HomeMy WebLinkAboutSOIL NUCLEAR GAUGEI
Soil Nuclear Gauge
Client:
Project:
QF04,0,
Report Date: 10/9/2017
Life Storage
16-2140.00
Test Method: ASTM D 6938
6467 Main Street
Uncle Bob's Self Storage, Port Saint Lucie
Port St. Lucie
Buffalo, NY 14221
8351 South Federal Highway
FBPE CA#4930
Port Saint Lucie, FL 34952
607
Stude,FLCommodity3Cove
Pod St Lucie. FL 349a8
Cull
Phone: ]]2-924-35751 Fax: T2-924-3ILE
Test Results
Test#
Retest
Of
Test
Date
ProctorlD
Method
Soil
Classification
Optimum
Moisture
N
Maximum
Dry Density
(pcf)
In Place
Moisture
N
In Place
Dry Density
(pcf)
Probe
Depth
(in)
Percent
Compaction
Min/Max
Comp.
N
Remark
1
911/17
P-2
D
N/A
11.6
105.3
9.1
103.1
12
98
951105
Pass
2
911/17
P-2
D
N/A
11.6
105.3
10.5
100.7
12
96
95/105
Pass
3
9/1/17
P-2
D
N/A
11.6
105.3
10.8
103.4
12
98
95/105
Pass
4
9/1/17
P-2
D
N/A
11.6
105.3
10.0
102.2
12
97
95/105
Pass
5
1
9/1/17
P-2
D
N/A
11.6
105.3
10.7
102.9
12
98
95/ 105
Pass
6
9/1/17
P-2
D
N/A
11.6
105.3
9.5
104.2
12
99
95 / 105
Pass
7
9/1/17
1 P-2
D
N/A
11.6
105.3
1 8.1
1 103.4
1 12
98
1 95/105
Pass
8
1
9/1/17
P-2
D
N/A
11.6
105.3
11.0
102.6
12
97
95/105
Pass
Test Information
Test #
Test Location
Elevation
Reference
Gauge
Make I Model I SN
Field Technician
1
Below Stripped Surface: South Half of Building Area Foundation, Map Location # 1
0-1
Troxler 3430 29796
Baker, Jeff
2
Below Stripped Surface: South Half of Building Area Foundation, Map Location # 2
0-1
Troxler 3430 29796
Baker, Jeff
3
Below Stripped Surface: South Half of Building Area Foundation, Map Location # 3
0-1
Troxler 3430 29796
Baker, Jeff
4
Below Stripped Surface: South Half of Building Area Foundation, Map Location # 4
0-1
Troxler 3430 29796
Baker, Jeff
5
Below Stripped Surface: South Half of Building Area Foundation, Map Location # 5
0-1
Troxler 3430 29796
Baker, Jeff
6
Below Stripped Surface: South Half of Building Area Foundation, Map Location # 6
0-1
Troxler 3430 29796
Baker, Jeff
7
Below Stripped Surface: South Half of Building Area Foundation, Map Location # 7
0-1
Troxler 3430 29796
Baker, Jeff
8
Below Stripped Surface: South Half of Building Area Foundation, Map Location # 8
0-1
Troxler 3430 29796
Baker, Jeff
' Remarks '
I Comments
``\\� tt 11 I I I I ! ! u !, %.
Pass: Tests results comply with specifications
Tests areprobe
agency. noted as
calibration(Methdata od A)filunless
ratterect Transmission*
withDA/vL-_
SCANNED
BY
St. Lucie County
OCT 10 OECD
Test Reports shall not be reproduced, except in full, without the written approval of GFA International Inc.
N
�/ yF 10/09/2017 =
tl. Danforth, P.E.
%i���AL 1Er ��•
Digitally signed printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.
Page 1 of 1