Loading...
HomeMy WebLinkAboutREVIEW COMMENTSe - Address: 203 Southland Dr Units A-D City / State / Zip: Fort Pierce, FI 34982 Parcel#: 2427-801-0108-100/4 Zoning: RM-11 APPLICATION INFORMATION Permit Number: 1709-0046 Permit Type: COMMERCIAL RENOVATION CONTRACTOR INFORMATION Contractor Name: Robert J Maddox Business Name: Rj Maddox & Associates Inc < Business Addr: 624 Nw Palm St City / State / Zip: Stuart, FI 34994 REVIEWS AND COMMENTS SCANNED BY REVIEW COMMENTS 1. Lucie County Owner(s): Rpm Realty Uc Jurisdiction: SAINT LUCIE COUNTY Lot#: 8 Block: 8 Stories: my OCT 19 ED ReviewTv Status Reviewed By Data Started DOCUMENTS MISSING PENDING Angela Huff 9/512017 9/5/2017 Comment: RECORDED NOTICE OF COMMENCEMENT Comment: NEED ROOF, ELECTRIC, MECHANICAL AND PLUMBING SUBS. 9/5/2017 9/19117: RECEIVED MECHANICAL SUB. 9/22/17: RECEIVED ELECTRICAL SUB. 9/26/17: RECEIVED ROOFING SUB. Automatic Sprinkler System? No Number: 772-232-4870 Maddoxrj@Yahoo.Com Date Completed Date Released FIRE DEPARTMENT REVIEW PENDING Tony Jerger Comment: FRONT COUNTER REVIEW COMPLETE Angela Huff 9/512017 9/5/2017 915/2017 Comment: PLANS EXAMINER ELECTRIC INCOMPLETE Walter Pride 911412017 Comment: SMOKE DECTECTOR TO CODE IN ALL UNITS FLOORS 1 AND 2 AND LAUNDRY ROOM,CORRECTIONS NEEDED ON ELECTRICAL PANELS,ALL WIRING TO CODE,INCLUDING G.F.C.I.RECPS.ELECTRICAL PANEL TO 9/29/2017 HAVE PROPER SIZED FEEDERS. PLANS EXAMINER MECHANICAL INCOMPLETE Carl Peterson Comment: PLANS EXAMINER PLUMBING COMPLETE Greg Smyth 911412017 10/1012017 10/10/2017 Comment: REVIEW COMMENTS PLANS EXAMINER REVIEW INCOMPLETE Joe Cicio 9/1412017 9/1412017 Comment: ROOF TRUSS LAYOUTS FROM THE MANUFACTURER MUST BE REVIEWED AND APPROVED BY THE DESIGN PROFESSIONAL OF RECORD Comment: ROOF TRUSS LAYOUTS ARE SHOWING A BEARING POINT 2'4" OUT TO OUT IN THE FRONT PORCH AREAS' 9/14/2017 THIS DETAIL IS INCORRECTLY SHOWN ON THE APPROVED PLANS [ S-1 ] FRONT WALL THICKNESSES ARE INCONSISTENT BETWEEN THE TRUSS LAYOUTS AND S-1 9/1612017 Comment: THE THOMAS ALBINI SIGNATURES ON THE TRUSS CUT SHEETS MUST BE ORIGINAL FORMAT AND THE ENGINEERING SHEETS MUST BE REVIEWED AND APPROVED BY THE D.P.OF RECORD 9/15/2017 Comment: S-1 STATES GABLE END BRACING PER SHEET D-2' THIS IS NOT IN THE PLAN SETS 9/1612017 Comment: 8-1 CONNECTOR SCHEDULE CONTAINS CONNECTORS WHICH ARE NOT ON THE PLANS' PLEASE REMOVE ALL CONNECTORS AND I.D'S WHICH DO NOT APPLY TO THIS PROJECT 9/15/2017 Comment: ARCHITECT TO DESIGN A GABLE END DETAIL ON PLANS' SHOW ALL SUB -SHEATHING W- ATTACHMENTS, WEATHER BARRIERS AND FINISH DETAILS W/ TESTING STANDARDS 9/15/2017 Comment: SHOW THE ATTIC VENTILATION ON PLANS PER FBC 1203.2 9/15/2017 Comment: ARCHITECT TO DESIGN THE SOFFIT SYSTEM ON PLANS' FBC 1604.2' SUBMIT CORRESPONDING PRODUCT APPROVALS IN DUPLICATE 9/15/2017 Comment: THERE ARE FRAME SECTIONS ON THE FRONT WHICH ARE NOT SHOWN ON PLANS' FBC 1604.2 Comment: SUBMIT [2 ] ST LUCIE COUNTY " PRODUCT REVIEW AFFIDAVITS " COMPLETELY FILLED OUT W/ ORIGINAL 9/15/2017 SIGNATURE, SEAL AND DATED BY YOUR DESIGN PROFESSIONAL' ARCHITECT TO SELECT THE EXACT CLADDING YOU ARE PROPOSING ON AFFIDAVIT NOT ALL TESTED ITEMS 9/16/2017 Comment: IDENTIFY THE "ROLLED ROOFING "ON THE PRODUCT REVIEW AFFIDAVIT WITH CURRENT PRODUCT APPROVAL NUMBERS 9/15/2017 Comment: ARCHITECT TO CLARIFY THE NOTE ON S-1 FOR THE FURRING OF THE GABLE ENDS' NOTE IS CONFUSING 9/1512017 Comment: SUBMIT DUPLICATE, LEGIBLE, MECHANICAL DUCT LAYOUTS CORRESPONDING WITH THE MANUAL D'S 9/15/2017 Comment: ARCHITECT TO DESIGN THE GYP BOARD METHOD OF ATTACHMENT ON PLANS PER THE LISTED TESTING STANDARDS IN FBC 2506.2 FOR ALL GYP APPLICATIONS Comment: PLEASE NOTE THAT THE COMMENTS ARE FOR THE CLARIFICATION OR CORRECTION OF THE SUBMITTED DOCUMENTS. ADDITIONAL REVIEW MAY BE REQUIRED AFTER SUBMITTING CORRECTED DOCUMENTS PLEASE NOTE: (1) ALL REVIEW COMMENTS WHEN ANSWERED WILL REQUIRE COVER LETTER ADDRESSING WHERE THE CHANGES WERE MADE, (2) ALL CHANGES WILL BE REQUIRED TO BE CLOUDED 10/2/2017 ON THE PLANS AND (3) THE CONTRACTOR WHEN RESUBMITTING WILL BE REQUIRED TO INSERT THE NEW UPDATED PAGES INTO THE PLANS OR IF THE CONTRACTOR PREFERS, A REVISED COMPLETE SET OF PLANS CAN BE SUBMITTED PLEASE NOTE ANY COMMENT NOT ADDRESED MAY BE SUBJECT TO AN ADDITIONAL REVIEW FEE PER ST. LUCIE COUNTY RESOLUTION #13-196 COMMENTS SENT 10/212017 Comment: COMMENTS E-MAILED AS OF THIS DATE" PENDING MECHANICAL REVIEW