HomeMy WebLinkAboutPRODUCT INFORMATIONMONO POLY
HELIENE
SCANNED
BY
St. Lucie Co
60m
60-CELL MONOCRYSTALLVNE MODULE
HELIENE;INC. IS A:PREMIER SOLAR'MODULE
MANUFACTURER,SERVICING THE GROWING'
SOLAR ENERGY MARKETS OF NORTH110ERICA.
COMBINING,PROVEN',EUROPEANTECHNOLOGY
WITH'NORTH,AMERICAN INGENUITY ALLOWS
HELIENE'TO MAKE A REAL COMMITMENT IN.
PROVIDING' SMARTER ENERGY CHOICES FOR
THE FUTURE.
HELIENE
www.heliene.com
GUARANTEED POSITIVE POWER SORTING: [-0 : +4.99 WPI
DESIGNED FOR 1500V DC APPLICATIONS
,.-,.I .
MANUFACTURED ACCORDING TO INTERNATIONAL
/ QUALITY SYSTEM STANDARDS:IS09001
H-BLACK INTEGRATION AVAILABLE (ALL -BLACK MODULE)
. E R F 0 I
10 YEAR WORKMANSHIP WARRANTY 25 YEAR LINEAR PERFORMANCE GUARANTEE
95A0% AODEp VALUEfRO —
MRfIIE
g NESlIHEgp{y pRAN�
es.aan
;v
s" ea.00x —
)tlAO%
Vear
60N
, 'a..
C E W,
°, .k
®. EN _ FW k
Cr
HELIENE
ELECTRICAL DATA(STC)
Peak Rated Power .Pm,, W) ; 305- 300 295. 290 _ 285'
Maximum Power Voltage V."IV)
33.44
33.14
32.84
32.537
32.236
Maxi mum Power Current I„pp:(A) 9.196 9.127 9.068,989 0:92
Open Circuit Voltage V. IV)
39.981
39.83
39.68
39.528
39.30
Short Circuit Current Ise (A) 9:673 9.59 9.51 9.424 9.34
Module Efficiency ` Eff (%)
18.9 18.6
18.3
18.0
11.7
Power Output Tolerance - 1-0,+4.991 Wp '
STC -Standard Test Conditions: Irradiation 1090 W/m2 - Air mass AM 1.5 -Cell temperature 25 °C
*Calculated using maximum power based on full positive output tolerance [-0 , +4.991 Wp
MECHANICAL DATA
- Dimensions(LzWa D)
1650 x992x 40 mm(65 x 39 x 1:6 inch)
Weight`
20 kg(43.9 lbs)
Output Cables
1.1an(43.3 inch) symmetrical cables with MC4 type connectors ,
Junction Box
IP-67 rated with bypass diodes
Frame
Double webbed 15 micron: anodized aluminum alloyy
Front Glass
Low -iron content, high -transmission PV solar glass
Solar Cells
60 Monocrystalline cells (156x 156 mm)
Calculated using 3.2mm PV glass, if 4mm profile is requested weight lead will vary
CERTIFICATIONS
DL Listed 'ULC/ORD-CI7D31., UL17113, UL1703 Fire '-classification Typel
IEC Listed IEC 81215. IEC 61730
All Heliene modules are certified under the California Energy Commision (CEC) Listing Report
TEMPERATURE RATINGS
Nominal Operating Cell
Temperature(NOCT)'
+45°C:(x2°Cj
-
Temperature Coefficient of Pm„
-0.39%/°C
Temperature. Coefficient of Vs
-0.31%rc
Temperature Coefficient of I
0.045%/°C
MAXIMUM RATINGS
Operational Temperature 40°C - Tic!
Max System Voltage 1500V (UL/IEC)
Max Series fuse Rating 15.A
WARRANTY
I GYear :Manufacturer's Workmanship Warranty,
25 Year Linear Power Guarantee
(Refer to product warranty page for details)
PACKAGING CONFIGURATION
Modules per boa: 25 pieces
Modules per 53'trailer: 750 pieces
CAUTION: READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT.
C 2016 Heliene Inc. All rights reserved. Specifications included in this datasheet are subject to
change without notice.
Enphase® Microinverters
EnphasUM250
The Enphase® M250 Microinverter delivers increased energy harvest and reduces design and
installation complexity with its all -AC approach. With the M250, the DC circuit is isolated and insulated
from ground, so no Ground Electrode Conductor (GEC) is required for the microinverter. This
further simplifies installation, enhances safety, and saves on labor and materials costs.
The Enphase M250 integrates seamlessly with the Engage® Cable, the Envoy® Communications
Gateway'', and Enlighten®, Enphase's monitoring and analysis software.
PRODUCTIVE
- Optimized for higher -power
modules
- Maximizes energy production
- Minimizes impact of shading,
dust, and debris
enphase®
E N E R G Y
SIMPLE
No GEC needed for microinverter
No DC design or string calculation
required
Easy installation with Engage
Cable
RELIABLE
4th-generation product
More than 1 million hours of testing
and millions of units shipped
Industry -leading warranty, up to 25
years
cGus
Enphase® M250 Microinverter // DATA
INPUT DATA (DO) M250-60-2LL-S22/S23/S24
Recommended input power (STC)
210 - 300 W____
Maximum input DC voltage —�
Peak power trackingvoltage
48 V
27 V - 39 V I
Operating range
Min/Max start voltage
16 V - 48 V
22V / 48 V'
Max DC short circuit current
-Maxinput-current----------
15 A
--10A
OUTPUT DATA (AC)
@208 VAC @240 VAC
Pe output power
250 W 250 W
Rated (continuous) cutout Dower
240 W 240 W
Nominal voltage/range
208 V / 183-229 V 240 V / 211-264 V
Nominal frequency/range; _ _ _
_,60:O P57=61 Hz 60 0 /'57-61• Hz.
a
Extended frequency range'
57-62.5 Hz 57-62.5 Hz
Tower factor P
J>0.95 >0:95
Maximum units per 20 A branch circuit
24 (three phase) 16 (single phase)
Maximum output fault current
850 m_Arms for cycles 850;mA rms for '.6cycles
EFFICIENCY
LCEC weighted efficiency, 240 VAC
96.5%_ _
CEC weighted efficiency, 208 VAC
Peak inverter eficency —
96.0%
966 5"f — I
Static MPPT efficiency (weighted, reference EN50530)
99.4 %
I. Nighttime power consumption --�
65 mW max
MECHANICAL DATA
LAmbient temperature range
-400C to +65°C
Operating temperature range (internal)
-400C to+85°C
Dimensions (WxHxD)
171 mm x 173 min x 30 mm (without mounting bracket)
Weight
2.0 kg
.Cooling
Natural convection - No fans
Enclosure environmental rating
Outdoor - NEMA 6
FEATURES
( Compatibility
Compatible with 60-cell PV modules.
Communication
Power line
Integrated,ground —
The D circuit meets the requirements for ungrounded PV arrays No
NEC 690.35. Equipment ground is provided inthe -Engage Cable. No
additional GEC or ground is required. Ground fault protection (GFP),is
integrated into the microinverter.
Monitoring
Free lifetime monitoring via Enlighten software
Compliance —�
UL1741/IEEE1547, FCC Part 15 Class 8, CAN/CSA-C222 NO: 0-M91,
0.4-04, and 107.1-01
Frequency ranges can be extended beyond nominal if required by the utility
To learn more about Enphase Microinverter technology, r l enphase®
visit enphase.com E N E R G Y
0 2013 Enphase Energy. All rights reserved. All trademarks or brands in this document are registered by their respective owner.