Loading...
HomeMy WebLinkAboutDESIGN CRITERIASCANNED Page 1 of 3 By St. Lucie County DESIGN OF HAPCO ALUMINUM LIGHTING POLES CATALOG No. RTA21B6BE PROJECT: SAVANNA CLUB EAGLE'S LANDING POOL St. Lucie County, Florida DESIGN CRITERIA: FLORIDA BUILDING CODE 2014 170 MPH (max with Gust) Using ASCE7-10, Per Section 1601 & 1819 Date: 8-9-2017 References: ASCE 7-10 — Minimum Design Loads for Buildings & Other Structures Florida Building Code 2014 Chapter 16 for Structures and 18 for Foundations Cat.I AASHTO Standard Specifications for Highway Signs, Luminaries and Traffic Signals 1994 & 2010 FDOT Standard Specifications Catalog Cut Sheets Prepared By: James E. Wild, P.E. 592 Lancaster Gate SE. North Canton Ohio 44709 Submitted By: Precision Outdoor Lighting, Inc. 3832 Shipping Ave Miami, Fl 33146 POLE ID RA21B6BE By: J.Wild, PE ver 10-1-12 "% (29' OAH, 21' MH) Date: 8/9/2017 Project: . Savanna Club Eagle's Landing Pool General Data: Calculations: ASCE 7-10 & 2014 FBC C.G of Fixture 21 ft q = 0.000256 *VA 2 = 73.984 psf Base Height Above Ground 0 ft Wind Pressure = 0.00256'Kz'Kzt•Kd'v^2 C.G. of Fixture from Pole CL 1 ft P = 65.39 psf EPA of Fixture (total) 1.1 sf Fixtures: Weight of Fixture (total) 40 Ibs Dead Load 40 Ibs Wind Speed (V) 170 mph Wind Load 71.93 Ibs OT Moment 1510.55 ft-Ibs Material for Pole & Arm Alum 6063 Pole Data: Pole: Shape of Pole Rd Dead Load: 82.25 Ibs Embedment Depth 8 ft EPA 4.13 sf Length 29 ft Wind Load: 270.35 Ibs Base OD 6 in C.G. of Pole 14.50 ft Top OD 4.5 in OT Moment 3920.12 ft-Ibs Wall Thickness 0.125 in Torsion M 71.93 ft-Ibs Aver. Unit Wt /LF 2.84 Ibs/If Area Aver. 2.01 in^2 Sum of Loads @ Base: r = (OD-t)12 aver 2.56 in axial 122.25 Ibs r = (od@base-t)/2 @ base 2.94 in shear 342.28 Ibs Area @ Base 2.31 in moment 5430.67 ft-Ibs Section Modulus @ Base 3.39 in^3 torsion 71.93 ft-Ibs Mom. of Inertia @ Base 9.95 in14 Torsion Constant (J) 6.77 in^4 Projected Area of Pole 9.19 sf Exposure category C Kz for Pole: 0.91 Cf for Pole: 0.45 (based on wind tunnel testing) Kzt - use 1.0 1.00 Kd : 0.97 Overload factor = 1.33 Stress Calculations: Allowable Stresses: Pole: fa = axial / Area = 53.0 psi Fa = Fcy/ny = 17,727 psi fb = OT Mom / Sect Mod. = 19241.5 psi Fb = 1.17-Fty/1.65 = 17,727 psi fv = (2'shear/a)+(torsion/1) = 424.3 psi or Fb = 1.24'Ftull.95 = 19,077 psi CSR's: use use 17,727 psi Post: CSR = fa/Fa + (fb/Fb)+(fv/Fv)^2 = 0.82 Fv = Fsy/ny = 13,473 psi csr < 1.0 so OK! Check Embedment Depth of Pole: REF: FBC Table 1819.6 &1819.7.2.1 d=•0.5A(1 +(1 +(4.36h/A))^1 /2) Where: A = 2.34P/(S1 b), where S1 = 2'S'd/3, S = 150.00 psf d= Depth of Embedment in feet 8.00 ft b = Diam of Post, Concr or compacted fill 0.50 ft S1 = Soil Pressure = 800 psf (load that produces GrdLine Mom) P = Maximum Lateral Load 258.60 Ibs - load that produces GrdLine Mom) (assume load at fixture height) h = Dist from Load to Groundline 21 ft - assume load at fixtures IN"#,,, SOLVE -for do -- A = 2.34P/(S1b) = 1.51 44 ♦e 1 d=0.5A(1+(1+(4.36hlA))^1/2)= 6.69 ft .`0 , " I P nfQaao Embedment Depth Shown > Calculated so OK 01. fE OF 0 R ;; "A" 9FT BURIAL F ounting Height: 21 Wall Thickness: in Butt Diameter: 6 in Tap Diameter:—z4.5 in_ Base Diameter: in Bolt Circle: 4 in Bolt Projection: in Bolt Size: Net Weight: 70 minary Weight: 100 Arm Length: Quantity: Club Eagle's Landing Pool "D" i Tap Diameter RTA21B6BE-BH Notes: 21 FT POLE EPA- Embedded Cast Alum: Pole Cap With Stainless Steel Screws RTA DIRECT BURIED for Lithonia KAX2 LED Luminaire / Arm Drilling Per Customer Specifications RTA2i1666E BH Optional Tenon Mounting (specify) Internal Damper (For Poles with 6"-10" butt diameters only) (Installed) Reference pages 105-106 for bull horn arms and "B" Wall Alloy 6063 T6 CrosSarms Satin Ground or Powder Coated Finish per Customer Specification Grounding Provision SLA WARNING: Do not install light pole without luminaire. - Reinforced Handhole with Cover and Stainless Steel Hex Hd Screws for Poles (3" x 5" For 6" 'Poles 4" x 6" for 7" and larger Poles) - Handhole (2" x 5'1 with Cover and Stainless Steel Hex Hd Screws for Poles with 5" butt diameter ,/ "C" Butt Diameter Ground Line 13/4" Dia. Wire Hole With 1 1/2" I.D. Rubber Grommet 34' O� Maximum EPA 70: 11.9 80: 8.3 90: 6.2 100: 4.8 110: 3.8 Accessories Your Name: Representative Name: Architect Name: Project Name: Customer P.O. #: Finish: SH--WHITE FINISH Date: Notes: Visit Hapco.com or call 800-368-7171 or fax 276-628-7707 v.2.03 I