CONCFAL0 FASTENERS OR ATITACHMENTS
ARE THE RESPONSIBILITY OF THE
CONTRACTOR OF RECORD 1035"x47"
107"x IAO 2,035"xLI;7"
S&D 5510 [2) Si{ SE06
C1)PWS%G
S+15603 (z)Sk155M
34' x 47.0
ALL MANUFACTURES LqM SHOWING
U FACTORS AND SHGC COMPLIANCE
W1TN FSC ENERGY CODE MUST
REMAIN ON ALL DOORS AND WINDOWS
UNTIL INSPECTIONS ARE APPROVED
2 E?Ss" x4-7,,
SCANNED
BY
St. Lucie County
THESE PLANS AND ALL PROPOSED WORK
ARE SULIIECT TO ANY C MCI IONS
REQUIRED fiY FIELD INSK-CTORSTHAT '
MAYBE NECESSARY IN ORDER TO = _°
COt,IPLY WITN Ali, APPWCABLE CODES,
3arKer Tni'dence
= 4 s. ocean Dr.
un I-{ &0�0
JtnSen Beach, FL
:NA 5-7
yea �Nlnds
ST. LUCIE COUNTY
BUILDING DIVISION
In EvI[E%vCD
FOR Corjp)gl,&dCE
DATE _1 V.d
FLANS A!i;. P�I1IAI I
MUST Ca KEVW ON JOB OR
NO INSPECTION WILL D6 MADE
3570 S.E. Dixie Highway • Stuart, Florida 34997 • (772) 286-0459 - Fax:
,I SITE SPECIFIC F_JOR PLAN:
SCALE: N.T.S.
UNIT
#806
BUILDING FOOTPRINT
PLAN VIEW
BALCONY
7 N
170.0'
0
UNIT I UNIT #806NEXT UNIT
DOOR N80 FT ABOVE GRADE NEXT
DOOR
O
a
FLOOR PLAN AND UNIT LAYOUT
DESIGN NOTES:
FLORIDA BUILDING CODE F.r. .'. EDITION (2014) ASCE 7-10
Vult=170 MPH / Vasd=131.7 MPH (3 SECOND GUST), EXPOSURE'D', ENCLOSED STRUC=UFZE�,
RISK CATEGORY=II, Kd=0.85, Kzt=1.0, Kz=TABLE 30.3-1, GCpi=+/-0.18 �%% M,
qh = 0.00256*Kz*Kzt*Kd*V*V �� .• ENS
P = qh ((GCp)-(GCpi)) Q .• ��G
MRH=140', ZONE(S) AS NOTED, ROOF TYPE'MONOSLOPE', ROOF SLOPE 0.0, �:
PRESSURES: NOTED BELOW O: EBB
INSTALL ALL SYSTEMS PER VALID FLORIDA PRODUCT APPROVALS = C.� � NO P
GENERAL NOTES: = fc
1. THIS ENGINEERED PLAN IS INTENDED TO PROVIDE SITE -SPECIFIC DESIGN PRESSURES FOR THj=ERENCEtL��Tp1
STRUCTURE FOR THE PURPOSE OF THE INSTALLATION OF GLAZED/NON-GLAZED PRODUCTS AS 0 SED ANpt
PROVIDED BY OTHERS. NO CERTIFICATION, EITHER EXPRESSED OR IMPLIED, IS OFFERED AS TO 1IIL�p
OR APPLICABILITY OF ANYIPROPOSED SYSTEM OR COMPONENT USED ALONG WITH THESE PRESS
PRODUCT AND APPROVAL INFORMATION IS SPECIFICALLY REFERENCED AND ADDRESSED HEREIN. OP
2. NO CERTIFICATION OR REVIEW IS OFFERED THAT THE PROPOSED UNITS MEET ANY EGRESS REQUIREME084I)I( I
EGRESS ISSUES ARE TO BE ADDRESSED BY THE PERMITTING CONTRACTOR AND THE LOCAL BUILDING OFFICIAL.
3. THE HOST STRUCTURE IS ASSUMED TO BE ADEQUATE TO WITHSTAND THE LOADS IMPOSED BY THIS DESIGN AS
WORK REPLACES THE EXISTING FRAMING. IF ANY DEFICIENCIES ARE FOUND IN THE EXISTING HOST STRUCTURE,
THIS ENGINEER SHALL BE NOTIFIED BEFORE CONTINUING CONSTRUCTION AND RESERVES THE RIGHT TO
RE -INSPECT AND RE-EVALUATE DESIGN. NO WARRANTY, EITHER EXPRESSED OR IMPLIED, IS CONTAINED HEREIN.
SINCE IT IS NOT PRUDENT TO PERFORM DESTRUCTIVE TESTING AT THIS TIME, THE CONTRACTOR SHALL VERIFY
DURING CONSTRUCTION THAT THE SUBSTRATE IS OF THE TYPE AND CONSTRUCTION THAT IS IN CONFORMANCE
WITH THE INTENT OF THE PRODUCT APPROVAL BEING UTILIZED WHICH MUST BE SOUND FOR INSTALLATION OF
THIS SYSTEM AND SHALL NOTIFY THIS ENGINEER IF ANY DEFICIENCIES OR ABNORMALITIES ARE OBSERVED. USE
OF THIS DOCUMENT CONSTITUTES ACCEPTANCE OF THESE TERMS.
4. SYSTEMS SHALL BE AS NOTED HEREIN. ALL REFERENCES TO EXTRUSIONS & INSTALLATION SHALL CONFORM TO
THAT OF MANUFACTURER'S SPECIFICATIONS AS SUMMARIZED HEREIN.
S. ANY JUNCTURE OF EXTERIOR PLASTER AND FENESTRATION PRODUCTS SHALL BE SEALED WITH A SEALANT
COMPLYING WITH AAMA 800 AND ASTM C 920 CLASS 25 GRADE NS OR GREATER FOR PROPER JOINT EXPANSION
AND CONTRACTION, AND ASTM C1281 OR AAMA 812 FOR THE TYPE OF SEALANT TO BE SELECTED WHICH IS
OUTSIDE THE SCOPE OF THIS CERTIFICATION.
6. THE CONTRACTOR IS RESPONSIBLE TO INSULATE ALL MEMBERS FROM DISSIMILAR MATERIALS TO PREVENT
ELECTROLYSIS.
7. ALL CONCRETE SHALL BE UNCRACKED ONLY WITH A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI U.N.O. AND
SHALL BE MINIMUM 1.SX THICKER THAN ANY MEMBER EMBEDMENT. ALL EPDXY AND GROUT SHALL MEET OR
EXCEED COMPRESSIVE STRENGTH OF THE CONCRETE AND SHALL BE IRON -FREE, NON -SHRINK AND
NON -REACTIVE.
8. FOR ALUMINUM ATTACHMENTS ALL ANCHORS SHALL BE SPACED WITH 2xDIAMETER END DISTANCE AND
2.5xDIAMETER MIN SPACING TO ADJACENT ANCHORS, UNLESS NOTED OTHERWISE.
9. ALL FASTENERS TO BE #12 X 3/4" OR GREATER 2024-T4, 18-8 SERIES 300 NON-MAGNETIC STAINLESS STEEL, OR
CADMIUM PLATED OR OTHERWISE CORROSION RESISTANT MATERIAL AND SHALL COMPLY WITH J.3.1,
SPECIFICATIONS FOR ALUM. STRUCTURES -SECTION 1, THE ALUMINUM ASSOCIATION,INC., & APPLICABLE
FEDERAL,STATE, AND LOCAL CODES.
10. DIMENSIONS ARE SHOWN TO ILLUSTRATE DESIGN FORCES AND OTHER DESIGN CRITERIA. THEY MAY VARY
SLIGHTLY, TO THE EXTENT THAT THE OPENING AREA IS NOT SMALLER THAN 5% OF THE ENGINEERED DESIGN.
CONTRACTOR IS TO VERIFY ALL FIELD DIMENSIONS PRIOR TO INSTALLATION.
11. ENGINEER SEAL AFFIXED HERETO VALIDATES STRUCTURAL DESIGN AS SHOWN ONLY. USE OF THIS
SPECIFICATION BY CONTRACTOR, at. al. INDEMNIFIES & SAVES HARMLESS THIS ENGINEER FOR ALL COST &
DAMAGES INCLUDING LEGAL FEES & APPELLATE FEES RESULTING FROM MATERIAL FABRICATION, SYSTEM
ERECTION, & CONSTRUCTION PRACTICES BEYOND THAT WHICH IS CALLED FOR BY LOCAL, STATE, & FEDERAL
CODES & FROM DEVIATIONS OF THIS PLAN.
12. ENGINEERING EXPRESS HAS NOT VISITED THIS JOBSITE. INFORMATION CONTAINED HEREIN IS BASED ON
CONTRACTOR SUPPLIED DATA AND MEASUREMENTS. ENGINEERING EXPRESS SHALL NOT BE HELD RESPONSIBLE
OR LIABLE IN ANY WAY FOR ERRONEOUS OR INACCURATE DATA OR MEASUREMENTS. WORK SHALL BE FIELD
VERIFIED PRIOR TO CONSTRUCTION. ENGINEERING EXPRESS SHALL BE NOTIFIED AND GIVEN AN OPPORTUNITY
TO REEVALUATE OUR WORK UPON DISCOVERY OF ANY INACCURATE INFORMATION PRIOR TO MODIFICATION OF
EXISTING FIELD CONDITIONS AND FABRICATION AND INSTALLATION OF MATERIALS.
13. EXCEPT AS EXPRESSLY PROVIDED HEREIN, NO ADDITIONAL CERTIFICATIONS OR AFFIRMATIONS ARE INTENDED.
* ALTERATIONS, ADDITIONS, OR OTHER MARKINGS TO THIS DOCUMENT ARE NOT PERMITTED AND INVALIDATE OUR
CERTIFICATION *
DESIGN INFORMATION:
MARK
QTY
W x H (In.)
ZONE
DESIGN
PRESSURE
PRODUCT
APPROVAL#
PRODUCT MODEL
MULLION
APPROVAL#
MULLION SIZE
(in.)
1
1
107.00 x 80.00
4
+51.85 / -58.21
15-1210.01
SERIES 5570/2770 VINYL SGD
N/A
N/A
2
1
35.00 x 47.00
4
+57.13 / -61.91
16-0714.19
SERIES PW-5540 PVC FIXED WINDOW
16-0218.03
1 x 4 x 0.125
3
(2)
35.00 x 47.00
4
+57.13 / -61.91
16-0714.03
SERIES 5500 PVC SINGLE HUNG WINDOW
16-0218.03
1 X 4 x O.IZS
4
(1)
34.00 x 47.00
4
+57.13 / -61.91
16-0714.03
SERIES 5500 PVC SINGLE HUNG WINDOW
N/A
N/A
5
(2)
35.00 x 47.00
4
+57.13 / -61.91
16-0714.03
SERIES 5500 PVC SINGLE HUNG WINDOW
16-0218.03
1 x 4 x 0.125
DRAWING NOTES:
ALTER)N LEVEL: TMIS SHEET I!
IMNEER HALL 8E CONTACTED T
PR DESIGNATIONS: ANY DOOR
ED.
SRL HEIGHTS: WINDOWS MUSTK
WITH LEVEL OF ALTERAIION I ONLY. IF LEVEL OF ALIEFAMON IS DIFFERENT, THIS
STING BALCONIES WILE EXISTING 4r HIGH APPROVED GUARDS WHICH SHALL NOT
MR UB SHUTTER PRODUM HAVE BEEN GLLULATFD USING WIDTH - HEIGHT 3 (EFFECTIVE AREA = H-H/3)
RANK L BENNARDO, P.E.
E* PE000549 A ,
4z o
rw DDII�S�. m
(n w � w
fT OWU-zx
f>Q TgL9.
U0L QLm=ZO
Z Lxu
w 0"-1 �LU ZV
3�EWZ
IDu4=W
p W
H
17-5087