HomeMy WebLinkAboutREVIEW COMMENTSSCANNED Planning B Development Services REVIEW COMMENTS BY Building B Code Regulation Division St. Lucie County 2300 Virginia Avenue Fort Pierce, FL U982 Phone:(772)462-2172 Fax:(772)462.6443 Page 1 PROPERTY INFORMATION Address: 6200 Nueva Lagos Owner(s): Wynne Building Corp City / State / Zip: Fort Pierce., FI 34957 t Parcel #: 1306-111-0001-000/0 Jurisdiction: SAINT LUCIE-COUNTY Zoning: PUD Lot#: Block: APPLICATION INFORMATION i i Permit Number: 1707-0578 Stories: Automatic Sprinkler System? No I i Permit Type: COMMERCIAL RENOVATION CONTRACTOR INFORMATION Contractor Name: Matthew Wynne Fax Number: 772-878-0224 Business Name: Wynne Development Corp e@Spanishlakes.Com S Email: u Business Addr: 8000 S Us 1 Ste 402 - City I State / Zip: Port St Lucie, FI 34952 REVIEWS AND COMMENTS Review Tyne Status Reviewed By Date Started Date Completed Date Released -FRONT COUNTER REVIEW COMPLETE Lashahna Ingram 7127/2017 712712017 7I2712017 Comment: I j PLANS EXAMINER REVIEW INCOMPLETE Joe Cicio 8/212017 Comment: " SCOPE OF WORK"ARCHITECT TO MODIFY THIS SCOPE TO EXACTLY WHAT IS ON PLANS • THERE ARE [ 8/2/2017 2 ] DIFFERENT TYPES OF TILE SHOWN ?? " NOTES STATE TO ADHERE EACH TILE PER NOTE IN BOX NOTE IN BOX STATES NAILS ?? - Comment: FL# 16048 FOR THE TRI-BUILT UNDERLAYMENT DOES NOT MEET THE REQUIRED DESIGN PRESSURES OF 1 8/2/2017 -66 • THE ONLY PRODUCT WHICH IS ACCEPTABLE IS THE S/A HT TU FOR UNDER TILE' 5.6.4.1 IN THE L PRODUCT APPROVAL ONLY MEETS -45 FOR UNDERLAYMENT Comment: IF USING FOAM SUBMIT THE PRODUCT APPROVAL IN DUPLICATE FOR THE FOAM / MUST BE FL# 6332 OR 8/2/2017 FL717 PER THE PRODUCT APPROVAL • ARCHITECT TO DETERMINE THE AMOUNT OF FOAM USED FOR I EACH TILE TO MEET THE REQUIRED DESIGN PRESSURES AND NOTE ON PLANS 8/2/2017 Comment: WHICH DESIGN PRESSURE BOX ON PLANS SHOULD WE GO BY / THE PERMITTING INFO OR ROOF ( SHEATHING CALCS Comment: PLEASE NOTE THAT THE COMMENTS ARE FOR THE CLARIFICATION OR CORRECTION OF THE ' SUBMITTED DOCUMENTS. ADDITIONAL REVIEW MAY BE REQUIRED AFTER SUBMITTING CORRECTED DOCUMENTS PLEASE NOTE: (1) ALL REVIEW COMMENTS WHEN ANSWERED WILL REQUIRE A COVER LETTER c ADDRESSING WHERE THE CHANGES WERE MADE, (2) ALL CHANGES WILL BE REQUIRED TO BE CLOUDED 8/2/2017 ON THE PLANS AND (3) THE CONTRACTOR WHEN RESUBMITTING WILL BE REQUIRED TO INSERT THE NEW UPDATED PAGES INTO THE PLANS OR IF THE CONTRACTOR PREFERS, A REVISED COMPLETE SET OF PLANS CAN BE SUBMITTED PLEASE NOTE ANY COMMENT NOT ADDRESED MAY BE SUBJECT TO AN ADDITIONAL REVIEW FEE PER ST. LUCIE COUNTY RESOLUTION #13-196 COMMENTS SENT