Loading...
HomeMy WebLinkAboutSOIL NUCLEAR GAUGESoil Nuclear Gauge Client: Project: Report Date: 1/24/2018 Life Storage 16-2140.00 Test Method: 6467 Main Street Uncle Bob's Self Storage #011 - Expansion Pert Bt. Lucie BY Buffalo, NY 1422 1 (PERMIT NO: 1610-0382) 8531 S. US Highway 1 9 y FBPE CA#4930 607 NW Commodity Cove St. Lucie County Port St. Lucie, FL 34952 Port St Lucie, FL 34986 Phone:772-924-35751 Fax: 772-924-3680 Test Results Test# Retest Of Test Date ProctorlD Method Soil Classification Optimum Moisture N Maximum Dry Density (pcf) In Place Moisture N In Place Dry Density (pcf) Probe Depth (in) Percent Compaction Min/Max Comp. N Remark 1 911/17 P-2 D N/A 11.6 105.3 9.1 103.1 12 98 95/105 Pass 2 9/1117 P-2 D N/A 11.6 105.3 10.5 100.7 12 96 95/105 Pass 3 9/1/17 P-2 D N/A 11.6 105.3 10.8 103.4 12 98 95/105 Pass 4 9/1/17 P-2 D N/A 11.6 105.3 10.0 102.2 12 97 95/105 Pass 5 9/1/17 P-2 D N/A 11.6 105.3 10.7 102.9 12 98 95/105 Pass 6 911117 P-2 D N/A 11.6 105.3 9.5 104.2 12 99 95/105 Pass 7 911/17 P-2 D N/A 11.6 105.3 8.1 103.4 12 98 951 105 Pass 8 911/17 P-2 D N/A 11.6 105.3 11.0 102.6 12 97 95/105 Pass Test Information Test# Test Location Elevation Reference Gauge Make I Model I SN I Calibrated Field Technician 1 Below Stripped Surface: South Half of Building Area Foundation, Map Location # 1 0-1 Troxler / 3430 / 29796 / Baker, Jeff 2 Below Stripped Surface: South Half of Building Area Foundation, Map Location # 2 0-1 Troxler / 3430 129796 / Baker, Jeff 3 Below Stripped Surface: South Half of Building Area Foundation, Map Location # 3 0-1 Troxler / 3430 / 29796 / Baker, Jeff 4 Below Stripped Surface: South Half of Building Area Foundation, Map Location # 4 0-1 Troxler / 3430 / 29796 / Baker, Jeff 5 Below Stripped Surface: South Half of Building Area Foundation, Map Location # 5 0-1 Troxler / 3430 / 29796 / Baker, Jeff 6 Below Stripped Surface: South Half of Building Area Foundation, Map Location # 6 0-1 Troxler / 3430 129796 / Baker, Jeff 7 Below Stripped Surface: South Half of Building Area Foundation, Map Location # 7 0-1 Troxler / 3430 / 29796 / Baker, Jeff 8 Below Stripped Surface: South Half of Building Area Foundation, Map Location # 8 0-1 Troxler / 3430 / 29796 / Baker, Jeff Pass: Tests results i esrs are -utrem i ransmission trvieu "Backscatter". Ganes calibration data the as /G /O C3 F2 \� IDOMINIC4 �.P.•''V10ENS, tij• moo: •' '•.92 No. 46 O} ' - * �0 it h�rias Dominic MontaI66l,:9Z '/I1ML 111111 t�` Test Reports shall not be reproduced, except in full, without the written approval of GFA International Inc. Digitally signed printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Page 1 of 1 Soil Nuclear Gauge Client: Project: OF04 Report Date: 1/24/2018 Life Storage 16-2140.00 01 Test Method: ASTM D 6938 6467 Main Street Uncle Bob's Self Storage #011 - Expansion Pon St. Lucie Buffalo, NY 14221 (PERMIT NO: 1610-0382) FBPE CA#4930 8531 S. US Highway 1 607 NW Commodity Cwe Port St. Lucie, FL 34952 Pod St Lucie, FL 34986 Phone: 772-92435751 Fax: Tr2-9243580 Test Results Test# Retest Of Test Date ProctorlD Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture N In Place Dry Density (pcf) Probe Depth (in) Percent Compaction Min/Max Comp. (%) - Remark 1 911/17 P-2 D N/A 11.6 105.3 9.1 103.1 12 98 95 / 105 Pass 2 911/17 P-2 D N/A 11.6 105.3 10.5 100.7 12 96 95 / 105 Pass 3 9/1/17 P-2 D N/A 11.6 105.3 10.8 103.4 12 98 95 / 105 Pass 4 9/1/17 P-2 D N/A 11.6 105.3 10.0 102.2 12 97 95 / 105 Pass 5 9/1/17 P-2 D N/A 11.6 105.3 10.7 102.9 12 98 951 105 Pass 6 911/17 P-2 D N/A1 11.6 1 105.3 9.5 104.2 12 99 1 951105 Pass 7 9/1/17 P-2 D N/A 1 11.6 105.3 8.1 103.4 12 98 1 95 / 105 Pass 8 9/1117 P-2 D N/A 11.6 105.3 11.0 102.6 12 97 1 95/105 Pass Test Information Test It Test Location Elevation Reference Gauge Make I Model / SN / Calibrated Field Technician 1 Below Stripped Surface: South Half of Building Area Foundation, Map Location It 1 0-1 Troxler / 3430 / 29796 / Baker, Jeff 2 Below Stripped Surface: South Half of Building Area Foundation, Map Location It 2 0-1 Troxler 13430 / 29796 / Baker, Jeff 3 Below Stripped Surface: South Half of Building Area Foundation, Map Location # 3 0-1 Troxler / 3430 / 29796 / Baker, Jeff 4 Below Stripped Surface: South Half of Building Area Foundation, Map Location # 4 0-1 Troxler / 3430 / 29796 / Baker, Jeff 5 Below Stripped Surface: South Half of Building Area Foundation, Map Location # 5 0-1 Troxler / 3430 / 29796 / Baker, Jeff 6 Below Stripped Surface: South Half of Building Area Foundation, Map Location # 6 0-1 Troxler / 3430 / 29796 / Baker, Jeff 7 Below Stripped Surface: South Half of Building Area Foundation, Map Location # 7 i 10-, Troxler 13430 / 29796 / Baker, Jff 8 Below Stripped Surface: South Half of Building Area Foundation, Map Location # 8 0-1 Troxler / 3430 / 29796 / Baker, Jeff Remarks Comments ���� v)QMINIC Aw_/1,1. Pass: Tests results comply with specifications Tests are "Direct Transmission" (Method A) unless probe depth is noted as Backscafter". Gauge calibration data on file with the testing agency. Pam. ......... ;Iu p�,: .• LICENSE •. ti� h0o����44��46 .�O/20 Ar'tas Dominic Montag9W,F J Test Reports shall not be reproduced, except in full, without the written approval of GFA International Inc. 0P16NAL ENv�` IIIt\1 Digitally signed printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Page 1 of 1 Soil Nuclear Gauge Client: Project: AReport Date: 1/24/2018 Life Storage 16-2140.00 ��a/oap Test Method: ASTM D 6938 6467 Main Street Uncle Bob's Self Storage #011 - Expansion Port St Lucie Buffalo, NY 14221 (PERMIT NO: 1610-0382) FBPE CA A 4930 8531 S. US Highway 1 607" Commodity Cme Port St. Lucie, FL 34952 Port St. Wde, FL M986 Phone: 772-924-35751 Fax: 772-924-3580 Test Results Test# Retest Of Test Date ProctorlD Method Soil Classification Optimum Moisture N Maximum Dry Density (pcf) In Place Moisture (e7o) In Place Dry Density (pcf) Probe Depth (in) Percent Compaction Min/Max Comp. (%) Remark 1 9/1/17 P-2 D N/A 11.6 105.3 9.1 103.1 12 98 951105 Pass 2 911117 P-2 D N/A 11.6 105.3 10.5 100.7 12 96 951 105 Pass 3 911/17 P-2 D N/A 11.6 105.3 10.8 103.4 12 98 95/105 Pass 4 9/1117 P-2 D N/A 11.6 105.3 10.0 102.2 12 97 951105 Pass 5 9/1/17 P-2 D N/A 11.6 105.3 10.7 102.9 12 98 951105 Pass 6 9/1117 P-2 D 1 N/A 11.6 105.3 9.5 104.2 12 99 1 95 / 105 1 Pass 7 9/1/17 P-2 D N/A 11.6 105.3 8.1 103.4 12 98 95 / 105 Pass 8 9/1117 P-2 D N/A 11.6 105.3 11.0 102.6 12 97 951 105 Pass Test Information Test# Test Location Elevation Reference Gauge Make I Model / SN I Calibrated Field Technician 1 Below Stripped Surface: South Half of Building Area Foundation, Map Location # 1 0-1 Troxler / 3430 / 29796 / Baker, Jeff 2 Below Stripped Surface: South Half of Building Area Foundation, Map Location # 2 0-1 Troxler / 3430/29796 / Baker, Jeff 3 Below Stripped Surface: South Half of Building Area Foundation, Map Location # 3 0-1 Troxler / 3430 / 29796 / Baker, Jeff 4 Below Stripped Surface: South Half of Building Area Foundation, Map Location # 4 0-1 Troxler / 3430 / 29796 / Baker, Jeff 5 Below Stripped Surface: South Half of Building Area Foundation, Map Location # 5 0-1 Troxler / 3430 / 29796 / Baker, Jeff 6 Below Stripped Surface: South Half of Building Area Foundation, Map Location # 6 0-1 Troxler / 3430 / 29796 / Baker, Jeff 7 1 Below Stripped Surface: South Half of Building Area Foundation, Map Location # 7 0-1 Troxler / 3430 / 29796 / Baker, Jeff 8 Below Stripped Surface: South Half of Building Area Foundation, Map Location # 8 0-1 Troxler / 3430 / 29796 / Baker, Jeff Remarks Comments �\_ nOMiNI //i i. C Aw_ Pass: Tests results comply with specifications Tests am "Direct Transmission' (Method A) unless probe depth is noted as 'Backscetter'. Gauge calibration data on file with the testing agency. ,20 124/20 it - '!�fn -..s Dominic Montau-4.i. PFy lion ion i Ber.#` 1�46 Staf@iNAL /'/IIl11111\\\\ Test Reports shall not be reproduced, except in full, without the written approval of GFA International Inc. Digitally signed printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Page 1 of 1 Port St. Lucie FBPE CA # 4930 607 NW Cammocily Cave Port St Lucie, FL 34986 Phone: 772.924-3575I Fax: 772-924-3580 Soil Nuclear Gauge Client: Project: Report Date: 1/24/2018 Life Storage 16-2140.00 Test Method: ASTM D 6938 6467 Main Street Uncle Bob's Self Storage #011 - Expansion Buffalo, NY 14221 (PERMIT NO: 1610-0382) 8531 S. US Highway 1 Port St. Lucie, FL 34952 Test Results Test Al Retest Of Test Date ProctorlD Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) Probe Depth (in) Percent Compaction Min/Max Comp. (%) Remark 9 10/11/17 P-2 D N/A 11.6 105.3 9.6 105.9 12 101 95/105 Pass 10 10/11/17 P-2 D N/A 11.6 105.3 9.2 106.1 12 101 95/105 Pass 11 10/11/17 P-2 D N/A 11.6 105.3 10.2 105.2 12 100 95/105 Pass 12 10/11/17 P-2 D N/A 11.6 105.3 9.8 104.0 12 99 95/105 Pass 13 10/11/17 P-2 D N/A 11.6 105.3 10.9 103.6 12 98 95/105 Pass 14 1 1 10/11/17 P-2 D N/A 1 11.6 105.3 10.2 103.5 1 12 1 98 95/105 Pass 15 10/11/17 P-2 D N/A 11.6 105.3 9.3 104.4 12 99 95/105 Pass 16 10/11/17 P-2 D N/A 11.6 105.3 9.5 105.7 12 100 95/105 Pass Test Information _ Test Al Test Location Elevation Reference Gauge Make I Model I SN I Calibrated Field Technician 9 Below Stripped Surface: North Side, Map Location # 1 0-1 Troxler 13430 / 24566 / Baker, Jeff 10 Below Stripped Surface: North Side, Map Location # 2 0-1 Troxler / 3430 / 24566 / Baker, Jeff 11 Below Stripped Surface: North Side, Map Location # 3 0-1 Troxler / 3430 124566 / Baker, Jeff 12 Below Stripped Surface: North Side, Map Location # 4 0-1 Troxler / 3430 / 24566 / Baker, Jeff 13 Below Stripped Surface: North Side, Map Location # 5 0-1 Troxler / 3430 124566 / Baker, Jeff 14 Below Stripped Surface: North Side, Map Location # 6 0-1 Troxler / 3430 / 24566 / Baker, Jeff 15 1 Below Stripped Surface: North Side, Map Location # 7 0-1 Troxler / 3430 124566 / ak Ber, Jeff 16 Below Stripped Surface: North Side, Map Location # 8 0-1 Troxler 13430 124566 / Baker, Jeff Remarks I Comments Pass: Tests results comply With specifications 1Tests am "Backs alteerr"r Gauge calibration ect Transmission" (data on file with theMethod A) unless rtesting agency. obe depth is noted as \,\CENScc * �1No. 84146 * _ Ti;�as Dogj� q Wntan� State'Gt6EgAL ENx� 7jllllllll\\\\ Test Reports shall not be reproduced, except in full, without the written approval of GFA International Inc. Digitally signed printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Page 1 of 1 Soil Nuclear Gauge Report Date: 1/24/2018 Test Method: ASTM D 6938 Pont St. Lucle FBPE CA# 4930 607 NW Commodity Cove Port St Wale, FL 34986 Phone: 772-924-3575 1 Fax: 772-924-3580 Client: Life Storage 6467 Main Street Buffalo, NY 14221 16-2140.00 Uncle Bob's Self Storage #011 (PERMIT NO: 1610-0382) 8531 S. US Highway 1 Port St. Lucie, FL 34952 Expansion Test Results Test# Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture M Maximum Dry Density (pcf) In Place Moisture M In Place Dry Density (pcf) Probe Depth (in) Percent Compaction Min/Max Comp. M Remark 9 10/11/17 P-2 D N/A 11.6 105.3 9.6 105.9 12 101 95 / 105 Pass 10 10/11/17 P-2 D N/A 11.6 105.3 9.2 106.1 12 lot 951 105 Pass 11 10/11/17 P-2 D N/A 11.6 105.3 10.2 105.2 12 100 951105 Pass 12 10/11/17 P-2 D N/A 11.6 105.3 9.8 104.0 12 99 95 / 105 Pass 13 10/11/17 P-2 D N/A 11.6 105.3 10.9 103.6 12 98 95 / 105 Pass 14 10/11/17 P-2 D N/A 11.6 105.3 10.2 103.5 12 98 95 / 105 Pass 15 10/11/17 P-2 D N/A 11.6 105.3 9.3 104.4 12 99 95 / 105 Pass 16 10/11/17 P-2 D N/A 11.6 105.3 9.5 105.7 12 100 95/105 Pass Test Information Test # Test Location Elevation Reference Gauge Make I Model / SN I Calibrated Field Technician 9 Below Stripped Surface: North Side, Map Location # 1 0-1 Troxler 13430 / 24566 / Baker, Jeff 10 Below Stripped Surface: North Side, Map Location # 2 0-1 Troxler 13430 / 24566 / Baker, Jeff 11 Below Stripped Surface: North Side, Map Location # 3 0-1 Troxler / 3430 / 24566 / Baker, Jeff 12 Below Stripped Surface: North Side, Map Location # 4 0-1 Troxler 13430 / 24566 / Baker, Jeff 13 Below Stripped Surface: North Side, Map Location # 5 0-1 Troxler / 3430 / 24566 / Baker, Jeff 14 Below Stripped Surface: North Side, Map Location # 6 0-1 Troxler / 3430 / 24566 / Baker, Jeff 15 Below Stripped Surface: North Side, Map Location # 7 0-1 Troxler / 3430 / 24566 / Baker, Jeff 16 Below Stripped Surface: North Side, Map Location # 8 0-1 Troxler / 3430 / 24566 / Baker, Jeff Remarks I Comments \\\ t t 1 t 1 111 l / /7j7 .\ _nWhiln . /, Pass: Tests results comply with specifications Tests a 'Direct Gauge cal scion (Method A) unls probe on file with the testing depthagency. noted as p�p'.•'•LtGEN3g'•.!Y9 * No 84146 ...Os T �8 TADoftj@ Wnta.i4- tAL � �\\\ f Test Reports shall not be reproduced, except in full, without the written approval of GFA International Inc. Digitally signed printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Page 1 of 1 MIN �S Pont St. Lucie FBPE CA # 4930 607 NW Commodity Cove Part 8L Lucie, FL 34986 Phone: 772-924-3575 1 Fax: 772-924-3580 Soil Nuclear Gauge Report Date: 1/24/2018 Test Method: ASTM D 6938 Client: Project Life Storage 16-2140.00 6467 Main Street Uncle Bob's Self Storage #011 - Expansion Buffalo, NY 14221 (PERMIT NO: 1610-0382) 8531 S. US Highway 1 Port St. Lucie, FL 34952 Test Results Test# Retest Of Test Date ProctorlD Method Soil Classification Optimum Moisture (%) Maximum DryDensity (pcf) In Place Moisture (%) In Place Dry Density (pcf) Probe Depth (in) Percent Compaction Min/Max Comp. (%) Remark 9 10/11/17 P-2 D N/A 11.6 105.3 9.6 105.9 12 101 95/105 Pass 10 10/11/17 P-2 D N/A 11.6 105.3 9.2 106.1 12 101 95/105 Pass 11 10/11/17 P-2 D N/A 11.6 105.3 10.2 105.2 12 100 95/105 Pass 12 10/11/17 P-2 D N/A 11.6 105.3 9.8 104.0 12 99 951 105 Pass 13 10/11/17 P-2 D N/A 11.6 105.3 10.9 103.6 12 98 95/105 Pass 14 10/11/17 P-2 D N/A 11.6 105.3 10.2 103.5 12 98 95/105 Pass 15 10/11/17 P-2 D N/A 11.6 105.3 9.3 104.4 12 99 95/105 Pass 16 10/11/17 P-2 D N/A 11.6 105.3 9.5 105.7 12 100 95/105 Pass Test Information Test # Test Location Elevation Reference Gauge Make I Model / SN I Calibrated Field Technician 9 Below Stripped Surface: North Side, Map Location # 1 0-1 Troxler / 3430 124566 / Baker, Jeff 10 Below Stripped Surface: North Side, Map Location # 2 0-1 Troxler 13430 / 24566 / Baker, Jeff 11 Below Stripped Surface: North Side, Map Location # 3 0-1 Troxler / 3430 124566 / Baker, Jeff 12 Below Stripped Surface: North Side, Map Location # 4 0-1 Troxler / 3430 / 24566 / Baker, Jeff 13 Below Stripped Surface: North Side, Map Location # 5 0-1 Troxler / 3430 / 24566 / Baker, Jeff 14 Below Stripped Surface: North Side, Map Location # 6 0-1 Troxler / 3430 124566 / Baker, Jeff 15 Below Stripped Surface: North Side, Map Location # 7 0-1 1 Troxler / 3430 / 24566 / Baker, Jeff 16 Below Stripped Surface: North Side, Map Location # 8 0-1 Troxler / 3430 / 24566 / Baker, Jeff Remarks I Comments N t t 111 111 / / / / ��\ pMINIC /// Pass: Tests results comply with specifications Tests are "Direct Transmission' (Method A) unless probe depth is noted as 'Backscaaer'. Gauge calibration data on file with the testing agency. p�4 _\GENSF '• �y. * ; No. k4146 TJ��x DOM Wntanq�� State 6f,�/ /SAL 1EN ��� Test Reports shall not be reproduced, except in full, Without the written approval of GFA International Inc. Digitally signed printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Page 1 of 1 Soil Nuclear Gauge Client: Project: G AReport Date: 1 /24/2018 Life Storage 16-2140.00 ' �. Test Method: ASTM D 6938 6467 Main Street Uncle Bob's Self Storage #011 -Expansion Buffalo, NY 14221 (PERMIT NO: 1610-0382) Port at Lucie FBPE CA#4930 8531 S. US Highway 1 607 KW Commodity cove Port St. Lucie, FL 34952 Pod St Lucie, FL 34986 Phone: 772-924-35751 Fax: 772-924-3580 Test Results Test# Retest Of Test Date ProctorlD Method Soil Classification Optimum Moisture M Maximum Dry Density (pcf) In Place Moisture M In Place Dry Density (pcf) Probe Depth (in) Percent Compaction Min/Max Comp. M Remark 17 10/13/17 P-2 D N/A 11.6 105.3 9.9 105.8 12 100 95/105 Pass 18 10/13/17 P-2 D N/A 11.6 105.3 10.1 103.8 12 99 951105 Pass 19 10/13/17 P-2 D N/A 11.6 105.3 9.5 105.3 12 100 981 105 Pass 20 10/13/17 P-2 D N/A 11.6 105.3 10.4 104.4 12 99 98 / 105 Pass 21 10/13/17 P-2 D NIA 11.6 105.3 9.8 105.8 12 100 98/105 Pass 22 10/13/17 P-2 D N/A 11.6 105.3 8.8 1D4 12 99 98/105 Pass Test Information Test # Test Location Elevation Reference Gauge Make / Model I SN I Calibrated Field Technician 17 Below Bottom of Footing: West Footing Run, Northwest Corner of Footing 0-1 Troxler / T3430 / 22260 / Baker, Jeff 18 Below Bottom of Footing: West Footing Run, Center of Footing 0-1 Troxler / T3430 / 22260 / Baker, Jeff 19 Footing: West Footing, Southwest Comer of Footing 0-1 Troxler/ T3430 / 22260 / Baker, Jeff 20 Footing: Column Pads, Northeast Comer of Foundation 0-1 Troxler / T3430 / 22260 / Baker, Jeff 21 Footing: Column Pads, Southeast Corner of Foundation 0-1 Troxler / T3430 / 22260 / Baker, Jeff 22 Footing: North Footing Run, Center of Footing 0-1 Troxler / T3430 / 22260 / 1 Baker, Jeff Remarks Comments Pass: Tests results comply with specifications Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. `\����SpOMINICtijell •'�tCENSE •'•tii' ' 2 11 4 1 461jtii4L EN �� /rllntttl� Test Reports shall not be reproduced, except in full, without the written approval of GFA International Inc. Digitally signed printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Page 1 of 1 ;.r Soil Nuclear Gauge Client: Project: GG Report Date: 1/24/2018 Life Storage 16-2140.00 'AA Test Method: ASTM D 6938 6467 Main Street Uncle Bob's Self Storage #011 - Expansion Port St. Lucie Buffalo, NY 14221 (PERMIT NO: 1610-0382) PBPE CA#4930 8531 S. US Highway 1 607 RW Commodity Cme Port St. Lucie, FL 34952 Port St. Lucie, FL 34986 Phone:772-92435751 Fax: 772-924-3580 ' l Test Results Test# Retest Of Test, Date � Proctor ID Method Soil Classification Optimum Moisture N Maximum Dry Density (pcf) In Place Moisture N In Place Dry Density (pcf) Probe Depth (in) Percent Compaction Min/Max Comp. N Remark 17 10/13/17 P-2 D N/A 11.6 105.3 9.9 105.8 12 100 951 105 Pass 18 10/13/17 P-2 D N/A 11.6 105.3 10.1 103.8 12 99 95/105 Pass 19 10/13/17 P-2 D N/A 11.6 105.3 9.5 105.3 12 100 98/105 Pass 20 10/13/17 P-2 D N/A 11.6 105.3 10.4 104.4 12 99 98/ 105 Pass 21 10/13/17 P-2 D N/A 11.6 105.3 9.8 105.8 12 100 981 105 Pass 22 10/13/17 P-2 D N/A 1 11.6 105.3 8.8 1 104.2 12 1 99 1 981 105 1 Pass Test Information Test # Test Location Elevation Reference Gauge Make I Model I SN I Calibrated Field Technician 17 Below Bottom of Footing: West Footing Run, Northwest Corner of Fooling 0-1 Troxler / T3430 / 22260 / Baker, Jeff 18 Below Bottom of Footing: West Footing Run, Center of Footing 0-1 Troxler / T3430 / 22260 / Baker, Jeff 19 Footing: West Footing, Southwest Corner of Footing 0-1 Troxler / T3430 122260 / Baker, Jeff 20 Footing: Column Pads, Northeast Comer of Foundation 0-1 Troxler / T3430 / 22260 / Baker, Jeff 21 Footing: Column Pads, Southeast Corner of Foundation 0-1 Troxler / T3430 122260 / Baker, Jeff 22 Fooling: North Footing Run, Center of Footing 0-1 Troxler / T3430 / 22260 / Baker, Jeff Remarks Comments Pass: Tests results comply with specifications Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. 00MINICtij� O •.92� * No.84146 I 2 Test Reports shall not be reproduced, except in full, without the written approval of GFA International Inc. Digitally signed printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. a+71V94L \\ I11111111\\ Page 1 of 1 .i1 gIF Port St. Lucie FSPE CA# 4930 607 NW Commodity Cove Part St Lucie, FL 34986 ' Phone: 772-924-3575 1 Fax: 772-9243580 Soil Nuclear Gauge Report Date: 1/24/2018 Test Method: ASTM D 6938 Client: Project: Life Storage 16-2140.00 6467 Main Street Uncle Bob's Self Storage #011 - Expansion Buffalo, NY 14221 (PERMIT NO: 1610-0382) 8531 S. US Highway 1 Port St. Lucie, FL 34952 Test Results Test# Retest Of Test I Date ProctorlD Method Soil Classification Optimum Moisture N Maximum Dry Density (pcf) In Place Moisture N In Place Dry Density (pcf) Probe Depth (in) Percent Compaction Min/Max Comp. (%) Remark 17 10/13/17 P-2 D N/A 11.6 105.3 9.9 105.8 12 100 95/105 Pass 18 10/13/17 P-2 D N/A 11.6 105.3 10.1 103.8 12 99 95/ 105 Pass 19 10/13/17 P-2 D N/A 11.6 105.3 9.5 105.3 12 100 981105 Pass 20 10/13/17 P-2 D N/A 11.6 105.3. 10.4 104.4 12 99 981 105 Pass 21 10/13/1;7 P-2 D N/A 11.6 105.3 9.8 105.8 12 100 981105 Pass 22 10/13/17 P-2 D N/A 11.6 105.3 8.8 104.2 1 12 99 1 981105 Pass Test'Information ' Test # Test Location Elevation Reference Gauge Make I Model I SN I Calibrated Field Technician 17 Below Bottom of Footing: West Footing Run, Northwest Corner of Footing 0-1 Troxler / T3430 / 22260 / Baker, Jeff 18 Below Bottom of Footing: West Footing Run, Center of Footing 0-1 Troxler / T3430 / 22260 / Baker, Jeff 19 Footing: West Footing, Southwest Corner of. Footing 0-1 Troxler / T3430 / 22260 / Baker, Jeff 20 Footing: Column Pads, Northeast Comer of Foundation 0-1 Troxler / T3430 / 22260 / Baker, Jeff 21 Footing: Column Pads, Southeast Corner of Foundation 0-1 Troxler / T3430 / 22260 / Baker, Jeff' 22 Footing: North Footing Run, Center of Footing 0-1 Troxler / T3430 / 22260 / Baker, Jeff Remarks Comments Pass: Tests results comply with specifications Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. �DOMINIC4j, �O�P.• LICENSE •. 2� * No. AA 146 /20•'1 Test Reports shall not be reproduced, except in full, without the written approval of GFA International Inc. Digitally signed printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. IIIlIII1111 Page 1 of 1 i f� �fcTti� Port St Lucie FBPE CA# 4930 607 NW Commodity Cave Part St Lucie, FL 34986 Phone: 772-924-35751 Fax: 772-924-3580 Soil Nuclear Gauge Report Date: 1/24/2018 Test Method: ASTM D 6938 Client: Life Storage 6467 Main Street Buffalo, NY 14221 16-2140.00 Uncle Bob's Self Storage #011 - Expansion (PERMIT NO:1610-0382) 8531 S. US Highway 1 Port St. Lucie, FL 34952 Test Results Test# Retest Of Test Date ProctorlD Method Soil Classification Optimum Moisture (°70) Maximum Dry Density (Pcf) In Place Moisture (%) In Place Dry Density (PCf) Probe Depth (in) Percent Compaction Min/Max Comp. (%) Remark 23 1/8118 P-2 D N/A 11.6 105.3 11.0 105.1 12 100 98/ 105 Pass 24 1/8/18 P-2 D N/A 11.6 105.3 9.3 107.5 12 102 98/ 105 Pass 25 118/18 P-2 D N/A 11.6 105.3 9.5 107.7 12 102 98 / 105 Pass 26 1/8/18 P-2 D N/A 11.6 105.3 10.2 106.4 12 101 98/ 105 Pass Test Information Test # Test Location Elevation Reference Gauge Make I Model I SN I Calibrated Field Technician 23 Above Bottom of Pipe: Water Main Service, North Side of Pipe 0-1 Troxler / T3430 / 36304 / Baker, Jeff 24 Above Bottom of Pipe: Water Main Service, South Side of Pipe 0-1 Troxler / T3430 / 36304 / Baker, Jeff 25 Above Top of Pipe: Water Main Service 1-2 Troxler / T3430 / 36304 / Baker, Jeff 26 Above Top of Pipe: Water Main Service 2-3 Trader T3430 / 36304 / Baker, Jeff Remarks Comments Pass: Tests results Comply with specifications Tests are "Direct Transmission' (Method A) unless probe depth is noted as 'Backscatter. Gauge calibration data on fie with the testing agency. S'•�?CENSF' * ; �No. 84146 1DroAL ENv 11/IIIII W Test Reports shall not be reproduced, except in full, without the written approval of GFA International Inc. Digitally signed printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Page 1 of 1 Soil Nuclear Gauge Report Date: 1/24/2018 Test Method: ASTM D 6938 Port St. Lucia FBPE CA# 4930 607 KW Commodity Cove Port St Lucie, FL 34986 Phone: 772-924-35751 Fax: 772-924-3580 Client: Life Storage 6467 Main Street Buffalo, NY 14221 16-2140.00 Uncle Bob's Self Storage #011 - Expansion (PERMIT NO:1610-0382) 8531 S. US Highway 1 Port St. Lucie, FL 34952 Test Results Test# Retest Of Test Date ProctorlD Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture N In Place Dry Density (pcf) Probe Depth (in) Percent Compaction Min/Max Comp. N Remark 23 118/18 P-2 D N/A 11.6 105.3 11.0 105.1 12 100 98 / 105 Pass 24 1/8/18 P-2 D N/A 11.6 105.3 9.3 107.5 12 102 98 / 105 Pass 25 118/18 P-2 D N/A 11.6 105.3 9.5 107.7 12 102 981 105 Pass 26 1/8118 P-2 D N/A 11.6 105.3 10.2 106.4 12 101 98/ 105 Pass Test Information Test # Test Location Elevation Reference Gauge Make I Model I SN I Calibrated Field Technician 23 Above Bottom of Pipe: Water Main Service, North Side of Pipe 0-1 Troxler / T3430 / 36304 / Baker, Jeff 24 Above Bottom of Pipe: Water Main Service, South Side of Pipe 0-1 Troxler / T3430 / 36304 / Baker, Jeff 25 Above Top of Pipe: Water Main Service 1-2 Troxler / T3430 136304 / Baker, Jeff 26 Above Top of Pipe: Water Main Service 2-3 Troxler / T3430 / 36304 / Baker, Jeff Remarks Comments Pass: Tests results comply with specifications Tests are "Direct Transmission" (Method A) unless probe depth is noted as 'Backscattef. Gauge calibration data on file with the testing agency. 5.•• 'O o�P. •' �tCENSF' • ti� ..0; 14,* 1� 146 Test Reports shall not be reproduced, except in full, without the written approval of GFA International Inc. Digitally signed printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Page 1 of 1 Soil Nuclear Gauge g Client: Project: 6f� Report Date: 1 /24/2018 Life Storage 16-2140.00 �`ANgpOA Test Method: ASTM D 6938 6467 Main Street Uncle Bob's Self Storage #011 - Expansion Port SL Lucie Buffalo, NY 14221 (PERMIT NO: 1610-0382) FBPE CA#4930 8531 S. US Highway 1 607 KW Commodity cove Port St. Lucie, FL 34952 Part St. Lucie, FL 34986 Phone: 772-924-3575 1 Fax: 772-92473580 Test Results Test# Retest Of Test Date ProctorlD Method Soil Classification Optimum Moisture (%) Maximum Dry Density (Pcf) In Place Moisture (%) In Place Dry Density (pcf) Probe Depth (in) Percent Compaction MinlMax Comp. N Remark 23 118/18 P-2 D N/A 11.6 105.3 11.0 105.1 12 100 981 105 Pass 24 1/8118 P-2 D N/A 11.6 105.3 9.3 107.5 12 102 98 / 105 Pass 25 1/8/18 P-2 D N/A 11.6 105.3 9.5 107.7 12 102 98 / 105 Pass 26 118118 P-2 D N/A 11.6 105.3 10.2 106.4 12 101 98/ 105 Pass Test Information Test # Test Location Elevation Reference Gauge Make I Model I SN I Calibrated Field Technician 23 Above Bottom of Pipe: Water Main Service, North Side of Pipe 0-1 Troxler / T3430 / 36304 / Baker, Jeff 24 Above Bottom of Pipe: Water Main Service, South Side of Pipe 0-1 Troxler / T3430 / 36304 / Baker, Jeff 25 Above Top of Pipe: Water Main Service 1-2 Troxler / T3430 / 36304 I Baker, Jeff 26 Above Top of Pipe: Water Main Service 2-3 Troxler / T3430 136304 / Baker, Jeff Remarks Comments Pass: Tests results comply with specifications Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. \��\\�OOMINICyy�O �i� O�Q;.• OCENSF '•N9 * No.84146 **=_ ^ IvrkL \\ /IIIIIIt\\ Test Reports shall not be reproduced, except in full, without the written approval of GFA International Inc. Digitally signed printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Page 1 of 1 one to odb's '510rcy� 10 -/ /- /7 le- 1 yI Li114i FLR L m BAMTY RAN ALO TX Result Report P 1 01/24/2010 14:59 Serial No. A5CO011021494 TC: 496326 Addressee Start Time Time I Prints Result Note 7723352042 01-24 14:54 00:04:19 11101/001 OR Note Result Te �� 2580 WaT SI SPECIALISTS INC. 2560 ARET . PARKWAY ALPHAHETTA. GA 30004-7426 IM1111 Y 'k l� PO6� Oov6BBev AEO U=� 1810 awE EENOP F M4S 3 E 3 G 53 ST OSL FL 34453 OFF, Send. 6 1d •••O � e�m,. O®.• ® p h�l O �e 01 /14/1 B r Tw 260.00 059469211 REYIT TO 1..II.11... 11...11.... I..II..1..1.1 ..1..11 CYTOMETRY SPECIALIIAUIINC.STS IN 2560 WESTSI 3000WY ALPHAHETTA, 300D4-7426 0 Pbnw el.m4 bva 1/ vtlYrovv 1� Inwtrse[ v. Invu.�nw Inbrmtllen :.0 cwax¢ scau • ✓a J \S � srt ��yt �•\ `�4 i� ^' •\ sna co-nn "r (anrml LOCATION MAP 11 ar.9. 0 tbxG W weu.oevn MGM WPM- 9%EFkTi'� ! 8. "vami iH iE is3 W t_i m r. LEGAL DESCRIPTION e!e &b s S-loro9c 204O.00 ew &- FAce_ Ibl�-03SZ Soil Nuclear Gauge Report Date: 5/22/2018 Test Method: ASTM D 6938 Port St Lucie FBPE CA # 4930 607NW Commodity Cwe Port St Lucie, FL 34986 Phone: 772-92435751 Fax: 772-9244580 Client: Life Storage 6467 Main Street Buffalo, NY 14221 16-2140.00 Uncle Bob's Self Storage #011 - Expansion (PERMIT NO: 1610-0382) 8531 S. US Highway 1 Port St. Lucie, FL 34952 Test Results Test # Retest Of Test' Date! Proctor ID Method Soil Classification Optimum Moisture M Maximum Dry Density (pcf) In Place Moisture M In Place Dry Density (pcf) Probe Depth (in) Percent Compaction Min/Max Comp. M Remark 27 5/11/18 P-2 D N/A 11.6 105.3 9.8 103.4 12 98 95/ 105 Pass 28 5/11/18 P-2 D NIA 11.6 105.3 10.6 103.2 12 98 95 / 105 Pass 29 5/11/18 P-2 D N/A 11.6 105.3 9.5 103.1 12 98 951105 Pass Test Information Test # Test Location Elevation Reference Gauge Make / Model I SN I Calibrated Field Technician 27$ic'Cevalk�MLo lion #'j1W 0-1 Troxler / 3430 / 24566 / Baker, Jeff 28 -Slffewelk: Map Locatio if2/ 0-1 Troxler 13430 / 24566 / Baker, Jeff 29 Sidewalk: Map Localioirrg,3 0-1 Troxler 13430 / 24566 / Baker, Jeff Remarks Comments Pass: Tests results comply with Specifications Tests are "Direct Transmission' (Method A) unless probe depth is noted as "Backscatter . Gauge calibration data on file with the testing agency. A ,t�h,`NY � , r3 " _ude County, Permitting Test Reports shall not be reproduced, except in full, without the written approval of GFA International Inc. `t1t1111111//7/ NN..... ocENSc- •' • -•0 KenppT�T:E OF ••�(/�� Pr6ibflBtor 8 Stater�d�4L� vv� //nllnll`�� Digitally signed printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Page 1 of 1 �b10—(D312 . Soil Nuclear Gauge Client: Project: Gfp Report Date: 5/2212018 Life Storage 16-2140.00 Test Method: ASTM D 6938 6467 Main Street Uncle Bob's Self Storage #011 - Expansion Pori St. Lucie Buffalo, NY 14221 (PERMIT NO: 1610-0382) 11PECA#4930 8531 S. US Highway 1 607 NW Commodity Cave Port St. Lucie, FL 34952 Pod St. Wcie, FL U986 Phone: 772-924-3575 1 Fax: 772-9243580 Test Results Test# Retest Of Tes� Date ProctorlD Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) Probe Depth (in) Percent Compaction Min/Max Comp. (%) Remark 27 5/11/18 P-2 D N/A 11.6 105.3 9.8 103.4 12 98 95/ 105 Pass 28 5/11/18 P-2 D N/A 11.6 105.3 10.6 103.2 12 98 95 / 105 Pass 29 5/11/18 P-2 D N/A 11.6 105.3 9.5 103.1 12 98 95 / 105 Pass Test Information Test # I Test Location I Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 27 Sidewalk: Map Location # 1 0-1 Troxler / 3430 / 24566 / Baker, Jeff 28 Sidewalk: Map Location # 2 0-1 Troxler / 3430 / 24566 / Baker, Jeff 29 Sidewalk: Map Location # 3 0-1 Troxler / 3430 / 24566 / Baker, Jeff Remarks Comments Pass: Tests results comply with specifications Tests are "Direct Transmission" (Method A) unless probe depth is noted as "eackscafter". Gauge calibration data on file with the testing agency. RE�EiVED MAY ? 3 31 Lucie County, Permitting Test Reports shall not be reproduced, except in full, without the written approval of GFA International Inc. `t1tllllll///// "•KFNT��'% •' ENSF''•, 0 6321 41417 OF DAPAL //llllttlt` Digitally signed printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Page 1 of 1 ril Port St Lucie FSPE CA# 4930 607 NW Commodity Cove Port SL Lucie, FL 34966 Phone: 772-924-35751 Fax: 1lAro D I Soil Nuclear Gauge Report Date: 5/22/2018 Test Method: ASTM D 6938 Client: Project: Life Storage 16-2140.00 6467 Main Street Uncle Bob's Self Storage #011 - Expansion Buffalo, NY 14221 (PERMIT NO: 1610-0382) 8531 S. US Highway 1 Port St. Lucie, FL 34952 Test Results Test# Retest Of Test Date ProctorlD Method Soil Classification Optimum Moisture N Maximum Dry Density (pcf) In Place Moisture N in Place Dry Density (pcf) Probe Depth (in) Percent Compaction Min/Max Comp. N Remark 27 5/11/18 P-2 D N/A 11.6 105.3 9.8 103.4 12 98 951 105 Pass 28 5/11/18 P-2 D N/A 11.6 105.3 10.6 103.2 12 98 95 / 105 Pass 29 5/11/18 P-2 D N/A 11.6 105.3 9.5 103.1 12 98 95/ 105 Pass Test Information Test # Test Location I Elevation Reference Gauge Make I Model I SN / Calibrated Field Technician 27 Sidewalk: Map Location # 1 i 12-1 Troxler / 3430 / 24566 / Baker, Jeff 28 Sidewalk: Map Location # 2 0-1 Troxler / 3430 / 24566 / Baker, Jeff 29 Sidewalk: Map Location At 3 1 10-1 Troxler / 3430 / 24566 / Baker, Jeff Remarks Comments Pass: Tests results comply with specifications Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. M,av -, 3 °018 ST. Lucie County, \\t11111111//// NN' KENT .• _NCENSF •. 6321 � gyp' FF 85 201 = ' . ent, STATE OF '•�(/44/� GINAL EN /llllll1W Test Reports shall not be reproduced, except in full, without the written approval of GFA International Inc. Digitally signed printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Page 1 of 1 L)n(.1.p, u.Jc./ V .c( I Jl,(1V7. atY C� -1(D • zl %(O-oo U Stc((WaI«- 1�ol0-03�2 �=rr-tr3 HITCH MUND ® DHA c scI= as•�a s IennaouY.e: GY^eas gar mmeawe iw �:.) �qg—"- -�—_—ro® � �nw manim 6�l rw Y safDh rwnW) �N I�/I�I��j�TT �m�~� �`\ \\\ ` nmsnxce'7mEmmu r 'A '\ \ d�G �C\ E0.VMO:W �\\ VSE:VXDD- ?\\am �. •.e QIrrYEE W O7z ue F � Y12 r0.wYu scow Eais-a