Loading...
HomeMy WebLinkAboutPLANS1-7 SITE SPECIFIC FL�,bR PLAN: SCALE: N.T.S. UNIT #1402 BUILDING FOOTPRINT PLAN VIEW UNIT N EXT EO 7 85.0. BALCONY O UNIT #1402 N 140 FT ABOVE DESIGN NOTES: J \\ttT)I FLORIDA BUILDING CODE FIFTH EDITION (2014) ASCE 7-10 ��� �Ot4 M. Vult=160 MPH / Vasd=123.9 MPH (3 SECOND GUST), EXPOSURE'D', ENCLOSED STRU,L�Tf,.•' ' RISK CATEGORY=II, Kd=0.85, Kzt=1.0, KZ=TABLE 30.3-1, GCpi=+/-0.18 C� .• / qh = 0.00256*Kz*Kzt*Kd*V*V No P = qh ((GCp)-(GCpi)) = Jf i MRH=160', ZONE(S) AS NOTED, ROOF TYPE 'MONOSLOPE' i ROOF SLOPE 0.00 _ I 0 PRESSURES: NOTED BELOW 3 INSTALL ALL SYSTEMS PER VALID FLORIDA PRODUCT APPROVALS _;0 ,wi GENERAL NOTES: "N 'TAT( F`OR 1. THIS ENGINEERED PLAN IS INTENDED TO PROVIDE SITE -SPECIFIC DESIGN PRESSURES FOR THE REP�j� STRUCTURE FOR THE PURPOSE OF THE INSTALLATION OF GLAZED/NON-GLAZED PRODUCTS AS PROPOSED N �- PROVIDED BY OTHERS. NO CERTIFICATION, EITHER EXPRESSED ORiIMPLIED, IS OFFERED AS TO THE VALID _ OR APPLICABILITY OF ANY PROPOSED SYSTEM OR COMPONENT USED ALONG WITH THESE PRESSURES UNLES U PRODUCT AND APPROVAL INFORMATION IS SPECIFICALLY REFERENCED AND ADDRESSED HEREIN. 2: NO CERTIFICATION OR REVIEW IS OFFERED THAT THE PROPOSED UNITS MEET ANY EGRESS -REQUIREMENTS. ALL . EGRESS ISSUES ARE TO BE ADDRESSED BY THE PERMITTING CONTRACTOR AND THE LOCAL BUILDING OFFICIAL. 3. THE HOST STRUCTURE IS ASSUMED TO BE ADEQUATE TO WITHSTAND THE LOADS IMPOSED BY THIS DESIGN AS WORK REPLACES THE EXISTING FRAMING. IF ANY DEFICIENCIES ARE FOUND IN THE EXISTING HOST STRUCTURE, THIS ENGINEER SHALL BE NOTIFIED BEFORE CONTINUING CONSTRUCTION AND RESERVES THE RIGHT TO RE -INSPECT AND RE-EVALUATE DESIGN. NO WARRANTY, EITHER EXPRESSED OR IMPLIED, IS CONTAINED HEREIN. SINCE IT IS NOT PRUDENT TO PERFORM DESTRUCTIVE TESTING AT THIS TIME, THE CONTRACTOR SHALL VERIFY DURING CONSTRUCTION THAT THE SUBSTRATE IS OF THE TYPE AND CONSTRUCTION THAT IS IN CONFORMANCE WITH THE INTENT OF THE PRODUCT APPROVAL BEING UTILIZED WHICH MUST BE SOUND FOR INSTALLATION OF THIS SYSTEM AND SHALL NOTIFY THIS ENGINEER IF ANY DEFICIENCIES OR ABNORMALITIES ARE OBSERVED. USE OF THIS DOCUMENT CONSTITUTES ACCEPTANCE OF THESE TERMS. 4. SYSTEMS SHALL BE AS NOTED HEREIN. ALL REFERENCES TO EXTRUSIONS & INSTALLATION SHALL CONFORM TO THAT OF MANUFACTURER'S SPECIFICATIONS AS SUMMARIZED HEREIN. S. ANY JUNCTURE OF EXTERIOR PLASTER AND FENESTRATION PRODUCTS SHALL BE SEALED WITH A SEALANT COMPLYING WITH AAMA 800 AND ASTM C 920 CLASS 25 GRADE NS OR GREATER FOR PROPER JOINT EXPANSION AND CONTRACTION, AND ASTM C1281 OR AAMA 812 FOR THE TYPE OF SEALANT TO BE SELECTED WHICH IS OUTSIDE THE SCOPE OF THIS CERTIFICATION. 6. THE CONTRACTOR IS RESPONSIBLE TO INSULATE ALL MEMBERS FROM DISSIMILAR MATERIALS TO PREVENT ELECTROLYSIS, 7. ALL CONCRETE SHALL BE UNCRACKED ONLY WITH A MINIMUM COMPRESSIVE STRENGTH OF 3000 PSI U.N.O. AND SHALL BE MINIMUM 1.SX THICKER THAN ANY MEMBER EMBEDMENT. ALL EPDXY AND GROUT SHALL MEET OR EXCEED COMPRESSIVE STRENGTH OF THE CONCRETE AND SHALL BE IRON -FREE, NON -SHRINK AND NON -REACTIVE. B. FOR ALUMINUM ATTACHMENTS ALL ANCHORS SHALL BE SPACED WITH 2xDIAMETER END DISTANCE AND 2.SxDIAMETER MIN SPACING TO ADJACENT ANCHORS, UNLESS NOTED OTHERWISE. 9. ALL FASTENERS TO BE #12 X 3/4" OR GREATER 2024-T4, 18-8 SERIES 300 NON-MAGNETIC STAINLESS STEEL, OR CADMIUM PLATED OR OTHERWISE CORROSION RESISTANT MATERIAL AND SHALL COMPLY WITH 1.3.1, SPECIFICATIONS FOR ALUM. STRUCTURES -SECTION 1, THE ALUMINUM ASSOCIATION,INC., & APPLICABLE FEDERAL,STATE, AND LOCAL CODES. 10. DIMENSIONS ARE SHOWN TO ILLUSTRATE DESIGN FORCES AND OTHER DESIGN CRITERIA. THEY MAY VARY SLIGHTLY, TO THE EXTENT THAT THE OPENING AREA IS NOT SMALLER THAN 5% OF THE ENGINEERED DESIGN. CONTRACTOR IS TO VERIFY ALL FIELD DIMENSIONS PRIOR TO INSTALLATION. 11. ENGINEER SEAL AFFIXED HERETO VALIDATES STRUCTURAL DESIGN AS SHOWN ONLY. USE OF THIS SPECIFICATION BY CONTRACTOR, at. al. INDEMNIFIES & SAVES HARMLESS THIS ENGINEER FOR ALL COST & DAMAGES INCLUDING LEGAL FEES & APPELLATE FEES RESULTING FROM MATERIAL FABRICATION, SYSTEM ERECTION, & CONSTRUCTION PRACTICES BEYOND THAT WHICH IS CALLED FOR BY LOCAL, STATE, & FEDERAL CODES & FROM DEVIATIONS OF THIS PLAN. UNIT 12. ENGINEERING EXPRESS HAS NOT VISITED THIS JOBSITE. INFORMATION CONTAINED HEREIN IS BASED ON CONTRACTOR SUPPLIED DATA AND MEASUREMENTS. ENGINEERING EXPRESS SHALL NOT BE HELD RESPONSIBLE NEXT OR LIABLE IN ANY WAY FOR ERRONEOUS OR INACCURATE DATA OR MEASUREMENTS. WORK SHALL BE FIELD VERIFIED PRIOR TO CONSTRUCTION. ENGINEERING EXPRESS SHALL BE NOTIFIED AND GIVEN AN OPPORTUNITY TO REEVALUATE OUR WORK UPON DISCOVERY OF ANY INACCURATE INFORMATION PRIOR TO MODIFICATION OF EXISTING FIELD CONDITIONS AND FABRICATION AND INSTALLATION OF MATERIALS. OR 13. EXCEPT AS EXPRESSLY PROVIDED HEREIN, NO ADDITIONAL CERTIFICATIONS OR AFFIRMATIONS ARE INTENDED. *.ALTERATIONS, ADDITIONS, OR OTHER MARKINGS TO THIS DOCUMENT ARE NOT PERMITTED AND INVALIDATE OUR - CERTIFICATION * ' DESIGN INFORMATION: SCANNED BY i xie County Ajuno0 Gionl Ile ®3NNVOc MARK QTY W x H (' in.) ZONE DESIGN PRESSURE (psf) PRODUCT APPROVAL # PRODUCT MODEL SERIES 8100 1 (1) 94.00 x 102.00 4 +49.36 / -52.41 15-0723.12 ALUMINUM SLIDING GLASS DOOR SERIES 8100 2 (1) 142.00 x 102.00 4 +47.41 / -51.10 15-0723.12 ALUMINUM SLIDING GLASS EIVED OCT 2 3 2017 17 I 00 -I D 2 W�W"Imwo I ZQ=a.x- D. 0 QZ av, w WL7L'- yZ0 II11,,m WW OJ5WwV U~ W �OZ LL LAW a.. Z O LU 6 U3 R :i En En Q > Z K 0 N ¢ o U) W o O W xLL.. F e .QH U UU a ry Z Z W 2. LU a n E n O En w g LU _ 00 .gip 1 COPYRIGHT ENGINEERING E[PRIMS I DRAWING NOTES: PERMITTING 17-5177 St. Lucie County, FL • ALTERATION LEVEL: THIS SHEET IS INTENDED FOR USE IN PROIECIS WITH LEVEL OF ALTERATION 1 ONLY. IF LEVEL OF ALTERATION IS DIFFERENT, THIS SCALE; N.T.S. NN INEEEERRS9VE9E CONTACTED FOR ADDITIONAL CERTIFICATION. ._..__ OF � • DOOR DESIGNATIONS: ANY DOOR PRODUCT SHALL EMT ONLY TO ENISTING BALCONIES WITH E DUSTING 42' HIGH APPROVED GUARDS WHICH SHALL NOT ? �•... ..._...,� ..._........... .... .... �........ ...._......__.._.._._.....__._._... ....-_..._.__... - - ING TO ASS NIF FLOOR PLAN AND UNIT LAYOUT THE BLOCKS WHICH BE REMOVABLE). CAN WINDOWS WITH AT ANY POINT CONFIGURATION 3 HAL].ALSOPoR RESCUEWINDOWSDOWS WHICH IN IHE ICAMON CONFORMING 10 FBEMERGENCY THE GUARD R MUST BE REMOVABLE). WINDOWS WITH THIS CONFIGURATION SHALL ALSO HAVE SEPARATE CERTInCATION CONFORMING TO FBC FOR SAFEGUARDS WHICH NOT INCLUDED INTHLS DOCUMENT. • WNFN APPLICABLE, WIND PRESSURE INFORIMlI0N FO0. LISTED GNIfTTE0. PRODUCTS HAVE BEEN CALCULATED USING WIDTH eMEIGHT/3(EFFECDVFAREA =M'H/3) - / @ a, • � k� S � * /t � (•!�}� \ $\w{/ \■ �� [