HomeMy WebLinkAboutFIELD DENSITY TEST REPORT-77-,13 - r
" ANDERSEN ANDRE COnJJLTING ENGINEERS; INC.
834 SW Swan Avenue
Port St. Lucie, Florida 34983
Phone: 772-807-9191 Fax: 772-807-9192
www.aaceinc.com
SCANNED
BY FIELD DENSITY TEST REPORT
L V
PROJECT: Sedona - Phase 1
FILE NO: 17-242
Fort Pierce, Florida RECEIVED
REPORT NO: 39
REPORTED TO: Edwards Landing, LLC JUN 0 6 2018
JPERIVI&O 1T10-0073
ST. Lucie County, Permitting
Culp a
CC: Culpepper & Terpening,Inc.
DATE OF TEST(S): 4/6/2018 PAGE NO.:
1 OF 1
TEST NO.
Multi -Family (T-13) Building (3156 to 3166 Momingdew Lane),
MDR
MOISTURE
DRY
PERCENT
DEPTH
Backfill Around Perimeter of Floor Slab
NO.
CONTENT%
DENSITY
COMPACTION
LOCATION
1
Center of north side of slab
2577
8.7
111.4
99
0 to -1 T GA
2
Center of west side of slab
2577
8.4
111.7
99
0 to -1 T GA
3
Center of south side of slab
2577
9.2
112.0
100
0 to -12" GA
4
Center of east side of slab
2577
8.8
111.7
99
0 to -12" GA
C��
DENOTES IN -PLACE DENSITY TEST DOES NOT MEET MINIMUM COMPACTION REQUIREMENT OF 98 PERCENT.
'• RETEST INDICATED DENSITY MEETS OR EXCEEDS MIN. DENSITY REQUIREMENTS PER SPECIFICATIONS
FIELD TEST: r ASTM D-2937 r ASTM 0-2922 r ASTM D-2167
r ASTM D-1556
TECHNICIAN: KS REMARKS:
LABORATORY MOISTURE -DENSITY RELATIONSHIP
F = SOIL DIRECTLY BELOW FOOTING
FS = FLOOR SLAB SUBGRADE
ASTM MAX. OPTIMUM GA= SOIL IN GENERAL COMPACTED AREA PAV = SOIL BELOW STABILIZED SEC11ON
MDR NO. TEST METHOD DENSITY MOISTURE PSSG= STABILIZED SUBGRADE
PB=PAVEMENT BASE
CONTENT IRS = ROADWAY
NSSG = NON STABILIZED SUBGRADE
2577 D1557 112.5PCF 10.4% SBP = SOIL BELOW PAVEMENT
TOP =TOP OF PIPE
BOP = BOTTOM OF PIPE
BOB = BOTTOM OF STRUCTURE
OTHER:
David P. Andre, P.E.
Fla. Reg. No. 53969
AS A MUTUAL PROTECTION TO CLIENTS. THE PUBLIC AND CURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF CLIENTS AND AUrHORUATION
FOR PUBLICATION OF STATEMENTS. CONCLUSIONS OR EXTRACTS FROM OR REGARDING OUR REPORTS IS RESERVED PENDING OUR WRITTEN APPROVAL.
ANDERSEN ANDRE CONSULTING ENGINEERS, INC.
834 SW Swan Avenue
Port St. Lucie, Florida 34983
Phone: 772-807-9191 Fax:772-807-9192
www.aaceinc.com
FIELD DENSITY TEST REPORT
PROJECT: Sedona - Phase 1 FILE NO: 17-242
RECEIVED
Fort Pierce, Florida
REPORT NO: 26 (REVISED)
MAR 2 S 2019
REPORTED TO: Edwards Landing, LLC PERMIT NO: 1710-0073
ST, Lucie County, Permitting
CC: Culpepper & Terpening, Inc.
DATE OF TEST(S): 3/16/2018 PAGE NO.: 1 OF 1
Multi -Family Building (3156 to 3166 Morningdew Lane), Floor Slab
MDR
MOISTURE
DRY
PERCENT
DEPTH
TEST NO,
and Footing Subgrade
NO.
CONTENT %
DENSITY
COMPACTION
LOCATION
1
e'SE of NW Comer of Slab
2589
10.2
110.3
98
0 to-12" FS
2
12'E and 5'N of SW Corner of Slab
2589
8.7
110.4
98
0 to-12" FS
3
6'NW of SE Corner of Slab
2589
8.9
110.2
97
0 to -12" FS
4
1 O'SW of NE Corner of Slab
2589
8.5
110.4
98
0 to -12" FS
5
5'E of NW Comer of Slab, CL of Footing
2589
10.4
110.7
98
0 to -12" F
6
Center of South Side of Slab, CL of Footing
2589
10.0
110.5
98
0 to -12" F
7
SN of SE Corner of Slab, CL of Footing
2589
9.7
110.8
98
0 to-12" F
8
5'W of NE Corner of Slab, CL of Footing
2589
10.3
110.6
98
0 to -12" F
• DENOTES IN -PLACE DENSITY TEST DOES NOT MEET MINIMUM COMPACTION REQUIREMENT OF 98 PERCENT.
" RETEST INDICATED DENSITY MEETS OR EXCEEDS MIN. DENSITY REQUIREMENTS PER SPECIFICATIONS
FIELDTEST: r ASTM D-2937 I✓ ASTM D-2922 r ASTM D-2167
r ASTM D-1556
TECHNICIAN: KS REMARKS:
LABORATORY MOISTURE -DENSITY RELATIONSHIP
F= SOIL DIRECTLY BELOW FOOTING
FS= FLOOR SLAB SUBGRADE
OPTIMUM
GA= SOIL IN GENERAL COMPACTED AREA
PAV = SOIL BELOW STABILIZED SECTION
MDR NO.
ASTM
MAX.
MOISTURE
PSSG = STABIUZED SUBGRADE
PB=PAVEMENT BASE
TEST METHOD
DENSITY
CONTENT
RS=ROADWAY
NSSG = NON STABILIZED SUBGRADE
2589
D1557
113.1PCF
12.2%
SBP = SOIL BELOW PAVEMENT
TOP =TOP OF PIPE
BOP= BOTTOM OF PIPE
BOS = BOTTOM OF STRUCTURE
OTHER:
David P. Andre, P.E.
Fla. Reg. No. 53969,
AS A MUTUAL PROTECTION TO CLIENTS, THE PUBLIC AND OURSELVES, ALL REPORTSARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF CLIENTS ANDAUrHORIZATION
FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OR REGARDING OUR REPORTS IS RESERVED PENDING OUR WRITTEN APPROVAL
TWA �. �J�4L P `•`
ANDERSEN ANDRE CONSULTING ENGINEERS, INC.
834 SW Swan Avenue
Port St. Lucie, Florida 34983
Phone: 772-807-9191 Fax: 772-807-9192
www.aaceinc.com
FIELD DENSITY TEST REPORT
PROJECT: Sedona - Phase 1
FILE NO: 17-242
Fort Pierce, Florida
RECEIVED
REPORT NO: 26.A
REPORTED TO: Edwards Landing, LLC
PERMIT NO: 1710-0073
MAR 2 S 2018
CC: Culpepper & Terpening, Inc.
ST. Lucie County, P6rmltNng
DATE OF TEST(S): 3/28/2018
PAGE NO.: 1
OF 1
TEST NO.
Multi -Family Building (3156 to 3166 Morningdew Lane), Floor Slab
and Footing Subgrade
MDR
NO.
MOISTURE
CONTENT%
DRY
DENSITY
PERCENT
COMPACTION
DEPTH
LOCATION
1
6'NW of SE Corner of Slab (Retest from 3/16118)
2589
9.0
111.2
98
0 to -12" FS
` DENOTES IN -PLACE DENSITY TEST DOES NOT MEET MINIMUM COMPACTION REQUIREMENT OF 98 PERCENT.
•• RETEST INDICATED DENSITY MEETS OR EXCEEDS MIN. DENSITY REQUIREMENTS PER SPECIFICATIONS
FIELD TEST: r ASTM D-2937 r ASTM D-2922 r- ASTM D-2167
r ASTM D-1556
TECHNICIAN: KS
REMARKS:
LABORATORY MOISTURE -DENSITY RELATIONSHIP
F = SOIL DIRECTLY BELOW FOOTING
FS = FLOOR SLAB SUBGRADE
OPTIMUM
MDR NO. ASTM MOISTURE
TEST METHOD DENSITY CONTENT
GA= SOIL IN GENERAL COMPACTED AREA
PSSG= STABILIZED SUBGRADE
IRS =ROADWAY
PAV = SOIL BELOW STABILIZED SECTION
PS=PAVEMENT BASE
NSSG= NON STABILIZED SUBGRADE
2589 D1557 113.1 PCF 12.2 %
SEP = SOIL BELOW PAVEMENT
TOP =TOP OF PIPE
BOP= BOTTOM OF PIPE
BOS = BOTTOM OF STRUCTURE
OTHER:
David P. Andre, P.E.
Fla. Reg: No. 53969
AS A MUTUAL PROTECTION TO CLIENTS, THE PUBUC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF CLIENTS AND AUTHORIZATION
FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OR REGARDING OUR REPORTS IS RESERVED PENDING OUR WRITTEN APPROVAL:
£, 1 �• #IDS(, 4.
7-<3
ANDERSEN ANDRE Car.sULTING ENGINEERS, INC.
FIELD DENSITY TEST REPORT
834 SW Swan Avenue
Port St. Lucie, Florida 34983
Phone: 772-807-9191 Fax: 772-807.9192
www.aaceinc.com
PROJECT: Sedona - Phase 1
FILE NO: 17-242
Fort Pierce, Florida
RECEIVED REPORT NO: 39
REPORTED TO: Edwards Landing, LLC
APR 13 2018
NO: 1r.1__OA_7,3
CC: Culpepper & Terpening, Inc.
ST. Lucie County, Permitting
DATE OF TESTIS): 4/6/2018
PAGE NO.:
1 OF 1
TEST NO.
Multi -Family (T-13) Building (3166 to 3166 Morningdew Lane),
Backfill Around Perimeter of Floor Slab
MDR
NO.
MOISTURE
CONTENT%
DRY
DENSITY
PERCENT
COMPACTION
DEPTH
LOCATION
1
Center of north side of slab
2577
8.7
111.4
99
0 to -12" GA
2
Center of west side of slab
2577
8.4
111.7
99
0 to -12" GA
3
Center of south side of slab
2577
9.2
112.0
100
0 to -12" GA
4
Center of east side of slab
2577
8.8
111.7
99
0 to -12" GA
IL
' DENOTES IN -PLACE DENSITY TEST DOES NOT MEET MINIMUM COMPACTION REQUIREMENT OF 98 PERCENT.
" RETEST INDICATED DENSITY MEETS OR EXCEEDS MIN. DENSITY REQUIREMENTS
PER SPECIFICATIONS
FIELD TEST: r A.STM D-2937 i✓ ASTM D-2922 r ASTM D-2167
r ASTM D-1556
TECHNICIAN: KS
REMARKS:
LABORATORY MOISTURE -DENSITY RELATIONSHIP
F = SOIL DIRECTLY BELOW FOOTING
FS = FLOOR SLAB SUBGRADE
ASTM MAX. OPTIMUM
MDR NO. TESTMETHOD DENSITY MOISTURE
CONTENT
GA= SOIL IN GENERAL COMPACTEDAREA PAV = SOIL BELOW STABILIZED SECTION
PSSG= STABILIZED SUBGRADE PB=PAVEMENT BASE
IRS =ROADWAY NSSG = NON STABILIZED SUBGRADE
2577 D1557 112.5PCF 10.4%
SEP= SOIL BELOW PAVEMENT
TOP =TOP OF PIPE
BOP = BOTTOM OF PIPE
BOS = BOTTOM OF STRUCTURE
OTHER:
-David P. Andre, P.E.
Fla. Reg. No. 53969
ASA MUTUAL PROTECTION TO CLIENTS, THE PUBLIC AND OURSELVES, ALL REPORTS ARE SUBMITTED AS THE CONFIDENTIAL PROPERTY OF CLIENTS AND AUTHORRATION
FOR PUBLICATION OF STATEMENTS, CONCLUSIONS OR EXTRACTS FROM OR REGARDING OUR REPORTS IS RESERVED PENDING OUR WRITTEN APPROVAL
`5
ANDERSEN ANDRE CONSULTING ENGINEERS, INC.
Port St.
4983
9192
IFLI L LI Phone: 771 607 919 1W Swan Avenue
L Fww.aacei cie, Florida .com
FIELD DENSITY TEST REPORT br.2Vr�
11 �� aa13 _
PROJECT: Sedona - Phase 1
Fort Pierce, Florida
L='!-b'!4!Itting
REPORTED TO: Edwards Landing, LLC
PERMIT NO: 1710.0073
CC: Culpepper & Terpening, Inc.
-
DATE OF TEST(S): 3/16/2018
PAGE NO.: 1
OF 1
TEST NO.
Multi.Famlty Building (3156 to 3166 Momingdew Lane), Floor Slab
MDR
MOISTURE
DRY
PERCENT
DEPTH
and Footing Subgrade
NO.
CONTENT %
DENSITY
COMPACTION
LOCATION
1
e'SEofNWComerof Slab
2589
10.2
110.3
98
0to-12"FS
2
12'E and VN of SW Comer of Slab
2589
8.7
110.4
88
0 to -12" FS
3
e'NW of SE CDmerof Slab
2589
8.9
110.2
9
0to-12"FS
4
10'SW of NE Comerof Slab
2589
8.6
110A
08
Oto-12"FS
5
5'E of NW Comer of Slab, CL Of FooUng
2589
10.4
110.7
96
0 to -12" F
6
Center of South Side of Slab. CL of Footing
2589
10.0
110.5
98
0 to -1P" F
7
5'N of SE Comer of Slab, CL of Footing
2589
9.7
110.8
96
0 to -12" F
8
5'W of NE Comer of Slab, CL of Footing
2589
10.3
110.8
98
0 to -02' F
• DENOTES IN -PLACE DENSITY TEST DOES NOT MEET MINIMUM COMPACTION REQUIREMENT OF 95 PERCENT.
•• RETEST INDICATED DENSITY MEETS OR EXCEEDS MIN. DENSITY REQUIREMENTS PER SPECIFICATIONS
FIELD TEST: F'" ASTM D-2937 F ASTM D-2922 r ASTM D-2167 r ASTM D-1556
TECHNICIAN: KS
REMARKS:
LABORATORY MOISTURE -DENSITY RELATIONSHIP
F = SOIL DIRECTLY BELOW FOOTING
FS = FLOOR SLAB SUBGRADE
OPTIMUM
GA= SOIL IN GENERAL COMPACTED AREA
PAV=SOIL BELOW STABILIZED SECTION
ASTM MAX
MDR No. MOISTURE
PSSG=STABILQEDSUBGRADE
PB=PAVEMENTBASE
TEST ETHOD DENSITY
CONTENT
RS=ROADWAY
NSSG = NON STABI17EDSLBGRADE
2589 D1557 113.1PCF 12.2%
SBP= SOIL BELOrYPAVEMENT TOP =TOP OF PIPE
BOP=BOTTOM OF PIPE
BOS = BOTTOM OF STRUCTURE
OTHER:
ST. LUCIE COUNTY BU$DEd6 HMS ON
Pre•Revle►ved Not 1n Compliance ^,
Revielved By, David P. Andre, FW.
Date: Q Fla Reg. No. 53011
ARA kATrUALPROTECTION TO CLIENTe,THE PifEMAND OURSELVES, ALL REPOMARE SUSMr EO AST WO OENM PROPERTYOFCLIENT'
FOR W3U=ONOFSTAT ENTS,CONCLUSIONSORMRACT8 FRONORREOMORt000RRE'ORM[S RESERVED PENDING OUR Wf(I�i
�D P. ANON///i
No 53969 '.
RSeTA13iE OF %/4�,'
'i
�ONA`t 0� �\\�
AwijERSEN ANDRE CONSULTING ENGINEERS, INC.
834 SW Swan Avenue
Port St. Lucie, Florida 34983
Phone:772-807-9191 Fax:772-807-9192
www.aaceinc.com
MOISTURE -DENSITY RELATIONSHIPS
PROJECT: Sedona PUD Phase 1 FILE NO: 17-242
Fort Pierce, St. Lucie County REPORT NO: 6
REPORTED TO: Edwards Landing, LLC
PERMIT NO:
CC: Culpepper & Terpening
■■■■■■■■■■■■■■���■■■■■■■
,
■■■■■■■■■■■■M■■■■U
M■■■■
OPTIMUM WATER
■■■■■■■■■■■■■■■■■■■WIN■■-
■■■■■■■■■■■■■■■■■■■■■
01
■■■■■■■■■■■■■■■■■■■■■■��■■■■■■■■■■■
■■■■■■■■■■■■■■■■■■■■■■■EMM■■■■■■
■■■■■■■■■■■■■■■■■■■■■■■■■■■■\\\\■■■■
■■■■■■■■■■■■■■■■■■■■■■■■■■■■■■\\■■■
.
SAMPLE NO:
DESCRIPTION:
DATE SAMPLED:
DATE TESTED:
ek-1:1;:]
3/16/2018
11/15/1900
SAMPLE LOCATION: Composite of Pad Fill 3156-3166 Momin dew Ln.
fine sand
BY: KS
BY: SM
�ON'.AmERS-
- .``
Peter G. Mdew
Fla. Reg. ft 5;g9t6 : •'
13 ; STATE OF
EDPENDING PROPERTY
OUROF DAUTHORRATION
W'FgbR10P •0
��V//.S1ONA1.