Loading...
HomeMy WebLinkAboutMISC EMAILd PAUL WELCH INC. 4: Mechanical * Electrical * Civil Engineering 1984 S.W. Biltmore St. Suite#114 Port Saint Lucie, FL 34984 Phone (772) 785 - 9888 Email pwelchinc@aol.com a r�F� October 31, 2017 SCANNED Re: Shutter Installation BY 9600 S. Ocean Dr. (#1201)St. Lucie County Jensen Beach, FL To Whom It May Concern: Our office has calculated the required design pressures in accordance with ASCE 7-10 and Florida Building Code 2014 for the installation of shutters at the above referenced address. Wind speed: V Ic: 165 mph, Vim: 128 mph Exposure: D Enclosure Type: Enclosed Shutter Size: 96.5" Maximum Height Shutter Location: Covered Porch (See Attached Sketch) Required Design Pressure: +45.6/ -59.0 PSF Shutters to be installed shall be equal to, or exceed the required design pressures as listed above "Required Design Pressure". Shutters shall be installed in accordance with the shutter manufacturer's installation instructions and Florida Product Approval and Florida Building Code 2014. Shutters shall be FL# 1850.2 Thank you for your attention to this matter. Submitted by: LTL WELCH INC. P 1 Welch, P.E. Reg. No 29945 /1— G ST. LUCIE COUNTY BUILDING DIVISION REVIEWED FOR COM 1 NOR REVIEWED BY DATE -PLANS AND PERMIT MUST BE KEPT ON JOB OR NO INSPECTION WILL BE MADE