Loading...
HomeMy WebLinkAboutENERGY CONSERVATION CHECK LISTFlorltla Btailding.Code, Fifth Edition (2014) 2Energy'.,Conservatlon, EnergyGauge Summit® FIa/Com-2015,: Effective -,Date June 30, 2015 �« IECC 2012 Total;Butlding;Performance Compliance Option s Check List SCANNED Qf By Applications for compliance with the Florida Building Code, EneJyLQoiLflsWation shall include: sty ❑ This Checklist ❑ An Input report generated from the software just after completing compliance calculations without any further changes ❑ The full compliance report generated by the software that contains the project summary, complaince summary, certifications and detailed component compliance reports ❑ Boxes appropriately checked in the Miscellanous report generated by the software at the end of the compliance report Qoa®asc�ceeeo S1/pBOs�s Po ye s V • � e s� � 1 T •�e' I. T •..P e �� S+ . R i \Vp �o ONAL EnergyGauge Summit® Fla/Com-2014. TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 6/16/2017 Page 1 of 13• PROJECT SUMMARY Short Desc: Geriatric Solutions Description: Geriatric Solutions Owner: Geriatric Solutions Addressl: 5804 Indian Pines Blvd. City: Fort Pierce Address2: State: FL Zip: 34951 Type: Healthcare -Clinic Class: Renovation to existing Jurisdictjon: FORT PIERCE, ST LUCIE COUNTY, FL (661100) Conditioned' Area: 1400 SF Conditioned & UnConditioned Area: 1400 SF No of Stories:;-] Area entered from Plans 0 SF Permit No: 0 Max Tonnage 5 If different, write in: Component Design Criteria Result Gross Energy Cost (in $) 1,026.0 1,151.0 PASSED LIGHTING CONTROLS EXTERNAL LIGHTING HVAC SYSTEM PLANT WATER HEATING SYSTEMS PIPING SYSTEMS Met all required compliance from Check List? PASSES PASSES PASSES No Entry PASSES No Entry Yes/No/NA IMPORTANT MESSAGE Info 5009 -- -- -- An' input report of this design building must be submitted along with this Compliance Report EnergyGauge Summit® Fla/Com-2014. TAM 2014-1.0 Compliant Software. Effective Date: -'June 30, 2015 6/16/2017 Page 2 of 13 1. S CERTIFICATIONS I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code Prepared By: Eric J.Svoboda,�PfE Building Official: Date: 6 11 r / �— Date: I certify that this building is in compliance with the FLorida Energy Efficiency Code Owner Agent: Date: If Required by Florida law, I hereby certify (*).that the system design is in compliance with the Florida Energy Efficiency Code Architect: Reg No: Electrical Designer: Reg No: Lighting Designer: Reg No: Mechanical Designer: Reg No: Plumbing Designer: Reg No: (*) Signature is required where Florida Law requires design to be performed by registered design professionals. Typed names and registration numbers may be used where all relevant information is contained on signed/sealed plans. EnergyGauge Summit® Fla/Com-2014. TAM 20144.0 Compliant Software. Effective DateAune 30, 2015 ;, 6/16/2017 Page 3 of 13 Project: Geriatric Solutions Title: Geriatric Solutions Type: Healthcare -Clinic Total 1) Proposed 2) Baseline 65.90 86.80 $1,026 $1,354 ELECTRICITY(MBtulkWhl$) 65.90 86.80 19280 25404 $1,026 $1,354 AREA LIGHTS 16.50 24.90 4820 7288 $256 $388 MISC EQUIPMT 21.00 21.00 6153 6153 $327 $328 PUMPS & MISC 0.00 0.10 8 23 $0 $1 SPACE COOL 18.00 17.80 5266 5215 $280 $278 SPACE HEAT 0.30 1.10 83 320 $4 $17 VENT FANS 10.10 21.90 2950 6405 $157 $341 Credits Applied: None PASSES Passing Criteria =1151 Design (including any credits) =1026 Passing requires Proposed Building cost to be at most 85% of Baseline cost. This Proposed Building is at 75.8% `EnergyGauge'SummM Fla/Com-2014.'TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015 6/16/2017 Page 4 of 13 Project: Geriatric Solutions Title: Geriatric Solutions Type: Healthcare -Clinic (WWEA File: DAYTONABEACH.TMY) External Lighting Compliance Description Category Tradable? Allowance Area or Length ELPA CLP (W/Unit) or No. of Units (W) (W) (Sgft or ft) Ext Light 1 Main entries Yes 30.00 3.0 90 60 Ext Light 2 Other (doors) than main entries Yes 20.00 3.0 60 60 Ext Light 3 Building facades (by linear foot) No 5.00 152.0 760 480 Tradable Surfaces: 120 (W) Allowance for Tradable: 900 (W) PASSES All External Lighting: 600 (W) Complicance check includes a excess/Base allowance of 750.00(W) Project: Geriatric Solutions Title: Geriatric Solutions Type: Healthcare -Clinic (WEA File: DAYTONABEACH.TMY) Lighting Controls Compliance Acronym Ashrae Description Area Design Min Compli- ID (sq.ft) CP CP ance PrOZo1Sp1 10,004 Exam/Treatment (Hospital) 1,400 1 1 PASSES PASSES EnergyGauge Summit® Fla/Com-2014: TAM 20141.0 Compliant Software. Effective Date:,June 30, 2015 :, 6/16/2017 ..Page 5 of 13 Project: Geriatric Solutions Title: Geriatric Solutions Type: Healthcare -Clinic (WEAFile: DAYTONABEACH.TMY) System Report Compliance PrOSyl System 1 Constant Volume Air Cooled No. of Units Split System < 65000 Btu/hr 1 Component Category Capacity Design Eff Design IPLV Comp- Eff Criteria IPLV Criteria ►iance Cooling System Air Conditioners Air Cooled 60000 15.50 12.23 8.00 PASSES Split System < 65000 Btu/h Cooling Capacity Heating System Electric Furnace 31000 1.00 1.00 PASSES Air Handling Air Handler (Supply) - 1800 0.40 0.82 PASSES System -Supply Constant Volume Air Distribution ADS System (Sup) 6.00 3.50 PASSES System (Sup) Air Distribution ADS System (Ret) 6.00 PASSES System (Ret) PASSES Plant Compliance Description Installed Size Design Min Design No Eff Eff IPLV Min Category Comp IPLV liance None EnergyGauge Summit® Fla/Com-2014. TAM 2014-1'.0 Compliant Software. Effective Date: June 30, 2015 6/16/2017 Page 6 of 13 Project: Geriatric Solutions Title: Geriatric Solutions Type: Healthcare -Clinic (WEAFile: DAYTONABEACH.TMY) Water Heater Compliance Description Type Category Design Min Eff Eff Design Max Comp Loss Loss liance Water Heater 1 Electric water heater <= 12 [kW] 0.95 0.93 PASSES PASSES Piping System Compliance Category Pipe Dia Is Operating Ins Cond Ins Req Ins Compliance [inches] Runout? Temp [Btu-in/hr Thick [in] Thick [in] [F] SF.F] None EnergyGauge Summit@.Fla/Com-2014. TAM 2014-1.0 Compliant.Software. Effective Date: June 30, 2015 6/16/20.17 Page 7,of 13 HVAC C403.2.8.1 Mechanical Piping Insulation exposed to weather is protected .._ from damage (due to sun, moisture, wind, etc.). HVAC C403.2.7 Mechanical HVAC ducts and plenums insulated. Where ducts 0❑ or plenums are installed in or under a slab, verification may need to occur during Foundation Inspection. HVAC C403.2.8 ' Mechanical Thermally ineffective panel surfaces of sensible ❑ heating panels have Insulation >= R-3.5. HVAC C403.2.7 Mechanical Ducts and plenums sealed based on static ❑ ❑ pressure and location. HVAC C408.2.2.1 Mechanical Air outlets and zone terminal devices have means ❑ 13 ❑ for air balancing. HVAC C403.2.6 Mechanical Exhaust air energy recovery on systems meeting 0❑ Table C403.2.6 HVAC C403.2.11 Mechanical Unenclosed spaces that are heated use only radiant heat. HVAC C403.2.4.1 Mechanical Heating and cooling to each zone is controlled by ❑ ❑ a thermostat control. HVAC C403.2.4.2 Mechanical Thermostatic controls have a 5 °F deadband. ❑ HVAC C403.2.4.2 Mechanical Temperature controls have setpoint overlap 13 ❑ ❑ restrictions. HVAC C403.2.4.3 Mechanical Each zone equipped with setback controls using automatic time clock or programmable control system. HVAC C403.2.4.3 Mechanical Automatic Controls: Setback to 55°F (heat) and 13 13 ❑ 85°F (cool); 7-day clock, 2-hour occupant override, 10-hour backup SYSTEM_SPECIFIC C404.3 Mechanical Temperature controls installed on service water 13 ❑ 13 heating systems (110 OF for dwelling units and lavatories in public restrooms and 90 OF for other occupancies.) SYSTEM_SPECIFIC C404.4 Mechanical Automatic time switches installed to automatically 13 ❑ switch off the recirculating hot-water system or heat trace. SYSTEM_SPECIFIC C404.2 Mechanical Heat traps installed on non -circulating storage 13 ❑ ❑ water tanks. SYSTEM_SPECIFIC C403.2.3 Mechanical PTAC and PTHP with sleeves 16 in. by 42 in. labeled for replacement only as per Footnote b to Table C403.2.3(3). SYSTEM SPECIFIC C403.4.2 Mechanical VAV fan >= 7.5 hp are driven by mechanical or El ❑ electrical variable speed drive, or.driven by vane -axial with variable speed blades,.or operate with motor demand <=30% design kW at 50% design flow - calculations required SYSTEM_SPECIFIC C403.2.8 Mechanical HVAC piping insulation thickness. Where piping is installed in or under a slab, verification may need to occur during Foundation Inspection. SYSTEM_SPECIFIC C403.2.7.1.3 Mechanical Ductwork operating >3 in. water column requires air leakage testing. SYSTEM SPECIFIC C403.3.1,C403.3.1.1 Mechanical Air economizers provided where required, meet the requirements for design capacity, control signal, ventilation controls, high -limit shut-off, integrated economizer control, and provide a means to relieve excess outside air during operation. SYSTEM_SPECIFIC C403.3.1,C403.4.1 Mechanical Water economizers provided where required, 11130 meet the requirements for design capacity, maximum pressure drop and integrated economizer control. SYSTEM SPECIFIC C403.4.1.4 Mechanical Economizer operation will not increase heating 13110 energy use during normal operation. SYSTEM SPECIFIC C403.4.5 Mechanical Zone controls can limit simultaneous heating and ❑ cooling and sequence heating and cooling to each zone. SYSTEM_SPECIFIC C403.4.3.1 Mechanical Three -pipe hydronic systems using a common return for hot and chilled water are not used. EnergyGauge Summil® Fla/Com-2014. TAM 2014-1.0 Compliant Software: Effective Date: June 30, 2015 6/16/2017 Page 10 of 13 0 SYSTEM —SPECIFIC C403.4.3.2 Mechanical Two -pipe hydronic systems using a common distribution system have controls to allow a deadband >=15 OF, allow operation in one mode for at least 4 him before changeover, and have rest controls to limit heating and cooling supply temperature to <=30 OF. SYSTEM —SPECIFIC C403.4.3.3.1 Mechanical Hydronic heat pump systems connected to a ❑ common water loop meet heat rejection and heat addition requirements. SYSTEM —SPECIFIC C408.2.2.2 Mechanical HVAC hydronic heating and cooling coils have ❑ E3 ❑ means to balance and have pressure test connections. SYSTEM SPECIFIC C403.2.10.1 Mechanical HVAC fan systems at design conditions do not exceed allowable fan system motor nameplate hp or fan system bhp. SYSTEM SPECIFIC C403.2.10.2 Mechanical HVAC fan motors not larger than allowable limits. ❑ SYSTEM SPECIFIC C403.4.2 Mechanical VAV fan motors >=7.5 hp to be driven by variable speed drive, have a vane -axial fan with variable pitch blades, or have controls to limit fan motor demand. SYSTEM —SPECIFIC C403.4.2.1 Mechanical VAV fans have static pressure sensors positioned ❑ 13 so setpoint <=1/3 total design pressure. SYSTEM —SPECIFIC C403.4.2.2 Mechanical Reset static pressure setpoint for CDC controlled ❑ 0 El VAV boxes reporting to central controller based on the zones requiring the most pressure. SYSTEM_SPECIFIC C403.4.5.4 Mechanical Multiple zone HVAC systems have supply air 0 0❑ temperature reset controls. SYSTEM C403.4.3.4 Mechanical Hydronic systems greater than 300,000 Bluth —SPECIFIC designed for variable fluid flow. SYSTEM SPECIFIC C403.4.3.5 Mechanical Reduce flow in pumping systems >10 hp to El El ❑ multiple chillers or boilers when others are shut down. SYSTEM —SPECIFIC C403.4.3.4 Mechanical Temperature reset by representative building ❑ El El loads in pumping systems for chiller and boiler systems >300,000 Btu/h. SYSTEM SPECIFIC C403.4.3.3.3 Mechanical Two -position automatic valve interlocked to shut ❑ off water flow when hydronic heat pump with pumping system >10 hp is off. SYSTEM SPECIFIC C403.4.4 Mechanical Fan systems with motors >=7.5 hp associated with heat rejection equipment to have capability to operate at 2/3 of full -speed and auto speed controls to control the leaving fluid temperature or condensing temp/pressure of heat rejection device. SYSTEM —SPECIFIC C403.4.6 Mechanical Condenser heat recovery system that can heat D U❑ water to 85 OF or provide 60% of peak heat rejection is installed for preheating of service hot water in 24/7 facility, water cooled systems reject >6 MMBtu, SHW load >=1 MMBtu. SYSTEM —SPECIFIC C403.4.7 Mechanical Hot gas bypass limited to: ❑ ❑ ❑ <=240 kBtu/h — 50% >240 kBtu/h —25% SYSTEM —SPECIFIC C404.2 Mechanical Service water heating equipment meets efficiency ❑ ' requirements. SYSTEM SPECIFIC C403.2.4.2 Mechanical Heating and cooling to each zone is controlled by 13 ❑ IJ a thermostat control. Minimum one humidity control device per installed humidification/dehumidification system. SYSTEM —SPECIFIC C403.2.4.3.3 Mechanical Systems include optimum start controls. . SYSTEM C403.2.4.1.1 Mechanical Heat pump controls prevent supplemental electric —SPECIFIC resistance heat from coming on when not needed. SYSTEM -SPECIFIC C404.3 -- "-Mechanical---=Public lavatory -faucet water -temperature <=110°F. SYSTEM SPECIFIC C404.5 Mechanical All piping in circulating system insulated SYSTEM_SPECIFIC C404.5 Mechanical First 8 it of outlet piping is insulated ' 1311 .EnergyGauge Summit® Fla/Com-2014. TAM 2014-1.0 Compliant Software. Effective Date.,June 30, 2015 . 6/16/2017 Page I of 13 Project Name: Geriatric Solutions Project Title: Geriatric Solutions Address: 5804 Indian Pines Blvd. State: FL Zip: 34951 Owner: Geriatric Solutions EnergyGauge Summit® v5.10 Proiect Information Orientation: North Biding TYpe: Healthcare -Clinic Building Classification: Renovation to existing building No.of Stories: 1 GrossArea: 1400 SF Zones No Acronym Description- Type Area [sf] Multiplier Total Area [sf] 1 PrOZol Zone 1 CONDITIONED 1400.0 1 1400.0 ❑ Spaces No Acronym Description Type Depth IN Width Height Multi [ft] [ft] plier Total Area [st] Total Volume [cf] 6/16/2017 EnergyGauge Summit® v5.10 1 jffne,PrOZoI 40.00 9.00 1 1400.0 12600.0 PrOZa1Sp1 Zo0Sp1 Exam/Treatment(Hospital) 35.00 { Lighting No Type Category No. of Watts per Power Control Type No.of Luminaires Luminaire [W] Ctrl pts In Zone: PrOZol In Space: Pr0Zo1Sp1 I Compact Fluorescent General Lighting 1 1574 1574 Occupancy sensor without 1 ❑ Daylighting Walls No Descript ion Type Width H (Elfec) Multi Area DirectionConductance Heat Dens. R-Value [it] [ft] plier [sf] [Btu/hr. sf. F] Capacity [lb/cf] [h.sf.FBtu] [Btu/sf.F] In Zone: J PrOZol I PrOZolWal 5/8" stucco 40.00 10.00 1 400.0 NorthEast 0.2067 5.731 34.65 4.8 ❑ /8"CMU/3/4"ISO BTWN24"oc/.5" Gyp 2 PrOZo1 va? 518" stucco 39.00 10.00 1 390.0 SouthEast 0.2067 5.731 34.65 4.8 ❑ /8"CMU/3/4"ISO BTWN24"oe/.5" Gyp 3 PrOZolWa3 5/8" stucco 40.00 10.00 1 400.0 SouthWes 0.2067 5.731 34.65 4.8 ❑ /8"CMU/3/4"ISO t BTWN24"oc/.5" Gyp 4 PrOZolWa4 5/8" stucco 39.00 10.00 1 390.0 NorthWes 0.2067 5.731 34.65 4.8 ❑ /8"CMU/3/4"ISO t BTWN24"oc/.5" Gyp 6/16/2017 EnergyGauge•Summitg v5.10 Windows No Description Type Shaded U SHGC Vis.Tra W H(Effec) Multi Total Area [Btu/hrsfF] IN [ft] plier [s1] In Zone: PrOZol In Wall: South East 1 PrOZolWa2Wil UserDefined No 1.2500 0.82 0.76 2.00 6.00 2 24.0 In Wall: South West 1 PrOZolWa3Wil UserDefined No 1.2500 0.82 0.76 2.00 6.00 3 36.0 2 PrOZolWa3Wi2 User Defined No 1.2500 0.82 0.76 6.00 6.00 2 72.0 Doors No Description Type Shaded? Width H (Effec) Multi Area Cond. Dens. Heat Cap. R-Value [ft] [ft] plier [sf] [Btu/hr. sf. F] [lb/ci] [Btu/sf. F] [h.sf.F/Btu] In Zone: PrOZol Iu Wall: North East I PrOZol Wa1Drl Solid core flush No 3.00 7.00 1 21.0 0.3504 0.00 0.00 2.85 ❑ (2.25) In Wall: South West 1 PrOZol Wa3Drl Solid core flush No 3.00 7.00 1 21.0 0.3504 0.00 0.00 2.85 ❑ (2.25) Roofs No Description Type Width H (Effec) Multi Area Tilt Cond. Heat Cap Dens. R-Value [ft] [ft] plier [sf] [deg] [Btu/hr. SE F] [Btu/sE F] [lb/cf] [h.sEFBtu] In Zone: Pr1Zol I PrOZolRfl Mtl Bldg Roof/R-19 40.00 35.00 1 1400.0 0.00 0.0492 1.34 9.49 20.3 ❑ Batt ' 6/16/2017 EnergyGauge Summit® v5,10 Skylights No Description Type U SHGC Vis.Trans W H(Effec) Multiplier [Bm/hr sf F] [ft] [ft] Area TotalArea [Sf] [S11 In Zone: In Roof: Floors No Description Type Width H(Effec) Multi Area Cond. Heat Cap. Dens. [ft] [ft] plier [st] [Btu/hr. sf. F] [Btu/sf. F] [lb/ct] R-Value [h.st.F/Btu] I In Zone: PrOZol 1 Pi0Zo1F11 1 ft. soil, concrete floor, carpet and rubber pad 40.00 35.00 1 1400.0 0.2681 -34.00 113.33 3.73 ❑ Systems PrOSyl System 1 Constant Volume Air Cooled Split No. Of Units 1 System < 65000 Btu/hr Component Category Capacity Efficiency H'LV I Cooling System 2 Heating System 3 Air Handling System -Supply 4 Air Distribution System (Sup) 5 Air Distribution System (Ret) 60000.00 15.50 8.00 31000.00 1.00 1800.00 0.40 6.00 6.00 ❑ ❑ ❑ ❑ ❑ Plant Equipment Category i Size Inst.No Eff. 1PLV 6/16/2017 EnergyGauge Summit® v5.10 71 Water Heaters W-Heater Description Capacit3Cap.Unit I/P Rt. Efficiency Loss 1 Electric water heater 30 [Gal] 5 [M] 0.9500 [Ef] [Btu/h] ❑ Ext-Lighting Description Category No. of Watts per Area/Len/No. of units Control Type Wattage Luminaires Luminaire [sf/ft/No] [W] 1 Ext Light I Main entries 1 60 3.00 Photo Sensor control 60.00 ❑ 2 ExtLight2 Other(doors)than main 1 60 3.00 Photo Sensor control 60.00 ❑ entries 3 Ext Light 3 Building facades (by linear 4 120 152.00 Photo Sensor control 480.00 ❑ foot) Piping Operating Insulation Nomonal pipe Insulation Is Runout? No Type Temperature Conductivity Diameter Thickness [F] [ Btu-in/h.sf.F] [in] [in] Fenestration Used Name Glass Type No. of Glass SHGC VLT Panes Conductance (Btu/h.sLF] ASHULSg1C1rAl User Defined I 1.2500 0.8200 0.7600 ❑ 1Frm 6/16/2017 EnergyGauge Summit® v5.10 5 s Materials Used Only R-Value RValue Thickness Conductivity Density SpecificHeat Mat No Acronym Description Used [h.sEFBtu] [ft] [Btu/h.ft.F] [Ib/cI] [Btu/Ib.F] 187 at o BOARD,1/21N 178 Mat1178 CARPET W/RUBBER PAD Yes 1.2300 ❑ 265 Mat1265 Soil, 1 ft No 2.0000 1.0000 0.5000 100.00 0.2000 ❑ 48 Matl48 6 in. Heavyweight concrete No 0.5000 0.5000 1.0000 140.00 0.2000 ❑ 268 Mat1268 0.625" stucco No 0.1302 0.0521 0.4000 16.00 0.2000 ❑ 42 Matl42 8 in. Lightweight concrete No 2.0212 0.6670 0.3300 38.00 0.2000 ❑ block 269 Mat1269 .75" ISO BTWN24" oc No 2.2321 0.0625 0.0280 4.19 0.3000 ❑ 23 Ma63 6 in. Insulation No 20.0000 0.5000 0.0250 5.70 0.2000 ❑ 94 Matl l4 BUILT-UP ROOFING, No 0.3366 0.0313 0.0930 70.00 0.3500 ❑ 3/81N Constructs Used Simple Massless Conductance 'Heat Capacity Density RValue No Name Construct Construct [Btu/h.sEF] [Btu/SEF] [lb/cI] [h.sEFBtu] 1011 5/8" stucco /8"CMU/3/4"ISO No No 0.21 5.73 34.65 4.8 ❑ BTWN24"oc/.5" Gyp Layer Material Material Thickness Framing No. [ft] Factor 1 268 0.625" stucco 0.0521 0.000 ❑ i 2 42 8 in. Lightweight concrete block 0.6670 0.000 ❑ 3 269 .75" ISO BTWN24" oc 0.0625 0.000 ❑ 4 187 GYPORPLASBOARD,1/2IN 0.0417 0.000 ❑ 6/16/2017 1 EnergyGauge-Summit® v5.10 No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] [Btu/sf.F] [Ib/cf] [h.sf.FBtu] 1056 Mtl Bldg Roof/R-19 Batt No No 0.05 1.34 9.49 20.3 ❑ Layer Material Material Thickness Framing No. IN Factor 1 94 BUILT-UP ROOFING, 3/81N 0.0313 0.000 ❑ 2 23 6 in. Insulation 0.5000 0.000 ❑ Simple Massless Conductance Heat Capacity Density RValue No Name Construct Construct [Btu/h.sf.F1 [Btu/sf.F] [Ib/cf] [h.sf.F/Btu1 1057 1 ft. soil, concrete floor, carpet and rubber No No 0.27 34.00 113.33 3.7 ❑ pad Layer Material Material Thickness Framing No. [ft] Factor 1 265 Soil, 1 ft 1.0000 0.000 ❑ 2 48 6 in. Heavyweight concrete 0.5000 0.000 ❑ 3 178 CARPET W/RUBBER PAD 0.000 ❑ No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] [Btu/sf.F1 [Ib/cf] [h.sf.F/Btu] 1058 Solid core flush (2.25) No Yes 0.35 2.9 ❑ Layer Material Material Thickness Framing No. [ft] Factor 1- 279 Solid core flush (2.25") 0.000 ❑ 6/16/2017 EnergyGauge Summit® v5:10 7