Loading...
HomeMy WebLinkAboutAIR BALANCE INFORMATIONA & L MrBalance Corp. THE BEST DIGITAL PRECISION 7345 W 4 Ave. # 405 Hialeah FI 33014 Phone:(786)541-4038 Project: Villa Pagano Restaurant Address: 8765 South USl Highway Port St Lucie, FL 34952 SCANNEo QY St. Lucie county Date: 03/03/2018 "This report reflects exact quantities obtained from digital instruments in accordance with SMACNA and NBI (National Balance Institute), and NEBB coupled with project specifications. The final adjustments have been made in accordance with the Testing, Adjusting and Balancing Bureau." i�CR — 0 RECEIVED O MAR 21 2018 CE7daiF1E® ST, Lucl9 county, Permitting .` Ariel Lopez TAB Contractor I�IGB� BNAA SMACNA ��4Ax9lP7He m. C FAN Captive Air DU85HFA Centrifugal Upblast FAN MOTOR DATA Captive Air 115/1 1 6.1 1490 MOTOR PULLEY 8.9" 1" OK FAN PULLEY DATA 8.96 1" OK )P AIR REPORT DATE 3/3/2018 PROJECT Villa Pagano Restaurant M SYSTEM Kitchen Hood HEF-1, HSF-1 1 1 1490 1452 30.40 30.40 980 969 Anal 995 =I JOB NUMBER 937 0.93 r r 1347 (E UP AIR UNIT son I • Captive Air HOOD STYLE Wall M. Wall M. DEL Al G10 HOOD TYPE 1 OR 2 2 2 'LE Untempered Centri. HOOD DIMENSIONS 48" x 9' 48" x 9' HOOD AREA - SQ. Fr. 36 36 J MOTOR DATA FILTER TYPE Alum. Alum. Captive Air H 115/1 !EXHAUST DUCT 2 IDUCT DIMENSIONS 14 x 14 14 x 14 10.3 IDUCT AREA - SQ. FT. 1.36 1.36 A 1011 IDUCT VELOCITY (FPM) 3060 3060 4 MOTOR PULLEY DATA *OTHER MAKE UP AIR METER 9.7 LOCATION N/A N/A \FT 1" COMMENTS /FIXED OK T AX40 WeIRREVAIISIRM1162 AIR TEMPERATURE 4 FAN PULLEY DATA IALTITUDE METER 8.4 1FT 1" /FIXED OK LAMENTS CONT. Exhaust Dampers were regulated to conform with MAU/HEF 90 margins. Static Pressures remained the same throughout this - rebalancing & no pulley nor belt adjustments were needed. !NG 1.v a.0 Q. L. 0 o Q J t LL LL � tt�0 d 2 � @ N L=OtD •� Q o � _J d a iFG Ill FAN Captive Air DU50HFA Centrifugal Upblast FAN MOTOR DATA Captive Air 115/1 1/2 4.5 1518 MOTOR PULLEY 10.1" 1" OK FAN PULLEY DATA 9.64 V OK CFM DR RPM DRAW RPM 1600 1280 1 1518 30.40 1050 950 1541 1244 1244 297 1 1502 30.40 1037 UP AIR UNIT ' ' r ' • • • • • ` Captive Air HOOD STYLE Wall M. Wall M. =L Al G10 HOOD TYPE (1 OR 2) 2 2 E Untempered Centri. HOOD DIMENSIONS 60" x 7'6" 60" x 7'6" HOOD AREA - SQ. FT. 38 38 MOTOR DATA FILTER TYPE Alum. Alum. Captive Air 115/1 'EXHAUST DUCT 2 DUCT DIMENSIONS 12 x 12 12 x 12 10.3 DUCTAREA-SQ.FT. 1 1 1011 DUCT VELOCITY (FPM) 1600 1600 MOTOR PULLEY DATA*OTHER ETER 9.7" LOCATION N/A N/A T 1" COMMENTS :IXED OK AX40 CORRECTION FACTORS AIR TEMPERATURE FAN PULLEY DATA JALTITUDE ETER 8.4 T 1" 'IXED OK MENTS CONT. Exhaust Dampers were regulated to conform with MAU/HEF SO. margins. Static Pressures remained the same throughout this - rebalancing & no pulley nor belt adjustments were needed. ci uk. v"n.o DATE 3/3/2018 PROJECT Villa Pagano Restaurant Kitchen Hood HEF-2, HSF-1 N O �n m o M Q J LL L LL tr L to �d2 v) lU N t+] = m n o 0 r PACKAGED UNIT MFG American Standard MODEL TSCO60E3 TYPE Roof Top Unit SIZE 5 Tons BLOWER MOTOR HP 1 V/PH 2O8-230/3 FLA 4,2 RPM 1725 GRILLES AND DIFFUSERS W11-YA 1712 Kitchen 1 Diffuser 1 24 X 24 300 284 284 95% -, tchen 2 Diffuser 24 X 24 300 311 311 104% �Iitchen 3 Diffuser 24 X 24 300 264 279 93% Kitchen 4 Diffuser 24 x 24 300 288 288 96% Dry storage 5 Diffuser 24 X 24 85 81 81 95% Dry Storage 6 Diffuser 24 x 24 71 68 68 96% Res storage 7 Diffuser 10 X 20 45 48 42 93% Kitchen 8 Diffuser, 24 a 24 300 290 290 9701, Pizza Display 9 Diffuser 24 x 24 286 280 280 98c/u 1 Total I I 1 1 1987 1 1914 1 1923 1 97% 1 DATE 3/3/2018 PROJECT Villa Pagano Restaurant SYSTEM RTU-1 READINGS BY Ariel JOB NUMBER 1347 CL L. 0 v o Co o L = U w a t M M d v .� Q m n J d Q PACKAGED UNIT MFG American Standard MODEL TSC060E3 TYPE Roof Top Unit SIZE 5 Tons BLOWER MOTOR HP 1 V/PH 2O8-230/3 FLA 4.2 RPM 1725 GRILLES AND DIFFUSERS S. lishwashing 1 Diffuser 24 x 24 205 212 198 97% washing 2 Diffuser 24 X 24 205 190 190 93% quet Rm 3 Diffuser 24 X 24 273 260 260 95% Banquet Rm 4 Diffuser 24 X 24 273 240 262 96% Banquet Rm 5 Diffuser 24 X 24 273 276 276 101% Banquet Rm 6 Diffuser 24 X 24 273 255 255 93% Banquet Rm 7 Diffuser, 24 X 24 273 258 258 95% Banquet Rm 8 Diffuser 24 X 24 273 254 254 93% Total 2048 1945 1953 95% DATE 3/3/2018 PROJECT Villa Pagano Restaurant SYSTEM RTU-2 READINGS BY Ariel JOB NUMBER 1347 CL L. U0 0 v o C�7 oM •V Q U- � L LL lL t m M N? L. `o n co Q n J d Q DACKAGED UNIT MFG American Standard MODEL TSCO60E3 TYPE Roof Top Unit SIZE 5 Tons BLOWER MOTOR HP 1 V/PH 2O8-230/3 FLA 4.2 RPM 1725 r_m GRILLES AND DIFFUSERS 1725 77° Dining 1 Diffuser 1 24 x 24 286 271 271 95% Men 2 Diffuser 24 x 24 165 160 160 97% —A4Nomen 3 Diffuser 24 x 24 217 223 223 103% Hall 4 Diffuser 24 x 24 217 183 205 94% Pima Display 5 Diffuser 24 x 24 286 276 276 97% Pia Display 6 Diffuser 24 x 24 286 274 274 96% Dining 7 Diffuser 24 x 24 286 280 280 98°/. Dlnina 8 Diffuser 24 x 24 286 291 291 102% 1 Total I I 1 1 2029 1 1958 1 1980 1 98% 1 DATE 3/3/2018 PROJECT Villa Pagano Restaurant SYSTEM RTU-3 READINGS BY Ariel JOB NUMBER 1347 L O U cq as 0 `I o m \V Q J L t_ l w L M M� L n .� co r J d 06 Q HVAC AIR DIAGNOSTICS REPORT DATE 3/3/2018 PACKAGED UNIT ■ y Air CFM 2002 1926*96%PROJECT MFG American StandardrReturn MODEL TSCOfi0E3 Air CFM 1674 1604 TYPE Roof Top Unit de Air CFM 328 322Villa Pagano Restaurant SIZE 5 Tons peed 1725 1718 BLOWER MOTOR SYSTEM HP 1 �VSTEM PRESSURES V/PH FLA 208-230/3 4.2 1Static Pressure Sup I (+) Static Pressure Retum (-) 0.89 — 0.00 RTU-4 RPM 1725 Total Static Pressure 0.99 Filter Static Pressure 0.1 READINGS BY Temperature In 72" 72° Temperature Out 77• 77° Ariel Drop/Rise 5" 5' JOB NUMBER 1347 GRILLES AND DIFFUSERS Entry 1 Diffuser I 24 x 24 286 281 281 98% Entry 2 Diffuser 24 x 24 286 264 264 92% +lining 3 Diffuser 24 x 24 286 293 293 102% Dining 4 Diffuser 24 x 24 286 275 275 96% Dining 5 Diffuser 24 x 24 286 253 277 97% Dining 6 Diffuser 24 x 24 286 271 271 95% Dining 7 Diffuser 24 x 24 286 265 265 93% Total I I 1 1 2002 1 1902 1 1926 1 96% 1 Q. L UN o ro Qu- m =u w M'- 1.1.1 L •� Q m r J d 06 a Restaurant 5toragc � tv.zr word f w W.M. Decrm �latton ` K-11-1 Vr %=Ue& V fvm bona rwdle KAD-'F-Wwl*In B("rd moletwe Wrier IeOM Nun etorefromw"IftwC OWZIg lne. WIM rnew w MonclmWo a[= mreiewt T Entry coal 4ct� Nr Fbr \4y�y� Duct Turn -out Detail m 7 AMA= a6wlol nN InN�Wn tb JD w Owdcrn w ..aC Nwn rFrM !. r A & L AirBalance Corp. THE BEST DIGITAL PRECISION �i 7345 W 4 Ave. # 405 Hialeah Fl33014 Phone: (305) 962 5863 INSTRUMENTS CALIBRATION INSTRUMENTS APLICATION MODEL CERT. O CALIBRATION Digital Hood AccuBalance CFM 8371 08/15 Spicrometer Meterman RH & Temp. TRH22 06/15 Dif. Manometer Extech S.P. & T.P. 406800 08/15 Laser Tachometer Extech RPM 461923 08/15 Digital Air Flow Supco FPM AB53626 08/15 Leak Detector CPS Leak LS790B 08/15 Laser Thermometer Amprobe Temp. LTP-1 07/15