Loading...
HomeMy WebLinkAboutREVIEW COMMENTSmac. �s.ritri liosrnZi-z \� Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue.. Fort Pierce, FL U982 Phone:(772)462.2172 Fax:(772)462.6443 Address: 5804 Indian Pine Blvd City / State / Zip: Fort Pierce, FI 34951 Parcel#: 1312-110-0101-010/0 Zoning: CO APPLICATION INFORMATION Permit Number: 1707-0529 Permit Type: COMMERCIAL ADDITION REVIEW COMMENTS SC BONED SL Lucie rMgn Owner(s): Madetric N Wood Jurisdiction: ST LUCIE COUNTY Lot#: Block: Stories: Automatic Sprinkler System? No Contractor Name: Ramses Rodriguez Fax Number: 772-336-6486 Business Name: Tri - R Construction Company Inc Email: Ramsesrdguez@Hotmail.Com ,Business Addr: 1457 Sw Prairie Cir City / State / Zip: Port St Lucie, FI 34953 REVIEWS AND COMMENTS Review Type Status Reviewed By Date Started Date Completed Date Released DOCUMENTS MISSING PENDING Karen Nielsen 7125/2017 7/2512017 Comment: RECORDED NOC 7/2512017 Comment: ELECTRICAL SUB 7/2512017 Comment: PLUMBING SUB 7/25/2017 Comment: MECHANICAL SUB 7/25/2017 Comment: ROOFING SUB 10/5/2017 Comment: DRIVEWAY APPLICATION FOR CONNECTION TO THE ROAD. ENGINEERING DEPARTMENT PENDING 10/4/2017 Comment: DROPPED OFF A SET OF PLAN FOR EDMUND BAS TO REVIEW. FIRE DEPARTMENT REVIEW PENDING Tony Jerger Comment: FRONT COUNTER REVIEW COMPLETE Karen Nielsen 7/2512017 712512017 712512017 Comment: PLANS EXAMINER ELECTRIC COMPLETE Walter Pride 8/29/2017 9/5/2017 9/512017 Comment: PLANS EXAMINER MECHANICAL COMPLETE Carl Peterson 10I2I2017 10/212017 Comment: Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:(772)462-2172 Fax:(772)462-6443 REVIEW COMMENTS Page 2 PLANS EXAMINER PLUMBING INCOMPLETE Gren 3mvfh e1?a1qm7 8/2912017 Comment: PLEASE SHOW SERVICE SINK PER TABLE 403.1 OF THE FLORIDA PLUMBING CODE 2014. PLANS EXAMINER REVIEW INCOMPLETE Joe Clcio 8/28/2017 Comment: PLANS AND ENERGY CALCS ARE SPECIFYING C.B.S. CONSTRUCTION "' SITE PLAN SPECIFIES " WOOD 8/28/2017 FRAME COMMERCIAL STRUCTURE— DESIGN PROFESSIONAL TO CHECK SITE AND DESIGN PLANS ACCORDINGLY • PLEASE CORRECT ONE OR THE OTHER 8/28/2017 Comment: SUBMIT TRIPLICATE TRUSS LAYOUTS FROM THE TRUSS MANUFACTURER REVIEWED AND APPROVED BY THE DESIGN PROFESSIONAL OF RECORD Comment: SUBMIT TRIPLICATE, ORIGINAL, SIGNED, SEALED AND DATED TRUSS ENGINEERINGS REVIEWED AND 8/28/2017 APPROVED BY THE DESIGN PROFESSIONAL OF RECORD' PLEASE BE SURE THAT ALL IS COMPLETELY FILLED OUT 8/28/2017 Comment: SHOW THE DETAILS AND LOCATION ON PLANS FOR THE " MALTESE CROSS " PER FAC 69A-60.0081 8/28/2017 Comment: PLEASE SUBMIT A LABOR AND MATERIAL COST BREAKDOWN FOR THE INTERIOR RENOVATIONS AND RAMP • THE ADDITION WILL CALCULATE PER THE [CC VALUATION TABLE 10/5/2017 Comment: PLEASE REMOVE THE SITE DETAIL FROM A-1 • IT IS NOT TO THE SITE PLANS 10/5/2017 Comment: YOU HAVE PROPOSED 60" CORRIDORS' THESE DO NOT SCALE CORRECTLY AND ARE MISSING DIMENSIONS ON PLANS' SEE FBC 107.2.1 / ALL PLANS MUST BE FULLY DIMENSIONED Comment: PLEASE NOTE THAT THE COMMENTS ARE FOR THE CLARIFICATION OR CORRECTION OF THE SUBMITTED DOCUMENTS. ADDITIONAL REVIEW MAY BE REQUIRED AFTER SUBMITTING CORRECTED DOCUMENTS PLEASE NOTE: (1) ALL REVIEW COMMENTS WHEN ANSWERED WILL REQUIRE COVER LETTER ADDRESSING WHERE THE CHANGES WERE MADE, (2) ALL CHANGES WILL BE REQUIRED TO BE CLOUDED 10/5/2017 ON THE PLANS AND (3) THE CONTRACTOR WHEN RESUBMITTING WILL BE REQUIRED TO INSERT THE NEW UPDATED PAGES INTO THE PLANS OR IF THE CONTRACTOR PREFERS, A REVISED COMPLETE SET OF PLANS CAN BE SUBMITTED PLEASE NOTE ANY COMMENT NOT ADDRESED MAY BE SUBJECT TO AN ADDITIONAL REVIEW FEE PER ST. LUCIE COUNTY RESOLUTION #13-196 COMMENTS SENT 10/5/2017 Comment: COMMENTS E-MAILED AS OF THIS DATE ZONING REVIEW INCOMPLETE Lydia Galbraith 8/15/2017 10/4/2017 Comment: FORWARD ONE SET OF PLANS TO ENGINEERING FOR CONSTRUCTABILITY REVIEW. 10/4/2017 Comment: 1014/17 EMAIL TO BABY IN WATER QUALITY TO CHECK IF THEY RECEIVED THE STORM WATER APPL. Planning & Development Services - Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL. 34982 Phone:(7721462-2172 Fax:(772)462.6443 PROPERTY INFORMATION Addressi: 5804 Indian Pine Blvd City / State / Zip: Fort Pierce, FI 34951 Parcel #: 1312-110-0101-010/0 Zoning: CO APPLICiAT10N INFORMATION Permit Mumber: 1707-0529 Permit Type: COMMERCIAL ADDITION CONTRACTOR INFORMATION REVIEW COMMENTS OCT 112017 Stories: 1 7k V1 G�.- Block: Automatic Sprinkler System? No Contractor Name: Ramses Rodriguez Fax Number: 772-336-6486 Business Name: Tri - R Construction Company inc 'Email: Ramsesrdguez@Hotmail.Co Business Addr: 1457 Sw Prairie Cir m City / Stpte / Zip: Port St Lucie, FI 34953 REVIEWS AND COMMENTS Review Type Status Reviewed By Date Started Date Completed Date Released DOCUMENTS MISSING PENDING Karen Nielsen 712512017 7/2$/2017 Comment: RECORDED NOC 7/25/2017 Comment: ELECTRICAL SUB 7/25/2017 Comment: PLUMBING SUB 7/2512017 Comment: MECHANICALSUB 7/25/2017 Comment: ROOFING SUB 10/5/2017 Comment: DRIVEWAY APPLICATION FOR CONNECTION TO THE ROAD. ENGINEERING DEPARTMENT PENDING 10/4/2017 Comment: DROPPED OFF A SET OF PLAN FOR EDMUND BAS TO REVIEW. FIRE DEPARTMENT REVIEW PENDING Tony Jerger Comment: ` FRONT COUNTER REVIEW COMPLETE Karen Nielsen 7125/2017 7/25/2017 7/2512017 Comment: PLANS EXAMINER ELECTRIC COMPLETE Walter Pride 8129/2017 9/5/2017 9/5/2017 Comment: PLANS EXAMINER MECHANICAL COMPLETE Cad Peterson 101212017 101212017 Comment: Planning 8 Development Services Building B Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL. 34982 Phone:(772)462-2172 Fax:(772)462.6443 REVIEW COMMENTS PLANS EXAMINER PLUMBING INCOMPLETE Greg Smyth 812912017 8/29/2017 Comment:l PLEASE SHOW SERVICE SINK PER TABLE 403.1 OF THE FLORIDA PLUMBING CODE 2014. PLANS EXAMINER REVIEW INCOMPLETE Joe Ciclo 8128/2017 Sec Srdi�-z � $cJtS��PC.0 Comment: Z PLANS AND ENERGY CALCS ARE SPECIFYING C.B.S. CONSTRUCTION "' SITE PLAN SPECIFIES' WOOD 8/28/2017 FRAME COMMERCIAL STRUCTURE "' DESIGN PROFESSIONAL TO CHECK SITE AND DESIGN PLAN ACCORDINGLY' PLEASE CORRECT ONE OR THE OTHER 13%3 (LLP((S?6 (lj e a 8/2812017 Comment: 3 SUBMIT TRIPLICATE TRUSS LAYOUTS FROM THE TRUSS MANEFALVoRE�R REVIEWED yC0- AND APPROVED 6V�eN ''/r THE DESIGN' PROFESSIONAL OF RECOR � V' Comment: SUBMIT TRIPLICATE, ORIGINAL, SIGNED, SEALED AND DATED TRUSS ENGINEERINGS REVIEWED AND gVMCB6 8128/2017 I APPROVED BY THE DESIGN PROFESSIONAL OF RECORD • PLEASE BE SURE THAT ALL IS COMPLETELY FILLED OUT 8/28/2017 Comment: 5 SHOW THE DETAILS AND LOCATION ON PLANS FOR THE" MALTESE CROSS " PER FAC 69A-60.0081 8128/2017 Comment: / PLEASE SUBMIT A LABOR AND MATERIAL COST BREAKDOWN FOR THE INTERIOR RENOVATIONS AN J� e �V RAMP' THE ADDITION WILL CALCULATE PER THE ICC VALUATION TABLE Co vA�RAE'.' 1r02—'f>'� Peoul ✓f 10/5/2017 Comment: % PLEASE REMOVE THE SITE DETAIL FROM A-1 IT IS NOT TO THE SITE PLANS 04—) zk 10/512017 Comment: YOU HAVE PROPOSED 60" CORRIDORS' THESE DO NOT SCALE CORRECTLY AND ARE MISSING 4 Z DIMENSIONS ON PLANS • SEE FBC 107.2.1 / ALL PLANS MUST BE FULLY DIMENSIONED Comment 4 PLEASE NOTE THAT THE COMMENTS ARE FOR THE CLARIFICATION OR CORRECTION OF THE SUBMITTED DOCUMENTS. ADDITIONAL REVIEW MAY BE REQUIRED AFTER SUBMITTING CORRECTED DOCUMENTS PLEASE NOTE: (1) ALL REVIEW COMMENTS WHEN ANSWERED WILL REQUIRE A COVER LETTER ADDRESSING WHERE THE CHANGES WERE MADE, (2) ALL CHANGES WILL BE REQUIRED TO BE CLOUDED 1015/2017 ON THE PLANS AND (3) THE CONTRACTOR WHEN RESUBMITTING WILL BE REQUIRED TO INSERT THE NEW UPDATED PAGES INTO THE PLANS OR IF THE CONTRACTOR PREFERS, A REVISED COMPLETE SET OF PLANS CAN BE SUBMITTED PLEASE NOTE ANY COMMENT NOT ADDRESED MAY BE SUBJECT TO AN ADDITIONAL REVIEW FEE PER ST. LUCIE COUNTY RESOLUTION #13-196 lb COMMENTSSENT 1015/2017 Comment: COMMENTS E-MAILED AS OF THIS DATE ZONING REVIEW (1 INCOMPLETE Lydia Galbraith 8115/2017 10/4/2017 Comment: — /FORWARD ONE SET OF PLANS TO ENGINEERING FOR CONSTRUCTABILITY REVIEW. 10/412017 Comment (- v 10/4117 EMAIL TO BABY IN WATER QUALITY TO CHECK IF THEY RECEIVED THE STORM WATER APPL. Planning& Development Services REVIEW COMMENTS Building & Code Regulation Division 2300 Virginia Avenue. Fort Pierce, FL 34982 Phone:(772)462.2172 Faxa772)462-6443 Page 1 Address: 5804 Indian Pine Blvd City / State / Zip: Fort Pierce, FI 34951 Parcel #: 1312-110-0101-010/0 Zoning: CO APPLICATION INFORMATION Permit Number: 1707-0529 Permit Type: COMMERCIAL ADDITION Owner(s): Madetric N Wood Jurisdiction: ST LUCIE COUNTY Lot#: Block: ' Contractor Name: Ramses Rodriguez Business Name: Tri - R Construction Company Inc Business Addr: 1457 Sw Prairie Cir City / State / Zip: Port St Lucie, FI 34953 REVIEWS AND COMMENTS Review Tyne Status Reviewed By DOCUMENTS MISSING COMPLETE Karen Nielsen Comment: ENGINEERING DEPARTMENT COMPLETE Comment: Stories: ENVIRONMENTAL REVIEW COMPLETE Lynn Swartzel Comment: FIRE DEPARTMENT REVIEW COMPLETE Tony Jerger Comment: FRONT COUNTER REVIEW COMPLETE Karen Nielsen Comment: NOTIFIED FOR PICK UP COMPLETE Lydia Galbraith Comment: PLANS EXAMINER ELECTRIC COMPLETE Walter Pride Comment: PLANS EXAMINER MECHANICAL COMPLETE Carl Peterson Comment: Automatic Sprinkler System? No Fax Number: 772-336-6486 Email: Ramsesrdguez@Hotmail.Co m Date Started Date Completed Date Released 712512017 41612018 41612018 218/2018 21812018 11/2212017 1/912018 119/2018 11/27/2017 11128/2017 1112812017 712512017 7125/2017 712512017 21812018 21812018 218/2018 812912017 9/612017 91512017 101212017 1012/2017 Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue. Fort Pierce, FL 34982 Phono:(772)462.2172 Fax:(772)462.6443 REVIEW COMMENTS 2 PLANS EXAMINER PLUMBING COMPLETE Greg Smyth 812912017 1012712017 10/27/2017 Comment: PLANS EXAMINER REVIEW COMPLETE Joe Ciclo 812812017 10/2712017 10/27/2017 Comment: REVISIONS INCOMPLETE Joe Ciclo 611412018 6/14/2018 Comment: SUBMIT THE MANUFACTURERS TRUSS LAYOUTS IN TRIPLICATE FOR THIS PROJECT FAC 61G-15-31 ` MUST BE REVIEWED AND APPROVED BY THE DESIGN PROFESSIONAL OF RECORD Comment: SUBMIT THE ENGINEERED CUT SHEETS IN TRIPLICATE FROM THE TRUSS DESIGN ENGINEER WITH 6/14/2018 ORIGINAL SIGNATURES, SEALED AND DATED' MUST BE REVIEWED AND APPROVED BY THE DESIGN PROFESSIONAL OF RECORD Comment: ALL PLANS ARE STILL DRAWN WITH 8" EXTERIOR WALLS AND A-2 IS SHOWING CBS INFILLS ` PLS 6/1412018 CORRECT ALL DRAWINGS TO FRAME CONSTRUCTION' ELIMINATE ALL PLAN DETAILS REFERRING TO CBS CONSTRUCTION 6/14/2018 Comment: ARCHITECT TO DIMENSION ALL REVISED FLOOR PLANS ' SEE FBC 107.2.1 6/15/2018 Comment: [ PREVIOUS DEFERRED SUBMITTAL ] SHOW A FULL DETAIL OF THE SERVICE COUNTER ON PLANS COMPLYING WITH THE FBC ACCESSIBILITY 904.4.1 AND 904.4.2 6/1612018 Comment: SUBMIT [ 3 ] SETS OF REVISED ENERGY CALCS BY ERIC SVOBODA FOR THE EXTERIOR WALL CHANGES 6/1512018 Comment: RE -SUBMIT ALL PLANS AND DOCS IN TRIPLICATE WI [ 1 ] PDF DISC Comment: DESIGN PROFESSIONAL TO MODIFY ALL FASTENERS FOR THE WINDOWS, DOORS AND SHUTTERS TO BE 611512018 COMPIANT WITH THE TESTED PRODUCT APPROVAL [ FRAME ] SPECIFICATIONS ON THE PRODUCT AFFIDAVITS Comment: SUBMIT THE PRODUCT APPROVAL IN TRIPLICATE FOR THE CEDAR SIDING AND SHOW THE ATTACHMENT 611512018 METHOD ON PLANS • IF USING STUCCO SHOW THE TESTING AND APPLICATION SPECS ON PLANS PER FBC 2512.1 AND ASTM C926 6/1512018 Comment: SUBMIT THE MANUFACTURERS PRODUCT APPROVAL FOR THE 6" EXP BOLTS • GENERAL EDGE DISTANCE MUST BE DETERMINED AND DETAILED ON PLANS W/ EMBED LENGTH 611512018 Comment: SHOW THE ATTACHMENT METHODS ON PLANS FOR THE INTERIOR TYPICAL PARTITIONS A-3 Comment: SHOW THE ATTACHMENT TYPE AND SPACING METHOD ON PLANS PER THE TESTING STANDARDS FOR 611512018 THE WALL AND CEILING DRYWALL. PER GA-216 CRITERIA IF THE CEILING IS TO RECEIVE HAND OR SPRAY MATERIAL IT MUST BE 5/8" DRYWALL 611512018 Comment: DETAIL THE FACIA AND SOFFIT INSTALLATION ON PLANS PER CURRENT CODES ` NOT MATCH EXISTING Comment: PLEASE NOTE: (1) ALL REVIEW COMMENTS WHEN ANSWERED WILL REQUIRE A COVER LETTER ADDRESSING WHERE THE CHANGES WERE MADE, (2) ALL CHANGES WILL BE REQUIRED TO BE CLOUDED ON THE PLANS AND (3) THE CONTRACTOR WHEN RESUBMITTING WILL BE REQUIRED TO INSERT THE NEW UPDATED PAGES INTO THE PLANS OR IF THE CONTRACTOR PREFERS, A REVISED COMPLETE SET OF PLANS CAN BE SUBMITTED 6115/2018 PLEASE NOTE THAT A SUBMITTAL CHECKLIST WILL BE REQUIRED STATING THE TYPE AND QUANTITY OF DOCUMENTS SUBMITTED FOR RE -REVIEW SIGNED AND DATED BY THE CONTRACTOR PLEASE NOTE ANY COMMENT NOT ADDRESED MAY BE SUBJECT TO AN ADDITIONAL REVIEW FEE PER ST. LUCIE COUNTY RESOLUTION #13-196 COMMENTS SENT 6115/2018 Comment: COMMENTS E-MAILED AS OF THIS DATE ZONING REVIEW COMPLETE Lydia Galbraith 811612017 Comment: 218/2018 218/2018 �• �irrnr. U�acm Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue. Fort Pierce, FL..U982 Phohe:(772)462-2172 Fax:(772)462.6448 :PROPERTY INFORMATION Address: 5804 Indian Pine Blvd City / State / Zip: Fort Pierce, FI 34951 Parcel#: 1312-110-0101-010/0 Zoning: CO APPLICATION INFORMATION ! Permit Number: 1707-0529 Permit Type: COMMERCIAL ADDITION CONTRACTOR INFORMATION Confractor Name: ;Business Name: ,Business Addr: City / State / Zip: REVIEWS AND COMMENTS 'Review Tyne Status DOCUMENTS MISSING COMPLETE REVIEW COMMENTS 1 Owner(s): Madetric N Wood Jurisdiction: ST LUCIE COUNTY Lot#: Block: Stories: Automatic Sprinkler System? No Fax Number: Email: Reviewed By Date Started Date Completed Date Released Karen Nielsen 7/25/2017 416/2018 41612018 Comment: I I ENGINEERING DEPARTMENT COMPLETE 21812018 218/2018 j Comment: I, "ENVIRONMENTAL REVIEW COMPLETE Lynn Swartzel 11/2212017 1/912018 119/2018 is }. Comment: FIRE,DEPARTMENT REVIEW s COMPLETE Tony Jerger 1112712017 11/28/2017 11/2812017 Comment: `FRONT COUNTER REVIEW COMPLETE Karen Nielsen 7/26/2017 7/2512017 712512017 Comment: NOTIFIED FOR PICK UP COMPLETE Lydia Galbraith 218/2018 21812018 218/2018 - Comment: PE REVIEW COMMENTS (2) INCOMPLETE Joe Ciclo 6/2512018 Comment: SUBMIT THE MANUFACTURERS TRUSS LAYOUTS IN TRIPLICATE FOR THIS PROJECT FAC 61 G-15-31 6/25/2018 MUST BE REVIEWED AND APPROVED BY THE DESIGN PROFESSIONAL OF RECORD •• DID NOT RECEIVE •' SECOND REVIEW Comment: SUBMIT THE ENGINEERED CUT SHEETS IN TRIPLICATE FROM THE TRUSS DESIGN ENGINEER WITH 6/2512018 ORIGINAL SIGNATURES, SEALED AND DATED • MUST BE REVIEWED AND APPROVED BY THE DESIGN PROFESSIONAL OF RECORD •• DID NOT RECEIVE •• SECOND REVIEW Jri ,i+Nfi� (/08t Pianninq & Develdpmer Fort REVIEW COMMENTS z Comment: ALL PLANS ARE STILL DRAWN WITH 8" EXTERIOR WALLS AND A-2 IS SHOWING CBS INFILLS • PLS CORRECT ALL DRAWINGS TO FRAME CONSTRUCTION • ELIMINATE ALL PLAN DETAILS REFERRING TO 6/25/2018 CBS CONSTRUCTION " SECOND REVIEW •• DESIGN PRO TO ELIMINATE ALL NOTES AND DETAILS FROM PLANS RELATING TO CBS CONSTRUCTION •` SEE A-1 •• A-1 AND A-2 ARE STILL DRAWN WITH CBS EXTERIOR WALLS BOTH FOR THE EXISTING BUILDING AND THE ADDITION Comment: RE -SUBMIT ALL PLANS AND DOCS IN TRIPLICATE W/ [ 1 ] PDF DISC `• DID NOT RECEIVE THE PDF DISC •• 6/2512018 PLEASE RE -SUBMIT [ 31 SETS OF CORRECTED PLANS W/ [ 11 PDF DISC Comment: SUBMIT THE PRODUCT APPROVAL IN TRIPLICATE FOR THE CEDAR SIDING AND SHOW THE ATTACHMENT METHOD ON PLANS' IF USING STUCCO SHOW THE TESTING AND APPLICATION SPECS ON PLANS PER 6/2512018 FBG 2512.1 AND ASTM C926 •• SECOND REVIEW .• WALL SECTION ON A-3 REFERS TO STUCCO AND T-111 SIDING / DESIGN PRO TO ELIMINATE ONE OR THE OTHER Comment: PLEASE NOTE: (1) ALL REVIEW COMMENTS WHEN ANSWERED WILL REQUIRE A COVER LETTER ADDRESSING WHERE THE CHANGES WERE MADE, (2) ALL CHANGES WILL BE REQUIRED TO BE CLOUDED ON THE PLANS AND (3) THE CONTRACTOR WHEN RESUBMITTING WILL BE REQUIRED TO INSERT THE NEW UPDATED PAGES INTO THE PLANS OR IF THE CONTRACTOR PREFERS, A REVISED COMPLETE SET OF PLANS CAN BE SUBMITTED 6/25/2018 2 PLEASE NOTE THAT A SUBMITTAL CHECKLIST WILL BE REQUIRED STATING THE TYPE AND QUANTITY OF DOCUMENTS SUBMITTED FOR RE -REVIEW SIGNED AND DATED BY THE CONTRACTOR PLEASE NOTE ANY COMMENT NOT ADDRESED MAY BE SUBJECT TO AN ADDITIONAL REVIEW FEE PER ST. ' LUCIE COUNTY RESOLUTION #13-196 COMMENTS SENT i 6/2512018 Comment: COMMENTS E-MAILED AS OF THIS DATE ` PLEASE PAY THE REVIEW FEES UPON RE -SUBMITTAL PLANS EXAMINER ELECTRIC COMPLETE Walter Pride 8129/2017 9/512017 91512017 Comment: PLANS EXAMINER MECHANICAL COMPLETE Carl Peterson 101212017 1012/2017 Comment: PLANS EXAMINER PLUMBING COMPLETE Greg Smyth 6/29/2017 10/27/2017 1012712017 Comment: PLANS EXAMINER REVIEW COMPLETE Joe Cicio 8/28/2017 10/27/2017 10127/2017 Comment: ! PLANS EXAMINER REVIEW I ' COMPLETE Joe Cicio 611412018 612512018 612512018 Comment: ZONING REVIEW COMPLETE Lydia Galbraith 8/15/2017 21812018 218/2018 Comment: