HomeMy WebLinkAboutPROJECT INFORMATIONNotes - Along Ridge Wind Pressure on Components and Cladding (Ch 30 Part 1) Lw-J: I I I I •, I 1 1 I Roof nor , 51ro�rn 5 SCANNED - 4_ 4i I I I BY �.' ' St. Lucie County =5 5, a _ I , a Gable Roof' .:: 0 •t= 45 All pressures shown are based upon ASD Design, with a Load Factor of .6 Width of Pressure Coefficient Zone "a° _ - 9.27 ft Deecription Width Span Area Zone Max Min Maw P Min P _______________________________________________________________________ ft ft ft"2 GCp GCp pef pef Zone 1 1.00 1.00 1.0 1 0.50 -0.90 21.14 -33.58 Zone 2 1.00 2.00 1.0 2 0.50 -1.70 21.14 -58.45 Zone 3 1.00 2.00 1.0 3 0.50 -2-60 21.14 -86.43 Zone 4 1.00 1.00 1.0 4 1.00 -1.10 36.69 -39-80 Zone 5 1.00 1.00 1.0 5 1.00 -1.40 36.69 -49.12 Zone 2H 1.00 2.00 1.0 2H 0.50 -2.20 15.55 -68.40 Zone 3H 1.00 1.00 1.0 3H 0-50 -3.70 15.55 -115.04 Khcc:Comp. 6 Clad. Table 6-3 Case 1 - 0.93 Qhcc:.00256•V^2-Khcc-Kht`Kd - 31.09 psf