HomeMy WebLinkAboutMISC EMAILC.D. HAIR AR ITECT; AR96135 8461 Lake Worth Road, Suite 159 Lake Worth, FL 33467 (561) 209.6050 AR96135 April 13th 2018 Building Inspector St Lucie County Building Department 121 SW Port St Lucie Blvd Port St Lucie, FL 34984 Re:1709-0462 7041 US Hwy 1, Port St. Lucie SCANNED BY 5t. Lucie County The purpose of this letter is to describe the method of attachment of the new exterior wall masonry at the rear of the tenant space to the existing masonry construction. The new masonry is doweled into the existing masonry with #5 dowels, 12" long at 24" o.c. vertically and horizontally. Embed is 6" each side. Each side has filled cells. This is in lieu of the masonry ties as shown on the drawings. If you should have any questions or concerns, please do not hesitate to contact me. Chris Hair —Architect ;C.O. HAIR AR ITECT: ' AR96136 r U - -NOV 2 1 2017 SCANNED BY BY: 8461 Lake Worth Road Suite 159 Luciee Lake Worth, FL 33467 St County (561) 209.6050 AR-96135 Narrative DATE: 11.17.17 COMM: 17-015 TO: St Lucie County RE: Permit revisions FROM: Chris Hair- Architect ADG MRI CC: Kevin Johnson F 1709-0462 Please see below responses to the permit comments. The revisions are marked as Revision no. 01 and dated 11.17.17 Zoning- Galbraith: 1. Comment: Resolution 07-293 for St Lucie Oaks Commercial indicate a 4,613 sf restaurant. To be able to change the use to a medical center the resolution will need to be changed. Please contact planning Dept for information about a major adjustment to the existing PNRD which requires a Board of County Commissioners approval. Response: An amendment to the PNRD has been completed. r Building- Ed Roseberrv: Comment: Please show FBC accessibility for all counter heights, including Break Room and Examination Treatment areas. Response: The door leading into the MR Exam room has been changed to swing outwards. Please see revised sheet A210. Note, the door does not have a combination of a closer and a latch. The counter heights for all of the counter heights including the Break Room were originally shown on sheet A320 of the permit set Note: The Break room sink cabinet doors have an integral kick which allows front access with the required knee clearance. Refer to cabinet section 04 on Sheet A320 on the originally submitted permit set 2. Comment: Please submit one corrected digital plan on CD and triplicate corrected plan sheets. Response: Noted, will comply. END OF NARRATIVE 9 Page 2 MECHANICAL. ELECTRICAL, P L U M B I N G, FIRE PROTECTION. & COMMISSIONING November 17, 2017 Planning & Development Services Building & Code Regulation Division Fort Pierce, FL 34982 Project Name: Advanced Diagnostic Group Project Address: 7041 S Us hwy 1. Port St Lucie, FL. Permit #: 1709-0462 Subject: Response to comments issued by Building Department Bold print refers to response to Department Comments Italic print refers to Department Comments Mechanical Plans Examiner: Carl Peterson Date of Comments: 10/26/17 1. Comment: Please show that air handler units are not in what is considered attic space in accordance with 403.2.7.6 of the 2014 Florida Energy Code. Response: Refer to added note on sheet M-1 for clarity. The AHUs are not located on what is considered attic space in accordance with 403.2.7.6 of the 2014 Florida Energy Code. 1 www.beacon-eng.com 625 Casa Loma Blvd. Suite 106 Boynton Beach, FL 33435 Tel no: 561.424.3270 L MECHANICAL, ELECTRICAL, PLUMBING, FIRE PROTECTION, & C O M M I S S I O N I N G 2. Comment: Please remove all references to the international codes and please reference the Florida Building Codes on page M3.1 per 101.4 of the 2014 Florida Building Code. Response: Refer to revised sheet M-3 for corrections. 3. Comment: Please submit a Commissioning Plan per Florida Building Code Energy Section C408.2.1. Response: Refer to revised sheet M1.1 for added Commissioning Notes and the Chiller Installation Checklist. END OF RESPONSES If you have any further questions, or if we can be of any further assistance, please do not hesitate to call. Sincerely, Angelo L. da Silva, P.E., Senior Project Manager 2 www.beacon-eng.com 625 Casa Loma Blvd. Suite 106 Boynton Beach, FL 33435 Tel no: 561.424.3270