Loading...
HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCEPlanning & Development Services Department SC Building & Code Regulations Division ANNFO 2300 Certification for Design Load Compliance Virginia a6z-1ss3 St. �u%County Project Name: Pepper Park Boardwalks 1 through 8 Project Address: SR A-1-A, North Beach Pepper Park, St. Lucie County Permit#: Occupancy Type: Construction Type: INSTRUCTIONS FOR USE: This certification must be completed, signed, and sealed by the design professional of record. Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for Interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 2014 Building 5th Edition 1. DESIGN CODE: Florida g Code 20141Edition with 20 14 Supplements using ASCE 7-10 2. Structure Designed as (check one): _Enclosed _Partially Enclosed X open 3. Risk Category: _I X II _III _ IV Exposure Category: _B X—C _D 4. Design Wind Velocity 170 mph _ASD X LRFD End Zone Width: N/A ft 5. Mean Roof Height N/A ft Roof Pitch: NIA :12 Parapet: N/A ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): N/A Zone 1: 'Zone 2: Zone 3: Zone 4: Zone 5: Garage: 7. Design Loads: Floor: N/A PSF Roof/Dead: _N/A PSF Roof/Live: N/A Balcony: NIA PSF Dock: 30 PSF Deck: 90 PSF Stairs: N/A PSF Fence: N/A PSF Railings: 50Lb/LFpSF 8. Were Shear Walls Considered For Structure? _Yes XNot Applicable Explain Why Not: This is for a boardwalk which does not have walls I 9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not 10. Design Soil Bearing Pressure: See Below PSF Soil Test Reports Submitted? Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply,"�tirtfppppl'icable structural portions of the building codes currently adopted and enforced by St. Lucie COnraA? I d1lDfttifv &aSstructural elements depicted on these plans provide adequate resistance to the design �%-C lVX,% �.\� � `Sic•'• 1;�-pie Stefan K. Matthes Fla PE, 38723 CD UQ o 3 7I3 �* Q Print Name Cert # & Co. Cert Auth. e Culpepper & Terpening, Inc. 2980 South 25th Street, Ft. Pierce, F134981 Company Name &Address 3/15/12 (JS) Pile support design is based upon a conservative effective unit weight of 100 pcf - 62.4 pcf with a resultant 37.6 pcf, 28 degree friction angle and SPT blow count, N=5 blows/Ft. Planning & Development Services Department SCANNED Building & Code Regulations Division BY 2300 Virginia Avenue, Fort Pierce, FL 34982— (772) 462-1553 St. Lucie County Certification for Design Load Compliance Project Name: Pepper Park Boardwalks 1 through 8 Project Address: SR A-1-A, North Beach Pepper Park, St. Lucie County Permit#: Occupancy Type: Construction Type: INSTRUCTIONS FOR USE: * This certification must be completed, signed, and sealed by the design professional of record. o Submit (2) copies for residential, (3) copies for commercial with all permit applications Involving the following: o New Residences (single or multi -family) FILE o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 2014 Building 5th Edition 1. DESIGN CODE: Florida g Code 2-010-Edition with 20 14 Supplements using ASCE 7-10 2. Structure Designed as (check one): _Enclosed _Partially Enclosed X open 3. Risk Category: _I X II _III —IV Exposure Category: _B X C _D 4. Design Wind Velocity 170 mph _ASD X LRFD End Zone Width: N/A ft 5. Mean Roof Height N/A ft Roof Pitch: N/A :12 Parapet: N/A ft G. Components & Cladding Design Pressures Used: (PSF, based on SDsgft @ 15'MRH, clearly label on all plan openings): N/A Zone 1: Zone 2: Zone 3: Zone 4: Zone 5: Garage: 7. Design Loads: Floor: N/A PSF Roof/Dead: N/A PSF Roof/Live: N/A Balcony: N/A PSF Dock: 30- PSF Deck: 90 PSF Stairs: N/A PSF Fence: N/A PSF Railings: 50Lb/LFpSF 8, Were Shear Walls Considered For Structure? _Yes XNot Applicable Explain Why Not: This is for a boardwalk which does not have walls 9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not 10. Design Soil Bearing Pressure: See Below PSF Soil Test Reports Submitted? Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply wi`t�iyBl3N®afpb le structural portions of the building codes currently adopted and enforced by St. Lucie .%� CountvaIgl(AFAifv thaitaructural elements depicted on these plans provide adequate resistance to the design E NS< !Jyso� • Stefan K. Matthes Fla PE, 38723 3 723 ; N : Print Name Cert # & Co. Cent Auth. S •'_ i Culpepper &TerpeningInc. S and Se L • ��/ �� \2980 South 25th Street, Ft. Pierce, F134981 Company Name & Address SLCCDV F3/mr�Qf'`yViSFi33/15/12(JS)-.� Pile support design is based upon a conservative effective unit weight of 100 pcf - 62.4 pef with a resultant 37.6 pcf, 28 degree friction angle and SPT blow count, N=5 blows/Ft.