Loading...
HomeMy WebLinkAboutPRODUCT INFORMATIONAs MITSUBISHI ELECTRIC COOLING & HEATING Job Name: 1'Y1mSEROGS System Reference: I Date: Indoor Unit MSY-036NA-8 7gg�MR 5 Wireless Renwle CantraDer GENERALFEATURES • Catechin and anti -allergy enzyme filters for high air -purification capabilites • Updated sleek, compact Indoor unit design • Remote -controlled wide airflow enables Ideal horizontal air distribution • Self -check function— onboard diagnostics • Advanced microprocessor control • Auto restart following a power outage • Hand-held Wireless Remote Controller • Anti -allergy Enzyme Filter ` • Limited warranty: five years parts and seven years compressors ACCESSORIES Outdoor Unit o Drain Socket Assembly(MAC-S11 DS) Indoor Unit ❑ Three -pole Disconnect Switch (TAZ-MS303) ❑ Condensate Pump (230V, S13100-230) Controller Options o Wireless Wall -mounted Remote Controller Kit (MHK1)' • Portable Central Controller (MCCH1)• a Outdoor Air Sensor(MOS1)` ❑ Wired Wall -mounted Controller (PAR-31 MAA requires MAC-3331F)' ❑ Simple MA Remote Controller (PAC-YT53CRAU requires MAC-3331F)' 'See Submittal for information on each option. ❑ System Control Interface (MAC-3331F) ❑ Remote Temperature Sensor (1021.I1(0-307) ❑ Lockdown Bracket for Hand-held Controller (RCMKPI CB) Outdoor Unit MUK0361,1A-1 SCANNED BY St. Lucie County ,::3 ♦ham ( 1 �+ 4 r 1 s Q • , nn� 8P Specifications are subject to change without notice. 0 2015 Mitsubishi Electric US, Inc. Cooling` Rated Capacity ...............................34,600 Btu/h Minimum Capacity ........... .................. 9,800 Bluth SEER......................................15.1 Btu/h/W Total Input ...................................... 4,240 W • Rating Conditions perAHRI Standard Cooling Indoor. 80O F (270C) DB / 67° F (19° C) NB Cooling Outdoor. 950 F (35° C) DB / 75° F (24° C) MIS ELECTRICAL REQUIREMENTS Power Supply .................... 208 / 230V, 1-Phase, 60 Hz Breaker Size........................................25 A Voltage Indoor - Outdoor S1-S2 ...................... AC 208 / 230V Indoor - Outdoor S2-S3 ...........................00 t24V Indoor- Remote Controller ..................... MHKt DC 3V PAR-31 MAA DC 12V PAC-YT53CRAU DC 12V OPERATING RANGE Indoor Intake Air Tern Outdoor Intake Air I Tema. Maximum 90° F (32o C) OB 115° F (46° C) DB 73° F 23 Cj WB Cooling 67a F (19- C) DB Minimum 57 F14"C WB 14° F (-10- C) DB Notes: Specifications are subject to change without notice. V 2015 Mitsubishi Eleddc US, Inc. Indoor Unit MCA............................................... 1 A Blower Motor (ECM) ............................. 0.76 F.L.A. Airflow Cooling (Lo - Med - Hi - Powerful) 389 - 639 - 848 - 887 Dry CFM 350 - 576 - 763 - 798 Wet CFM Sound Pressure Level Cooling (Lo - Med - Hi - Powerful) ....... 32 - 42 - 49 - 51 dB(A) DIMENSIONS UNIT INCHES /MM W 46-1/16 / 1 170 D 11-5/8 / 295 H 14-3/8 / 365 Weight....................................40 lbs. / 18 kg External Finish .................... Munsell No. 1.OY 9.2 10.2 Field Drainpipe Size O.D...................... 518" 115.88 mm Remote Controller ................................ Wireless c Outdoor Unit Compressor ...................... DC Inverter -driven Rotary MCA.............................................. 21 A Fan Motor (ECM) ............................... 0.93 F.L.A. Sound Pressure Level Cooling ........................................ 56 dB(A) DIMENSIONS INCHES/MM W 33-1 /16 / 840 D 13 / 330 H 33-7116 / 849 Weight...................................126 lb& 157 kg External Finish ......................Munsell No. 3Y 7.8 / 1.1 Refrigerant Type ................................... R410A Refrigerant Pipe Size O.D. Gas Side ................................ 5/8" / 15.88 mm Liquid Side ................................ 3/8" / 9.53 mm Max. Refrigerant Pipe Length ..................... 100' / 30 m Max. Refrigerant Pipe Height Difference ............. 50' / 15 m Connection Method .................................Flared 7o"rti. ,yftq e eaa q; € �Vw,� •c. MUY-D36NA4 Required Space (Indoor Unit) Man - For left: left, back; or left, bottom piping (using spacer): lit/a or more im L Air 0 REQUIRED SPACE yen as a rule ',r- 20 inch or more if Me back. both sides and top are open Unit: inch 2.6116 yb a Wireless remote controller piping Incitation Ugwd tins o9619-11/16 (Ramd connection o318) 01-1/40.0 •gftlilz Gas9ne ON 164/8 (Joint connection o518) al-1511601L of-0141.0 Joint 0518 (Flared cavection o518) 01.151160.D d1-1141D. Drain hosel Insulatimol-Ire Connected pad69/160A Unit: inch Open as a rule 20 inch or more if Me front and bom sides are open 4 Inch or more / M as or more if there are obstacles ff to Ma sides - ' MITSUBISHI COUf\ ELECTRIC COOLING & S COPY130 Sat le ice ep uabHEATING Intertek Suwanee, GA 30024 FILE TDII Free: 600-4334822 ervAv.mehvaccom FORM# MSY-D36NA-8 - MUY-D36NA-1 - 201503 Specifications are subject to change without notice. 0 2015 Mitsubishi Electric US, Inc