HomeMy WebLinkAboutMISC EMAILPAUL WELCH INC. Mechanical * Electrical * Civil Engineering 1984 S.W. Biltmore St. Suite#114 Port Saint Lucie, FL 34984 SCANNED Phone (772) 785 - 9888 BY Email pwelchinc@aol.com St. Lucie Countv, December 4, 2017 Re: Roof Replacement 10152 S. Ocean Dr. Bldg B Jensen Beach, FL To Whom It May Concern: THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CMCTIONS REWRED DY FIELD INSPEOTOR TKAT MAYBE NECESSARY IN ORDER TO COMPLY WITH ALLAPUAN COOSA, Our office has calculated the required design pressure in accordance with ASCE 7-10 for the roof at the above referenced address. Wind speed: Exposure: D I,. 165mph, Visa: 124 mph CONCFUO FASTENERS OR ATTACHME!.-m Enclosure Type: Enclosed ARE THE RESPONSIBILITY OF THE Roof Pitch: 0.25:12 AR OF RECORD Mean Height: 65 feet Required Design Pressure (Zone 3): -139.2 PSF Roof to be installed shall be, equal to, or exceed the required design pressures as listed above. All installations shall be in accordance with FBC 2014 and manufacturer's installation instructions. Proposed Roofing: Certainteed Modified Bitumen FL#2533.1 System C-106 Proposed Roofing Design Pressure: -420 PSF Thank you for your attention to this matter. Submitted by: PAUL WELCH INC Paul Welch, P.E. / Reg. No 29945 D - OSS 5� ST. LUCIE COUNTY BUILDING DIVISION REVIEWED FOR COP41PLIANCE REVIEWED BY DATE 12 — 7 PLANS AND PERMIT MUST BE KEPT ON JOB OR NO INSPECTION WILL BE MADE �� i