HomeMy WebLinkAboutMISC EMAILF ENGINEERING FOR ARCHITECTURE December 12, 2017 David Johnson St. Lucie County BOCC Planning & Development Services 2300 Virginia Avenue Fort Pierce, FL 34982 SCANNED BY St. Lucie County Re: Permit No. 1707-0121: St. Lucie County Jail Freezer Slab Building Division: FE DEC 2 7 2017 PER!AITTIP,IG St. Lucie COUntY, FIL Building inspector comments for the St. Lucie County Jail freezer addition, permit no. 1707-0121, dated December 7, 2017, indicate "Engineer's approval needed for overpour of slab." TLC's acceptance is as follows: In order to provide a level surface on which to install the outdoor freezer, a topping slab was installed to a maximum thickness of 1-1/2" (Product: Rapid Set "Mortar We). TLC approves of the installation of the topping slab. To accommodate the topping slab, the freezer attachment anchor length was increased to provide the freezer manufacturer's 1-1/4" minimum required embedment into the slab -on -grade below. 1/4" x 6" Tapcon anchors were used in lieu of 1/4" x 4" Tapcon anchors. TLC approves of this anchor substitution. Please let me know if you require any additional information. Sincerely, TLC E I hitecture Ca 4E-nTiien�eeering for Arc , .1/ I g , P FL 7763 r Senior Structuryaler Cathy Cathy Tiedge G 2017.1 13:07: Tiedge-05100 LAMWobsN517069 Rock Road Jail Freezer Addition\CorrespondencekLefter to lnspector.docx TLC ENGINEERING FOR ARCHITECTURE 874 Dixon Boulevard, Cocoa, FL 32922-5809 Phone 321.636.0274 www.tic-engineers.com Fax 321.639.8986