HomeMy WebLinkAboutSUBMITTED PAPPERSSCANNED BY St. Lucie County ST LUCIE COUNTY FIRE DISTRICT Office of the Fire Marshal Plan Review 240 Rhode Island Avenue Telephone: 772.462.8306 Ft Pierce, FL 34950 FAX: 772.462.8466 THE FLORIDA FIRE PREVENTION CODE, 2004 EDITION IS CURRENTLY ENFORCED. The Code is based on NFPA 1 and NFPA 101, 2003 Florida Specific edition. Jurisdiction: SLC FMO Permit #: B-05-1475 Project Name: Ocean Bay Villas Bldg. 27 Building Permit #: 0509-0601 Address: 142-146 Ocean Bay Drive Contractor Kirchman Construction Co Phone # 772.283.4256 Contractor's Address: 2597 SE Delmar St City: Stuart State: FL Zip Code: 34997 Architect/Engineer: Raul Sotolongo Phone # 305.593.0096 Occupancy Type: Apartments AS Permit: Required Construction Type: VI unp FA Permit: Required Square feet: 9,118 FFP Permit: Number of stories: Access Box: Occupant Load: Access Key Switch: NOTE 1. All revisions, including the electronic copy must be received prior to permitting. 2. The Fire Marshal requires 24 hour notice on all inspections. 3. The respective Building Department shall schedule all final inspections through the Fire Marshal's Office. 4. Failed inspections require payment of fee prior to rescheduling of further inspections. 5. Penetrations through rated assemblies shall be of proper UL design. Design criteria shall be submitted with the construction plans. 6. Fire alarm panels shall be located indoors within a controlled environment. 7. Plans and construction are subject to corrections in the field to maintain code compliance. Required Revisions An electronic version of the construction plans on a CD is required. The file format shall be either a .dwg or .pdf. The CD shall contain a sheet index file. Files shall be separated by discipline. Files names shall match construction documents sheet numbers. 1. A separate permit is required for the installation of the fire sprinkler and alarm systems. Reviewed by: T. Liento I"h Date: 11l112005 Product Review Affidavit ;COLINTY St Lucie County, Public Works Department Code Compliance Division The following products will be installed in the structure located at ocean Bay viilas Building Permit # Owners Name Pukka Development Owner's Address 11027 S. Ocean Drive Contractor Contractor's Address Product *Product Bated Manufacturer Model Number Method of Attachment — Design Pressures Windows Fia in the rated wind design pressures listed by the manufacturer for each product limed 1st Choice T +51.5/ -68.9 PGT H 701-B 6 D As per prod. approval 6 Mullions Manufacturer's specifica Glass --I- 1st Choice �J C) Skylights I "" N/A iss (other) Butt Glass N/A Glass Block N/A line Glass Doors 'GT PW 701- B6 I As per prod. a N/A I N/A I Manufacturer's N/A 1st Choice } 9.2/ -53.6 PGT SGD- 70 As per prod. a proval 6 2nd Choice w own Manufacturers specificat Swing Type Doors 1st Choice +49.2 -53.6 PlastDroINOA D850225 2nd Choice e Manufacturer's specificat Overhead Garage Doors 1st Choice ? +43.8/ -53.6 DAB Doors NOA 00-1121. 1- double/ As per prod. ap 2nd Choice o ec�manu j DAB Doors NOA 01-0516. . sped is 3- single Material /. Metal I - N/A I N/A I N/A I Other ISee attached p od. Hanson I wnA n9_nou no A- --- ---A 16hutters -"`- -- "` --- Manuf. specifications. 1 have reviewed the above components and cladding, and have approved their use in the structure to provide adequate resistance to the wind loads and forces specified by current code provisions. Name:T--AUL— �F, �01 Ot,-\C Signature Y� t Design Fir ECi M � aJ C J �Rc N \Vert. No. Aiz :-t l 12 Date: % Q1 rtcaua 510vo3 i ions . Lons . )royal 6 ltiOUS. i St. Lucie County Building and Zoning Department 2300 Virginia Avenue Fort Pierce, FL 34982 561-462-1553 Design Certification for Wind Load Compliance This Certification is to be completed by the project design architect or engineer. This Certification must be submitted with all applications for building permits involving the construction of new residence (single or nwlli- family), residential addition, any accessory structure requiring a building permit, and any nonresidential stricture. This Certification shall not apply to interior renovations (provided that no stnictural walls, columns or other similar component is being effected) and certain other minor building permits. For further assistance, please contact the Building Inspection Office at 462-1553 or462-2172. , Project Name c:LrW bk VlWAf=> Office Use Only Street Address Perin Nnmber Occu anc Ty e Construction T e Certification Statement: I certify that, to the best of my knowledge and belief, these plans and specifications have been designed to comply with the applicable structural portion of the Building Codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the wind loads and forces specified by current code provisions. Design Parameters and Assumptions Used: (Please check or complete the appropriate box.) 1. Florida Building Code 2001 Edition ASCE 7-98 C 2. Building Design is (check one) Enclosed Partially Enclosed Open Building 3. Building Height: 3q — (o° 4. Wind Speed Used in Building Design: NO trPA 3 second gust 5. Wind Exposure Classification (refer to exposure tables in Building Code identified in Line #11): 6. Average Wind Velocity Pressure on Exterior Faces of Structure tJ {, PSF 7. Peak Wind Velocity Pressure on Exterior Faces of Structure K/A PSF 8. Importance/Use Factor (obtain from Building Code): I -O 9. Loads: Floor 30+L40 PSF Roof/dead 20 PSF Root%ll'i 20 PSF 10. Were Shear Walls Considered for Structure (check one): Ye. d No _(if No, attach explanation) 11. Is a Continuous Load Path Provided (check one): Yes t�No (if No, attach explanafion) 12. Are Component and Cladding Detail Provided (check one): Yes _ No (if No, attach explanation) 13. Minimum Soil Bearing Pressure: 300C) PSF As witnessed by my seal, I hereby certify that the information included with this certification is true and correct, to the best of my knowledge and belief. Name_:;E,4X��C ' . Certification ft: A9,- —1-7 ►'L. [Seal Here] G Design Firm: _�OtO��n A�—��1—� Date: SLC'C'DV Fur n # 020-00 FORM 60OA-2001 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A Project Name: Ocean Bay Villas Cocoplum Builder: Address: Permitting Office: Port St. Lucie City, State: Permit Number: Owner: Anchor Bay Development Jurisdiction Number: 661200 Climate Zone: Central I. New construction or existing New _ 2. Single family or multi -family Multi -family 3. Number of units, if multi -family 3 _ 4. Number of Bedrooms 3 _ 5. Is this a worst case? No 6. Conditioned floor area (W) _ 2579 ft' 7. Glass area & type Single Pane Double Pane a. Clear Mass, default U-factor 0.0 ft' 0.0 ft' _ b. Default tint 519.41`0 0.0 IF _ c. Labeled U or SHGC 0.0 it, 0.0 it, S. Floor types _ a. Slab -On -Grade Edge Insulation R=0.0, IO2.0(p) It b. N/A c. N/A _ 9. Wall types _ a. Frame, Wood, Adjacent R=11.0, 191.0 W _ b. Concrete, [tit Insul, Exterior R=5.0, 2202.0 it-' _ c. N/A d. N/A _ e. N/A 10. Ceiling types a. Under Attic _ R=30.0, 1021.0 ft' b. N/A _ c. N/A _ 11. Ducts a. Sup: Unc. Ret: Con. AH(Sealed):Interior Sup. R=6.0, 30.0 It b. N/A _ 12. Cooling systems a. Central Unit b. N/A c. N/A 13. Heating systems a. Electric Heat Pump b. N/A c. N/A 14. Hot water systems a. Electric Resistance b. N/A c. Conservation credits (HR-Heat recovery, Solar DHP-Dedicated heat pump) 15. HVAC credits (CF-Ceiling fan, CV -Cross ventilation, HF-Whole house fan, PT -Programmable Thermostat, MZ-C-Multizone cooling, MZH-Multizone heating) Glass/Floor Area: 0.20 Total as -built points: 33985 PASS Total base points: 34663 'I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. PREPARED BY: DATE: �is 1 hereby certify that this building, as d, compliance with the Florida Energy -Code. OWNER/AGENT: DATE: Review of the plans and -specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 FloridaStatutes. ' BUILDING OFFICIAL: DATE: Cap: 60.0 kBtu/hr _ SEER: 10.20 Cap: 34.0 kBtu/hr _ HSPF: 7.20 Cap: 50.0 gallons EF: 0.89 PT, EnergyGauge® (Version: FLRCPB v3.30) FORM 60OA-2001 SUMMER CALCULATIONS, Residential Whole Building Performance Method A - Details ADDRESS: , , , PERMIT #: I BASE AS -BUILT GLASS TYPES .18 X Conditioned X BSPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X SPM X SOF = Points .18 2579.0 25.78 11967.6 Single, Tint W 5.0 8.0 192.0 47.90 0.67 6162.0 Single, Tint W 1.5 28.0 32.8 47.90 1.00 1566.6 Single, Tint W 1.5 18.0 49.0 47.90 1.00 2336.6 I Single, Tint W 1.5 5.4 18.6 47.90 0.90 798.6 Single, Tint E 1.5 22.0 49.8 53.27 1.00 2642.4 Single. Tint E 1.5 8.8 12.6 53.27 0.97 650.3 Single, Tint E 1.5 11.7 26.4 53.27 0.99 1390.7 Single, Tint N 1.5 31.2 16.6 24.46 1.00 404.9 Single, Tint N 1.5 20.0 49.8 24.46 1.00 1212.6 Single, Tint N 5.0 8.0 16.6 24.46 0.80 324.4 Single, Tint N 1.5 9.3 33.2 24.46 0.98 794.1 Single, Tint N 1.5 8.3 22.0 24.46 0.97 522.4 As -Built Total: 519.4 18805.6 WALL TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Adjacent 191.0 0.70 133.7 Frame, Wood, Adjacent 11.0 191.0 0.70 133.7 Exterior 2202.0 1.90 4183.8 Concrete, Int Insul, Exterior 5.0 2202.0 1.00 2202.0 Base Total: 2393.0 4317.5 As -Built Total: 2393.0 2335.7 DOOR TYPES Area X BSPM = Points Type Area X SPM = Points Adjacent 21.3 1.60 34.1 Adjacent Insulated 21.3 1.60 34.1 Exterior 28.0 4.80 134.4 Exterior Insulated 28.0 4.80 134.4 Base Total: 49.3 168.5 As -Built Total: 49.3 168.5 CEILING TYPES Area X BSPM = Points Type R-Value Area X SPM X SCM = Points Under Attic 1021.0 2.13 2174.7 Under -Attic 30.0 1021.0 2.13X 1.00 2174.7 - Base Total: 1021.0 2174.7 As -Built Total: 1021.0 2174.7 FLOOR TYPES Area X BSPM = Points Type_ R-Value Area X SPM = Points Slab 102.0(p) -31.8 -3243.6 Slab -On -Grade Edge Insulation 0.0 102.0(p -31.90 -3253.8 Raised 0.0 0.00 0.0 Base Total: -3243.6 As -Built Total: 102.0 -3253.8 EnergyGaugea0 DCA Form 60OA-2001 EnergyGauge®/FlaRES'2001 FLRCPB v3.30 FORM 60OA-2001 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details I ADDRESS:... PERMIT #: I BASE AS -BUILT INFILTRATION Area X BSPM = Points Area X SPM = Points 2579.0 14.31 36905.5 2579.0 14.31 36905.5 Summer Base Points: 52290.2 Summer As -Built Points: 57136.2 Total Summer Points X System Multiplier = Cooling Points Total X Component Cap Ratio X Duct X System X Multiplier Multiplier (DM x DSM x AHU) Credit Multiplier = Cooling Points 52290.2 0.4266 22307.0 57136.2 57136.2 1.000 1.00 (1.079 x 1.150 x 0.85) 0.334 1.061 0.334 0.950 0.950 19252.0 19252.0 EnergyGaugeTM DCA Form 60OA-2001 EnergyGauge®/FlaRES'2001 FLRCPS v3.30 FORM 60OA-2001 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , , , PERMIT #: BASE AS -BUILT GLASS TYPES .18 X Conditioned X BWPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X WPM X WOF = Points .18 2579.0 5.86 2720.3 Single, Tint W 5.0 8.0 192.0 13.80 1.06 2802.3 Single, Tint W 1.5 28.0 32.8 13.80 1.00 452.4 Single, Tint W 1.5 18.0 49.0 13.80 1.00 675.6 Single, Tint W 1.5 5.4 18.6 13.80 1.01 260.2 Single, Tint E 1.5 22.0 49.8 13.04 1.00 650.8 - Single, Tint E 1.5 8.8 12.6 13.04 1.01 165.7 Single,Tint E 1.5 11.7 26.4 13.04 1.01 346.0 Single, Tint N 1.5 31.2 16.6 15.38 1.OD 255.2 Single, Tint N 1.5 20.0 49.8 15.38 1.00 765.2 Single, Tint N 5.0 8.0 16.6 15.38 0.99 253.4 Single,Tint N 1.5 9.3 33.2 15.38 1.00 509.5 Single, Tint N 1.5 8.3 22.0 15.38 1.00 337.6 As -Built Total: 519.4 7473.8 WALL TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Adjacent 191.0 1.80 343.8 Frame, Wood. Adjacent 11.0 191.0 1.80 343.8 Exterior 2202.0 2.00 4404.0 Concrete, Int Insul, Exterior 5.0 2202.0 2.90 6385.8 Base Total: 2393.0 4747.8 As -Built Total: 2393.0 6729.6 DOOR TYPES Area X BWPM = Points Type Area X WPM = . Points Adjacent 21.3 4.00 85.2 Adjacent Insulated 21.3 4.00 85.2 Exterior 28.0 5.10 142.8 Exterior Insulated 28.0 5.10 142.8 Base Total: 49.3 -228.0 As -Built Total: 49.3 228.0 CEILING TYPES Area X BWPM = Points Type R-Value Area X WPM X WCM = Points Under Attic 1021.0 0.64 653.4 Under Attic 30.0 1021.0 0.64X 1.00 653.4 Base Total: 1021.0 653.4 As -Built Total: 1021.0 653.4 FLOOR TYPES Area X BWPM = Points Type_ R-Value Area X WPM = Points Slab 102.0(p) -1.9 -193.8 Slab -On -Grade Edge Insulation 0.0 102.0(p 2.50 255.0 Raised 0.0 0.00 0.0 Base Total: -193.8 As -Built Total: - 102.0 255.0 EnergyGaugeO DCA Form 60OA-2001 EnergyGaugeOlFlaRES'2001 FLRCPB v3.30 FORM 60OA-2001 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS:... PERMIT #: BASE AS -BUILT INFILTRATION Area X BWPM = Points Area X WPM = Points 2579.0 -0.28 -722.1 2579.0 -0.28 -722.1 Winter Base Points: 7433.6 Winter As -Built Points: 14617.7 Total Winter X Points System Multiplier = Heating Points Total X Component Cap Ratio X Duct X System X Multiplier Multiplier (DM x DSM x AHU) Credit Multiplier = Heating Points I 7433.6 0.6274 4663.9 14617.7 14617.7 1.000 1.00 (1.068 x 1.160 x 0.87) 0.474 1.083 0.474 0.950 0.950 7127.7 7127.7 EnergyGaugeT" DCA Form 60OA-2001 EnergyGauge®/RaRES'2001 FLRCPB v3.30 FORM 60OA-2001 WATER HEATING & CODE COMPLIANCE STATUS Residential Whole Building Performance Method A - Details I ADDRESS: , , , PERMIT #: BASE AS -BUILT WATER HEATING Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total Bedrooms Volume Bedrooms Ratio Multiplier 3 2564.00 7692.0 50.0 0.89 3 1.00 2535.19 1.00 7605.6 As -Built Total: 7605.6 CODE COMPLIANCE STATUS BASE AS -BUILT Cooling + Heating + Points Points Hot Water Points = Total Points Cooling Points + Heating + Hot Water = Total Points Points Points 22307 4664 7692 34663 19252 7128 7606 33985 EnergyGaugel- DCA Form 600A-2001 EnergyGauge®/FlaRES2001 FLRCPB v3.30 FORM 60OA-2001 Code Compliance Checklist Residential Whole Building Performance Method A - Details ADDRESS: , , , PERMIT #: 6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS I SECTION I REQUIREMENTS FOR EACH PRACTICE CHEC Exterior Windows & Doors 606.1.ABC.1.1 Maximum:.3 cfm/s .ft. window area; .5 cfm/s .ft. door area. Exterior & Adjacent Walls 606.1.ABC.1.2.1 I Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; foundation & wall sole or sill plate; joints between exterior wall panels at comers; utility / penetrations; between wall panels & top/bottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from and is sealed to the foundation to the top plate. Floors 606.1.ABC.1.2.2. Penetrations/openings >1/8" sealed unless. backed by truss or joint members. EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed to the perimeter, penetrations and seams. Ceilings 606.1.ABC.1.2.3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter, at penetrations and seams. Recessed Lighting Fixtures 606.1.ABC.12.4 Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed Inside a sealed box with 112" clearance & 3" from insulation; or Type IC rated with <2.0 cfm from conditioned space, tested. Multi -story Houses 1606.1.ABC.1.2.5 Air barrier on perimeter of -floor cavity between floors. Additional Infiltration regts 606.1.ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, r have combustion air. 6A-22 OTHER PRESCRIPTIVE MEASURES fmust hp met nr pxrppriprl by all rpsirienrpg 1 COMPONENTS I SECTION I REQUIREMENTS I CHECK Water Heaters 612.1 Comply with efficiency requirements in Table 6-12. Switch or clearly marked circuit -� breaker electric or cutoff as must be provided. External or built-in heat trap required. Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a pump timer. Gas spa & pool healers must have a minimum thermal efficient of 78%. Shower heads 612.1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. Air Distribution Systems 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated, and installed in accordance with the criteria of Section 610. Ducts in unconditioned attics: R-6 min. insulation. HVAC Controls 607.1 Separate readily accessible manual or automatic thermostat for each system. Insulation 604.1, 602.1 Ceilings -Min. R-19. Common walls -Frame R-11 or CBS R-3 both sides. Common ceiling & floors R-11. EnergyGauge^" DCA Form 60OA-2001 EnergyGauge®/FlaRES'2001 FLRCPB v3.30 ENERGY PERFORMANCE LEVEL (EPA.) ESTIMATED ENERGY PERFORMANCE SCORE* = 83.4 The higher the score, the more efficient the home. 1. New construction or existing 2. Single family or multi -family 3. Number of units, if multi -family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (f12) 7. Glass area &. type Single Pane a. Clear - single pane 0.0 ft' b. Clear - double pane 519.4 ft' c. Tint/other SHGC - single pane 0.0 f , d. Tint/other SHGC - double pane 8. Floor types a. Slab -On -Grade Edge insulation b. N/A c. N/A 9. Wall types a. Frame, Wood, Adjacent b. Concrete, Int Insul, Exterior c. N/A d. N/A e. N/A 10. Ceiling types a. Under Attic b. N/A c. N/A 11. Ducts a. Sup: Unc. Ret: Con. AH(Sealed):Interior b. N/A Anchor Bay Development, , , , New _ 12. Cooling systems Multi -family _ a. Central Unit 3 _ 3 _ b. N/A No _ 2579 IF c. N/A Double Pane _ 0.0 fP _ 13. Heating systems 0.0 ft' _ a. Electric Heat Pump 0.0 fP b. N/A R=0.0, 102.0(p) It R= 11.0, 191.0 ft' _ R=5.0, 2202.0 W _ R=30.0, 1021.0 ft' Sup. R=6.0, 30.0 ft c. N/A 14. Hot water systems a. Electric Resistance b. N/A c. Conservation credits (HR-Heat recovery, Solar DHP-Dedicated heat pump) 15. HVAC credits (CF-Ceiling fan, CV -Cross ventilation, HF-Whole house fan, PT -Programmable Themmstat, MZ-C-Multizone cooling, MZ-H-Multizone heating) I certify that this home has complied with the Florida Energy Efficiency Code For Buildine Construction through the above energy saving features wh'ch will be inste in this home before final ins c herw' e L Display Card' based on installe r Build r ignature: Date: Address of New Home: 1966AtN City/FL Zip: Cap: 60.0 kBtu/hr _ SEER: 10.20 _ Cap: 34.0 kBtu/hr HSPF: 7.20 Cap: 50.0 gallons _ EF: 0.89 _ PT, _ "NOTE: The home's estimated energy, performance score is only available through the FLARES computer program. This is not a Building Energy Rating. If your score is 80 0-greater (or 86f07- a US EPA/DOE Enere-Stai-"Oiesigrnation), rota• home near qualifr,for energy e1cien0r mortgage (EEM) incentives if yott obtain a Florida Energy Gauge Rating. Contact the Energy Gauge Hotline at 3211638-1492 a• see the Energl- Gauge web site at unnvfsec.ucf edu for it formation and a list of certified Raters. For information about Florida's Energy Efficiency Code For Building Construction, contact theDepar4nfent ofCommunih-Affairs at 8501487-1824. EnergyGaugeb (Version: FLRCPB v330) Summary Energy Code Results Residential Whole Building Performance Method A Anchor Bay Development Project Title: Code Only Ocean Bay Villas Cocoplum Professional Version Climate: Central 7/1 /2004 Building Loads Base As -Built Summer: 52290 points Summer: 57136 points I Winter: 7434 points Winter: 14618 points Hot Water: 6769 points Hot Water: 6769 points Total: 66493 points Total: 78523 points Energy Use Base As -Built Cooling: 22307 points Cooling: 19252 paints Heating: 4664 points Heating: 7128 points Hot Water: 7692 points Hot Water: 7606 points Total: 34663 points Total: 33935 points PASS e-Ratio: 0.98 EnergyGauge®(Version: FLRCPB v3.30) residential System Sizing Calculation Summary Anchor Bay Development Project Title: Code Only Ocean Bay Villas Cocoplum Professional Version Climate: Central 7)i ionnn Location for weather data: Fort Pierce - Defaults: Latitude(27) Temp Range(L) Humidi data: Interior RH (50%) Outdoor wet bulb 78F Humidity difference 62 r. Winter design temperature 42 F Summer design temperature 90 F Winter setpoint 70 F Summer setpoint 75 F Winter temperature difference 28 F Summer temperature difference 15 F Total heating load calculation 33330 Btuh Total cooling load calculation 46002 Btuh Submitted heating capacity % of calc Btuh Submitted cooling capacity % of calc Btuh Total (Electric Heat Pump) 102.0 34000 Sensible (SHR = 0.7) 106.2 42000 Heat Pump + Auxiliary(O.OkW) 102.0 34000 Latent 278.5 18000 Total Electric Heat Pump) 130.4 60000 WINTER CALCULATIONS Winter Hoafinn I narl (fnr 757Q cnft) Load component Load Window total 519 sqft 14543 Btuh Wall total 2393 sqft 9152 Btuh Door total 49 sqft 569 Btuh Ceiling total 1021 sqft 919 Btuh Floor total 102 ft 2315 Btuh Infiltration 138 cfm 4245 Btuh Subtotal 31743 Btuh Duct loss 1587 Btuh TOTAL HEAT LOSS 33330 Btuh Summer Coolino Load (for 2579 soft wns(s^b) h.a Dvots(3� Fvmv(1w) Ws �emngsz , SUMMER CALCULATIONS Load component Load Window total 519 sqft 21909 Btuh Wall total 2393 sqft 5093 Btuh Door total 49 sqft 523 Btuh Ceiling total 1021 sqft 1429 Btuh Floor total 0 Btuh Infiltration 121 cfm 1990 Btuh Internal gain 5000 Btuh Subtotal(sensible) 35943 Btuh Duct gain 3594 Btuh Total sensible gain 39537 Btuh Latent gain (infiltration) 5084 Btuh Latent gain(internal) 1380 Btuh Total latent gain 6464 Btuh TOTAL HEAT GAIN 46002 Btuh EnergyGaugeO LWeM IMc 1(3%) 1M.Gvi EnergyGauge® System Sizin e ACCA M ual J. PREPARED BY: DATE: FLRCPB v3.30 System Sizing Calculations - Summer Residential Load - Component Details Anchor Bay Development Project Title: Code Only Ocean Bay Villas Cocoplum Professional Version Climate: Central Reference City: Fort Pierce (Defaults) Summer Temperature Difference: 15.0 F 7/1/2004 Type I Overhang Window Area(sqft) HTM Load Window Panes/SHGC/U/InSh/ExSh Ornt Len Hot Gross Shaded Unshaded Shaded Unshaded 1 1, Tint, 1.00, N, N W 5 8 192.0 99.6 92.4 20 61 7628 Btuh 2 1, Tint, 1.00, N, N W 1.5 28 32.8 0.0 32.8 20 61 2001 Btuh 3 1, Tint, 1.00, N, N W 1.5 18 49.0 0.0 49.0 20 61 2989 Btuh 4 1, Tint, 1.00, N. N W 1.5 5.41 18.6 0.6 18.0 20 61 1110 Btuh 5 1, Tint, 1.00,TI, N E 1.5 22 49.8 0.0 49.8 20 61 3038 Btuh .6 1, Tint; 1.00, N, N E 1.5 8.83 12.6 0.0 12.6 20 61 769 Btuh 7 1, Tint, 1.00, N, N E 1.5 11.6 26.4 0.0 26.4 20 61 1610 Btuh 8 1, Tint, 1.00, N, N N 1.5 31.1 16.6 0.0 16.6 20 20 332 Btuh 9 1, Tint, 1.00. N, N N 1.5 20 49.8 0.0 49.8 20 20 996 Btuh 10 1, Tint, 1.00, N, N N 5 8 16.6 0.0 16.6 20 20 332 Btuh 11 1, Tint, 1.00, N, N N 1.5 9.33 33.2 0.0 33.2 20 20 664 Btuh 12 1, Tint, 1.00, N, N N 1.5 8.33 22.0 0.0 22.0 20 20 440 Btuh Window Total 519 21909 Btuh Walls Type R-Value Area HTM Load 1 Frame -Adjacent 11.0 191.0 1.3 248 Stuh 2 Concrete - Exterior 5.0 2202.0 2.2 4844 Btuh Wall Total 2393.0 5093 Btuh Doors Type Area HTM Load 1 Insulated -Adjac 21.3 10.6 226 Btuh 2 Insulated - Exter 28.0 - 10.6 297 Btuh Door Total 49.3 523 Btuh Ceilings Type/Color R-Value Area HTM Load 1 Under Attic/Dark 30.0 1021.0 1.4 1429 Btuh Ceilinq Total 1021.0 1429 Btuh Floors Type R-Value Size HTM Load 1 Slab -On -Grade Edge Insulation 0.0 102.0 ft(p) 0.0 0 Btuh Floor Total 102.0 0 Btuh Infiltration Type ACH Volume CFM= Load Natural 0.35 20632 120.6 1990 Btuh Mechanical 0 0 Stun Infiltration Total 121 1 1990 Btuh Internal Occupants Btuh/occupant Appliance Load gain 1 6 X 300 + 3200 5000 Btuh EnergyGauge® FLRCPB v3.30 Manual J Summer Calculations Residential Load - Component Details (continued) Anchor Bay Development Project Title: Code Only Ocean Bay Villas Cocoplum Professional Version Climate: Central 7/1 /2004 Subtotal 35943 Btuh Duct gain(using duct multiplier of 0.10) 3594 Btuh Total sensible gain 39537 Btuh Totals for Cooling Latent infiltration gain (for 62 gr, humidity difference) 5084 Btuh Latent occupant gain (6 people @ 230 Btuh per person) 1380 Btuh Latent other gain 0 Btuh TOTAL GAIN 46002 Btuh Key: Window types (SHGC - Shading coefficient of glass as SHGC numerical value or as clear or tint) (U - Window U-Factor or'DEF' for default) (InSh - Interior shading device: none(N), Blinds/Daperies(B) or Roller Shades(R)) (ExSh - Exterior shading device: none(N) or numerical value) (Omt - compass orientation) EnergyGaugeO FLRCPB v3.30 System Sizing Calculations - Winter Residential Load Component Details Anchor Bay Development Project Title: Code Only Ocean Bay Villas Cocoplum Professional Version Climate: Central Reference City: Fort Pierce (Defaults) Winter Temperature Difference: 28.0 F 7/1/2004 Window Panes/SHGC/Frame/U Orientation Area X HTM= Load 1 1, Tint, Metal, 1.00 W 192.0 28.0 5376 Btuh 2 1, Tint, Metal, 1.00 W 32.8 28.0 918 Btuh 3 1, Tint, Metal, 1.00 W 49.0 28.0 1372 Btuh 4 1, Tint, Metal, 1.00 W 18.6 28.0 521 Btuh 5 1, Tint, Metal, 1.00 E 49.8 28.0 1394 Btuh 6 1, Tint, Metal, 1.00 E 12.6 28.0 353 Btuh 7 1, Tint, Metal, 1.00 E 26.4 28.0 739 Btuh 8 1, Tint, Metal, 1.00 N 16.6 28.0 465 Btuh 9 1, Tint, Metal, 1.00 N 49.8 28.0 1394 Btuh 10 1, Tint, Metal, 1.00 N 16.6 28.0 465 Btuh 11 1, Tint, Metal, 1.00 N 33.2 28.0 930 Btuh 12 1, Tint, Metal, 1.00 N 22.0 28.0 616 Btuh Window Total 519 14543 Btuh Walls Type R-Value Area X HTM= Load 1 Frame - Adjacent 11.0 191 1.8 344 Btuh 2 Concrete - Exterior 5.0 2202 4.0 8808 Btuh Wall Total 2393 9152 Btuh Doors Type Area X HTM= Load 1 Insulated -Adiac 21 9.4 200Btuh 2 Insulated - Exter 28 13.2 368 Btuh Door Total 49 569Btuh Ceilings Type R-Value Area X HTM= Load 1 Under Attic 30.0 1021 0.9 919 Btuh Ceilinq Total 1021 919Btuh Floors Type R-Value Size X HTM= Load 1 Slab -On -Grade Edge Insul 0 102.0 ft(p) 22.7 2315 Btuh Floor Total 102 2315 Btuh Infiltration Type ACH X Building Volume CFM= Load Natural 0.40 20632(sgft) 138 4245 Btuh Mechanical 0 0 Btuh Infiltration Total 138 4245 Btuh Subtotal 31743 Btuh Totals for Heating Duct Loss(using duct multiplier of 0.05) 1587 Btuh Total Btuh Loss 33330 Btuh EnergyGaugeO FLRCPB v3.30 Manual J Winter Calculations Residential Load. - Component Details (continued) Anchor Bay Development Project Title: Code Only Ocean Bay Villas Cocoplum Professional Version Climate: Central 7/1/2004 Key: Window types (SHGC - Shading coefficient of glass as SHGC numerical value or as clear or tint) (Frame types - metal, wood or insulated metal) (U - Window U-Factor or'DEF' for default) (HTM - ManualJ Heat Transfer Multiplier) Key: Floor size (perimeter(p) for slab -on -grade or area for all other floor types ) EnergyGauge(D FLRCPB v3.30 FORM 60OA-2001 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A Project Name: Ocean Bay Villas Azalea Builder: Address: Permitting Office: Port St. Lucie City, State: Permit Number: Owner: Anchor Bay Development Jurisdiction Number: 661200 Climate Zone: Central I. New construction or existing New _ 2. Single family or multi -family Multi -family _ 3. Number of units, if multi -family 3 _ 4. Number of Bedrooms 3 _ 5. Is this a worst case? Yes _ 6. Conditioned floor area (ft') 2171 ft' 7. Glass area & type Single Pane Double Pane a. Clear glass, default U-factor 16.6 ft' 0.0 ft' b. Default tint 373.0 ft' 0.0 ft' c. Labeled U or SHGC 0.0 ft' 0.0 111 8. Floor types a Slab -On -Grade Edge Insulation R=0.0, 104.0(p) It b. N/A _ c. N/A 9. Wall types a. Frame, Wood, Adjacent R=11.0, 325.0 fR _ b. Concrete, Int Insul, Exterior R=5.0, 1123.0 W c. NIA d. N/A e. N/A 10. Ceiling types _ a. Under Attic R=30.0, 900.0 ft' b. N/A c. N/A 11. Ducts _ a. Sup: Unc. Ret: Con. AH(Sealed):Interior Sup. R=6.0, 30.0 It _ b. N/A 12. Cooling systems a. Central Unit b. N/A c. N/A 13. Heating systems a. Electric Heat Pump b. NIA c. NIA 14. Hot water systems a. Electric Resistance b. NIA c. Conservation credits (HR-Heat recovery, Solar DHP-Dedicated heat pump) 15. HVACcredits (CF-Ceiling fan, CV -Cross ventilation, HF-Whole house fan, PT -Programmable Theanostat, MZ-C-Multizone cooling, MZ-H-Multizone heating) Glass/Floor Area: 0.18 Total as -built points: 28308 PASS Total base points: 28941 I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. PREPARED BY: DATE: I hereby certify that this buitdin as'designed, is in compliance with the Florida Ene OWNER/AGENT: - DATE: Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. BUILDING OFFICIAL: DATE: Cap: 60.0 kBtu/hr SEER: 10.20 Cap: 34.0 kBtu/hr _ HSPF: 7.20 Cap: 50.0 gallons _ EF: 0.89 PT, ADDRESS: , , . PERMIT #: BASE AS -BUILT GLASS TYPES .18 X Conditioned X BSPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X SPM X SOF = Points .18 2171.0 25.78 10074.3 Single, Tint E 1.5 28.2 32.8 53.27 1.00 1741.9 Single, Tint E 1.5 18.2 49.0 53.27 1.00 2597.8 Single, Tint E 1.5 6.3 49.0 53.27 0.93 2415.4 Single, Tint E 5.0 8.7 51.0 53.27 0.69 . 1871.5 Single, Clear E 5.0 5.3 16.6 63.97 0.55 579.7 Single, Tint W 4.0 3.3 7.3 47.90 0.50 174.5 Single, Tint W 1.5 22.7 11.8 47.90 1.00 563.2 Single, Tint W 1.5 6.3 16.6 47.90 0.92 735.0 .. Single, Tint W 1.5 11.0 23.6 47.90 0.99 1085.6 Single, Tint W 4.0 10.3 59.5 47.90 0.81 2322.0 Single, Tint S 8.0 10.0 56.0 39.84 0.60 1332.3 Single, Tint S 8.0 8.0 17.0 39.84 0.57 383.2 As -Built Total: 389.6 15802.1 WALL TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Adjacent 325.0 0.70 227.5 Frame, Wood, Adjacent 11.0 325.0 0.70 227.5- Exterior 1123.0 1.90 2133.7 Concrete, Int Insul; Exterior 5.0 1123.0 1.00 1123.0 Base Total: 1448.0 2361.2 As -Built Total: 1448.0 1350.5 DOOR TYPES Area X BSPM = Points Type Area X SPM = Points Adjacent 21.3 1.60 34.1 Adjacent Insulated 21.3 1.60 34.1 Exterior 28.0 4.80 134.4 Exterior Insulated 28.0 4.80 134.4 Base Total: 49.3 168.5 As -Built Total: 49.3 168.5 CEILING TYPES Area X BSPM = Points Type R-Value Area X SPM X SCM = Points Under Attic 900.0 2.13 1917.0 Under Attic 30.0 900.0 2.13 X 1.00 1917.0 Base Total: 900.0 1917.0 As -Built Total: 900.0 1917.0 FLOOR TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Slab 104.0(p) -31.8 -3307.2 Slab -On -Grade Edge Insulation 0.0 104.0(p -31.90 -3317.6 Raised 0.0 0.00 0.0 Base Total: -3307.2 As -Built Total: 104.0 -3317.6 EnergyGauge® DCA Form 60OA-2001 EnergyGaugeWlaRES2001 FI_RCPB v3.30 FORM 60OA-2001 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details I ADDRESS: , , , PERMIT #: BASE AS -BUILT INFILTRATION Area X BSPM = Points Area X SPM = Points 2171.0 14.31 31067.0 2171.0 14.31 31067.0 Summer Base Points: 42280.8 Summer As -Built Points: 46987.5 Total Summer Points X System = Multiplier Cooling Points Total X Component Cap Ratio X Duct X System X Multiplier Multiplier (DM x DSM x AHU) Credit Multiplier = Cooling Points 42280.8 0.4266 18037.0 46987.5 46987.5 1.000 1.00 (1.079 x 1.150 x 0.85) 0.334 1.061 0.334 0.950 0.950 15832.4 15832.4 EnergyGaugeTM DCA Form 600A-2001 EnergyGaugeDIFIaRES'2001 FLRCPB v3.30 FORM 60OA-2001 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , , , PERMIT #: BASE AS -BUILT GLASS TYPES .18 X Conditioned X BWPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X WPM X WOF = Points .18 2171.0 5.86 2290.0 Single, Tint E 1.5 28.2 32.8 13.04 1.00 428.4 Single, Tint E 1.5 18.2 49.0 13.04 1.00 640.7 Single, Tint E 1.5 6.3 49.0 13.04 1.02 649.2 Single, Tint E 5.0 8.7 51.0 13.04 1.08 716.0 Single, Clear E 5.0 5.3 16.6 12.37 1.15 236.5 Single, Tint W 4.0 3.3 7.3 13.80 1.09 110.3 Single, Tint W 1.5 22.7 11.8 13.80 1.00 162.7 Single, Tint W 1.5 6.3 16.6 13.80 1.01 231.2 Single, Tint W 1.5 11.0 23.0 13.80 1.00 317.4 Single, Tint W 4.0 10.3 59.5 13.80 1.03 844.4 _ Single, Tint S 8.0 10.0 56.0 10.88 1.66 1013.9 Single, Tint S 8.0 8.0 17.0 10.88 1.84 340.1 As -Built Total: 389.6 5690.9 WALL TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Adjacent 325.0 1.80 585.0 Frame, Wood, Adjacent 11.0 325.0 1.80 585.0 Exterior 1123.0 2.00 2246.0 Concrete, Int Insul, Exterior 5.0 1123.0 2.90 3256.7 Base Total: 1448.0 2831.0 As -Built Total: 1448.0 3841.7 DOOR TYPES Area X BWPM = Points Type Area X WPM = Points Adjacent 21.3 4.00 85.2 Adjacent Insulated 21.3 4.00 ' 85.2 Exterior 28.0 5.10 142.8 Exterior Insulated 28.0 5.10 142.8 Base Total: 49.3 228.0 As -Built Total: 49.3 228.0 CEILING TYPES Area X BWPM = Points Type R-Value Area X WPM X WCM = Points Under Attic 900.0 0.64 576.0 Under Attic 30.0 900.0 0.64 X 1.00 576.0 Base Total: 900.0 576.0 As -Built Total: 900.0 576.0 FLOOR TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Slab 104.0(p)-1.9 -197.6 Slab -On -Grade Edge Insulation 0.0 104.0(p 2.50 260.0 Raised 0.0 0.00 0.0 Base Total: -197.6 - As -Built Total: 104.0 260.0 EnergyGaugeg) DCA Form 60OA-2001 EnergyGaugeO/FlaRES'2001 FLRCPB v3.30 FORM 60OA-2001 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , , , PERMIT #: BASE AS -BUILT INFILTRATION Area X BWPM = Points Area X WPM = Points 2171.0 -0.28 -607.9 2171.0 -0.28 -607.9 Winter Base Points: 5119.5 Winter As -Built Points: 9988.7 Total Winter X Points System Multiplier = Heating Points Total X Component Cap Ratio X Duct X System X Multiplier Multiplier (DM x DSM x AHU) Credit Multiplier = Heating Points 5119.5 0.6274 3212.0 9988.7 9988.7 1.000 1.00 (1.068 x 1.16D x 0.87) 0.474 1.083 0.474 0.950 0.950 4870.5 4870.5 EnergyGaugeT. DCA Form 60OA-2001 EnergyGaugeS/FIaRES'2001 FLRCPB v3.30 FORM 60OA-2001 WATER HEATING & CODE COMPLIANCE STATUS Residential Whole Building Performance Method A - Details ADDRESS: , , , PERMIT #: BASE AS -BUILT WATER HEATING Number of X Multiplier = Total Tank EF Number of X Tank X Multiplier X Credit = Total Bedrooms Volume Bedrooms Ratio Multiplier 3 2564.00 7692.0 50.0 0.89 3 1.00 2535.19 1.00 7605.6 As -Built Total: 7605.6 CODE COMPLIANCE STATUS BASE AS -BUILT Cooling + Heating + Points Points Hot Water Points = Total Points Cooling Points + Heating + Hot Water = Total Points Points Points 18037 3212 7692 28941 15832 4871 7606 28308 I EnergyGaugeTM DCA Form 60OA-2001 EnergyGaugeD/FlaRES'2001 FLRCPB Q.30 FORM 60OA-2001 Code Compliance Checklist Residential Whole Building Performance Method A - Details ADDRESS: , , , PERMIT #: 6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS I SECTION I REQUIREMENTS FOR EACH PRACTICE CHECK Exterior Windows & Doors 606.1.ABC.1.1 I Maximum:.3 cfm/s .ft. window area; .5 cfm/s .ft. door area. Exterior & Adjacent Walls 606.1.ABC.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; foundation & wall sole or sill plate; joints between exterior wall panels at comers; utility penetrations; between wall panels & top/bottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from and is sealed to the foundation to the top plate. Floors 606.1.ABC.1.2.2 Penetrations/openings >118" sealed unless backed by truss orjoint members. EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed to the perimeter, penetrations and seams. Ceilings 606.1.ABC.1 2.3 Between wails & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter, at penetrations and seams. Recessed Lighting Fixtures 606.1.ABCA 2.4 Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a sealed box with 1/2" clearance & 3" from insulation; or Type IC rated with < 2.0 cfm from conditioned space tested. Multi -story Houses 606.1.ABC.1.2.5 Air barneron perimeter of floor cavity between floors. Additional Infiltration regts 606.1.ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, have combustion air. RA_99 r)THFP PP FfiCPIPTIVF MFASI IR FS Imucf he met nr excpprlerl by all recidenrac.l COMPONENTS I SECTION I REQUIREMENTS 1 CHECK Water Heaters 612.1 Comply with efficiency requirements in Table 6-12. Switch or clearly marked circuit breaker (electric) or cutoff (gas) must be provided. External or built-in heat traD required. Swimming Pools & Spas 612.1 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a pump timer. Gas spa & pool heaters must have a minimum thermal efficiency of 78%. _ Shower heads 612.1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. 1 Air Distribution Systems _ 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically attached, sealed, insulated, and installed in accordance with the criteria of Section 610. Ducts in unconditioned attics: R-6 min. insulation. HVAC Controls 607.1 Separate readily accessible manual or automatic thermostat for each Insulation 604.1, 602.1 Ceilings -Min. R-19. Common walls -Frame R-11 or CBS R-3 both sides. Common ceiling & floors R-11. M I ./ EnergyGaugeT" DCA Form 60DA-2001 EnergyGauge'&/FlaRES'2001 FLRCPB v3.30 ENERGY PERFOR FIANCE LEVEL, (EPL) ESTIMATED ENERGY PERFORMANCE SCORE* = 835 The higher the score, the more efficient the home. I. New construction or existing 2. Single family or multi -family 3. Number of units, if multi -family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft') 7. Glass area & type Single Pane a. Clear -single pane 16.6 ft' b. Clear- double pane 373.0 ft' c. Tint/other SHGC - single pane 0.0 ft' d. Tintlother SHGC - double pane 8. Floor types a. Slab -On -Grade Edge Insulation b. NIA c. N/A 9. Wall types a. Frame, Wood, Adjacent b. Concrete, Int Insul, Exterior c. N/A d. N/A e. N/A 10. Ceiling types a. Under Attic b. N/A c. NIA 11. Ducts a. Sup: Unc. Red Con. AH(Sealed):Interior b. N/A Anchor Bay Development, , , , New _ 12. Cooling systems Multi -family _ a. Central Unit 3 _ 3 _ b. N/A Yes _ 2171 ft' c. N/A Double Pane 0.0 ft' _ 13. Heating systems 0.0 ft' _ a. Electric Heat Pump 0.0 ft' _ b. N/A R=0,0, 104.0(p) ft R=11.0, 325.0 ft' R=5.0, 1 123.0 ft' R=30.0, 900.0 ft' _ Sup. R=6.0, 30.0 ft c. N/A 14. Hot water systems a. Electric Resistance b. N/A c. Conservation credits (HR-Heat recovery, Solar DHP-Dedicated heat pump) 15. HVAC credits (CF-Ceiling fan, CV -Cross ventilation, HF-Whole house fan, PT -Programmable Thermostat, MZ-C-Multizone cooling, MZ-H-Multzone heating) I certify that this home has complied with the Florida Energy Efficiency Cnr1e Fnr Rnildma Construction through the above energy saving features whit ill be insts in this home before £mat insp %e3tr ise Dis lay Card bated on installed C Builder S ; c Date: 11 Address of New Home: 11,q WC14NS/ J6p, City/FL Zip: Cap: 60.0 kBtu/hr _ SEER: 10.20 _ Cap: 34.0 kBtu/hr _ HSPF: 7.20 _ Cap: 50.0 gallons EF: 0.89 PT, _ "NOTE: The homes estimated erergr• performance scare is only, available through the FLARES conrputerprogram. This is not a Building Energor Rating. If roar score is 80 or greater (or 86for a US EPA/DOE Enera,Star"rdesio ration), vour home mar qualify for energy eff cienc i mortgage (EEM) incentives if iyou obtain a Fla'ida Energy % Gauge Rating. Contact the Energy Gauge Hotline at 3211638-1492 orsee the Energy Gauge iveb site at 11invfsec.ucf edufa' information and a list of certified Raters. For iti nnation about Florida's Energ : Effciency Code For -Building Corrsh'uction, 'contact the Department of Contnnarim A(%ah s at 8501487-1824. EnergyGauge® (Version: FLRCPB 0.30) Summary Energy Cede results Residential Whole Building Performance Method A Anchor Bay Development Project Title: Code Only Ocean Bay Villas Azalea Professional Version Climate: Central 7/1/2004 Building Loads Base As -Built Summer: 42281 points Summer: 46983 points Winter: 5119 points Winter: 9989 points Hot Water: 6769 points Hot Water: 6769 points Total: 54169 points Total: 63745 points Energy Use Base As -Built Cooling: 18037 points Cooling: 15832 points Heating: 3212 points Heating: 4871 points Hot Water: 7692 points Hot Water: 7606 points Total: 28941 points Total: 28308 points PASS e-Ratio: 0.98 EnergyGauge®(Version: FLRCPB v3.30) Anchor Bay Development Project Title: Code Only Ocean Bay Villas Azalea Professional Version Climate: Central 711 )Onnn Location for weather data: Fort Pierce - Defaults: Latitude(27) Temp Range(L) Humidity data: Interior RH (50%) Outdoor wet bulb 78F Humidity difference 62 r. Winter design temperature 42 F Summer design temperature 90 F Winter setpoint 70 F Summer setpoint 75 F Winter temperature difference 28 F Summer temperature difference 15 F Total heating load calculation 33746 Btuh Total cooling load calculation 55485 Btuh Submitted heating capacity % of calc Btuh Submitted cooling capacity - % of calc Btuh Total (Electric Heat Pump) 100.8 34000 Sensible (SHR = 0.7) 110.0 42000 Heat Pump + Auxiliary(O.OkW) 100.8 34000 Latent 1,04.0 18000 Total Electric Heat Pump) 108.1 60000 WINTER CALCULATIONS Winter Heatino Load (for 2171 soft Load component Load Window total 390 sqft 10909 Btuh Wall total 1448 sqft 5077 Btuh Door total 49 sqft 569 Btuh Ceiling total 900 sqft 810 Btuh Floor total 104 ft 2361 Btuh Infiltration 403 cfm 12413 . Btuh Subtotal 32139 Btuh Duct loss 1607 Btuh TOTAL HEAT LOSS 33746 Btuh Summer Coolino Load (for 2171 soft ,.,n(3�—) Ductsl55'.) -- �r�.e(,a) SUMMER CALCULATIONS Load component Load Window total 390 sgft 18805 Btuh Wall total 1448 sqft 2893 Btuh Door total 49 sqft 523 Btuh Ceiling total 900 sqft 1260 Btuh Floor total 0 Btuh Infiltration 378 cfm 6231 Btuh Internal gain 5000 Btuh Subtotal(sensible) 34712 Btuh Duct gain 3471 Btuh Total sensible gain 38183 Btuh Latent gain(infiltration) 15922 Btuh Latent gain(internal) 1380 Btuh Total latent gain 17302 Btuh TOTAL HEAT GAIN 55485 Btuh EnergyGaugeO ,ao�•s�s�ny JinnN2%) 11 .134`.:) c :) EnergyGaugeO System Si ' on ACCA Manual J. PREPARED BY: DATE: FLRCPB v3.30 System Sizing Calculations - Summer Residential Load - Component Details Anchor Bay Development Project Title: Code Only Ocean Bay Villas Azalea Professional Version Climate: Central Reference City: Fort Pierce (Defaults) Summer Temperature Difference: 15.0 F 7/1/2004 Type Overhang Window Area(sqft) HTM Load Window Panes/SHGC/U/InSh/ExSh Ornt Len Hot Gross Shaded Unshaded Shaded Unshaded 1 1, Tint, 1.00, N, N W 1.5 28.1 32.8 0.0 32.8 20 61 2001 Btuh 2 1, Tint, 1.00, N, N W 1.5 18.1 49.0 0.0 49.0 20 61 2989 Btuh 3 1, Tint, 1.00, N, N W 1.5 6.33 49.0 9.6 39.4 20 61 2594 Btuh 4 1, Tint, 1.00, N, N W 5 8.66 51.0 18.7 32.3 20 61 2342 Btuh 5 1, Clear, 1.00, N, N W 5 5.33 16.6 11.8 4.8 27 85 728 Btuh 6 1, Tint, 1.00, N, N E 4 3.33 7.3 7.3 0.0 20 61 147 Btuh 7 1, Tint, 1.00, N, N E 1.5 22.6 11.8 0.0 11.8 20 61 720 Btuh a 1, Tint, 1.00, N, N E 1.5 6.33 16.6 0.0 16.6 20 61 1013 Btuh 9 1, Tint, 1.00, N, N E 1.5 11 23.0 0.0 23.0 20 61 1403 Stun 10 1, Tint, 1.00, N, N E 4 10.3 59.5 5.4 54.1 20 61 3408 Btuh 11 1, Tint, 1.00, N, N N 8 10 56.0 0.0 56.0 20 20 1120 Btuh 12 1, Tint, 1.00, N, N N 8- 8 17.0 0.0 17.0 20 20 340 Btuh Window Total 390 18805 Btuh Walls Type R-Value Area HTM Load 1 Frame - Adjacent 11.0 325.0 1.3 422 Btuh 2 Concrete - Exterior 5.0 1123.0 2.2 2471 Btuh Wall Total 1448.0 2893 Btuh Doors Type Area HTM Load 1 Insulated -Adjac 21.3 10.6 226 Btuh 2 Insulated - Exter 28.0 10.6 297 Btuh Door Total 49.3 523 Btuh Ceilings Type/Color R-Value Area HTM Load 1 Under Attic/Dark" 30.0 900.0 1.4 1260 Btuh Ceilinq Total 900.0 1260 Btuh Floors Type R-Value Size HTM Load 1 Slab -On -Grade Edge Insulation 0.0 104.0 ft(p) 0.0 0 Btuh Floor Total 104.0 0 Btuh Infiltration Type ACH Volume CFM= Load Natural 0.35 30394 177.7 2931 Stun Mechanical 200 3300 Btuh Infiltration Total 378 1 6231 Btuh Internal Occupants Btuh/occupant Appliance Load gain 6 X 300 + 3200 5000 Btuh EnergyGauge® FLRCPB v3.30 Manual J Summer Calculations. Residential Load - Component Details (continued) Anchor Bay Development Project Title: Code Only Ocean Bay Villas Azalea Professional Version Climate: Central 7/1 /2004 Subtotal 34712 Btuh Duct gain(using duct multiplier of 0.10) 3471 Btuh Total sensible gain 38183 Btuh Totals for Cooling Latent infiltration gain (for 62 gr. humidity difference) 15922 Btuh Latent occupant gain (6 people @ 230 Btuh per person) 1390 Btuh Latent other gain 0 Btuh TOTAL GAIN 55485 Btuh Key: Window types (SHGC - Shading coefficient of glass as SHGC numerical value or as clear or tint) (U - Window U-Factor or'DEF' for default) (InSh - Interior shading device: none(N), Blinds/Daperies(B) or Roller Shades(R)) (ExSh - Exterior shading device: none(N) or numerical value) (Ornt - compass orientation) EnergyGaugeO FLRCPB v3.30 System Sizing Calculations ®Winter Residential Load - Component Details Anchor Bay Development Project Title: Code Only Ocean Bay Villas Azalea Professional Version Climate: Central Reference City: Fort Pierce (Defaults) Winter Temperature Difference: 28.0 F 7/1/2004 Window Panes/SHGC/Frame/U Orientation Area X HTM= Load 1 1, Tint, Metal, 1.00 W 32.8 28.0 918 Btuh 2 1, Tint, Metal, 1.00 W 49.0 28.0 1372 Btuh 3 1, Tint, Metal, 1.00 W 49.0 28.0 1372 Btuh 4 1, Tint, Metal, 1.00 W 51.0 28.0 1428 Btuh 5 1, Clear, Metal, 1.00 W 16.6 28.0 465 Btuh 6 1, Tint, Metal, 1.00 E 7.3 28.0 204 Btuh 7 1, Tint, Metal, 1.00 E 11.8 28.0 330 Btuh 8 1, Tint, Metal, 1.00 E 16.6 28.0 465 Btuh 9 1, Tint, Metal, 1.00 E 23.0 28.0 644 Btuh 10 1, Tint, Metal, 1.00 E 59.5 28.0 1666 Btuh 11 1, Tint, Metal, 1.00 N 56.0 28.0 1568 Btuh 12 1, Tint, Metal, 1.00 N 17.0 28.0 476 Btuh Window Total 390 10909 Btuh Walls Type R-Value Area X HTM= Load 1 Frame - Adjacent 11.0 325 1.8 585 Btuh 2 Concrete - Exterior 5.0 1123 4.0 4492 Btuh Wall Total 1448 5077 Btuh Doors Type • Area X HTM= Load 1 Insulated - Adjac 21 9.4 200 Btuh 2 Insulated - Exter 28 13.2 368 Btuh Door Total 49 569Btuh Ceilings Type R-Value Area X HTM= Load 1 Under Attic 30.0 900 0.9 810 Btuh Ceilino Total 900 8108tuh Floors Type R-Value Size X HTM= Load 1 Slab -On -Grade Edge Insul 0. 104.0 ft(p) 22.7 2361 Btuh Floor Total 104 2361 Btuh infiltration Type ACH X Building Volume CFM= Load Natural 0.40 30394(sgft) 203 6253 Btuh Mechanical 200 6160 Btuh Infiltration Total 403 12413 Btuh Subtotal 32139 Btuh Totals for Heating Duct Loss(using duct multiplier of 0.05) 1607 Btuh Total Btuh Loss 33746 Btuh EnergyGauge@ FLRCPB v3.30 Manual J Winter Calculations Residential Load - Component Details (continued) Anchor Bay Development Project Title: Code Only Ocean Bay Villas Azalea Professional Version Climate: Central 7/1/2004 Key: Window types (SHGC - Shading coefficient of glass as SHGC numerical value or as clear or tint) (Frame types - metal, wood or insulated metal) (U - Window U-Factor or'DEF' for default) (HTM - ManualJ Heat Transfer Multiplier) Key: Floor size (perimeter(p) for slab -on -grade or area for all other floor types ) EnergyGauge® FLRCPB Q.30 FORM 600A-2001 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Community Affairs Residential Whole Building Performance Method A Project Name: Ocean Bay Villas Beachberry I & II Builder: Address: Permitting Office: Port St. Lucie City, State: Permit Number: Owner: Anchor Bay Development Jurisdiction Number: 661200 Climate Zone: Central 1. New construction or existing New _ 2. Single family or multi -family Multi -family _ 3. Number of units, if multi -family 3 _ 4. Number of Bedrooms 3 _ S. Is this a worst case? Yes _ 6. Conditioned Floor area (ft') 2327 ft= 7. Glass area B& type Single Pane Double Pane _ a. Clear glass, default U-factor 0.0 ft' 0.0 ft, _ b. Default tint 494.7 fP 0.0 ft, c. Labeled U or SHGC 0.0 fP 0.0 ft' S. Floor types _ a. Slab -On -Grade Edge Insulation R=0.0, 102.0(p) ft _ b. N/A _ c. N/A 9. Wall types _ a. Frame, Wood, Adjacent R=11.0, 189.0 ft' b. Concrete, Int Insul, Exterior R=5.0, 2131.0 Fr' _ c. N/A _ d. N/A _ e. N/A 10. Ceiling types _ a. Under Attic R=30.0, 1030.0 ft' _ b. N/A c. NIA 11. Ducts a. Sup: Unc. Ret: Con. AH(Sealed):Interior Sup. R=6.0, 30.0 ft b. N/A 12. Cooling systems a. Central Unit b. N/A c. N/A 13. Heating systems a. Electric Heat Pump b. N/A c. N/A 14. Hot water systems a. Electric Resistance b. N/A c. Conservation credits (HR-Heat recovery, Solar DIP -Dedicated heat pump) 15. HVAC credits (CF-Ceiling fan, CV -Cross ventilation, HF-Whole house fan, PT -Programmable Thermostat, MZ-C-Multizone cooling, MZ-H-Multizone heating) Glass/Floor Area: 0.21 Total as -built points: 32083 PASS Total base points: 32365 I hereby certify that the plans and specifications covered by this calculation are in compliance with the Florida Energy Code. PREPARED BY: DATE: I hereby certify that this buil I , as designed, is in compliance with the Florida Energy C e. OWNER/AGENT: DATE: .9 Review of the plans and specifications covered by this calculation indicates compliance with the Florida Energy Code. Before construction is completed this building will be inspected for compliance with Section 553.908 Florida Statutes. BUILDING OFFICIAL: DATE: Cap: 60.0 kBtu/hr _ SEER: 10.20 Cap: 34.0 kBtu/hr HSPF: 7.20 Cap: 50.0 gallons EF: 0.89 PT, EnergyGaugeO (Version: FLRCPB v3.30) FORM 60OA-2001 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS: , , , PERMIT #: BASE I AS -BUILT GLASS TYPES .18 X Conditioned X BSPM = Points Floor Area Type/SC .18 2327.0 25.78 10798.2 Single, Tint Single, Tint Single, Tint ISingle, Tint - Sinale, Tint Single, Tint Single, Tint Single, Tint Single, Tint Single, Tint Single, Tint Single, Tint Single, Tint Single, Tint As -Built Total: :°dALL TYPES Area X BSPM = Points Type Adjacent 189.0 0.70 132.3 Frame, Wood, Adjacent Exterior 2131.0 1.90 4048.9 Concrete, Int Insul, Exterior Overhang Ornt Len Hgt Area X SPM X SOF = Points W 7.0 8.2 192.0 47.90 0.58 5318.9I W 1.5 28.0 32.8 47.90 1.00 1566.E W 1.5 18.0 49.0 47.90 1.00 If 2336.E W 1.5 6.3 49.0 47.90 0.92 2169.7 S 1.5 31.0 16.6 39.84 1.00 658.2 S 5.0 3.0 7.3 39.84 0.51 147.6 S 10.0 8.0 33.2 39.84 0.54 708.1 S 1.5 21.0 16.6 39.84 0.99 656.7 S 1.5 6.3 33.2 39.84 0.88 1165.4 S 1.5 4.3 5.2 39.84 0.79 163.1 S 1.5 7.5 9.3 39.84 0.92 339.5 E 3.0 7.3 32.8 53.27 0.80 1396.4 E 1.5 4.3 10.4 53.27 0.84 465.3 E 0.5 5.3 7.3 5327 0.99 386.7 494.7 17479.0 R-V21ue Area X SPM = Points 11.0 5.0 189.0 �2131.0 0.70 1.00 132.3 2131.0 Base Total: 2320.0 4181.2 As -Built Total: 2320.0 2263.3 DOOR TYPES Area X BSPM = Points Type Area X SPM = Points Adjacent Exterior 21.3 28.0 1.60 4.80 34.1 134.4 Adjacent Insulated Exterior Insulated 21.3 - 28.0 1.60 4.80 34.1 134.4 Base Total: 49.3 168.5 As -Built Total: 49.3 168.5 CEILING TYPES Area X BSPM = Points Type R-Value Area X SPM X SCM = Points Under Attic 1030.0 2.13 2193.9 Under Attic 30.0 1030.0 2.13 X 1.00 2193.9 Base Total: 1030.0 2193.9 As -Built Total: 1030.0 2193.9 FLOOR TYPES Area X BSPM = Points Type R-Value Area X SPM = Points Slab 102.0(p) -31.8 -3243.6 Slab -On -Grade Edge Insulation 0.0 102.0(p -31.90 -3253.8 Raised 0.0 0.00 0.0 Base Total: -3243.6 As -Built Total: 102.0 - -3253.8 EnergyGaugeO DCA Form 60OA-2001 ' EnerayGaugeO/FlaRES'2001 FLRCPB v3.30 FORM 60OA-2001 SUMMER CALCULATIONS Residential Whole Building Performance Method A - Details I ADDRESS: , , . PERMIT #: I BASE AS -BUILT INFILTRATION Area X BSPM = Points Area X SPM = Points 2327.0 14.31 33299.4 2327.0 14.31 33299.4 Summer Base Points: 47397.6 Summer As -Built Points: 52150.2 Total Summer . Points X System Multiplier = Cooling Points Total X I Component Cap Ratio X Duct X System X Multiplier 'Multiplier (DM x DSM x AHU) Credit Multiplier = Cooling Points 47397.6 0.4266 20219.8 52150.2 52150.2 1.000 1.00 (1.079 x 1.150 x 0.85) 0.334 1.061 0.334 0.950 0.950 17571.9 17571.9 EnergyGaugeT- DCA Form 60OA-2001 EnergyGauge®/FlaRES'2001 FLRCPB v3.30 FORM 60OA-2001 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS:. , , PERMIT #: BASE AS -BUILT GLASS TYPES .18 X Conditioned X BWPM = Points Overhang Floor Area Type/SC Ornt Len Hgt Area X WPM X WOF = Points .18 2327.0 5.86 2454.5 Single, Tint W 7.0 8.2 192.0 13.80 1.08 2854.7 Single, Tint W- 1.5 28.0 32.8 13.80 1.00 452.4 Single, Tint W 1.5 18.0 49.0 13.80 1.00 675.6 . Single, Tint W 1.5 6.3 '49.0 13.80 1.01 682.3 Single, Tint S 1.5 31.0 16.6 10.88 1.00 180.2 Single, Tint S 5.0 3.0 - 7.3 10.88 2.17 172.3 Single, Tint S 10.0 8.0 33.2 10.88 2.01 727.8 Single, Tint S 1.5 21.0 16.6 10.88 1.00 180.0 Single, Tint S 1.5 6.3 33.2 10.88 1.04 376.9 Single, Tint S 1.5 4.3 5.2 10.88 1.13 63.8 Single, Tint S 1.5 7.5 9.3 10.88 1.02 103.5 Single, Tint E 3.0 7.3 32.8 13.04 1.04 446.2 Single, Tint E 1.5 4.3 10.4 13.04 1.03 140.1 Single, Tint E 0.5 5.3 7.3 13.04 1.00 95.5 As -Built Total: 494.7 7151.3 WALL TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Adjacent 189.0 1.80 340.2 Frame, Wood, Adjacent 11.0 189.0 1.80 340.2 Exterior 2131.0 2.00 4262.0 Concrete, Int Insul, Exterior 5.0 2131.0 2.90 6179.9 Base Total: 2320.0 4602.2 As -Built Total: 2320.0 6520.1 DOOR TYPES Area X BWPM = Points Type Area X WPM = Points Adjacent 21L3 4.00 85.2 ,Adjacent Insulated 21.3 4.00 85.2 Exterior 28.0 5.10 142.8 Exterior Insulated 28.0 5.10 142.8 Base Total: 49.3 228.0 As -Built Total: 49.3 228.0 CEILING TYPES Area X BWPM = Points Type R-Value Area X WPM X WCM = Points Under Attic 1030.0 0.64 659.2 Under Attic 30.0 1030.0 0.64X 1.00 659.2 Base Total: 1030.0 659.2 As -Built Total: 1030.0 659.2 FLOOR TYPES Area X BWPM = Points Type R-Value Area X WPM = Points Slab 102.0(p) -1.9 -193.8 Slab -On -Grade Edge Insulation 0.0 102.0(p 2.50 255.0 Raised 0.0 0.00 0.0 Base Total:. -193.8 As -Built Total: 102.0 255.0 EnergyGauge® DCA Form 60OA-2001 EnergyGauge9)lFIaRES'2001 FLRCPB v3.30 FORM 60OA-2001 WINTER CALCULATIONS Residential Whole Building Performance Method A - Details ADDRESS:... PERMIT #: BASE AS -BUILT INFILTRATION Area X BWPM = Points Area X WPM = Points 2327.0 -0.28 -651.6 2327.0 -0.28 -651.6 Winter Base Points: 7098.6 Winter As -Built Points: 14162.0 Total Winter X o Points System Multiplier = Heating Points Total X Component Cap Ratio X Duct X System X Multiplier Multiplier (DM x DSM x AHU) Credit Multiplier = Heating Points I 7098.6 0.6274 4453.6 14162.0 14162.0 1.000 1.00 (1.068 x 1.160 x 0.87) 0.474 1.083 0.474 0.950 0.950 6905.5 6905.5 EnergyGaugeTM DCA Form 600A-M01 EnergyGaugeOlFlaRES'2001 FLRCPB v3.30 FORM 600A-2001 WATER HEATING & CODE COMPLIANCE STATUS Residential Whole Building Performance Method A - Details ADDRESS: , . , PERMIT #: I BASE AS -BUILT WATER HEATING Number of X Multiplier. = Total Tank EF Number of X Tank X Multiplier X Credit = Total Bedrooms Volume Bedrooms Ratio Multiplier 3 2564.00 7692.0 50.0 0.89 3 1.00 2535-19 1.00 7605.6 As -Built Total: 7605.6 CODE COMPLIANCE STATUS BASE AS -BUILT Cooling + Heating + Points Points Hot Water Points = Total Points Cooling Points + Heating + Hot Water = Total Points Points Points 20220 4454 7692 32365 17572 6905 7606 32083 EnergyGauge- DCA Form 60OA-2001 EnergyGauge`J(FlaRES'2001 FLRCPB v3.30 FORM 60OA-2001 Code Compliance Checklist Residential Whole Building Performance Method A - Details ADDRESS: , , , PERMIT #: 6A-21 INFILTRATION REDUCTION COMPLIANCE CHECKLIST COMPONENTS SECTION REQUIREMENTS FOR EACH PRACTICE I CHECK Exterior Windows & Doors 606.1.ABC.1.1 Maximum:.3 cfm/s .ft. window area; .5 cfm/s .ft. door area. Exterior & Adjacent Walls ( 606.1.ABC.1.2.1 Caulk, gasket, weatherstrip or seal between: windows/doors & frames, surrounding wall; foundation & wall sole or sill plate; joints between exterior wall panels at corners; utility penetrations; between wall panels & top/bottom plates; between walls and floor. EXCEPTION: Frame walls where a continuous infiltration barrier is installed that extends from, and is sealed to, the foundation to the top plate. Floors 606.1.ABC.1.2.2 Penetrations/openings >1/8" sealed unless backed by truss orjoint members. EXCEPTION: Frame floors where a continuous infiltration barrier is installed that is sealed . to the perimeter, penetrations and seams. Ceilings 606.1.ABC.1 2.3 Between walls & ceilings; penetrations of ceiling plane of top floor; around shafts, chases, soffits, chimneys, cabinets sealed to continuous air barrier; gaps in gyp board & top plate; 1 attic access. EXCEPTION: Frame ceilings where a continuous infiltration barrier is installed that is sealed at the perimeter, at penetrations and seams. Recessed Lighting Fixtures 606.1.ABC.1.2.4 Type IC rated with no penetrations, sealed; or Type IC or non -IC rated, installed inside a sealed box with 1/2" clearance & 3.' from insulation; or Type IC rated with < 2.0 cfm from conditioned space, tested. Multi -story Houses 606.1.ABC.1.2.5 Air barrier on perimeter of floor cavity between floors. Additional Infiltration roots 606.1.ABC.1.3 Exhaust fans vented to outdoors, dampers; combustion space heaters comply with NFPA, have combustion air. aA_99 r)TNFR PRFRCRIPTIVF fli FGRI IRFS (ni hp met nr ezrppriprl by all rpcirlpnrps_1 COMPONENTS I SECTION I REQUIREMENTS I CHECK _ Water Heaters 612.1 Comply with efficiency requirements in Table 6-12. Switch or clearly marked circuit J breaker electric or cutoff as must be provided. External or built-ih heat trap required. Swimming Pools & Spas '612.1 Spas & heated pools must have covers (except solar heated). Non-commercial pools must have a pump timer. Gas spa & pool heaters must have a minimum thermal efficiency of 78%. Shower heads 612.1 Water flow must be restricted to no more than 2.5 gallons per minute at 80 PSIG. Air Distribution Systems 610.1 All ducts, fittings, mechanical equipment and plenum chambers shall be mechanically ` f attached, sealed, insulated, and installed in accordance with the criteria of Section 610. Ducts in unconditioned attics: R-6 min. insulation. HVAC Controls 607.1 Separate readily accessible manual or automatic thermostat for each system. —� _ Insulation 604.1, 602.1 Ceilings -Min. R-19. Common walls -Frame R-11 or CBS R-3 both sides. _ I Common ceiling & floors R-11. - I EnergyGaugeTM DCA Form 60OA-2001 EnergyGauge®/FIaRES'2001 FLRCPB v3.30 ESTIMATED ENERGY PERFORMANCE SCORE* = 83.2 The higher the score, the more efficient the home. Anchor Bay Development, , , , 1. New construction or existing New _ 2. Single family or multi -family Multi -family 3. Number of units, if multi -family 3 _ 4. Number of Bedrooms 3 _ 5. Is this a worst case? Yes _ 6. Conditioned floor area (ft) 2327 W 7. Glass area & type Single Pane Double Pane a. Clear - single pane 0.0 fe 0.0 ft' b. Clear - double pane 494.7 ft' 0.0 ft' c. Tint/other SHGC - single pane 0.0 ft3 0.0 ft, _ d. Tint/other SHGC- double pane 8. Floor types a. Slab -On -Grade Edge Insulation R=0.0, 102.0(p) ft b. N/A _ c. N/A 9. Wall types a. Frame, Wood, Adjacent R=11.0, 189.0 W b. Concrete, Int Insul, Exterior R=5.0, 2131.0 ft' _ c. N/A _ d. N/A _ e. WA 10. Ceiling types _ a. Under Attic R=30.0, 1030.0 ft' _ b. N/A _ c. N/A 11. Ducts a. Sup: Unc. Ret Con. AH(Sealed): Interior Sup. R=6.0, 30.0 ft _ b. N/A 12. Cooling systems a Central Unit b. N/A a N/A 13. Heating systems a. Electric Heat Pump b. N/A c. N/A 14. Hot water systems a. Electric Resistance b. N/A c. Conservation credits (HR-Heat recovery, Solar DHP-Dedicated heat pump) 15. HVAC credits (CF-Ceiling.fan, CV -Cress ventilation, HF-Whole house fan, PT -Programmable Thermostat, MZ-C-Multizone cooling, MZ-H-Multizone heating) I certify that this home has complied with the Florida Energy Efficiency Code For Building Construction through the above energy saving features a%hv h will be installed (or exceeded) in this home before final in c ' the e , L Display Card will be completed based on installe Bui tgnature: Date: Address of New Home: Cap: 60.0 kBtu/hr SEER: 10.20 Cap: 34.0 kBtu/hr HSPF: 7.20 Cap: 50.0 gallons EF: 0.89 PT, _ "NOTE: The home's estimated energ t%petfa•mance score is 0711y available through the FLARES computer program. This is not a Building Energy Rating. if %our score is 80 m• greater (or 86 far a USEPA/DOE EnergyStarr"rdesignationJ, , your home rnar gualf,67 for energy efficiency ntor(;age (EEA7) incentives ijpou obtain a Florida Enera % Gauge Rating. Contact the Ener t% Gauge Hotline at 3211638-1492 or see the Energy Gauge web site at unto fsec.ucf edu for it formation and a list ofcertifeed Raters. For information about Florida's Enera %E ciencr Code For B,dlding Construction, contact the Depctrtnlent of CamnrtnitvAffairs at 8501487-1824. EnergyGauge® (Version: FLRCPB 03.30) Summary Energy Code Results Residential Whole Building Performance Method A Anchor Bay Development Project Title: Code Only Ocean Bay Villas Beachberry I & II Professional Version Climate: Central 7/1/2004 Building Loads Base As -Built E Summer:. I 94+7398 points Summer: 52150 points I Winter: 7099 points Winter: 14162 points Hot Water: 6769 points Hot Water: 6769 points Total: 61265 points I Total: 73031 points Energy Use Base As -Built Cooling: 20220 points Cooling: 17572 points Heating: 4454 paints Heating: 6905 points Hot Water: 7692 points Hot Water: 7606 points Total: 32365 points Total: 32083 points PASS e-Ratio: 0.99 EnergyGauge®(Version: FLRCPB v3.30) Residential System Sizing Calculation Summary Anchor Bay Development Project Title: Code Only Ocean Bay Villas Beachberry I & II Professional Version Climate: Central 9„ rh/1r, A Location for weather data: Fort Pierce - Defaults: Latitude(27) Temp Range(L) Humidity data: Interior RH (50%) Outdoor wet bulb 78F Humidity difference 62 r. Winter design temperature 42 F Summer design temperature 90 F Winter setpoint 70 F Summer setpoint 75 F Winter temperature difference 28 F Summer temperature difference 15 F Total heating load calculation 34891 Btuh Total cooling load calculation 47255 Stuh Submitted heating capacity % of calc Btuh Submitted cooling capacity % of calc Btuh Total (Electric Heat Pump) 97.4 34000 Sensible (SHR = 0.7) 111.0 42000 Heat Pump + Auxiliary(O.OkVV) 97.4 34000 Latent 191.3 18000 Total Electric Heat Pump) 127.0 60000 WINTER CALCULATIONS Winter HP.atlnn I narl (fnr 2327 Gnfl) Load component Load Window total 495 sqft 13852 Btuh Wall total 2320 sqft 8864 Btuh Door total 49 sqft 569 Btuh Ceiling total 1030 sqft 927 Btuh Floor total 102 ft 2315 Btuh Infiltration 218 cfm 6703 Btuh Subtotal 33230 Btuh Duct loss 1661 Btuh TOTAL HEAT LOSS 34891 Btuh Summer Cooling Load (for 2327 soft imnn, oon,�av � flnmN'%j N"d.,s(40%) iff Vl405�L]`n) SUMMER CALCULATIONS Load component Load Window total 495 sqft 19366 Btuh Wall total 2320 sqft 4934 Btuh Door total 49 sqft 523 Btuh Ceiling total 1030 sqft 1442 Btuh Floor total 0 Btuh Infiltration 190 cfm 3142 Btuh Internal gain 5o00 Btuh Subtotal(sensible) 34406 Btuh Duct gain 3441 Btuh Total sensible gain 37847 Btuh Latent gain(infiltration) 8028 Btuh Latent gain(internal) 1380 Btuh Total latent gain 9408 Btuh TOTAL HEAT GAIN 47255 Btuh imam imernm(� EnergyGaugeOO System Sizing based on ACCA Manual J. PREPARED BY: DATE: W- EnergyGaugeO FLP.CPB v3.30 System Sizing Calculations - Summer Residential Load - Component Details Anchor Bay Development Project Title: Code Only Ocean Bay Villas Beachberry I & II Professional Version Climate: Central Reference City: Fdrt Pierce (Defaults) Summer Temperature Difference: 15.0 F 7/1/2004 Type Overhang Window Area(sqft) HTM Load Window Panes/SHGC/U/InSh/ExSh Ornt Len Hot Gross Shaded Unshaded Shaded Unshaded 1 1, Tint, 1.00, N, N W 7 8.16 192.0 136.6 55.4 20 61 6112 etch 2 1, Tint, 1,00, N, N W 1.5 28 32.8 0.0 32.8 20 61 2001 Btuh 3 1, Tint, 1.00, N, N W 1.5 18 49.0 0.0 49.0 20 61 2989 Btuh 4 1, Tint, 1.00, N, N W 1.5 6.33 49.0 9.6 39.4 20 61 2594 Btuh 5 1, Tint, 1.00, N, N S 1.5 31 16.6 0.0 16.6 20 32 531 Etch 6 1, Tin:, 1.00, N, N S 5 3 7.3 7.3 0.0 20 32 146 Stun 7 1, Tint, 1.00, N, N S 10 8 33.2 33.2 0.0 20 32 I 664 Btuh 8 1, Tint, 1.00, N, N S 1.5 21 16.6 0.0 16.6 20 32 531 Btuh 9 1, Tint, 1.00, N. N S 1.5 6.33 33.2 33.2 0.0 20 32 664 Stuh 10 1, Tint, 1.00, N, N S 1.5 4.33 5.2 5.2 0.0 20 32 104 Btuh 11 1, Tint, 1.00, N. N S 1.5 7.5 9.3 9.3 0.0 20 32 186 Btuh 12 1, Tint, 1.00, N, N E 3 7.33 32.8 5.1 27.7 20 61 1793 Btuh 13 1, Tint, 1.00, N, N E 1.5 4.25 10.4 0.7 9.7 20 61 605 Etch 14 1, Tint, 1.00, N, N E 0.5 5.25 7.3 0.0 7.3 20 61 445 Btuh Window Total 495 19366 Btuh Walls Type R-Value Area HTM Loa d 1 - Adjacent 11.0 189.0 1.3 _ 246 Btuh 2 IFrame Concrete - Exterior 5.0 2131.0 2.2 4688 Stuh Wall Total 2320.0 4934 Btuh Doors Type Area HTM Load 1 Insulated -Adjac 21.3 10.6 226 Btuh 2 Insulated - Exter 28.0 10.6 297 Btuh Door Total 49.3 523 Stun Ceilings Type/Color R-Value Area HTM Load 1 Under Attic/Dark 30.0 1030.0 1.4 1442 Btuh Ceiling Total 1030.0 1442 Btuh Floors Type R-Value Size HTM Load 1 Slab -On -Grade Edge Insulation 0.0 102.0 ft(p) 0.0 0 Btuh Floor Total 102.0 0 Btuh Infiltration Type ACH Volume CFM= Load Natural 0.35 32578 190.4 3142 Btuh Mechanical 0 Btuh Infiltration Total _ _0 190 3142 Btuh Internal Occupants Btuh/occupant Appliance Load gain 1 6 X 300 + 3200 1 5000 Btuh EnergyGauge© FLRCPB v3.30 Manual J Summer Calculations Residential Load - Component Details (continued) Anchor Bay Development Project Title: Code Only Ocean Bay Villas Beachberry 13 II Professional Version Climate: Central 7/1/2004 Subtotal 34406 Btuh Duct gain(using duct multiplier of 0.10) 3441 Btuh Total sensible gain 37847 Btuh Totals for Cooling Latent infiltration gain (for 62 gr. humidity difference) 8028 Btuh Latent occupant gain (6 people @ 230 Btuh per person) 1380 Btuh Latent other gain I 0 Btuh Key: Window types (SHGC - Shading coefficient of glass as SHGC numerical value or as clear or tint) (U - Window U-Factor or'DEF for default) (InSh - Interior shading device: none(N), Blinds/Dapedes(B) or Roller Shades(R)) (ExSh - Exterior shading device: none(N) or numerical value) (Omt - compass orientation) EnergyGauge® FLRCPB v3.30 System Sizing Calculations - Winter Residential Load - Component Details Anchor Bay Development Project Title: Code Only Ocean Bay Villas Beachberry I & II Professional Version Climate: Central Reference City: Fort Pierce (Defaults) Winter Temperature Difference: 28.0 F 7/1/2004 Window Panes/SHGC/Frame/U Orientation Area X HTM= Load 1 1, Tint, Metal, 1.00 W 192.0 28.0 5376 Btuh 2 1, Tint, Metal, 1.00 W 32.8 28.0 918 Btuh 3 1, Tint, Metal, 1.00 W 49.0 28.0 1372 Btuh 4 1, Tint, Metal, 1.00 W 49.0 28.0 1372 Btuh 5 1, Tint, Metal, 1.00 S 16.6 28.0 465 Btuh 6 1, Tint, Metal, 1.00 S 7.3 28.0 204 Btuh ? 1, Tint, Metal, 1.00 S 33.2 28.0 930 Btuh 8 1, Tint, Metal, 1.00 S 16.6 28.0 465 Btuh 9 1, Tint, Metal, 1.00 S 33.2 28.0 930 Btuh 10 1, Tint, Metal, 1.00 S 5.2 28.0 146 Btuh 11 1, Tint, Metal, 1.00 S 9.3 28.0 260 Btuh 12 1, Tint, Metal, 1.00 E 32.8 28.0 918 Btuh 13 1, Tint, Metal, 1.00 E 10.4 28.0 291 Btuh 14 1, Tint, Metal, 1.00 E 7.3 28.0 204 Btuh Window Total 495 13852 Btuh Wails Type R-Value Area X HTM= Load 1 I Frame - Adjacent 11.0 189 1.8 340 Btuh 2 Concrete - Exterior 5.0 2131 4.0 I 8524 Btuh Wall Total 2320 l 8864 Btuh Doors Type Area X HTM= Load . 1 Insulated - Adjac 21 9.4 200 Btuh 2 Insulated - Exter 28 13.2 368 Btuh Door Total 49 569Btuh Ceilings Type R-Value Area X HTM= Load 1 Under.Attic 30.0 1030 0.9 927 Btuh Ceilina Total 1030 92713tuh Floors Type R-Value Size X HTM= Load 1 Slab -On -Grade Edge Insul 0 102.0 ft(p) 22.7 2315 Btuh Floor Total 102 2315 Stuh Infiltration Type ACH X Building Volume CFM= Load Natural 0.40 32578(sgft) 218 6703 Btuh Mechanical 0 0 Btuh Infiltration Total 218 6703 Btuh Subtotal 33230 Btuh Totals for Heating Duct Loss(using duct multiplier of 0.05) 1661 Btuh Total Btuh Loss 34891 Btuh EnergyGauge© FLRCPB Q.30 Manual J Winter Calculations Residential Load - Component Details (continued) Anchor Bay Development Project Title: Code Only Ocean Bay Villas Beachberry I & II Professional Version Climate: Central 7/1/2004 Key: Window types (SHGC - Shading coefficient of glass as SHGC numerical value or as clear or tint) (Frame types - metal, wood or insulated metal) (U - Window U-Factor or'DEF' for default) (HTM - ManualJ Heat Transfer Multiplier) Key: Floor size (perimeter(p) for slab -on -grade or area for all other floor types ) EnergyGaugeO FLRCPB Q.30