HomeMy WebLinkAboutPROJECT INFORMATIONPAUL WELCH INC.
Mechanical * Electrical * Civil Engineering
1984 S.W. Biltmore St. Suite#114
Port Saint Lucie, FL 34984
Phone (772) 785 - 9888
Email pwelchinc@aol.com 1 �OQ __,,7 j_n of
September 19, 2017
Re: Door Replacement
9500 S. Ocean Dr. (1903)
Fort Pierce, FL
To Whom It May Concern:
ST. LUCIF. COLNTY ELILDING DTVLSIO
REVIEWED FOR CO. N
REVIEWED BY
DATE
PLANS AND PE_ IIT Al ST BE KEPT ON JOB
OR NO INSPECTION WILL BE ;1LADE.
SCANNED
BY
St. Lucie Cn, i^t,
Our office has calculated the required design pressure in accordance with ASCE 7-10 and
FBC 2014 for the replacement of the doors at the above referenced address.
Wind speed: Vwt: 165mph, Vad: 128 mph
Exposure: D
Enclosure Type: Enclosed
Door Size: Per Attached Sketch
Quantity of Doors: 2
Location: Per Attached Sketch
Required Design Pressure (Zone 4): +50.8/ -55.1 PSF Worst Case
Door to be installed shall be equal to, or exceed the required design pressures as listed
above. All installations shall be in accordance with FBC 2014 and manufacturer's
installation instructions.
Proposed Door: PGT Industries Inc. SGD-2500 GLASS TYPE "D"
NOA# 15-0609.10 (+65 / -65 PSF).
Thank you for your attention to this matter.
Submitted by:
PAUL WELCH
Paul Welch, P.E..
Reg. No 29945
THESE PLANS AND ALL PROPOSED WORK
ARE SUBJECT TO ANY CORRECTIONS
REQUIRED BY FIELD INSPECTORS THAT
MAY BE NECESSARY IN ORDER TO
COMPLY WITH ALL APPLICABLE CODES.
/ 0N003N 10 N01OWN00
3Nl 10 AlnIIISNOMN 3N138V
:1N303yLly UO SHOW 03IV30NOO
Attached: Area of Work Plan -
PAUL WELCH INC.
Mechanical * Electrical * Civil Engineering
1984 S.W. Biltmore St. Suite#114
Port Saint Lucie, FL 34984
Phone (772) 785 - 9888
Email pwelchinc@aol.com
Door Replacement
9500 S. Ocean Dr. (1903)
Fort Pierce, FL
r"
28 4
81
8
13 3F--��
EXISTING SHUTTERS AT
BALCONY TO REMAIN
AREA OF WOOK PLAN nts...
SCHEDULE
A — 96" X 96" (2 PANEL) SLIDING GLASS DOOR
B — 144" X 96" (3 PANEL) SLIDING GLASS DOOR
Paul Welch, P.E.
Reg. No 29945-
September 19, 2017