HomeMy WebLinkAboutFOUNDATION DESIGNFLCF2IDA ENGINEERING i4ND_OESIGN.,.INC, I BY LU 0 St. Lucie County Liberty Tire Concrete Foundation Design for Baghouse by Building 6 Project No: 14-1440 Task 15 Prepared For N 'tpA.`R.`E�e��SFOgc i� Liberty Tire Recycling ?> F ti ti * No. 74461 \9a �70 : STATEoF Liberty �O`, ty� ���•'� ��� TLRER't:CYCl1NG. L /8/11111110�\ 9675 Range Line Rd Port St. Lucie, Florida 34987 RECEIVED OCT 18 2017 PERMITTMG St. Lucie County, FL Av4ml re'-Z� Prepared By Florida Engineering & Design, Inc. 255 County Road 555 South Ahmadreza Sedaghat�NC Bartow, FL 33830 '•,. - P.E. #74461 www.fedinc.com OCT 5 0 my October 7, 2017 Report of Findings and Analysis Sectionl 1. Introduction Project Location 9675 Range Line Rd Port St. Lucie, Florida 34987 This project entails the structural analysis and design of concrete foundation to resist the Dead, Live and Wind loadings resulted from the proposed baghouse. Arrangement of the baghouse is indicated in Figure 1. The analysis and design of the foundation based on the loading of the baghouse and its critical tributary area is summarized in section 2. Figure 1- Baghouse Section 2 Input 1- Unfactored Load Determination Output Diameter of the Baghouse 120 (inch) 10.0 (ft) Base Area of the Baghouse 11,304.0. (inch) 78.5 (ft Heigh of the Baghouse 487 (inch) 40.6 (ft) Volume of the Baghouse 4,691,160 I (inch) 2,715 (ft') Content of the Baghouse Tire Fibers TriMlarea (qary Density of the Content of the Baghouse 52 (lb/ft) Total Dead Weight of the Baghouse 1 ;700 (lb) Total Live Weight of the Baghouse 141;169 - (1b) Tributary Area (1) 2890 (ft') Tributary Area (1) 28.0 (ftz) Density of Concrete 150 (lb/ft') Density of Steel Rebar 4' (lb/ft') Thickness of the Grout 1 (inch) 6.083 (ft) Thickness of Concrete Foundation 2 (inch) 2 I (ft) Dead Weight of the Grout 3 6133-",I z (lb) Dead Weight of the Concrete 86;700'^�, (lb) Foundation in Tributary Area (1) Dead Weight of Rebars in the Cone. 03- (lb), Found. In Tributary Area (1) Dead Weight of the Concrete g6;700=j� (1b) Foundation in Tributary Area (1) Dead Weight of Rebars in the Cone.li ,'' 'I 335,; (lb) Found. In Tributa v Area (1) F 2 - Tributary Area Figure 2- Tributary Area (1) 3- Determination of Wind Loading Risk Category of the Structure I Va =V„ -0b (Equation16-32) where: V a= nominhbdesign wind speed V„= strength design wind speeds determined from Fig- ures 1609A, 1609B. or 1609C. V„, (mile/h) 45 V„d (mile/h) 112- Figure3 - Project Site FBC 2014 - Table 1604.5 FBC 2014 - 1609.3.1 FBC 2014 - Figure 1609C Wind Exposure Exposure C Wind Loading on the Baghouse was Determined Based on the Provisions of the Alternate all Heights Method in Section 1609.6. 1609.6.3 Design equations. When using the alternative all -heights method; the MWFRS, and components and clad- ding of every structure shall be designed to resist the effects of wind, pressures on the building envelope in accordance with,Equation 16-34. P.=q;K;C.[Ka] (Equation'16-34) Cnm(h/D=4) 0.3 Kz (Maximum Selected) .1 Kzt q:(psf)for V,m q, (psf) for V,:a 3'0'2S Pops (psfl, for V,r P.e,(psf), for Va:a ,, 24.3 FBC 2014 1609.4.3 FBC 2014 1609.1.1 FBC 2014 1609.6.3 FBC 2014- Table 1609.6.2 2 ASCE 7-16, Table 27.3-1 ASCE 7-16, Table 26.8-2 FBC 2014- Table 1609.6.2(1) 4- Load Combinations A- Load Combinations using Strenght Design or Load and Resistance Factor Design (To evaluate the carrying capacity of concrete foundation) D: Dead Load L: Live Load W: Wind Load B- Load Combinations using Allowable Stress Design (To evaluate the Carrying Capacity of the soil under the Concrete Foundation) D+tJ� S i�p�0!bW�� jp 0.951E tl!45W� �076D' 5- Evaluation of the Lateral Resistance of the Soil FBC 2014- 1605 FBC 2014- 1605 FBC 2014- Coefficient of friction 0,25 1806.2 Analysis is based on the Tributary Area I or 2 Lateral Capacity Load Combinations Lateral Sliding Force Compression Force Sliding below the Load Combinations below the Concrete Resistance Concrete Sliding Status Foundation) (Kips), p (Kips), Foundation N µ . N (Kips) D+L 252 63 0 OK — D+0.75L _ 217 54 0.0 OK D+0.6Wa, 111 1 28 4.9 1 OK D+0.75L+0.45W,,, 217 54 3.7 OK 0.613+0.6W„a 67 17 4.9 OK 0.61) 67 17 0.0 OK 6- Evaluation of the Vertical Carrying Capacity of the Soil Allowable Vertical Foundation I 2000 Pressure (psi) I Moment of Inertia of the 4,219 Tributary Area (1 or 2), (ft°) Analysis is based on the Tributary Area Stress Distribution P M'y A + 1 FBC 2014- Without Presence of Geotechnical Report -Table 1806.2 Vertical Capacity Load Combinations Moment . Maximum below the Compressive Compression Force Concrete Stress below Vertical Load Combinations below the Concrete Compression Foundatio the Concrete Foundation (Kips) � F) Status n Foundation (Kips-ft) (Kips/ft') D+L 252 0 0.87 OK D+0.75L 217 1 0 0.75 OK 13+0.6W,, 111 116 0.62 OK 13+0.751,+0.45W°, .217 87 0.93 OK 0.613+0.6W„° 67 116 0.47 OK 0.61) 67 0 0:23 OK 7- Evaluation of the Carrying Capacity of Concrete Against Punching Shear and Moment is based on the Tributary .1. Evaluation of the Concrete Foundation Punching hear Capacity b0 (in), Perimeter around the Base Distributed in Plate 2 Layers d (in), Specific Depth of Concrete Foundation L (in), Width of Tributary Area 1 �01� Minimum Temperature Shrinkage Steel As= (in'/ft) 0.52 0.0018bh ACI-318-11 Proposed Longitudinal As (in`/ft) 0.818 Use #5 @ 9" Top and Bottom Vc J = .0.75.47i pb 60 Ksi Steel Layer �• c Od ACI.318 �. Vc (kips), Per Column 526.0 17.2. Evaluation of the Concrete Foundation Moment Capacity ,(V Mn _ b.9. AS. far. J. d ACI-318-11 �. Mn Allowable flexural Strength of Concrete Foundation Ki -ft/ft- - Table 4 - Load Combinations for Concrete Foundation Moment Capacity Critical Punching Force on the Moment Load Combinations Concrete Foundation, Applied on Design Status Per Column (Kips) the Concrete Foundation (Kips J[Vft) 1.413 7.5 2.7 OK 1.2D+1.6L 62.9 6.3 OK 1.21)+0.5W„h 10.8 Il.l OK 1.21)+1W h 15.2 19.8 OK 0.91)+1W n 13.6 19.2 OK 8- Evaluation of the Baseplate Anchor Bolts strength for Rigid Connections under Wind Loading Maximum Moment due to Wind Loading on the Concrete Foundation, 116.5 Mu (kip-ft), From Part 6 Total Number of Anchor Bolts, for one 4 base plates Distance between center of Bolts along 9 the Applied Moment ft Diamter of the bolts in 0.875 Yielding strength of the bolts.(ksi) 36 Ultimate Strength of the Bolts (ksi) 58 0:75 ,Allowable tensile strength F,Ab 0.375F�Ab, 2.00 ' Allowable Tensile Strength of the Bolts 13.1 (Kips) Maximum Applied Force on a Single Bolt due to the Moment Resulted from 1.6 13.1 (kipsp The Design is the Wind Loading (kips) I.5(kips) Adequate