HomeMy WebLinkAboutMISC EMAILd
PAUL WELCH INC.
4: Mechanical * Electrical * Civil Engineering
1984 S.W. Biltmore St. Suite#114
Port Saint Lucie, FL 34984
Phone (772) 785 - 9888
Email pwelchinc@aol.com
a
r�F�
October 31, 2017
SCANNED
Re: Shutter Installation BY
9600 S. Ocean Dr. (#1201)St. Lucie County
Jensen Beach, FL
To Whom It May Concern:
Our office has calculated the required design pressures in accordance with ASCE 7-10
and Florida Building Code 2014 for the installation of shutters at the above referenced
address.
Wind speed: V Ic: 165 mph, Vim: 128 mph
Exposure: D
Enclosure Type: Enclosed
Shutter Size: 96.5" Maximum Height
Shutter Location: Covered Porch (See Attached Sketch)
Required Design Pressure: +45.6/ -59.0 PSF
Shutters to be installed shall be equal to, or exceed the required design pressures as listed
above "Required Design Pressure".
Shutters shall be installed in accordance with the shutter manufacturer's installation
instructions and Florida Product Approval and Florida Building Code 2014.
Shutters shall be FL# 1850.2
Thank you for your attention to this matter.
Submitted by:
LTL WELCH INC.
P 1 Welch, P.E.
Reg. No 29945
/1— G
ST. LUCIE COUNTY
BUILDING DIVISION
REVIEWED
FOR COM 1 NOR
REVIEWED BY
DATE
-PLANS AND PERMIT
MUST BE KEPT ON JOB OR
NO INSPECTION WILL BE MADE