Loading...
HomeMy WebLinkAboutPRODUCT APPROVALdb' 1, -, P BCIS Home Log In User Registration Hot Topics Submit Surcharge - Stan & Facts Publications RIC Stall BCIS Site Map Links Search ',I �5:. Product Approval USER: public User RECEIVED OCT 23 my Product Approval Menu > Product or Application Search > Application Malt Search Criteria Code Version Application Type Category Application Status Quality Assurance Entity Product Model, Number or Name Approved for use in HVHZ Impact Resistant Other Search Results - Applications Refine Search 2014 FL# 2533.1 ALL Product Manufacturer ALL ALL Subcategory ALL ALL Compliance Method ALL ALL Quality Assurance Entity Contract Expired ALL ALL Product Description ALL ALL Approved for use outside HVHZ ALL ALL Design Pressure ALL ALL FL# T voe Manufacturer-- ----- — — Validated By —Status — FL2533-RIS Revision CertainTeed Corporation -Roofing FL#: FL2533.1 John W. Knezevich, PE (954) 772-6224 Approved History Model: Flintlastic Modified Bitumen Roof Systems Description: Modified Bitumen Roof Systems Category: Roofing Subcategory: Modified Bitumen Roof System 'Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission If necessary. Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-437-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florda.:: privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. It you do not want your e-mail address released In response to a public -records request, do not send electronic mall to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 4S5, F.S. must provide the Department with an email address if they have one. The smalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please click hem. Product Approval Accepts: M 10�1 © ct'- M SCANNED BY St. Lucie County •' e securltymETR(OS- }4 -- - — - y } r TTRINITY1 ERD APPENDIX 1: ATTACHMENT REQUI0.EMENTS FOR WINDUPLIFT RESISTANCE "'t "" Table Deck Application Type Description Page 1A Wood New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover --1 5-6 18 Wood New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover —' 7 1C Wood New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 8-9 SD Wood New, Reroof (Tear -Off) or Recover D Insulated, Mech. Attached Base Sheet, Bonded Roof Cover cl 10-12 1E-1 Wood New, Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover - 13-15 1E-2 Wood New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 16-17 1F Wood New or Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 1 17 A Steel or Structural Concrete New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Tap Insulation, Bonded Roof Cover 18-20 ' 1B Steel or Structural Concrete New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover ZEM� ' 21-25 2C Steel or Structural Concrete New, Reroof (Tear -Off) or Recover D Insulated, Mech. Attached Base Sheet, Bonded Roof Cover Etc"=J 26-28 3A Concrete New or Reroof (Tear -Oft) A-1 Bonded Insulation, Bonded Roof Cover 29-36 3B Concrete New or Reroof (Tear -Off) A-3 Bonded Temp Roof/Vapor Barrier, Bonded Insulation, Bonded Roof Cover 3C Concrete New or Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 37 ; 4A LWIC New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 38-39 48 LWIC New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 40 4C LWIC New, Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 41-44 SA CWF New or Reroof (Tear -Oft) A-1 Bonded Insulation, Bonded Roof Cover 45 5B CWF New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 46 5C CWF New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 46 5D CWF New, Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 47 6A Gypsum Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 48-49 6B Gypsum Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 50 6C Gypsum Reroof (Tear -Oft) C Mech. Attached Insulation, Bonded Roof Cover 51 6D Gypsum Reroof (Tear -Oft) E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 51 - `A Various Recover A-1 Bonded Insulation, Bonded Roof Cover 52-57 3 Various Recover F Non -Insulated, Bonded Roof Cover 57 The following notes apply to the systems outlined herein: 1. The roof system evaluation herein pertains to above -deck roof components. Roof decks shall be in roof deck shall be documented through proper codified and/or FBC Approval documentation. accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the 2. Unless otherwise noted, fasteners and stress plates for insulation attachment shall be as follows. Fasteners shall be of sufficient length for the following engagements: ➢ Wood Deck: OMG #14 Roofgrip with Flat Bottom Plate (Accutrac), OMG HD with OMG 3 in. Galvalume Steel Plate, Dekfast #14 with Hex Plate or 3" Round Insulation Plate, Trufast HD with Trufast 3" Metal Insulation Plates or FlintFast #14 Fastener with FlintFast 3" Insulation Plates. Minimum 0.75-inch plywood penetration or minimum 1-inch wood plank embedment. ➢ Steel Deck: OMG #12 or #14 Roofgrip with Recessed or Flat Bottom Plate (Accutrac), OMG #12 Standard or HD with OMG 3 in. Galvalume Steel Plate, Dekfast #12 or #14 with Hex Plate or 3" Round Insulation Plate, Trufast DP or HD with Trufast 3" Metal Insulation Plates or FlintFast #12 or #14 Fastener with FlintFast 3" Insulation Plates. Minimum 0.75-inch steel penetration and engage the top flute of the steel deck. D Structural Concrete: OMG #14 Roofgrip with Recessed or Flat Bottom Plate (Accutrac), OMG HD or CD-10 with OMG 3 in. Galvalume Steel Plate, Dekfast 414 or DekSpike with Hex Plate or 3" Round Insulation Plate, Trufast HD or CF with Trufast 3" Metal Insulation Plates or FlintFast #14 Fastener with FlintFast 3" Insulation Plates. Minimum 1-inch embedment. Fasteners installed with a pilot hole in accordance with the fastener manufacturer's published installation instructions. Exterior Research and Design, U.C. d/b/a Trinity I ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 FBC NON-HVHZ EVALUATION CertainTeed Corporation; (610) 651-5847 Evaluation ReportI3520.03.04-1119 for FL2533-R18 Revision 19:06/06/2017 Appendix 1, Page 1 of 57 "�'/ TRINIT�Y i ERD 3. Unless otherwise noted, insulation may be any one layer or combination of polyisocyanurate, polystyrene, wood fiberboard, perlite, GlasRoc Roof Board or gypsum -based roof board that meets the @ujrements of F.A.C. Rule 61G2D-3 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC 2603.4.1 or 2603.8, when installed with the roof cover. f 4. Minimum 200 psi, minimum 2-inch lightweight insulating concrete may be substituted for rigid insulation board for System Type D (mechanically attached base sheet, bonded roof cover), where � .babe sheet fasteners are installed through the LWIC to engage the structural steel or structural concrete deck. The structural deck shall be of equal or greater configuration to the steel and structural concrete dfoaftings. S. Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturers publish&MM ctions. ➢ Hot asphalt (HA): Full coverage at 25-30lbs/square D Ashland Pliodeck(A-PD): Continuous 0.75 inch wide ribbons, 12-inch o.c. Ribbons of subsequent layers shall be perpendicular to those in the layer below. .J D Dow Insta-Stik (D-IS): Continuous 0.75 to 1 inch wide ribbons,12-inch o.c. ➢ Millennium One Step Foamable Adhesive (M-OSFA): Continuous 0.25 to 0.5-inch wide ribbons, 12-inch o.c. ➢ Millennium PG-1 Pump Grade Adhesive (M-PG1): Continuous 0.5 to 0.75-inch wide ribbons, 12-inch o.c. .. l D OMG OlyBond 500 or OlyBond Green (OB500): Continuous 0.75-inch wide ribbons,12-inch o.c. (PaceCart or SpotShot) e ➢ ICP Adhesives CR-20: Continuous 2.5 to 3-inch wide ribbons,12-inch o.c. ` ➢ Note: When multiple layers(s) of insulation and/or coverboard are installed in ribbon -applied adhesive, adhesive ribbons shall be staggered from layer -to -layer a distance of one-half the ribbazEM32cing. ➢ Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. I 6. Unless otherwise noted, all insulations are flat -stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations may be substituted with the following Maximum Design Pressure (MDP) limitations. In no case shall these values be used to 'increase' the MOP listings in the tables; rather if MOP listing below meets or exceeds that listed for a particular system in the tables, then the thinner board listed below may be used as a drop -in for the equivalent thicker material listed in the table: ➢ Ashland Pliodeck (A-PD) @ 12-inch o.c. MOP -105.0 psf (Min. 1.0-inch) ➢ Ashland Pliodeck (A-PD) @ 6-inch o.c. MDP -277.5 psf (Min. 1.0-inch) ➢ Dow Insta-Stik (D-IS): MDP -120.0 psf (Min. 1.0-inch) ➢ Millennium One Step Foamable Adhesive (M-OSFA): MDP -157.5 psf (Min. 1.0-inch) D Millennium PG-1 Pump Grade Adhesive (M-PG1): MOP -157.5 psf (Min. 1.0-inch) - ➢ OMG OlyBond 500 (OB500): MDP -45.0 psf (Min. 0.5-inch Multi -Max FA3) D OMG OlyBond 500(OB500): MDP -187.5 psf (Min. 0.5-inch ISO 95+GL) D ON G OlyBond 500 (O13500): MOP -315.0 psf (Min. 0.5-inch ENRGY 3) ➢ OMG OlyBond 500 (OB500): MDP -487.5 psf (Min. 0.5-inch ACFoam 11) D ICP Adhesives CR-20: MDP -117.5 psf (Min. 1.0-inch) 7. Bonded polyisocyanurate insulation boards shall be maximum 4 x 4 ft. For mechanically attached components or partially bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WDl, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk• carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 9. For assemblies with all components fully bonded in place, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16, and no rational analysis is permitted. 10. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 11. For existing substrates in a bonded recover or re -roof installation, the existing roof surface or existing roof deck shall be examined for compatibility and bond performance with the selected adhesive, and the existing roof system (for recover) shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 12. For Concrete Deck or Recover Applications using System Type D, the insulation is optional. Exterior Research and Design, U.C. d/b/a Trinity I ERD Evaluation Report 3520.03.04-1119 for FL2533-R18 -Certificate of Authorization #9503 FBC NON-HVHZ EVALUATION Revision 19: 06/06/2017 Prepared by: Robert Niernmen, PE-59166 CertainTeed Corporation; (610) 651-5847 Appendix 1, Page 2 of 57 �INITi i ERD 13. Lightweight Insulating Concrete (LWC) shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWC is referenced, refer to current LWC Product Approval for specific deck construction and limitations. For systems where specific LWC is not referenced, the minimum design mix shall be 300 psi. In all cases, the mini oat thickness is 2-inches. For LWC over structural concrete, reference is made to FBC Section 1917.4.1, Point 1 r 14. Unless otherwise noted, refer to the following references for bonded base, ply or cap sheet applications. {ERTAINTEED FUNTASTIcm,MODIFIED BITUMEN COMPONENTS& APPLICATION METHODS Reference Layer Material Applicati , BP -AA Base Glasbase; All Weather/Empire Base; Flexiglas Base; Flintlastic Base 20 Hot j asph at 2b Ibs/square (Ease and plrsheets, AsplaE-Applied) Ply One or more Flintglas Ply 4; Flintglas Premium Ply 6 BP-AA2 Base Yosemite Venting Base Hot asphalt in 24-inch diameter spots in 30- lea®,Sppt-AephaftApplled) inch grid tan BP-AA3 Base Yosemite Venting Base Hot asph 'in h diameter spots in grid (Base, Spot -Asphalt -Applied) pattern noted her In. BP-AA4 Base Yosemite Venting Base Hot asph9_ ir)ch wide ribbons spaced (Base, strip -Asphalt -Applied) as noted a gn. BP-CA2 Base/Ply Glasbase; All Weather/Empire Base; Flexiglas Base; Flintlastic Base 20 Henry #QW&hesive at 1.5 gal/square Base/Ply Glasbase; All Weather/Empire Base; Flexiglas Base; Flintlastic Base 20 Millennium Hurricane Force Membrane BP CA3 Adhesive, beads spaced 6-inch o.c. Base Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base Ply One m more Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base SBS-AA Hot asphalt at 20-401hs/square Cap Flintlastic Cap 30; Flintlastic Cap 30 CooiStar; Flintlastic FR Cap 30; Flintlastic FR Cap 30 CoolStar; Flintlastic FR Dual (SBS,AspMRAPPlled) Cap; Flintlastic FR-P; Flintlastic FR-P CoolStar; Flintlastic Premium FR-P; Flintlastic Premium FR-P CoolStar; Flintlastic GMS; Flintlastic GMS CoolStar; Flintlastic Premium GMS; Flintlastic Premium GMS CoolStar Base Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base Note: Base ply cures overnight prior to application of the ply or cap ply. FlintBond Brush or Karnak No. 81 Cold SBS-CAl Ply Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base Process Modified Bitumen Adhesive Brush Cap Flintlastic FR Cap 30; Flintlastic FR Cap 30 CoolStar; Flintlastic FR Dual Cap; Flintlastic FR-P; Flintlastic FR-P CoolStar; (SBS,Cold-Applied) Grade at 1 gal/square Flintlastic Premium FR-P; Flintlastic Premium FR-P CoolStar; Flintlastic GMS; Flintlastic GMS CoolStar; Flintlastic Premium GMS; Flintlastic Premium GMS CoolStar Base Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base Ply Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base SBS-CA2 Henry #903 Adhesive at 1.5 gal/square. Cap Flintlastic Cap 30; Flintlastic Cap 30 CoolStar, Flintlastic FR Cap 30; Flintlastic FR Cap 30 CoolStar; Flintlastic FR Dual (SES, roW-Applied) Cap; Flintlastic FR-P; Flintlastic FR-P CoolStar; Flintlastic Premium FR-P; Flintlastic Premium FR-P CoolStar; Flintlastic GMS; Flintlastic GMS COOIStar; Flintlastic Premium GMS; Flintlastic Premium GMS CoolStar Base Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base Ply Flintlastic Base 20; Flintlastic Poly SMS Base; Flintlastic Ultra Poly SMS Base Millennium Hurricane Force Membrane SBS-CA3 Adhesive, beads spaced 6-inch o.c. Cap Flintlastic Cap 30; Flintlastic Cap 30 CoolStar; Flintlastic FR Cap 30; Flintlastic FR Cap 30 CoolStar; Flintlastic FR Dual (SBS,Wd-Applied) Cap; Flintlastic FR-P; Flintlastic FR-P CoolStar; Flintlastic Premium FR-P; Flintlastic Premium FR-P CoolStar; Flintlastic GMS; Flintlastic GMS CoolStar; Flintlastic Premium GMS; Flintlastic Premium GMS CoolStar Exterior Research and Design, U.C. d/b/a Trinity HERD Evaluation Report 3520.03.G4-R19 for FL2533-RlB Certificate of Authorization 0503 FBC NON-HVHZ EVALUATION Revision 19: 06/06/2017 Prepared by: Robert Niernmen, PE-59166 CertainTeed Corporation; (6101651-5847 Appendix 1, Page 3 of 57 qi�RINITYJERD FUNNAsnc-,MODmED BITUMEN COMPONENTS& APPUCATIONMEMODS(CODMNUED)" Reference layer Material Application f: Base Flintlastic Ultra Poly SMS Base; Flintlastic Base 20 T �: Ply One or more Flintlastic Ultra Poly SMS Base; Flintlastic Base 20 T SBS-TA Torch -Applied Cap Flintlastic FR Cap 30 T; Flintlastic FR Cap 30 TCoolStar; Flintlastic GTS; Flintlastic GTS CoolStar; Flintlastic GTS-FR; (SBS, .or Applied) it . Flintlastic GTS-FR CoolStar; FlintClad Base One or more Flintlastic APP Base T; Flintlastic STA; Flintlastic STA Plus APP-TA Torch -Applied Cap Flintlastic STA; Flintlastic STA Plus; Flintlastic GTA; Flintlastic GTA CoolStar; Flintlastic GTA-FR; Flintlastic GTA-FR (APPjarch-Applied) CoolStar LL i SBS-SA-H Base/Ply Black Diamond Base Sheet; Flintlastic Ultra Glass SA Self -Adhering (SBS, Self-Adhenn& Nybnd Sy tem) USES—_ Base Flintlastic SA PlyBase; Flintlastic SA Mid Ply mom' I Ply Flintlastic SA PlyBase; Flintlastic SA Mid Ply SBS-SA Self -Adhering I (595, Self-Atlhering) Cap Flintlastic SA Cap; Flintlastic SA Cap CoolStar; Flintlastic SA Cap FR; Flintlastic SA Cap FR CoolStar 15. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads. Exterior Research and Design, U.C. d/b/a Trinity ERD Evaluation Report 3520.03.04-R19 for FL2533-1118 Certificate of Authorization k9503 FBC NON-HVHZ EVALUATION Revision 19:06/06/2017 Prepared by: Robert Niernmen, PE-59166 CertainTeed Corporation; (62016S1-5847 Appendix 1, Page 4 of 57 System Deck No. (Note 1) SEIF•ADHE0.ING SYSTEMS C-98. Structural concrete" C-99. Structural concrete �HYBRIO SYSTEMS: "':'. ' Structural concrete - Structural concrete uctural concreteructural concreteuctural LW-A� concreteSTEMS.uctural concrete PrimerBase Roof Cover(Note 14) Ply ,fFlintPrime SA SBS-SA (Optional) SBS-SA FlintPrime (ASTM D41) SBS-SA (Optional) SBS-SA FlintPrime SA Flintlastic Ultra Glass SA (Optional)SBS-AA, SBS-TA, APP-TA FlintPrime (ASTM D41) Flintlastic Ultra Glass SA (Optional) SBS-AA FlintPrime (ASTM D41) Black Diamond Base Sheet (Optional) SBS-TA, APP-TA FlintPrime (ASTM D41) Flintlastic Ultra Glass SA (Optional) SBS-TA, APP-TA FlintPrime (ASTM D41) Black Diamond Base Sheet (Optional) BP -AA, SBS-AA FlintPrime(ASTM D41) BP -AA or SBS-AA (Optional) BP -AA, SBS-AA, SBS-TA or APP-TA ..d .4 M SBS-SASBS-SA SBS-AA, SBS-TA, APP-TA 7SBS-AASBS-TA, APPSBS-TA, APP-TA SBS-AA SBS-AA,SBS-TAorAPP-TA goo "A MDP (Psf) iC -555.0 -630.0 -52.5 -135.0 -322.5 -240.0 -240.0 4 - 20: uctural;concreteI E'Flin`tPr'im (ASTM D41)M fAPP-TA t( pt=W)AP_--�PJ6 APP_TA C-307. Structural concrete FlintPrime (ASTM D41) I SBS-TA (Optional) SBS-TA SBS-TA - COtn-APPLIED SYSTEMS. •'' "' T •' .. ' t c C-308. Structural concrete FlintPrime (ASTM D41) SBS-CA1 (Optional) SBS-CA1 SBS-CA3 -262.5 Exterior Research and Design, LLC d/b/a Trinity HERD 'Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 FBC NON-HVHZ EVALUATION CertainTeed Corporation; (610) 651-5847 Evaluation Report 3520.03.04-R39 for Ft2533-1138 Revision 19: 06/06/2017 Appendix 1, Page 37 of 57