Fenestration
C402.27 Envelope
U-factor of opaque doors associated with the
El
El
thermal envelope meets requirements.
Insulation
C4022.1.1 Envelope
Highalbedo roofs satisfy one of the following:
®
�.
3-yearaged solar reflectance>= 0.55 and thermal
emittance>= 0.75, 3-yearaged solar reflectance
index >=64.0, initial year solar reflectance>=
0.70 and thermal emittance >= 0.75, or initial year
solar
Wattage
C405.6 Exterior Lighting
Exterior grounds lighting over 100 W provides>60
10
❑
❑
Im/W unless on motion sensor or fixture is exempt
from scope of axe or from external LPD.
Wattage
C405.4 Interior Lighting
Exit signs do not exceed 5 watts per face.
®
1-
E_
Wattage
C405.23 Interior Lighting
Additional interior lighfing power allowed for
special functions per the approved lighting plans
and is automatically controlled and separated
from general lighting.
HVAC
C403.2.6 Mechanical
Exhaust air energy recovery on systems meeting
9
El
Table C4032.6
SYSTEM —SPECIFIC
C403.3.1,C403.3.1.1 Mechanical
Air economizers provided where required, meet
®
11
❑
the requirements for design capacity, control
signal, ventilation controls, high -limit shut-off,
integrated economizer control, and provide a
means to relieve excess outside air during
operation.
SYSTE _SPECIFIC
C403.3.1,C403.4.1 Mechanical
Water economizers provided where required
meet the requirements for design capacity,
maximum pressure drop and integrated
economizer control.
SYSTEM —SPECIFIC
C403AAA Mechanical
Economizer operation will not increase heating
0
El
El
energy use during normal operation.
oorr
SYSTEM—SPECIFIC
C403.2.10.1 Mechanical
HVAC fan systems at design conditions do not
exceed allowable fan system motor nameplate hp
or fan system bhp.
SYSTEM SPECIFIC
C403.2.10.2 Mechanical
HVAC fan motors not larger than allowable limits.
11
El
SYSTEM —SPECIFIC
C404.2 Mechanical
Service water heating equipment meets efficiency11
1-1
requirements.
wr
SYSTEM —SPECIFIC
C403.2.3 Mechanical
Centrifugal fan openchcuit cooling towers having
®
/1
El
combined rated capacity >=1100 gpm meets
minimum efficiency requirement>=36.2 gpmmp.
2. To be checked by Plan Reviewer
1
Air Leakage
C402.4.7 Envelope
vestibules are installed on all building entrances.
❑
Doors have self -dosing devices.
Insulation
C402.2.6 Envelope
Slab edge insulation depthllength. Slab insulation
extending away from building is covered by
pavement or>=10 inches of soil.
Plan Review
C103.2 Envelope
Plans and/or specifications provide all information
❑
❑
with which compliance can be determined for the
building envelope and document where
z
_
exceptions to the standard are daimed.
RECEIVED
JUN 01 2018
yGaueq S�I��nYIt � 4�-� 1 . TAM 2014-1.0 Compliant Software. Effective Date: June 30, 2015
Florida y Conservation IECC 2012 - Total Building Performance Compliance Option