COMPLETION OF MODIFICATIONS. A Am FEW ATC TOWER SERVICES, LLC 3500 REGENCY PARKWAY SUITE 100 CARY,KC27518 PHONE. (919)468�1)1112 COA-- 9m CONTRACTOW)� REV. DESCRIPTION BY DATE FIRST ISSUE DFZV osrzmT ATC SITE NUMBER 5080 ATC SITE NAME RELAY TOWER FLORIDA SITE ADDRESS' 1480 DYER ROAD FORT SAINT LUCIE. FIL 34952 K. A,, GEN No. 77258 STATE 0 R 0/i DRAWN Br. DRV (TIEP) APPROVED BY ATJKCI - DATEDRAWN: OaMI7 ATC JOB NOr OAAWTT03 C6 08 MODIFICATION PROFILE SHEErNUMBER REVISION. A-1 1 0 EXIS71NG TOWER BOLT lr-rOXTA325 W1 NLFr4.KW-FW Eft- (rYp-) STITCH BOLT IrZO X I 3W A325 Mll NUT4-KW-FW EA. ITYP-) [CONTRACTORTOPROVIDE SPACERS TO MATCH E)asnNG LEG THICIMESS-1 508G-2 DIAGONAL (TYP-) SEE SHEErF-1 FOR FABRICATION DETAILS - [AMBLE TO BE FIELD CUF AND 4DRU.ED- SEE DErAJL -B--] FIELD DRILL NEW IV16'0 HOLE IN EMSTING DIAGONAL TOACGOMMODATr NEW UZO BOLT (TYP-) 5080-3 GUSSET PLATE (ryp.) SEE SHEET F-1 FOR FABRICATION DETAILS - [PLATE TO BE FIELD DRII I ED. SEE DETAIL 'C' BOLT Ir-PDX I 3f4"A325 W1 NLFr-LKW+W EA. (rYP-) 9116-0 NOTE.. CONTRACTOR TO REMOVE AND PROPERLY D IS POS E E XISUN G MUM" -PANE L H 0 RMDNTALS FROM EL- 140'-O*tTO ISW-Ut EXIS77NG DMG01ML 5080-1 DIAGO: (ryp.) SEE SH F-I FOR FABPJCAT10N DETAJLS. [ANGLE TO BE FIELD CUT AND DRlIl -SEEDETAIL-W-1 PARTIAL ELEVATION VIEW SECTION 9 JEL: 14&-O"TO 15W-Ol DETAIL W FIELD CUT & DRILL DETAIL"B" FIELD CUT & DRILL DETAIL OC" FIELD DRILL DIAGONAL SEE SHEET F-1 FOR FABRICATION DETAILS- SlTrcH 13OLT lrZOXI 3/4'A325 jjECTION -XA7\_ WINUF4.KW-FwEA, TYPICAL DETAIL (TYP-) [GONTRACTORTO PROVIDE SPACERS TO MATCH E)asnNG LEGTHICKNESSI EQUALSPACE EQUALSPAGE 7fir DIAGONAL SEE SHEET F-I FOR EXISUNG D14&urvAL TCH BOLT S ION -13-13- QxI 34� A325 ECT \_ rWr7lTUT-LKW-FWEA- TYPICAL DETAIL M?-) JCONIRAGTOR TO PROVIDE SPACERS TO MATCH EKISTING LED THICINESS I I NAM A ATC TOVWM SMInCES, UC =0 REGENCY PARMAY SUITE 100 cAff, He "SIB PHONE (919)4SM12 COA. 9053 �CDNMAGTCRES)� REV. DESCRIPTION BY DATE A FIRST ISWE 06=7 —DRV A A A ATC SITE NUMBER 5080 ATC SITE NAME RELAY TOWER FLORIDA SITE ADDREW. 1480 DYER ROAD PORT SAINT LUCIE. FL 34&-Q '01iiiii" 4, 1/�, K. LA/v Z E N z No. 77258 STATE 0 0, 1 OR DRAVVN BY-- DRV (rEP) APPROVED BY- AVKCI DATE DRAWN: 0SW17 ATCJOBNO: QAA697M3 C6 08 DIAGONAL INSTALLATION DETAILS SHEErNUMBER: REVISION: A-,' 1 0 GUY WRE TENSION CHART FOR GUY ANCHOR "X' GUYWIREDATA MEASURED GUY WIRETENSION IN POUNDS GUY WIRE SIZE GUY ELEV. (Fr) GUY ANCHOR RADIUS (IFT) GUYANCHOR DROP z 0 2 z r- TENSION DELTA DUE iti Imp. (LBS/DEG) 0* F S*F 10* F 15* F 20*F 25'F 30'F 35'F 40'F 45'F 50*F SS'F 60*F 65*F 70*F 75*F 80*F 85*F 90'F 95*F 100'F 105*F I+/- Fr)FLEG LBS LBS LBS LBS LBS LBS LBS LBS LBS LBS LBS LBS LBS LBS LBS LBS LBS LBS LBS LBS LEIS LBS 5/8" EHS 1853 159.0 1.0 A 10% 16.70 5242 5159 5075 4992 4908 4825 4741 4658 4574 4491 4407 4324 4240 4156 4073 3989 3906 3822 3739 3655 3572 3488 5/8" EHS 185.3 159.0 1.0 A 10% 16.70 S242 5159 5075 4992 4908 4825 4741 4658 4574 4491 4i07 4324 4240 4156 4073 3989 3906 3922 3739 3655 3572. 3488 3/4" EIS 140.0 159.0 1.0 A 10% 29.70 8582 8434 8285 8137 7988 7840 7691 7543 7394 7246 7097 6949 6800 6651 6503 6354 6206 6057 5909 5760 S612 5463 3/4" EHS 120.0 159.0 1.0 A 10% 36.19 8002 7821 7640 7459 7278 7097 6916 6735 6554 6373 6192 6011 5830 5649 5"S 5287 S"06- �925 4744 4563 1 4382 1 4201 �/16"�EHHS M 150.0 2.0 A 10% 2222 4875 4760 464 4531 4417 4302 4188 4073 3958 3844 :1779 361c; :Irno 33EIS 3271 1 3156 3�42 2927 2812 2�98 Ess3 2 9 _1/2', S a 60�0 150.0 2.0 A 10% 21.74 3994 2 3;811;6 37 3663 3560 3451 3342 3234 3125 2799 igii L82!41 3.473612 1/2" EHS 40.0 150.0 2.0 A 10% 23.55 41 3 i i i877 67 375n 2921 q�IA 2 2748 1 1630 GUY VARE TENSION CHART FOR GUY ANCHOR "B" GUY WIRE DATA MEASURED GUY WIRE TENSION IN POUNDS GUY WIRE S12E GUY ELEV (Fr)* GUY ANCHOR RADIUS (IFT) GUYANCHOR DROP g Z 2 z r- TENSION DELTA DUE TO TEMP. (IBS/DEG) 0'F S*F 10* F IFF 20*F I 25*F 30*F 35'F I 40'F I 45'F 50*F 55*F 60'F 65*F 70'F 75'F 80*F 85*F I 90-F F9F 100*F 105'F (I/- FT)7LEG LBS LBS UIS UIS I UIS I LBS LBS UIS UIS LBS I LBS LBS LBS LBS LEIS LBS LBS LBS LBS 5/8" EHS 1853 157.0 -.1.0 B 10 % 16A6 5228 5145 S063 4981 4898 4816 4734 4652 4569 4487 4405 4322 4240 4158 4075 3993 3993 3911 3828 3746 3664 3582 3499 5/8" EHS 1953 157.0 -1.0 8 10 % 16AG 5228 5145 5063 4981 4898 4816 4734 4652 4569 4487 4405 4322 4240 4158 4075 3993 3993 3911 3828 3746 3664 3587 3499 3/4- BS 140.0 157.0 -1.0 B 10 % 2937 8562 8415 8269 8122 7975 7828 7681 7534 7387 7241 7094 6947 6800 6653 6506 63 - 59 6359 6213 6066 5919 5772 5625 5478 3/4- EHS 120.0 157.0 -1.0 B 10 % 35,86 7982 7802 7623 7444 7264 7085 6906 6727 6547 6368 6189 6009 5830 5651 5471 5292 - 5292 V33 5113 4933 4754 4575 4396 4216 9/16" EHS 95.0 149.0 0.0 B 10 % 2223 4970 4756 4641 4527 4413 4299 4185 4071 3957 3842 3728 3614 3500 3386 3272 3 158 3158 3043 2929 2815 2701 2587 2473 1/2" EFIS 60.0 149.0 0.0 B 10% 21.70 3992 3884 3775 3667 3558 3450 3341 3233 3124 3016 2907 2799 2690 2581 2473 2364 r 23,4 2756 2147 2039 1930 1822 1713 1/2" EH5 40.0 149.0 0.0 B .10% 23.S2 4201 3984 3866 3749 3631 3513 3396 3278 3160 3043 2925 2808 2690 2577 2455 2 2337 7 2220 2102. 1984 1867 1749 1631 GUY WIRE TENSION CHART FOR GUY ANCHOR "C" GUY WIRE DATA MEASURED GUY WIRE TENSION IN POUNDS GUY WIRE S12E GUYANCHOR DROP Zg Z :9 E TENSION DELTA DUE To TEMP. (LBS/DEG) G'F S*F 10*F 15'F 20*F 25*F 30*F 3S'F 40*F 45* F 50*F 55*F 60*F 65'F 70*F 75'F 80*F 85'F 90'F 95*F 200' F 105'F Fr) LBS 1.85 LBS LBS LBS UIS LBS LBS LBS LSS LBS LBS LBS LBS LBS LBS LBS LBS LBS LBS UIS 5/8" EHS 1853 157.0 1.0 C 10% 16A6 5228 5145 5063 4981 4898 4816 4734 4652 4569 4487 4405 4322 4240 4158 4075 3993 3911 3828 3746 3664 3592 3499 5/8" EHS 1853 157.0 1.0 C 10% 16A6 5228 5145 5063 4981 4898 4816 4734 4652 4569 4487 4405 4322 4240 4158 4075 3993 3911 3828 3746 3664 3582 3499 3/4" BS 140.0 157.0 1.0 C 10% 2937 8562 8415 8269 8122 7975 7828 7681 7534 7387 7241 7094 6947 6900 6653 6S06 6359 6213 6056 5919 5772 S625 5478 3/4- EHS 120.0 157.0 1.0 C 10% 35,86 7982 7802 7623 7444 7264 7085 6906 6727 6547 6368 6189 6009 5930 5651 5471 5292 5113 4933 4754 4575 4396 4216 9/16" EHS 95.0 147.0 1.0 c 10% 22.65 4859 4746 4633 4519 4406 4293 4180 4066 3953 3940 3727 3613 3500 3387 3273 3160 3047 2934 2820 2707 2594 2481 1/2" EHS 60.0 147.0 1.0 C 10% 21.62 3987 3879 3771 3663 3555 3447 3339 3230 3122 3014 2906 2798 2690 258'.2 27474 3 6 '52 2150 2041 1933 1825 1717 1/2" EHS 40.0 147.0 1.0 C 10% 23AS 4099 3981 3864 3747 3629 3512 3394 3277 3160 3042 2925 2807 2690�257"3 245S 2 38 2220 2103 1986 1868 17SI 1633 1. ±IG% FOR GUYS � I'DINMETER. OF THE INITIAL TENSIONS SPErAnED ON 1 THE UM DEVIATION FROM THE DESIGN INITIAL TENSIONS ARE: THIS TEMPERATURErrENSION CHART- 2- ±5% FOR GUYS � I'DIAMETER, OFTHE INITIAL TENSIONS SPECIFIED ON THIS TEMPERATUREn ENSION CHART. A AIM FEW ATC TOWER SERVICES, LLC 3500 REGENCY PARKWAY CARY. NC 2YS18 PHONE.- (919) 46M12 COA: 9M W��CDNTRACTGRJS)� REV. DESCRIPTION By DATE A FIRST ISSUE ORV 06rnn7 ATC SITE NUMBER:- 5080 ATC SITE NAME - RELAY TOWER FLORIDA SITE ADDRESS: 1480 DYER ROAD SAINT WCIE, FL 34952 K. kGENS,�, N 77258 o. STATE OF z R 0 DRAWN BY. DIZVUEP) APPROVED BY ATIKCI nATEoRAwN: ovam ATCJOBNO: OAA697703L.CGL08 GUY WIRE TENSION CHART SHEETNUMBER: A-3 I RE"os'ON' STANDARD GUY WIRE HARDWARE JAW & EYE TURNBUCKLE DEAD END DEALD END THIMBLE SHACKLE GUY WIRE VmBeestG�PuOG-6315 GRIP SLEEVE Vm BeesM E-6120 Vm Beest G� P60 G-5263 OR CmsbyCD HG-227 PREFORMEDO PREFORMEDS ORCmsby0G-4l4 OR CmdrQ r,2i30A LU Of SIZE U.T.S. W.L. SIZE PIN 0 SIZE SUE Tgnu, SIZE SIZE P9110 0 lrr ERB 26.9 K 135 K 718XIB Sff ir—r ir_p 5W HVY sw 314" ir c 91119'EHS 350 K 17.5 K 718XI8 3hr silo, 3w HVY 5w 3W 5ArEHS 424K 212 K I X 24 7Ar 5V w 3WHVY 3w 7fir 314r EHS 5113 K 292 K 1 114 X 24 1 Ur aw WC 11 HVY 31C 7fir OK 34,U K 1114X24 1118- 3W 31'r IIIHVY 3W 7Ar DEAD END GRIP GUYWIRE GUY WIRE 18GAGE GUYWIRE SM GWIRE SEE NOTE I GUY WIRE TAIL SEIZING WIRE INSTALLATION TYPICAL DETAIL SE17JNG WIRE INSTALLATION: INSTALL SHACKLE 118GAGE SEIZINGWIRE SEE NOTES 2 & 3 1. LAY ONE END OF THE SEONG WIRE IN THE GROOVE BETWEEN TWO STRANDS IN THE GUY WIRE AND WRAP THE OTHER END TIGHTLY OVER THE PORTION IN THE GROOVE 2 CONTINUE TWISTING WITH PLIERS TO TAKE UP SLACKAND TIGHTEN- WRAP SEJ7JNGWIRE AROUND GUY WIRE FORA WIDTH EQUAL TO THE GUY WIRE DIAMETER. 3. WRAP SEIZING WIRE TIGHTLYAGAINST SERVING. WINDING TWISTED WIRE INTO KNOT BEFORE CUTTING OFFENDS OF THE WIRE POUND KNOTSNUGLY AGAINST THE GUY WIRE- 5 THREADS. bimfl�1:11 INSTALL LONGER TURNBUCKLE 1 on f4 I. TO OBTAIN CORRECT GUY WINE TENSIONS. IT MAY BE NECESSARY TO REPLACE THE DEAkD END GRIP (PREFORM) OF SOME GUY WIRES DUE TO EXISTING OVER -CONTRACTED TURNBUCI(LES 2 IF EXISTING TURNBUCKLE IS ALREA13Y FULLY EXTENDED. THE COMBINATION OF SHACKLES AND A LONGER TURNBUCKLE AS SHOWN MAY BE USED TO PROVIDE REQUIRED ADJUSTMENT. ALTERNATIVELY. IF THE allSnNG GUY WIRE TAIL IS LONG ENOUGH. THE DEAD END GRIP (PREFORM) MAY BE REINSTALLED TO INCREASE THE OVERALL LENGTH OF THE GUY WIRE- 3. IF REMOVAL BE REUSED - GRIP (PREFORM) IS REQUIRED, IT CANNOT 4. IF EXISTING GUY WIRE GROUNDING IS REMOVED DURING MODIFICATION INSTALLATION. IT MUST BE RECONNECTED AFTER THE CONIPLEnON OF THE TOWER MODIFICATIONS- IF ORIGINAL GROUNDING IS BROKEN OR DAMAGED AND CANNOT BE RECONNECTED. GUY WIRE GROUNDING IS TO BE REPAIRED OR REPLACI=D- ALLOWED GUY WIRE TERMINATION MODIFICATION TO RETENSION GUY WIRES (2) WIRE ROPE CUPS, 318- THREAD SAFETY WIRE THROUGH ALL THIMBLES. TURNBUCKLE BODY AND JAW EN13S THEN FASTEN LOOP WITH (2) 3V WIRE ROPE CUPS - 3fir EHS SAFETY WIRE (15 IFT) TYPICAL SAFETY WIRE INSTALLATION DErA]L W/ SHACKLES INSTALL SHACKLE 5 THREADS. MINIMUM ANCHOR HEAD PLATE 3V EHS SAFETY WIRE (15 FT) x (2) WIRE ROPE CUPS. 3fir THREAD SAFETY WIRE THROUGH ALL THIMBLES. TURNBUCKLE BODY AND JAW ENDS THEN FASTEN LOOP WITH (2) 319- WIRE ROPE CUPS. TYPICAL SAFETY WIRE INSTALLATION DEMIL W/O SHACKLES AAARme AW TOWER SERVICES, LLC 3530 REGENCY PARKWAY SUITE 100 CARY,NC27S1S PHONRIPHR41584112 COA-' 9053 REV- DESCRIPTION By DATE RR&r ISSUE DRV 06T22117 A ATCSITENLINBER: 5080 ATC SITE NAME - RELAY TOWER FLORIDA SITEADDRESS: 14M DYER ROAD PORTSAINTWaF-FL34952 LqlV No. 77258 STATE 0 1p -0 DRAWN BY.6 DRV (TEP) APPROVED BY: ATIKCI nArEDRAwN: OUnI17 ATCJOBHO, OAA697M 06 08 GUY WIRE RETENSIONING AND STANDARD SAFETY WIRE DETAILS SHEETNUMBER: REVISION: A-4 1 0 3 3fEr 5080-3 GUSSET PLATE 2114' ------------------------------------------------------------ -------------------------------- 76' -E -------------------------------------------------------------------------------------------------------- 7Ar 5080-2 MID -PANEL HORIZONTAL 2114' --------------------------------------- --- ----------------------- ---------------------------------------------------------------------------------------------------------- A Ir 5080-1 MID-PANCL-H-ORIZONTAL 5080-3 PL 114"X 6 3/4' 0'-6 314r 1 3.29 3.4# g2�2 i L I 3W X 1 X47 X 3119' 2.§- 1 7.4# 7.8# 5080_1 L 1 314'X 1 3W X 3/16* T-6; 7.4# 7.8ff PART NO. I DESCRIPTION LENGTH NOTES BUKWT GALVWT MATERIAL: A36 FINISH: GALVANIZED HOLES: 91 WO A AM < ATC TOWER SERVICES, U-C d 35HI RMENCY PARKWAY SUITE 100 CARY.NC27510 PHOM (919)46"112 COA: Saw �COKTPACTOR(5)� ����OF� REV� DESGRIPTION BY DATE & IFIRST ISSUE DRV 06r22JI7 ATC SITE NUMBER: 5080 ATC SITE NAME RELAY TOWER FLORIDA SITEADDRIEW. 1480 DYER ROAD PORT SAINT LUCIF- FL 34952 L4A1 EN No. 77258 s TATE OF 0 ORID DRAWN BY: DRV frEP) !YROVED By: ATIKCI nATE DRAWN nsr22rl7 ATCJOBNO'. 0AA69T703LCSj08 MODIFICATION FABRICATION DETAILS LSHEErNUMBEER: REVIS101 : F-1 1 0 70 7 o �/O -5- FILE COPY COPY 7', Alii at&t RIVERPARK (FA 10016792) /6T, LACIF COUATY BUILDING DIVISION REVIEWED FOR COMPLIANCE r F L E 'EVIEWED By bATE q e� - 7�-!Y PLANSANDPERMIT/ MUST BE KEPT ON JOB OR No INSPECTION WILL BE MADE 1480 DYER RUAD PORT ST LUCIE, FL 34952 SCANNED BY 3rd & 4th CARRIER OVEshl:0 County LOCAL MAP PROPERTY SUMMARY PROJECT DESCRIPTION INDEX OF DRAWINGS FOI In 3414-501-0716-000-0 PROPERTY OWNER AMERICAN TOWER SYSTEMS. INC. P.O. BOX 723597 ATLANTA. GA 31139 LATITUDE 27.324510' N LONGITUDE 60.311232' W ZONING JURISDICTION ST LUCIE COUNTY I THE WIRF1 ESS COMMUNICATIONS FACILITY IS NOT INTENDED FOR HUMAN OCCUPANCY. 2. THIS FACILITY DOES NOT REQUIRE POTA13LE WATER AND WILL NOT PRODUCE ANY SEWAGE. 3. CONTRACTOR SHALL VERIFY ALL PLANS AND EXISTING DIMENSIONS AND CONDITIONS ON THE JOB SITE AND SHALL IMMEDIATELY NOTIFY THE ENGINEER IN WRITING OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE WORK OR BE RESPONSIBLE FOR SAME. 4. INSTALLATION OF NEW ANTENNA MOUNT (WILL CAUSE THE SITE TO BE OFF -AIR FOR APPROXIMATELY 3 TO 7 DAYS). 5. THE SCOPE OF WORK CONSISTS OF PROPOSING A WIRELESS INSTALLATION: REMOVAL OF (9) EXISTING ANTENNAS REMOVAL OF (3) EXISTING ANTENNA MCUNTS INSTALLATION OF (9) NEW ANTENNAS INSTALLATION OF (6) NEW RRUS (REMOTE RADIO UNITS) INSTALLATION OF (1) NEW SURGE SUPPRESSORS INSTALLATION OF (3) NEW ANTENNA MOUNTS SHT. NO. DESCRIPTION REV. NO. LI X xc" N PEI TI TITLE SHEEr 0 T2 GENERAL NOTES 0 C�j COMPOUND PLAN 0 C2 ELEVATION AND ANTENNA PLANS 0 C3 DETAILS 0 El DC ELECTRICAL DErAILS 0 E2 GROUNDING DErAJLS AND NOTES 0 — � rvp ': '�l 4, -- F "T I VICINITY MAP DESIGN CRITERIA CODE COMPLIANCE -Rj "A" st T -51n,01 FIA I'll I jfj IFI?1-1 YT"I- 7'A Vu j7p Z' z Z� DESIGN WIND SPEED: 160 MPH (ULTIMATE. 3-SECOND GUST) 124 MPH (NOMINAL. 3-SECOND GUST) EXPOSURE: C RISK CATEGORY: 11 OPEN SrRUCTURE ALL WORK AND MATERIALS SHALL BE PERFORMED AND INSTALLED IN ACCORDANCE WITH THE CURRENT EDITIONS OF THE FOLLOWING CODES AS ADOPTED BY THE LOCAL GOVERNING AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES. 1 . FLORIDA BUILDING CODE. 5th EDITION (2014). 2. NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) 70-11, NATIONAL. ELECTRICAL CODE, 2011 EDITION. 3 ASCE 7-10. 4' TLA-222-G WITH ADDENDUM 1 AND 2 APPLICABLE STANDARDS. 5. LIFE SAFETY CODE NFPA-101-2012. 6. FLORIDA FIRE PREVENTION CODE, 5th EDITION (2014). 7. AMERICAN INSTITUTE OF STEEL CONSTRUCI`ION (AISC) 360-10 AND 341-10. B. UNDERWRITERS LABORATORIES (U.L) APPROVED ELECTRICAL PRODUCTS. 9. LOCAL JURISDICTIONAL REQUIREMENTS. 10. CITY/CCUNTY ORDINANCES. REVIEWEE) FOR CO EJRE�VIFWt RF DESIGN VERIFICATION j lj�'� PLANq AND PERMIT MUST BE KEPT ON JOU DESIGN BASED ON RFDS ID# 1411242 REV 0.1 DATED 2/22/17. CONTRACTOR SHALL REQUEST CURRENT RFDS AND CURRENT WORKBOOK FROM MASTEC NETWORK SOLUTIONS CONSTRUCTION MANAGER PRIOR TO CONSTRUCTION NO I!Nbk-t� I lu" -H L- rHESE PLANS AND TLL PROPOSED WOF K ARE SUR.-IECT M AbDI CORRECTIONS REQUIRED Eff nELD INSPECTORS I= 8L NECESSARY' IN uptuhlAt To pompryurfm L141 Ti=m InAK1,13 POPIFF -------------- — rREV I DATE DESCRIPTION A 3/30/171 PRELMINARY 8 4/10/17 REMSED 0 7/18/17 FOR P�IT PROJECT NO.: 17-0115.05 =mw N ... = CHECKED BY, P c. sm-Lo _ , 'BSEY o� -1 THIS DMWINO 15 COPYMMIED AND IS THE SOLE PROPER7Y OF ME OWNER. IT IS PRODUCED SOLELY FOR USE BY THE OWNER AND ffS AITUATES. REPRODUCnON OR USE OF MIS DRAWING AND/OR ME INFORMAXION CONTAINED IN Tr IS 1P-- FOR THE PURPOSES OF THESE CONSTRUCTION DRAWINGS, THE FOLLOWING DEFINITIONS SHALL APPLY: 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. OWNER - AT&T MOBILITY ENGINEER - APX ENGINEERING GROUP, LLC. CONTRACTOR - GENERAL CONTRACTOR (CONSTRUCTION) PRIOR TO SUBMITTING HIS BID, THE CONTRACTOR SHALL VISIT THE JOB SITE IN ORDER TO (1) VERIFY ALL EXISTING CONDITIONS, (2) CONFIRM WHETHER ALL DIMENSIONS ARE AS SHOWN ON THE PLANS AND (3) CONFIRM WHETHER THE WORK MAY BE ACCOMPLISHED AS SHOWN. ANY DISCREPANCIES SHALL BE BROUGHT To THE ATTENTION OF THE CONSTRUCTION MWGER. A 20-FOOT HORIZONTAL CLEARANCE DISTANCE SHALL BE MAINTAINED FROM ALL EXISTING POWER LINES. THE CONTRACTOR'S USE OF A CONSTRUCTION STAGING AREA SHALL BE COORDINATED WITH THE OWNER WELL IN ADVANCE OF THE CONSTRUCTION START DATE. LABOR. MATERIAL TOOLS. EQUIPMENT, TRANSPORTATION AND TEMPORARY POWER SERVICES NECESSARY FOR AND INCIDENTAL TO COMPLETION OF ALL WORK SHALL BE PROVIDED AS INDICATED ON THE DRAWINGS AND/OR AS SPECIFIED HEREIN. LABOR AND MATERIALS SHALL BE FURNISHED AS REQUIRED FOR COMPLETE SYSTEMS, INCLUDING ALL ELEMENTS OBVIOUSLY OR REASONABLY INCIDENTAL TO A COMPLETE INSTALLATION, WHETHER OR NOT SPECIFICALLY INDICATED ON THE PLANS. FOR TASKS REQUIRED TO BE PERFORMED BUT NOT CLEARLY DEFINED OR IDENTIFIED BY THE CONTRACT DOCUMENTS. THE CONTRACTOR SHALL NOT START WORK ON SUCH TASKS WITHOUT HAVING RECEIVED WRITTEN AUTHORIZATION FROM THE CONSTRUCTION MANAGER TO PROCEED. THE DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS AND EQUIPMENT UNLESS OTHERWISE. INDICATED BY DIMENSIONS OR DEI`ALS. EXACT EQUIPMENT LOCATIONS MAY 13E MODIFIED AS REQUIRED By ACTUAL FIELD CONDITIONS. IF THE SPECIFIED EQUIPMENT CANNOT BE INSTALLED AS SHOWN ON THESE DRAWINGS, CONTRACTOR SHALL PROPOSE AN ALTERNATIVE INSTALLATION FOR APPROVAL 13Y THE ENGINEER AND THE CONSTRUCTION MANAGER. THE CONTRACTOR SHALL OBTAIN. PAY FOR AND DELIVER ALL REQUIRED PERMITS, CERTIFICATES OF INSPECTION. INCLUDING UTILITY CONNECTION FEES. ETC.. REQUIRED BY THE AUTHORITIES HAVING JURISDICTION AND SHALL DELIVER SUCH DOCUMENTS TO THE OWNER PRIOR TO FINAL ACCEPTANCE OF THE WORK. THE CONTRACTOR'S OPERATIONS SHALL BE CONFINED TO AREAS OF NEW CONSTRUCTION. ALL NECESSARY PROVISIONS SHALL BE MADE TO PROTECT EXISTING IMPROVEMENTS. LANDSCAPING. PAVING. CURBS, GALVANIZED SURFACES. ETC, AND THE CONTRACTOR SHALL BE RESPONS113LE FOR ANY DAMAGE TO SAME RESULTING FROM THE CONSTRUCTION WORK. ALL DISTURBED AND DAMAGED AREAS SHALL BE RESTORED TO THEIR ORIGINAL CONDITION OR BETTER UPON COMPLETION OF ALL WORK TO THE SATISFACTION OF THE CONSTRUCTION MANAGER. THE FOLLOWING CLEANUP TASKS SHALL BE PERFORMED AS FOLLOWS: (1) ON A DAILY BASIS, KEEP THE GENERAL AREA CLEAN AND HAZARD FREE, REMOVING ALL WASTE. DEBRIS AND TRASH FROM THE SITE AND DISPOSING OF SAME IN A LEGAL MANNER. (2) UPON COMPLETION. LEAVE THE PREMISES IN A CLEAN CONDITION AND FREE FROM PANT SPOTS. DUST, OR SMUDGES OF ANY NATURE. ALL EQUIPMENT AND MATERIALS SHALL BE INSTALLED IN ACCORDANCE WITH THE RESPECTIVE MANUFACTURER'S RECOMMENDATIONS EXCEPT WHERE IT IS SPECIFICALLY INDICATED 07HERWISE IN THE CONTRACT DOCUMENTS OR WHERE LOCAL CODES OR REGULATIONS TAKE PRECEDENCE ALL WORK PERFORMED AND MATERIALS INSTALLED SHALL BE IN STRICT ACCORDANCE WITH ALL APPUCA13LE CODES. REGULATIONS AND ORDINANCES. THE CONTRACTOR SHALL GIVE ALL NOTICES AND COMPLY WITH ALL LAWS, ORDINANCES. RULES. REGULATIONS AND LAWFUL ORDERS OF ANY PUBLIC AUTHORITY HAVING JURISDICTION OVER THE PERFORMANCE OF THE WORK. MECHANICAL AND ELECTRICAL SYSTEMS SHALL BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE MUNICIPAL AND UTILITY COMPANY SPECIFICATIONS AS WELL AS LOCAL AND STATE CODES. ORDINANCES AND APPLJCA13LE REGULATIONS. THE CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK AT ALL TIMES, USING THE BEST SKILLS AND ATTENTION. HE SHALL BE SOLELY RESPONSIBLE FOR ALL OF THE CONSTRUCTION MEANS. METHODS, TECHNIQUES. SEQUENCES AND PROCEDURES AND FOR COORDINATING ALL PORTIONS OF THE WORK, INCLUDING CONTACT AND COORDINATION WITH THE CONSTRUCTION MANAGER AND WITH THE OWNER'S AUTHORIZED REPRESENTATIVE. WITHIN TEN (10) WORKING DAYS AFTER PROJECT COMPLETION. THE CONTRACTOR SHALL PROVIDE A COMPLETE SET OF AS -BUILT DRAWINGS. SWEEP TEST, CYLINDER TESTS. LIEN- RELEASES, AND OTHER CLOSEOUT DOCUMENTATION AS REQUIRED BY THE OWNER. ALL SYSTEMS SHALL BE COMPLETELY ASSEMBLED, TESTED, ADJUSTED AND DEMONSTRATED TO BE READY FOR OPERATION PRIOR TO THE OWNER'S ACCEPTANCE. GENERAL NOTES 1. THE APPROPRIATE UTILITY LOCATING SERVICES SHALL BE CONTACTED PRIOR TO THE START OF CONSTRUCTION IN ORDER TO VERIFY THE EXACT LOCATION OF ALL EXISTING UNDERGROUND UTILITIES. 2. THE INSTALLATION OF NEW UTILITIES SHALL BE COORDINATED WITH LOCAL AUTHORITIES. 3. ALL EXISTING ACTIVE SEWER, WATER, GAS, ELECTRIC AND OTHER UTILITIES, WHERE ENCOUNTERED IN THE WORK. SHALL BE PROTECTED AT ALL TIMES. WHERE REQUIRED FOR THE PROPER EXECUTION OF THE WORK. SUCH UTUTES SHALL BE RELOCATED AS DIRECTED 13Y THE CONSTRUCTION MANAGER. EXTREME CAUTION SHALL BE USED WHEN EXCAVATING OR DRILLING PIERS AROUND OR NEAR UTILITIES. 4. RUBBISH. STUMPS, DEBRIS. STICKS, STONES AND OTHER REFUSE SHALL BE REMOVED FROM THE SITE AND DISPOSED OF LEGALLY. 5. ALL EXISTING INACTIVE SEWER. WATER. GAS. ELECTRIC AND OTHER U`nL7nES THAT INTERFERE WITH THE EXECUTION OF THE WORK SHALL BE REMOVED AND/OR CAPPED. PLUGGED OR OTHERWISE DISCONTINUED AT POINTS THAT WILL NOT INTERFERE WITH THE EXECUTION OF THE WORK. SUBJECT TO THE APPROVAL OF THE LANDLORD AND/OR LOCAL UTILITIES. 6. DISTURBANCE TO THE EXISTING SITE DURING CONSTRUCTION SHALL BE MINIMIZED. 7. ANY AREAS OF THE CONSTRUCTION SITE DISTURBED BY THE WORK AND NOT COVERED BY THE TOWER, EQUIPMENT OR DRIVEWAY. SHALL BE GRADED TO A UNIFORM SLOPE. SUCH GRADING SHALL CAUSE SURFACE WATER TO FLOW AWAY FROM AN, MWPMUU SHELTER AND TOWER AREAS AND THE SOIL SHALL BE STABILIZED TO PRIEVENT EROSION. EROSION CONTROL MEASURESAF REQUIRED DURING CONSTRUCTION, SHALL BE IN CONFORMANCE WITH THE LOCAL GUIDELINES FOR EROSION AND SEDIMENT CONTROL S. THE SUB -GRADE SHALL 13E COMPACTED AND BROUGHT TO A UNIFORM GRADE PRIOR TO FINISHED SURFACE APPLICATION. 9. BACKFlLL SHALL CONSIST OF CLEAN SAND FILL APPROVED FOR USE BY THE ENGINEER. NO UNAPPROVED MATERIAL WILL BE ALLOWED. CLEAN SAND FILL SHALL BE FREE OF ALL ROOTS, BOULDERS, OR OTHER DELETERIOUS MATERIAL 10. THE CONTRACTOR SHALL RESTORE ALL DISTURBED AREAS TO EQUAL TO OR BETTER CONDITION THAN ORIGINAL IT. SITE SIGNAGE SHALL BE PROVIDED IN ACCORDANCE WITH THE TECHNICAL SPECIFICATIONS FOR SUCH SIGNAGE AS MAY BE CONTAINED IN THESE DRAWINGS. SITE WORK NOTES 12 MATERIAL; A. ALL STRUCTURAL STEEL WORK SHALL CONFORM TO THE LATEST EDITION OF THE AISC "STEEL CONSTRUCTION MANUAL7. B. ALL STRUCTURAL STEEL WF BEAMS SHALL BE ASTM A992 AND 'HOT DIPPED' GALVANIZED IN ACCORDANCE WITH ASTM A123 AND ASTM A153 STANDARDS. C. ALL STRUCTURAL PLATES. ANGLES, AND CHANNELS SHALL BE ASTM A36 AND -HOT DIPPED- GALVANIZED IN ACCORDANCE WITH ASTM A123 AND ASTM A153 STANDARDS. D. ALL TS MEMBERS SHALL BE ASTM A500 GRADE B (Fy=46ksi). AND "HOT DIPPED" GALVANIZED IN ACCORDANCE WITH ASTM A123 AND ASTM A153 STANDARDS. E. ALL STRUCTURAL PIPE MEMBERS SHALL BE ASTM A500 GRADE B (Fy=42ksi), AND -HOT DIPPED- GALVANIZED IN ACCORDANCE WITH ASTM A123 AND ASTM A153 STANDARDS. F. ALL NON-STRUCTURAL PIPE MEMBERS SHALL BE ASTM A53 GRADE B. AND 'HOT DIPPED" GALVANIZED IN ACCORDANCE WITH ASTIM A123 AND ASTM A153 STANDARDS. Z. DESIGN. FABRICATION, AND CONSTRUCTION OF ALL CONNECTIONS SHALL CONFORM TO AJSC STEEL CONSTRUCTION MANUAL 3. WELDING, A. ALL WELDS. WELDERS. AND WELD INSPECTIONS SHALL CONFORM TO THE REQUIREMENTS OF AWS D I.I. LATEST REVSION. B. ALL WELDS SHALL BE MADE WITH E70XX LOW HYDROGEN ELECTRODES. C. ALL STEEL SHALL BE SPRAY GALVANIZED AFTER WELDING. 4. ALL BOLTS SHALL BE GALVANIZED %' DIAMETER. A325-N, UNLESS NOTED OTHERWISE AND TIGHTENED TO A "SNUG TIGHT" CONDITION AS DEFINED BY AISC. SECURE NUT WITH LOCKING WASHER. S. ANCHOR BOLTS SHALL CONFORM TO ASTM A307, UNLESS NOTED OTHERWISE. 6. THE CONTRACTOR/STEEL FABRICATOR SHALL LOCATE ANY REINFORCEMENT IN THE STRUCTURAL MEMBERS IN SUCH A MANNER SO THAT THERE WILL NOT BE CONFLICT WITH THE REINFORCEMENT WHEN INSTALLING ANCHORS. THE ANCHORS SHALL BE INSTALLED PER THE MANUFACTURER'S INSTRUCTION. 7. THE CONTRACTOR/STEEL FABRICATOR SHALL CONFORM TO THE MINIMUM EDGE DISTANCE REQUIREMENTS IN ACCORDANCE WITH THE AISC MANUAL OF STEEL CONSTRUCTION. B. ALL STRUCTURAL STEEL SHALL BE FABRICATED TO FIT AT BOLTED CONNECTIONS WITHIN X6 INCH TOLERANCE. STRUCTURAL STEEL SHALL NOT BE FLAME CLIT UNDER ANY CIRCUMSTANCES WITHOUT APPROVAL OF THE ENGINEER. 9. THE CONTRACTOR/STEEL FABRICATOR SHALL CAP OR SEAL ALL PIPES AS REQUIRED TO PREVENT RAINWATER INTRUSION. 10. THE CONTFACTOR/STEEL FA13RICATOR SHALL SUBMIT SHOP DRAWINGS FOR REVIEW PRIOR TO ANY STEEL FABRICATION. AT THE CONTRACTOR'S OPTION, FIELD SPLICES MAY 13E USED FOR ERECTION PURPOSES. IF FIELD SPLICES ARE USED, THE SHOP DRAWINGS SHALL INCLUDE ALL DETAILS FOR THE PROPOSED FIELD SPLICES. 11. AT THE CONTRACTOR'S OPTION, SHOP WELDS MAY BE USED INSTEAD OF FIELD WELDS. 12. SUBMIT ORIGINAL SHOP DRAWINGS. INCLUDING COMPLETE DETAILS, SCHEDULES OF FABRICATION AND ASSEMBLY, PROCEDURES. AND DIAGRAMS. INCLUDE DETAILS OF CUTS. CONNECTIONS, CAMBER. HOLE, AND OTHER PERTINENT DATA. INDICATE WELDS BY STANDARD AWS A2.1 AND AZA SYMBOLS, AND SHOW SIZE. LENGTH, AND TYPE OF WELD. PROVIDE SETTING DRAWINGS, TEMPLATES. AND DIRECTIONS FOR INSTALLAT10N OF ANCHOR BOLTS AND OTHER ANCHORAGES TO BE INSTALLED AS WORK OF OTHERS' SECTIONS. GENERATOR NOTES 1 3_ 'REY DATE ____s DESCRIPTION A 3/30/17 PRELIMINARY B 4/10/17 RENI� 0 7/18/17 FOR PERMIT PROJECT NOj 17-0115.0 DRAWN ft. CHECIKED BY: C, BELLO u EXISTING SPRINT DIESEL GENERATOR EXISTING SPRINT CONCRETE EQUIPMENT PAD EXISTING COAX BRIDGE (TYP.) PROPOSED AT&T CABLES (APPROXaMATE LENGTH 240':k) (SEE NOTE) ,7� -�IL� �x-x-x-x-x-x-x-x-x-x- tx-X-X-X-X-x A/C C z x x EXISIING SPRINT EQUIPMENT SHE -TER EXISTING AT&T E UIPMENT SHELTER EXISTING EQUIPMENT SHELTER (US GOVERNMENT) z EXISTING GRAVELED A/C A C AREA EXISTING ATC EQUIPMENT A/C I - - SHELTER x F- x x x - x x EXISTING 200'± GUYED TOWER L EXISTING 16'± WIDE ACCESS GATE EXISTING 6' HIGH CHAIN—UNK FENCE W1 3—STRAND BARBED WIRE NQMI CONTRACTOR SHALL REMOVE EXISnNG UNUSED COAX AS NEEDED TO CREATE SPACE FOR PROPOSED CABLES. COMPOUND PLAN EXISTING 13'± WID E ACCESS GATE E)(IS'nNG VERIZON— WIRELESS LP TANK ENSTING VERIZON — WIRELESS EQUIPMENT CABINET (TYP. OF 3) MEN X--=IX - x - x - x x - x EXISTING SPRINT EQUIPMENT CABINET (TYP. OF 2) EXISTING SPRINT UTILITY H—FRAME q 11 \ — — — J— x EXISTING 12'± WIDE ACCESS GATE EXISTING VERIZON WIRELESS LP GENERATOR x EXISTING UTILITY H—FRAME (TYP.) 1 rRW DATE OESCR[MON A 3/30/17 PREUMINARY 0 4/10/17 REVISED 0 7/18/17 FOR PERMIT FPMECT 10 17-0115.05 CHECKED By'. C. BELLO M. ASSET THIS DRAWING IS CO�GHTED AND M THE SOLE PROPERIY OF THE OWNER. rr IS PRODUCED SOLELY FOR USE BY THE OWNER AND ITS AFF[I-ATES. REPRODUCIION OR USE OF THIS DRAWING ANDIOR THE INFORMATION CONTANED IN rr IS FORBIDDEN WTDiOU`r THE WRnTEN WIN a jTM41=1 4 IN G I IN 0 E It I N G G R 0 U P 3�13 �MDE D� � 525 M�. F. 33027 CEMRCA� OF AMORIMON 31948 at&t 200 1 W 64� WR� FORT LWQVID�E. FL 3MO9 A. %% No. 63312 j // : w A, i 'Z-01-11� I DATE OF SIGNAVRE. 7/10/17) RIVERPARK . lQIO OYER ROAD POR" ST LUCIE. FL �952 s"� NZE COMPOUND I PLAN I SliEff NUMBER C 1 �o �"—L' T'o - RAD CENTER OF EXISTlNG AND PROPOSED AT&T ANTENNAS EL 190'* EXISTING AT&T RAYCAP FIBER DISTRIBUTION UNIT TO BE REMOVED AND RELOCATED J34 RAD CENTER OF EXISTING NEXTEL ANTENNAS EL 172:t EXISTING AT&T ANTENNA MOUNT M BE REMOVED AND REPLACED RAD CENTER OF EXISTING VERIZON WIRELESS ANTENNAS (TYP. OF 9) EL 161"* RAD CENTER OF EXISTNG SPRINT ANTENNAS ELEV. igo'± EL 150'± Ij 11 E)OSTING AT&T RRU TO BE RELOCATED (TYP. OF 6) RAD CENTER OF EXISTING US GOVERNMENT ANTENNAS EL. 126'± —SECTOU A7 - 86 kl� If E)aSTING AT&T ANTENNA if 11 MOUNT TO BE REMOVED & REPLACED rl If OF 3) RAD CENTER OF EXISTING US GOVERNMENT ANTENNAS EL 108'± CM. EXISTING ANTENNA PLAN NTs 2 PROPOSED AT&T ANTENNA MOUNT (OONNECT-rr MODEL PVFM12-3-B) CIYP. OF 3) REUDCATED AT&T RAYCAP r4 FIBER DISTRIBUTION UNIT r-4-� PROPOSED AT&T FIBER ommaunON UNIT PROPOSED AT&T ANTENNA (IYP. OF 9) (SEE NOTE 2) ELEV. lgo,± —SE�CTOU A7. - 85* RELOCATED AT&T t' �2 RRU C". OF 6)�o GRADE NOTES EL 0 1. PRIOR TO CONSTRUCTION, CONTRACTOR SHALL ADVISE MASTEC CONSTRUCTION MANAGER rl OF THE ESTIMATED SITE DOWN TIME 2. CONTRACTOR SHALL USE CONDUIT/INNER-DUCT FOR THE DC AND FIBER TRUNK CABLES NOTES, PROPOSED AT&T WHILE THEY ARE ROUTED WITHIN THE TOWER. RRU (TYP. OF 6) 1. CONTRACTOR SHALL INS17ALL RAYCAP 3. THIS DRAWING IS INTENDED TO DEPICT THE GENERAL LOCATION AND HEIGHT OF THE DISTRIBUTION UNIT WITHIN 15 FEET FROM PROPOSED ANTENNAS ON THE EXISTING TOWER. CONSTRUCTION SHALL NOT PROCEED ALL RRH'S. UNTIL A STRUCTURAL ANALYSIS REPORT HAS BEEN COMPLETED BY A PROFESSIONAL ENGINEER REGISTERED IN THIS STATE. CONCLUDING THAT THE EXISTING TOWER IS 2. REFER TO CURRENT RFDS FOR ANTENNA SrRUCTURALLY ADEQUATE TO RESIST THE EXISTING AND PROPOSED LOADS. MODELS. . ' " " m '11 ELEVATION PROPOSED ANTENNA PLAN NMI 3 rREV I DAM I DESCRIPTION A 13/30/171 PRELIMINARY 0 14/10/171 REMSED 0 7/18/17 FOR PERWT PROJELNO:�.. 17-IM 15.05 DRA.N CHECKED BY. C. BELLO � ABBEY THIS DRAWING 13 COPYMGKrED AND IS THE SOLE PROPERTY OF WE OWNER. IT IS PRODUCED SOLELY FOR USE BY ME OWNER AND ITS AFFUATES. REPRODUCTON OR USE OF MIS DRAWING MDIOR WE INFORMATION COWAINED IN IT IS FORBIDDEN WITHOUT ME WRITTEN PERMISSION OF T14E OWNER. -PROPOSED MOUNTING BRACKET C PROPOSED MOUNTING BRACKET PROPOSED ANTENNA TILT (TYP. OF 2 PER RRU) (TYP. OF 2 PER RRU) BRACKET PROVIDED W/ (SEE NOTE 3) (SEE NOTE 3) ANTENNA W__PROPOSED PIPE MOUNTING .Fes,zl= BRACKETS PROVIDED W/ ANTENNA (TYP.) rREV I DATE I DESCRIPIIO�N A 13/30/171 PRELIMINARY B 4/10/17 REMSED o 7/ia/17 FOR PERMIT C' No" 17-0115.05 PRC'JL-- I DRAWN ;Y: CHECKED BY.. I M. ABBEY PROPOSED AT&T I THIS DRAWING IS COPYRIGHTED AMID IS ANTENNA (TYP.) TlIE SOLE PROPEI?TY OF THE OWNER. IT IS PRODUCED SOLELY FOR USE BY INE OWNER AND ITS AFFIUAM. REPRODUCTION OR USE OF THIS DRAWNG AND/OR THE INFORMATION CONTANED IN -PROPOSED ANTENNA IT IS FORUBJISSEN WT`OUr IHE WRIITEN MOUNTING PIPE (IYP.) RELOCATED AT&T ER ON OF THE OWNER. RRU (TYP.) PROPOSED. AT&T RRU (TYP.) A PROPOSED ANTENNA PROPOSED ANTENNA MOUNTING PIPE (TYP . MOUNTING PIPE (TYP.) apA I , 7ff NOTES' NOTES- RNGINEgRING GROUP 1. UNIT SHALL BE MOUNTED AS PER 1. UNIT SHALL BE MOUNTED AS PER 3MO WMDE DRNE. SUn 5n PROPOSED ANTENNA MANUFACTURER'S RECOMMENDATIONS. MANUFACTURER'S RECOMMENDATIONS. Ml�. M 330V BRACKEr PROVIDED W/ 2. CONTRACTOR SHALL TIGHTEN ALL BOLTS TO A 2. CONTRACTOR SHALL TIGHTEN ALL BOLTS TO A CERTIRCATE OF A�ORIZAPON 31948 L ANTENNA *SNUG TIGHT" CONDITION AS DEFINED BY AJSC. 'SNUG TIGHT* CONDITION AS DEnNED BY AISC. 3. BRACKET TO BE CONFIGURED TO ACCOMMODATE 3. BRACKEr TO BE CONFIGURED TO ACCOMMODATE A2 MODULES. A2 MODUI Fq. ANTENNA MOUNTING DETAIL Nmll RRU MOUNTING DETAIL NmJ2 RRU MOUNTING DETAIL NTsj 3 2 - at&t PROPOSED 2W O.D. MOUNTING EXISTING TOWER PIPE (1--r LONG) WITH �50 LEG (TYP.) ti�� CLAMP STYLE CROSSOVER 2001 M 64M STRIMT PLATE (TYP.) FORT ULJOUDAUE. Il 33309 PROPOSED RAYCAP POLE MOUNT PROPOSED ANTENKA MOUNT BRACKET (PROVIDED BY MANUFACTURER) (CONNECT -IT i PVFM12-3-B. PROPOSED AT&T RAYCAP FIBER AND OR APPROVED EQUAL) % A DO DISTRIBUTION UNIT W1 INTEGRATED .......... JP SURGE PROTECTOR c E III (PART# DC6-48-60-18-gC) OW.) FIBER OR DC BUNDLE 0, 0� No. 6a3l2 .0 � ENSTING OR PROPOSED ANTENNA MOUNT FRAME IMP.) PROPOSED FIBER AND DO CABLE ROUTED A T FROM EQUIPMENT (2) %' ROSENBERGER THREE PAIR POWER CABLES PARTJ WR-VG86ST-BRD AND ROSENBERGER IB-PAIR FIBER CABLE PART# 118-1.989-034-75000 PER SECMR) DATE OF SIG RF' 7/18/1 PROPOSED FIBER AND DO CABLE RUBBER GROMMET ROUTED TO PROPOSED FIFTH UNITS (CONNECT -IT. OR 11VERPARK (1) ROSENBERGER SINGLE PAIR POWER APPROVED EQUAL) CABLE SUPPORT BLOCK CABLES PARTO WR­VG82Sr-BROA AND (CONNECT -IT, OR (1) ROSENBERGER SINGLE PAIR FIBER APPROVED EQUAL) CABLE PART# FB-LSBB-035-5000 PER RRH) 1480 DYER ROAD NOTES u MIRY ST LUCIE. FL �952 1. UNIT SHALL BE MOUNTED AS PER MANUFACTURER'S RECOMMENDATIONS. SHM NAME 2. CONTRACTOR SHALL TIGHTEN ALL BOLTS TO A 'SNUG TIGHT' CONDITION AS DETAILS DEFINED BY AISC. 3. CONTRACTOR SHALL INSrALL RAYCAP DISTRIBUTION UNIT WITHIN 15 FEET FROM ALL RRH'S. SHW NUMBER ,.SURGE SUPPRESSOR MOUNTING DETAIL wrs 4 ANTENNA MOUNT DETAIL NTs 5 FIBER AND DC CABLE MOUNTING DETAIL C3 ANTENNA POSITION # 1 ANTENNA POSITION 3 NOTES- 1. CONTRACTOR SHALL USE ERICSSON PROVIDED DC POWER CABLE CONNECTOR. 2. CONTRACTOR SHALL REMOVE E)(ISnNG UNUSED COAX AS NEEDED TO CREATE SPACE FOR PROPOSED CABLES. ANTENNA POSITION # 4 s2M��� I MA 30A 30A 30A 30A 30A 20A [ LTE DIGITAL UNIT ------- --- - - - Full-1-900-1 I RRH ST. LUCIE COUNTY BUILDING DIVISION REVIEWED FOR 00 c REVIEWE BY DATE _ ZA�NS AN�iVRMIT MUST BE KEPT ON JOB OR - NO INSPECTION WILL BE MADE 2. -(l) RACK MOUNTED RAYCAP DC SURGE PROTECTOR (DC6-48-60-RM). 3. RAYCAP FIBER AND OC DISTRIBUTION UNIT (DC6-48-60-18-8F). 4. #8 AWG CONDUCTORS. 5. PROVIDE (2) B-CONDUCTOR #8 AWG BUNDLES FOR DC POWER FROM RACK MOUNTED RAYCAP SURGE PROTECT10N UNIT TO THE RAYCAP FIBER AND DISTRIBUTION UNIT ON TOWER. 6. PROPOSED FIBER AND DC CABLE ROUTED TO PROPOSED RRH UNITS. I RISER DIAGRAM (TYP. PER SECTOR) 1 11 DC RISER DIAGRAM . . 12 j rREV I DATE I DESCRIPTION A 3/3D/171 PRIEUMINARY B 4/10/17 REVISED 0 7/18/17 FOR PERMIT PROJECT NO.: 17-0115.05 DEW:::BY:::� =CHS KIM EY: C C. BELLO M. AMBEY 10 THIS DRAWING IS COMMITTED AND IS ME SOLE PROPERTY OF THE OWNER. IT IS PRODUCED SOLELY FOR USE BY THE OWNER AND US ARFIUATES. REIRRODUCT"N OR USE OF THIS DRAWING AND/OR ME INFORMATION CONTAINED IN IT IS FORBIDDEN W`MOW THE W P MISSION OF THE OWNER!TEN .0 PROPOSED ANTENNA MOUNTING PIPE (TYP.) RAYCAP FIBER AND DO DISTRIBUTION UNIT CTYP.) PROPOSED AT&T ANTENKA (TYP.) EXISTING SECTOR GROUND BAR CTYP.) PROPOSED #2 SOLID COPPER TINNED IN NMLT (NON-METALLIC UQUID-TIGHT) cm.) NOTESi 1. CONTRACTOR SHALL REFER TO AT&T GROUNDING AND BONDING PRACTICE TP-76416. ALL EXOTHERMIC CADWELDS SHALL BE PERFORMED BY CERTIFIED TECHNICIAN. 2- PROVIDE WEATHER PROOFING AND GROUNDING KIT TO BOND DC POWER CA13LE SHIELD TO EXTERNAL 14ATCH PLATE GROUND BAR. 3. PROVIDE GROUND CONNECTION FOR DO POWER CABLE SHIELD TO "P" SECTION OF CRGB WITHIN SHELTER. .4. CONTRACTOR SHALL USE THEFT RESISTANT GROUND WIRES AND BARS WHEN FEASIBLE. 5. CONTRACTOR SHALL MAINTAN A 12" MINIMUM GROUND WIRE BEND RADII. 6. GROUND LUGS. HEATSHRINK AND,CLAMPS DEVICES SHALL COMPLY WITH AT&T GROUNDING AND BONDING PRACTICE TP-76416. "IbIINU UKLIUNL BAF 12 SOLID COPPER TINNED IN NMLT (NON-MErALUC UQUID-nGHT) (TYP.) SS WASHER %'X;4' SS BOLT SS WASHER SS LOCK WASHER SS NUT I TYPICAL GROUND BAR CONNECTION DETAIL wsl 21 1. RECORD DRAWINGS: MAINTAIN A RECORD OF ALL CHANCES. SUBSTITUTIONS BETWEEN WORK AS SPECIFIED AND INSTALLED. RECORD CHANGES ON A CLEAN SET OF CONTRACT DOCUMENTS WHICH SHALL BE TURNED OVER TO THE CONSTRUCTION MANAGER UPON COMPLEnON OF THE PROJECT. 2. GUARANTEE/WARRANTY. GUARANTEE INSTALLATION TO BE FREE OF DEFECTS. SHORTS. GROUNDS. ETC.. FOR A PERIOD OF ONE YEAR. FURNISH WARRANTY SO THE DEFECTIVE MATERIAL AND/OR WORKMANSHIP WILL BE REPARED/REPLACED IMMEDIATELY UPON NOTIFICATION AT NO COST TO THE OWNER FOR PERIOD OF WARRANTY. 3. ALL 71E WRAPS SHALL BE CUT FLUSH WITH APPROVED CUTTING TOOL TO REMOVE SHARP EDGES. 4. ELECTRICAL METALLIC TU13ING (EMT) OR RIGID NONMErALUC CONDUIT (I.E.. RIGID PVC SCHEDULE 40, OR RIGID PVC SCHEDULE 80 FOR LOCATIONS SUBJECT TO PHYSICAL DAMAGE) SHALL BE USED FOR EXPOSED INDOOR LOCATIONS. S. UQUID-TIGHT FLEX113LE METALLIC CONDUIT (UQUID-TITE FLEX) SHALL BE USED INDOORS AND OUTDOORS. WHERE VIBRATION OCCURS OR FLEXIBILITY IS NEEDED. 6. WIREWAYS SHALL BE EPDXY -COATED (GRAY) AND INCLUDE A HINGED COVER. DESIGNED TO SWING OPEN DOWNWARD; SHALL BE PANDUIT TYPE E (OR EQUAL); AND RATED NEVA 1 (OR BEnER) INDOORS, OR NEMA 3R (OR BETTER) OUTDOORS. 7. EQUIPMENT CABINETS. TERMINAL BOXES, JUNCTION BOXES, AND PULL BOXES SHALL BE GALVANIZED OR EPDXY -COATED SHEET STEEL. SHALL MEET OR EXCEED UL 50, AND RATED NEMA 1 (OR BETTER) INDOORS. OR NEMA 311 (OR BETTER) OUTDOORS. B. MErAL RECEPTACLE. SWITCH. AND DEVICE BOXES SHALL BE GALVANIZED, EPDXY -COATED, OR NON -CORRODING; SHALL MEET OR EXCEED UL 514A AND NEMA OS 1; AND RATED NEMA I (OR BErrER) INDOORS, OR WEATHER PROTECTED (WP OR E3ErFER) OUTDOORS. 9. NONMErALUC RECEPTACLE, SWITCH, AND DEMCE BOXES SHALL MEEr OR EXCEED NEMA OS 2; AND RATED NEVA 1 (OR BETTER) INDOORS. OR WEATHER PROTECTED (WP OR BETTER) OUTDOORS. 10. CONTRACTOR SHALL REFER TO AT&T GROUNDING AND BONDING PRACTICE TP-76416. `RW DATE DESCRIPTION A 3/30/171 PRELIMINARY 8 4/10/17 REMSED 0 7/18/17 FOR PERDAT �PROJECT 40. 17-0115.05 DRAWN BY. CHECKED BY. C. BMW U. ABBEY T141S DRAWING IS COPYRIGKnM AND IS THE SOLE PROPSM OF THE OWNER. IT 15 PRODUCED SOLELY FOR USE BY THE OWNER AND ITS AFFILIATES. REPRODUCTION OR USE OF THIS DRAWING AND/OR THE INFORMATION CONTAINED IN IT IS FORBIDDEN WT14CUT Tr[E WRITTEN PERMISSION OF THE OWNER. .A ap ENGINEERING GROUP 3�13 MMOE ORN� SUITE Sn MIMIMR . F. 33027 CMn�M OF AMORIUAWN 31948 at&t 2001 W 841h �EET FORT �UDERD� F. 33JO9 No. 6831 S DATE OF SffiNATURE:-_ 7/18/17 RIVERPARK 1480 DYER ROAD PORT BY LUCIE. F. 34952 GROUNDING DETAILS AND NOTES �GROUNDING DIAGRAM (TYP.) . NTsj 11 GROUNDING NOTES _T_31 E2