HomeMy WebLinkAboutREACTION REPORTBUTLER
Shape: Manufacturing Shop
Builder Contact: Doug Davis
Name: Richard K. Davis Construction Corp.
Address: 4205 Metzger Rd
City, State Zip: Fort Pierce, Florida 34947
Country: United States
Loads and Codes - Shape: Manufacturing Shop
Reactions Report
Project: Seacoast Curbs
Builder PO N:
Jobsite: 2601 Industrial Avenue 3
City, State Zip: Fort Pierce, Florida 34945
County, Country: Saint Lucie, United States
Date: 8/ 11 /2017
Time: 12:13 PM
Page: I of 28
City: Fort Pierce County: Saint Lucie State: Florida Country: United States
Building Code: Florida Building Code-2014 Edition Structural: IOAISC-ASD Rainfall: 1: 0. 10 inches per hour
Based on Building Code: 2012 International Building Code Cold Form: 12AISI - ASD rc: 3000.00 psi Concrete
Building Risk/Occupancy Category: If (Standard Occupancy Structure)
Dead and Collateral Loads
Collateral Gmviry:5.00 psf Roof Covering + Second. Dead Load: 2.34 psf
Collateral Uplift: 0.00 psf Frame Weight (assumed for seismic):2.50 psf
Wind Load
Snow Load
Wind Speed: Volt: 160.00 (Vasd: 123.94) mph
Ground Snow Load: pg: 0.00 psf
The'Envelope Procedure is Used
Flat Roof Snow:, pC 0.00 psf
Wind Exposure: C - Kz: 0.882
Design Snow (Sloped): ps: 0.00 psf
Pans Wind Exposure Factor: 0,882
Rain Surcharge: 0,00
Wind Enclosure: Enclosed
Exposure Factor:2 Partially Exposed -Ce: 1.00
Topographic Factor: Kzl: 1.0000
Snow Importance: Is: 1.000
Thermal Factor: Heated - Cb 100
NOT Windbome Debris Region
Ground / Roof Conversion: 0.70
Base Elevation: 0/0/0
Primary Zone Strip Width: 2a: 14/4/13
Parts / Ponions Zane Strip Width: a: 7/216
Basic Wind Pressure: q: 49.14 psf
SCANNED
BY
St. Lucie County
Load Type Descriptions
D
Material Dead Weight
C
CG
Collateral Load for Gravity Cases
CU
L
Roof Live Load
ASLA
AASL
Alternate Span Live Load, Shifted Left
PL2
L>
Live -Notional Right
<L
S
Snow Load
USI-
•USI_ _
Unbalanced Snow Load I, Shifted Left
US20
•US2
_ _
Unbalanced Snow Load 2, Shifted Left
SD
SS
Sliding Snow Load
RS
PFI
Partial Load, Full, I Span
PHI
PF2
Partial Load. Full, 2 Spans
PH2
S>
Snow -Notional Right
<S
SMS
Specified Min. Roof Snow
SMS>
Roof Live Load
Roof Live Load: 20.00 psf Reducible
Seismic Load
Lateral Force Resisting Systems using Equivalent
Force Procedure
Mapped MCE Acceleration: Ss: 5.60 %g
Mapped MCE Acceleration: S I: 2.90 %g
Site Class: Stiff soil (D)
Seismic Importance: le: 1.000
Design Acceleration Parameter: Sits: 0.0597
Design Acceleration Parameter: Sit I: 0.0464
Seismic Design Category: A
Seismic Snow Load: 0.00 psf
Snow Used in Seismic: 0.00
Diaphragm Condition: Flexible
Fundamental Period Height Used: I8/0/0
Transverse Direction Parameters
System NOT detailed for Seismic
Redundancy Factor: Rho: 1.00
Fundamental Period: Ta: 0.2827
R-Factor: 3.00
Overstrength Factor: Omega: 2.50
Deflection Amplification Factor: Cd: 3.00
Base Shear: V: 0.0100 x W
Longitudinal Direction Parameters
System NOT detailed for Seismic
Redundancy Factor: Rho' 1.00
Fundamental Period: Ta: 0.1748
R-Factor: 3.00
Overstrength Factor: Omega: 2.50
Deflection Amplification Factor: Cd: 3.00
Base Shear: V: 0.0100 x W
Collateral Load
Collateral Load for Wind Cases
Alternate Span Live Load, Shifted Right
Partial Live, Full, 2 Spans
Live- Notional Left
Unbalanced Snow Load 1, Shifted Right
Unbalanced Snow Load 2, Shifted Right
Snow Drift Load
Rain Surcharge Load
Partial Load, Half, I Span
Partial Load, Half, 2 Spans
Snow - Notional Left
Specified Min. Roof Snow -Notional Right
Butler Advantage: 2.9.2.5
Butler Manufacturing, a division of BlueScope Buildings North America, Inc.
BUTLER
17-029856 - Letter of Certification
Date: 2/22/2018
Page: I of 2
Contact: Doug Davis Project: Seacoast Curbs V1 V$J
Name: Richard K. Davis Construction Corp. Builder PO #: f J eY Q
Address: 4205 Metzger Rd Jobsite: 2601 Industrial Avenue 3' JJ!`%.e C
U0 fi-
City, State: Fort Pierce, Florida 34947 City, Stale: Fort Pierce. Florida 34945 nY
Country: United States SCANNED County, Country: Saint Lucie, United States
This is to certify that the above referenced project has been ycSentiyned in accordance with the applicable portions of the Building Code specified below.
All loading and building design criteria shown b fv �-UUfC Speciclunp contract and applied in accordance with the building code.
fied
Overall Build"1 Desert tion tl 1, (51
Shape
Overall
Width
Overall
Length
Floor Area
(s . ft.)
Wall Area
(sq.I'L
Roof Area
(sq. ft.)
Max Eave
Height
Min. Eav0
Height2
Max. Roof
Pitch
Mint Roof
I Pitch
Peak
Height
Manufacturing Shop
13010/0
230/010 1
29900
1 13312
30109
1910/0
1810/0
0.500:12
1 0.500:12
7018/8
Total For All ShapesShapesl
29900
1 t3312
1 30109
Loads and Codes - Shape: Manufacturing Shop
City: Fort Pierce County: Saint Lucie State: Florida Country: United States
Building Code: 6th Edition (2017) Florida Building Code Structural: I OAISC - ASD Rainfall: 1: 11.00 inches per hour
Based on Building Code: 2015 International Building Code Cold Form: 12AISI - ASD fc: 3000.00 psi Concrete
Building Risk/Occupancy Category: II (Standard Occupancy Structure)
Dead and Collateral Loads
Collateral Gravity:5.00 psf Roof Covering+ Second. Dead Load: Varies
Collateral Uplift: 0.00 psf Frame Weight (for seismic):2.50 psf
Wind Load Snow Load
Wind Speed: Volt: 160.00 (Vasd: 123.94) mph Ground Snow Load: pg: 0.00 psf
The'All Heights' Method is Used
Wind Exposure: C - Kz: 0.882
Parts Wind Exposure Factor: 0.882
Wind Enclosure: Enclosed
Topographic Factor. KzC 1.0000
Hurricane Prone Region
Windborne Debris Region
Impact Resistant Covering
Base Elevation: 0/0/0
Primary Zone Strip Width: 2a: I8/0/0
Parts / Portions Zone Strip Width: a: 7/2/6
Basic Wind Pressure: if 49.14 psf
JUN 01 P';3
ST, Lucie County, per nitting
Flat Roof Snow: pC 0.00 psf
Design Snow (Sloped): ps: 0.00 psf
Rain Surcharge: 0.00
Exposure Factor: 2 Partially Exposed - Ce: 1.00
Snow Importance: Is: 1.000
Thermal Factor: Heated -Ct 1.00
Ground / Roof Conversion: 0.70
Load Notes
Collateral Load Note;
1. Collateral load is intended for uniformly distributed loads.
2. Collateral load does not cover heavy point loads.
3. If point loads exceeding 250lbs are applied to the structure a BMC review will be required.
Roof Live Load
Roof Live Load: 20.00 psf Reducible
Seismic Load
Lateral Force Resisting Systems using Equivalent
Force Procedure
Mapped MCE Acceleration: Ss: 5.60 %g
Mapped MCE Acceleration: SI: 2.90 %g
Site Class: Stiff soil (D)
Seismic Importance: le: 1.000
Design Acceleration Parameter: Sds: 0.0597
Design Acceleration Parameter: Sd 1: 0.0000
Seismic Design Category:. A
Seismic Snow Load: 0.00 psf
%Snow Used in Seismic: 0.00
Diaphragm Condition: Flexible
Fundamental Period Height Used: I M/0
Transverse Direction Parameters
System NOT detailed for Seismic
Redundancy Factor: Rho: 1.00
Fundamental Period: To: 0.0000
R-Factor: 3.00
Overstrength Factor: Omega: 2.50
Deflection Amplification Factor: Cd: 3.00
Base Shear: V: 0.0199 x W - USR
Longitudinal Direction Parameters
System NOT detailed for Seismic
Redundancy Factor: Rho: 1.00
Fundamental Period: Ta: 0.0000
R-Factor: 3.00
Overstrength Factor; Omega: 2.50 -
Deflection Amplification Factor:Cd: 3.00
Base Shear: V: 0.0199 x W - USR
File: 17-029856-01 Version: 2017.2c
Butler Manufacturing, a division of BlueScope Buildings North America, Inc.
surLER Date: 2/22/2018
adnermanH„.ta, 17-029856 - Letter of Certification Page: 2 of 2
Building design loads and governing building code is provided by the Builder and is not validated by Butler Manufacturing, a division of BlueScope
Buildings North America, Inc. The Builder is responsible for contacting the local Building Official or project Design Professional to obtain all code and loading
information for this specific building site.
The design of this building is in accordance with Butler Manufacturing, a division of BlueScope Buildings North America, Inc. design practices which have
been established based upon pertinent procedures and recommendations of the Standards listed in the Building Code or later editions.
This certification DOES NOT apply to the design of the foundation or other on -site structures or components not supplied by Butler Manufacturing, a division
of BlueScope Buildings North America, Inc., nor does it apply to unauthorized modifications to building components. Furthermore, it is understood that
certification is based upon the premise that all components will be erected orconstructed in strict compliance with pertinent documents for this project. Butler
Manufacturing, a division of BlueScope Buildings North America, Inc. DOES NOT provide general review of erection during or after building construction
unless specifically agreed to in the contract documents.
The undersigned engineer in responsible charge certifies that this building has been designed in accordance with the contract documents as indicated in this
letter.
Bobby Locklear Date: 2/26/2018 Engineer's Seed:
Engineer in responsible charge
t11111111
LQCKI
y
No.68504
it
9 •
�'PO $TAT£ Olr W
OR:D*
nit1����•
Bobby kk�qr
P.Q. Box 1529
Laurin". N.C. mw
Floe PE, / 68504
Bobby H. Locgear, PE
o.b'. 1, a been electrbnlaly 15ce4 ane sealed by Bobby H.
LaMleeS PEwing m C,brl 5rynaNre w FE mal a?nM. when
11.q dcrurrert'n bmted. Ne s1mbre m be verified Mb Re
eieobcn cc"
2
0+e-03 ie CB'.Z] ]a [Sca
File: 17-029856-01 Version: 2017.2c
Butler Manufacturing, a division of BlueScope Buildings North America, Inc.
SCANNED
BY
St. Lucie Countv
BUTLER
Change Order Acknowledgement
Date: 04/02/2018 Builder Contact : DOUG DAVIS
Builder P.O.
Bill To: RICHARD K. DAVIS CONSTRUCTION CORP. Ship To: RICHARD K. DAVIS CONSTRUCTION CORP.
PO BOX 186 2601 INDUSTRIAL AVENUE 3
FORT PIERCE, FL 34954-0186 FORT PIERCE, FL 34945
us US
Project Name
Order#
OE #
Customer#
Project Manager
Requested By
Department
SEACOAST CURBS
17-029856-01
17-029856-01
200911101
BENADEAU
Book Date: 03/1212018
Building Dimensions
Change Description
Order
Creation
Number
Date
Description
17-029856-01
04/02/2018
CHANGES AFTER CLARIFICATION - 04/02/18
Changes:
Add - 3 Sets Final Erection Drawings - S&S Cover page only. WET STAMP hard copy - B Size
drawings.
(See your pricing detail report for itemized pricing breakdowns)
ORIGINAL NET PRICE: $ 227,790.99
REV.INETPRICE: $226,066.27
REV. 2 NET PRICE: $ 226,816.27
5"-
Please review the changes described above and contact your Project Manager for additional
information if needed. Sign below to indicate your acceptance of the changes proposed that
are subject to the same terms and conditions as the original purchase order. Please return this
signed Change Order to your Project Manager within two days.
�" QaAF%';> 4 2 I a
Builder Co tact Date
01/25/2018
CHANGES AFTER CLARIFICATION-01/25/18
Changes:
IBC Building Code from IBC12 to EBC15
VSR II - canopy - removed thermal blocks, Color = Cool Emerald Green,
Changed Dim's of Canopy
Ridge assemby type from expandable to low profile
Omitted base angle
Gable, Eave and Gutter = Cool Emerald Green
Downspout = Cool Country Wheat
Add - perpendicular transition to masonry for window awning locations
Revised louver size and locations
Page 1 of 2
Butler Manufacturing, a division of BlueScope Buildings North America, Inc.
w
sure.eFr
Change Order Acknowledgement
Change Description
Order
Creation
Number
Date
Description
01/25/2018
(See your pricing detail report for itemized pricing breakdowns)
ORIGINAL NET PRICE: $ 227,790.99
REV. 1 NET PRICE: $ 226,066.27
AMOUNT OF CHANGE: ($1,724.72)
Order Summary Page
Order Number
Total Amount
17-029856-01
$226,066
17-029856-05
$750
18-023341-01
$2,315
Total Project billing after Discounts excluding tax and may exclude freight'
$229,132
Refer to current pricing for Guaranteed Freight that may be included in your billing amount.
Any Questions Regarding This Order — Please Contact Your Regional Project Manager
'""End Of Report"'
Page 2 of 2
Butler Manufacturing, a division of BlueScope Buildings North America, Inc.