Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed
the Evaluation Report
Florida Ucense
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
Revision
2014
Approved
GAF
1 Campus Drive
Parisppany, NJ 07054
(800) 766-3411
mstieh@gaf.com
Robert Nieminen
lindarelth@trinityerd.com
William Broussard
1 Campus Drive L
Parsippany, NJ 07054
(800) 766-3411
TechnicalQuestionsGAF@gaf.com
Roofing
Single Ply Roof Systems
ST. LUCIE COUNTY
BUILDING DIVISION
REVIEWED
FOR COMPI
REVIEWED BY
MUST BE KEPT ONOOB OR
NO INSPECTION WILL BE MADE
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
❑ Evaluation Report - Hardcopy Received
Robert Nieminen
PE-59166
UL LLC
10/18/2018
John W. Knezevich, PE
G Validation Checklist— Hardcopy Received
FL16730 R13 QQI 2017 01 CQI Nieminen odf
Standard Vear
TAS 110 2000
TAS 114 2011
TAS 131 1995
THESE PLANS AND ALL PROPOSED WORIC
ARE SUBJECT TO ANY CORRECTIONS
REQUIRED BY FIELD INSPECTORS THAN
FRAY BE NECESSARY IN ORD2R TO
COMPLY WITH AIL APPLICABLE CODES.
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqu8obld/d2flZm... 11 /20/2017
r Florida Building Code Online
Page 2 of 2
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Date Revised
Summary of Products
Method 1 Option D
t: t >�
1' t C' 1 L i`a,11] ads.
10/10/2017
10/17/2017
FL #
Model, Number or Name
Description
16730.1
EverGuard TPO Single Ply Roof
Thermoplastic polyolefiin single ply roof systems
Systems
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL16730 R13 If 2017 OB FINAL Al ER GAF EG
TPO HVHZ FL16730-R13.odf
Approved for use outside HVHZ: No
Impact Resistant: N/A
Verified By: Robert Nieminen PE-59166
Design Pressure: +N/A/-502.5
Created by Independent Third Party: Yes
Other: 1.) The design pressure herein pertains to one
Evaluation Reports
system. Refer to ER Appendix for all systems and maximum
EL16730 R13 AE 2017 OB FINAL ER GAF EG
design pressures. 2.) Refer to ER Section 5 for Limits of Use.
TPO HVHZ_ FL16730-1113.0df
Created by Independent Third Party: Yes
BaU Nert
Contact Us :: 2601 Blair Stone Road, Tallahassee R 32399 Phone: 850-487-1824
The state of Florida is an AA/EM employer. Coovrloht 2007-2013 State of Florida.:: Privacy statement :: Accessibility Statement :: Refund Statement
ader Florida law, email addresses are public records. If you do not want your a -mall address released In response to a public -records request, do not set
an email address which can be made
Chapter 455, F.s., please click bdi
Product Approval Accepts:
® ®--.t6,k E
"'secu'ityramt1c5-
11 addresses are public record. If you do not wish to
to the public. To determine if you are a licensee under
rARESu �CT7DALL pROpOSr:DWORf�
R=QurR_0 OANYCOF?AECi oPlg
MAY f3 j , ESSA rhrSpECTOr S THAT
COra,pLY S 1THpJSAI�YItA OpD2r TO
A,�FLFCAj;LE CODES.
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqu8obld/o2ffZm... 11 /20/2017
Drawing Report
Indrio Crossings - Alternate Bid I - Reroof GAF TPO 8/18/17
section: Entire Job
Page: Roof B
21'0- N9 33-e
y` ]... a
-WO - -
IN iL
W.,; I MW
8/25/2017 Page 1
Tecta America South Florida 1431 SW 30th Avenue Deerfield Beach Florida Phone: 954 419-9339 Fax: 954419-9336
Florida Building Code Sth Edition (2024) .
High-VelocityHurricane Zone Uniform Permit Application Form
Section. C (Low Siooed Roof Svstem)
FIB in Speeliic'Roof Assembly Components
and Identify 1Nanufedtuer
(Ua oompanent lariat used, idenQfy'as "NAB . .
system Matar18cw.. GAF
une u�. FL16730-R12 •
Design Wind Pmmur , From RAS 128 or Celcolatiom:'
'Prnaxl• -37.80 PMOX2..63A2 . PIIIBX Li 5.45 .
Max. Design Pm%m.Fr=theSpoeflcNOA
.System:
Deck.
TOW- LWIC over Sheet
gam:' 1/40/ft min
AnchodBase Sheet R Na of Ply(s): NA
Andhor/6assSheet Fe dgorldingMateriak
NA
ImWetbn Base Layer —AL —
Bass insifisigon Sim and Thiclotess, NA
Base lnmffr Fastenerf for ding Malachi:
Top Imdetlell Layer Dens Deck
Top Insulation Sim and TNcm"r 4x4x1/2
Top ImulaWn Fastenedeonding Materiel:
#15 Fastener
Base Sheel(e) 6 No. of py(s):NA
Base Shoat FastenedBw&V Material:
NA
Fastener Spadng for AnehodBase Shag
Afftehm®M See Engineering
114" "sheet width .
Field: 8 'cc@Lop, 0Rowioc
35" sheet width
Perimeter. 12-oo@Lsp;#Rorva_&^ cc
35" sheet width
Comer 12 -..oc@Lep.#Rbm — —@_ cc
Numbec of Finteneis Per IniuleBon
Board Preliminary Fastened.
4 fasteners per 4x8 board
Field = Perfinetsr '_Comer
Illustrate Components Noted and,
Dstalls es Appilcable:_
Woodblocking. Gutter... Edge - Termination;
Stripping, Flashing. Continuous C(eat._ Cent
Strip, Base Flashing, :Counter Flashing,
Coping, Eta
Indicate: Mean Roof Height, Parapet Height;
Height of Base Flashing, Component Material,
Materiel Thicimess, Fastener Type, Fastener.
Sparing or Submit Manufacturers.Details that
Comply with RAS 111 and Chu .
24ga coping fastened t2' oc .I
w/ #lo fastenem
22ga cleat fastened w/
12ga annular roofing nails 4' oc
Top Ply 8
Insulation
PlyStherlt(e)& No. of Ply(s); NA r
Pysti rxrBondlingl terial: New Gutter & D
.. Spout.: See Detail
Toppiy:.GAF 60 Mil TPO
Fr. Sri
Parapet
Helom
Fr. 151
Mean
'Top PlyFaste rondUvMaterlal:
#F15 rastener.. .
smtecdng• NA
— LE 006PT
/a TECTAAMERICA
South Florida, Inc.
Florida Product Approval
Tecta America South Florida Inc. 11431 SW 30th Avenue, Deerfield Beach, FI.33442 1 T: 954.419.9339 F: 954.419.9337 I tectaamerica.com
Exterior Research and Design, LLC. d/b/a7dnity( ERD
CertiRcate of Authorization 09503
Prepared by: Robert Nleminen, PE-59166
Revislon
FBCHVHZ EVALUA71ON PIyep.rt01506.12•lL LEt, Appendi 13:0216/2017
GAF; (800)766.3411
The following notes apply to the systems outlined herein:
RNTY I ERD
1. The evaluation herein pertains to above -deck roof components; deck -attachment details pertain to'as-tested' conditions under TAS 114, Appendix J. Roof decks shall be in accordance with FBC (HVHZ) requirements
to the satisfaction of the AH1.
2. Unless otherwise noted, fasteners and stress plates for insulation or base sheet attachment shall be as follows. Fasteners shall be of sufficient length for the following engagements:
D Wood Deck: Drill-Tec a12 Fastener or Drill -Tee $114 Fastener with Drill-Tec 3" Standard Steel Plate, Drill-Tec 3" Steel Plate, Drill-Tec 3In. Ribbed Galvalume Plate (Flat) or Drill-Tec AccuTrac Flat Bottom
Plate or Drill-Tec AccuTrac Recessed Plate (insulation only), Drill-Tec ASAP 3S or Drill-Tec Heavy Duty ASAP 3S. Min. 0.75-Inch plywood penetration or minimum 1-Inch wood plank
embedment.
D Steel Deck: Drill-Tec 012 Fastener, Drill-Tec h14 Fastener or Drill-Tec XHD Fastener with Drill-Tec 3" Standard Steel Plate, Drill-Tec 3" Steel Plate, Drill-Tec 3 In. Ribbed Galvalume Plate (Flat) or Drill-
Tec AccuTrac Flat Bottom Plate or Drill-Tec AccuTrac Recessed Plate (Insulation only). Minimum 0.75-Inch steel penetration, engage the top flute of the steel deck.
D Structural concrete: Drill-Tec 914 Fastener or Drill-Tec CD-10 with Drill-Tec 3" Standard Steel'Plate; Drill-Tec 3" Steel Plate, Drill-Tec 3 In. Ribbed Galvalume Plate (Flat) or Drill-Tec AccuTrac Flat Bottom Plate
or Drill-Tec AccuTrac Recessed Plate (insulation only) or.Drill-Tec Heavy Duty ASAP 3S. Minimum 1.25-Inch embedment. Fasteners Installed with a pilot hole in accordance with the
fastener manufacturers published Installation Instructions.
3. Unless otherwise noted, insulation may be any one layer or combination of polyisocyanurate, polystyrene, wood fiberboard, perlite, gypsum -based roof board or mineral wool roof board that meets the CIA
requirements of F.A.C. Rule 61G20-3.and Is documented as meeting FBC (HVHZ)1516 and, for foam plastic, FBC Chapter 26, when installed with the roof cover.
Refer to GAF published Installation instructions for details and requirements regarding the use of FBC HVHZ approved polystyrene Insulation In EverGuard® roofing systems:
Insulation: Hleh Traffic Applications: Recover Applications:
D FBC HVHZ approved Expaned polystyrene (EPS) meeting or D FBC HVHZ approved Extruded polystyrene (XPS) meeting or D FBC'HVHZ approved XPS Fan -Fold Recover Board with plastic
exceeding TAS 110 and ASTM C578, Type IX, nominal 1.8 Ib/112 exceeding TAS 110 and ASTM C578, Type IV, minimum 1-inch facer meeting or exceeding TAS 110 and ASTM C578, Type IV,
density and minimum 25 psi compressive strength. thick and minimum 25 psi compressive strength. 3/8-Inch thick and minimum 25 psi compressive strength.
➢ FBC HVHZ approved Expanded polystyrene (EPS) with plastic D FBC HVHZ approved Expanded polystyrene (EPS) with plastic D FBC HVHZ approved EPS Recover Board meeting or exceeding
facer meeting or exceeding TAS 110 and ASTM C578, Type IX, facer meeting or exceeding TAS 110 and ASTM C578, Type IX, TAS 110 and ASTM C578, Type IX, 1/2-Inch thick and minimum 25
nominal 1.8 Ib/ft2 density and minimum 25 psi compressive minimum 1-Inch thick and minimum 25 psi compressive strength. psi compressive strength.
strength.
D FBC HVHZ approved EPS Recover Board with plastic facer
meeting or exceeding TAS 110 and ASTM C578, Type IX, 1/2-Inch
I tck and minimum 25TOPCOAT- FlreOut— Fire Barrier Coating, VersaShleld- Fire -Resistant Roof Deck Protection or VersaShleld- Solo"' Fire -Resistant Slip Sheet, Installed In accordance with GAF pulbllshed Installation instructions and fire
resistance certification listings, may be used as a non -load -bearing, fire -barrier / slip -sheet component within any system outlined herein.
4. If mechanical attachment to the structural deck through lightweight Insulating concrete is proposed, field withdrawal resistance testing shall be performed to confirm equivalent or determine enhanced fastening
patterns and density. All testing and fastening design shall be In compliance with Testing Application Standard TAS 105 and Roofing Application Standard RAS 117 and/or RAS 137. Calculations shall be prepared,
signed and sealed by a qualified design professional.
S. Preliminary Insulation attachment for System Type CG2 and D= Minimum four fasteners per 4 x 8 ftboard or minimum two fasteners per 4 x 4 H board.
6. Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted In the manufacturer's published instructions.
D Hot Asphalt (HA): Full mopping, 25-30lbs/square.
D GAF 2-Part Roofing Adhesive (GAF 2-Part): Continuous 2.5 to 3.5-Inch ribbons,12-Inch o.c.
➢ LRF Adhesive M (LRF-M): Continuous 0.75 to 1-Inch wide ribbons,12-Inch o.c.
D OlyBond Adhesive Fastener (Classic): Full coverage, I gal/square.
➢ OlyBond 500(OB500): Continuous 0.75 to 1-Inch wide ribbons,l2-Inch o.c. using PaceCart or SpotShot.,Note: OlyBond Classic or O/yBond 500 Green may be used In place ofOB500.
D Note: When multipleloyers(s) of insulation and/orcoverboard are Installed in ribbonr
D Note: The maximum edge distance from the adhesive ribbon to the edge of the applied adhesive, boardjolnts shall be staggered
Insulation board shall benot less than one-half the specified ribbons spacing.
7. Unless otherwise noted, all insulations are flat stock or taper board of the minimum thickness noted. Tapered polylsocyanurate at the following thickness limitations may be substituted with the following Maximum
Design Pressure (MDP) limitations. In no use shalLthese values be used to 'Increase' the MDP listings In the tables; rather if MDP listing below meets or exceeds that listed for a particular system In the tables, then
the thinner board listed below may be used as a drop -in for the equivalent thicker material. listed in the table.
Exterior Research and Design, U.C. d/b/a Trinity ERD
Certificate of Authorization 719503' FBC L
E ///��,,, T'�tR art OSS06.12.13-1-R33 for FL1673p-R12
Prepared by: Robert Nleminen, PE-593fifi HVHZ EVAWATIO�
GAF: (800) 7663411 Revlslon 13:02/16/2017
Appendix 1, Page 2 of 94
D Hot Asphalt (HA): _171 IBIS IIII , 6 I ERD
➢ GAF 2-Part Roofing Adhesive (GAF 2-Part): MDP = 1.5 psf (Min. 0.5-Inch thick) `�4'17.5 psf (MIn.1.0-Inch thick)
D LRF Adhesive M (LRF-M): MDP = -2325 psf (Min. 0.5-Inch thick EnergyGuard Pol iso Insulation, EnergyGuard BY Y NH Polylso Insulation, EnergyGuard UI[m Polylso Insulation,
D 01 y ( ) Bond 500 OB500; EnergyGuard Ultra Polyiso Insulation)
MOP 3thick psf (Min. thick EnergyGuard RH or RN)
D OlyBond 500(OB500): MDP =-487.5 psf (MIn.0.5-Inch thick EnergyGuard RA)
➢ OlyBond Soo(OB500): MDP= -292.5 psf (Min. 0.5-inch thick EnergyGuard Polyiso Insulation, EnergyGuard NH Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation,
EnergyGuard NH Ultra Polyiso Insulation)
8. Bonded polyisocyanumte Insulation boards shall be maximum 4 x 4 ft.
9. Perimeter and comer areas shall. comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be Increased, as calculated in compliance with Roofing Application Standard RAS 117
and/or RAS 137bya qualified design professlonal. "This extrapolation Is notpermlttedfarsystems marked with an asterisk*.
10. For assemblies marked with an asterisk-, the maximum design pressure (MDP) limitation, listed shall be applicable to all roof pressure zones (i.e., field, perimeters and corners). Neither rational analysis, nor
extrapolation is permitted far enhanced attachment at enhanced pressure zones (I.e., perimeters, corners and extended corners). -
11. Fastener spacing for mechanical attachment Is based an a minimum fastener resistance value In conjunction with the maximum design pressure (MDP) listed for a specific system. Should the fastener resistance be
less than that required, as determined by the Building Official, a revised fastener spacing —prepared, signed and sealed by a qualified design professlonal-may be.submltted. Said revised fastener spacing shall utilize
the withdrawal resistance value taken from Testing Application Standard TAS 105 and calculations In compliance with Roofing Application Standard RAS 117 or RAS 137.
12. For bonded Insulation or membrane over existing substrates in recover Installation, the existing roof system shall be capable of resisting project design pressures on Its own merit to the satisfaction of the AHJ, as
documented through field uplift testing in accordance with TAS 124.
13._ For System Type D, steel deck applications, the roof membrane shall be run with Its length perpendlcularto the steel deck Flutes.
14. For recover Installations, the existing roof shall be examined in accordance with FBC 1522. For Recover Applications using System Type C-2 or or any System Type D, the insulation is optional. Alternatively, a
separator board may be installed priorto roof cover Installation when using System Type C-2 or any5ystem Type D or a separator sheet maybe installed priorto roof cover installationwhen using any System Type D.
The separator component shall be documented as meeting FBC (HVHZ)1516 and, for foam Plastic, FBC Chapter 26, when Installed with the roof cover In Recover applications. .
➢ Separator Board Options for Recover System Type C 2 or System Type D Min. 05-Inch EnergyGuard Polyiso Insulation, EnergyGuard NH Polylso Insulation, EnergyGuard RA, EnergyGuard RN, EnergyGuard Ultra
Polyiso Insulation, EnergyGuard NH Ultra Polyiso Insulation, Structodeck High Density Fiberboard Roof Insulation, EnergyGuard RH HD Polyiso Insulation, EnergyGuard HD Polyiso Insulation, EnergyGuard NH HD
Polyiso Insulation, EnergyGuard HD Plus Polyiso Insulation or EnergyGuard NH HD Plus Polylso Insulation or min. 0.25-Inch Dens Deck, Dens Deck Prime, SECUROCK Gypsum•Fiber Roof Board or SECUROCK Glass.
Mat Roof Board.
D Separator Sheet Options for Recover System Type D EverGuard Polymat Se pa ration Layer (3 oz/yd') or EverGuard Polymat Cushioning Layer(6 oz/yd').
15. For systems where specific lightweight insulating concrete (LWIC) Is referenced, refer to current LWIC Product Approvalforspecific deck construction and limitations. Unless otherwise noted, for systems where
specific LWIC is not referenced, the minimum design mix shall be 300 psi.
16. Side laps for EverGuard Freedom TPO with RapldSeam Technology are self -adhering. Side laps for EverGuard Freedom TPO HW are heat welded. Unless otherwise noted, reference to EverGuard Freedom TPO In this
Appendix relates to either method.
1
Exterior Research and Design, LLO d/b/a Trinity( ERD
Certificate of RobertRobert Authorization a9503 Evaluation Report 01506.12.13.1-R13 for FL167MFL12
Prepared by: Nieminen, PE-59166 FBC HVHZ EVALUATION
GAF; (800) 766-3411 Revislon 13: 02/16/2017
Appendix 1, Page 3 of 84
17.
TRINITY Eft®
For adhesive -applied membrane systems, side laps shall be minimum 3-Inch wide
Membrane -Adhesive.
1
sealed with min. 1.5-Inch heat weld. Unless otherwise noted, membrane adhesive application
-
• - -
',Method `
rates are as follows:
Rate: ..
EverGuard TPO
EverGuard TPO 91121 Bonding Adhesive
(#1121)
Contact (both sides)
0.8 to 1.0 gal/square/surface.: For use over SECUROCK G Board, the appllcatlon
Gypsum -Fiber Roof
rate
.changes to 1.2 to L6Z gal/sq/surface.
EverGuard TPO
EverGuard WB181 Bonding Adhesive (WB381)
Contact (both sides)
Insulation, �HDI
TOOfTo
at 0.63 gal/square and roof cover underssiide ensity at
.21 gal/square.Fiberboard
Dens DeckbPrimesor SECUROCKGypsum-
EverGuard
TPO
EverGuard TPO
EverGuard TPO FB Ultra
EverGuard TPO FB Ultra
EverGuard TPO FB Ultra
EverGuard TPO FB Ultra
Bonding Adhesive (L-
Contact(both sides) 0.46 gal/square/surface
Low VOCBonding Contact (both sides) 0.84 gal/square/surface
GAF LRF Adhesive M (LRF-M) or LRFAdhesive 1-Inch wide ribbons spaced as noted In tables herein. Note: The adhesive ribbons are located directly over
O F LRF) Wet lay (substrate) the adhesive ribbons used to secure the insulation when the cover is bonded to Insulation less than 1.5-Inch
thick.
18. The "Triposite Roofing System" notedherein consists of loose -laid GAFGLAS Stratavent Perforated Venting Base Sheet, followed by asphalt -applied two 12) plies of Ruberoid 20 Smooth or three (3) plies of GAF
FlesPly 6, followed by asphalt-applled 80-mil EverGuard TPO FBUltrawith 1-5/8" heat welded side laps. GLAS
19. Unless otherwise noted, the "Hybrid Roofing System" noted herein consist, of asphalt-applledRuberoid 20 Smooth, Ruberold Mop Smooth, Ruberoid Mop Smooth 1.5, GAFGLAS #75 Base Sheet, Tri-Ply#75 Base
Sheet or GAFGLAS 480 Ultima Base Sheet followed by asphalt -applied EverGuard TPO FB Ultra.
20. EverGuard Extreme TPO may be used as an alternate to EverGuard TPO. EverGuard Extreme TPO FB Ultra may be used as an alternate to EverGuard TPO FB Ultra.
21 Th fof 1
e owing Insulations are interchangeable within the scope of this Evaluation Report:
D
EnergyGuard Polyiso Insulation
D
EnergyGuard NH Polyiso Insulation;
EnergyGuard Ultra Polyiso Insulation a
➢
EnergyGuard NH Ultra Polyiso Insulation;
EnergyGuard HD Polyiso Insulation a
D
EnergyGuard NH HD Polyiso Insulation;
EnergyGuard HD Plus Polyiso Insulation Kb
EnergyGuard NH HD Plus Polyiso Insulation.
Exterior Research and Design, I.I.C. d/b/a Trinity) ERD
Certificate of Authorization #9503 FBC HVHZ EVALVATION Evaluation Report 01506.12.13-1-R13 for FL36730-R32
Prepared by: Robert Nieminen; PE-59166 GAP, (800) 766-3411 Revlslon 13:02/16/2017
Appendix 1, Page 4 of 84
QA RINI 1 1 I ERD
22. Vapor barrier options for over structural toot
VAPORBARRIER OPTIONS; STRUOTUpALCONCRETE'DECK; ADHERED INSULATION PER,TABLES SA-IAND.3A'2'g Ilfnitatlo05 The lesser ofthe MDP listings below vs. those In Table 3Aa 1plles:
concrete deck with adhered insulation car the following Maximum Design Pressure (MDP) ` -
Option # Primer Vapor Barrier
a Attach Insulation Adhesive MOP (psf)
1 Matrix 307 Premium Asphalt Primer or ASTM D41 primer One Or two plies, GAFGLAS #75 Base Sheet, Tri-Ply#75 Base
2Sheet GAFGLAS PI 4, Tri-PI PI 4 or GAFGGLAS FIexPI 6 Hot asphalt applied Hot asphalt
A Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid Torch GR _ __ _ -360.0
..... _._. ��-„��w Aneer
2D Matrix 307 Premium Asphalt Primer or ASTM D41 One or two plies, GAFGLAS #75 Base Sheet, Trl-Ply#75Base
self -adhering-.
_-.-_..._..-...
GAF 2-Part, 12-Inch o.c.
_10u.0
-250.0
-
primer
SheW.et,
2E Matrfz 307-0remium As halt Primer or ASTM D4l Gd30� Ply 4, Trl-Ply Ply 4 or GAFGGLAS FIexPI 6
Hot asphalt applied
a
GAF 2-Part, 12-Inch O.C.
-262S
primer
3A Matrix 307 Premium As halt Primer or ASTM D41 primer Ruberoid HW 25 Smooth or Ruberoid HW Smooth
Hot as halts lied
GAF 2-Part,12•Inch o.c.
-270.0
3B Matrix 307 Premium Asphalt Primer or ASTM D41 primer One or two plies, GAFGLAS #75 Base Sheep Trl-Ply 075 Base
Torch•a Iled
iRF-M 12•Inch o.c.
180.0
Sheet, GAFGLAS Ply 4, Tri-Ply Ply 4 or GAFGGLAS FlexPly 6
4A Matrix 307 Premium Asphalt Primer or ASTM D41
Hot asphalt applied
LRF-M,12-inch o.c.
-495.0
rimer UnderRoof 2 Pol ester -Surfaced Leak Barrier
48 Matrix 307 Premium As halt Primer or ASTM D41 primer Ruberold Torch SmoothSelf-adherin
01 Bond 500, 12-Inch o.c.
4C Matrix 307 Premium Asphalt Primer or ASTM D41 primer. Ruberoid HW 25 Smooth
Torch -applied
OlyBond 500, 12-Inch o.c.
-1275
-165.0
4D Matrix 307 Premium Asphalt Primer or ASTM D41 primer Ruberoid 20 Smooth
Torch -a Iled Matriz 102 SBS Membrane
01 Band 500, 12-inch o.c.
-180.0
-
4B Matrix 307 Premlum Asphalt Primer or ASTM D41 primer Ruberold HW Smooth
Adhesive at 1.5 gal/s uare
OlyBond 500,.12•inch O.C.
-2025
4F Matrix 307 Premium Asphalt Primer or ASTM D41 primer One or two plies, GAFGLAS #75 Base Sheet, Trl-Ply q75 Base
Torch -applied
OI Bond 500,12-Inch o:c.
-232.5
Sheet, GAFGLAS Ply 4, Tri-PI PI 4 or GAFGGLAS FlezPl 6
Hot asphalt applied
OlyBond 500, 12•Inch o.c.
23. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on
-352.5
allowable wind loads. Refer to FBC (HVHZ)1620
and RAS 128 for determination
of design wind loads.
Exterior Research and Design, LLC d/b/a Trinity END.
Author
Certificate Of Roben Robert NlNttion 49503 Evaluation Report 01506.12.13-1-R33 far FL36730-R12
Prepared by: eminen, PE-59166 FBC NVHLINALUgT10N
GAF; (800) 766-3411 Revision 13: 02/16/2017
Appendix 1, Page 5 of 84
0
TRINITYi ERD
TABLE2B-2q;LIGHTWEIGHT{ONCRETEDECK NEW.CONSTRUCTIONr RERDOF(TEAR OFF)`OR',RECOVER
SYSTEM'TYPE C if'MECHANICALLY ATTACHED'.INSULATIONJPLATE,BONDED ROOF COVER';
System Deck LWC - No. (Note 1) (Note 15) Insulation layer Attachment MOP
Fasteners (Note 4) Density Roof Cover
Min. 22 o., Min. 200 psi, min. 2- (Psf)
g type BV, Grade (Optional)One or more layers, Drill-Tec XHD and Drill-Tec
LWC-32. 33 steel; 6'spans, 5/8-inch Inch thick cellular arty combination, preliminarily RhlnaBund TPO XHD Plates Maz. 24-inch o.c In rows XHD Plates or DEverGuard TPO bonec toRhiDrII°nd TPO XHD Tread
TPO
puddle welds, 6"o.c. lightweight Insulating attached(Tread Safe=min, 2- or Drill-Tec Rhlnoeond TPO s aced maz.30-inch o.c. Safe Plates with RhinoBond Portable Bonding Tool,
concrete. Inch thick insulation p -52.5
XHDTread Safe Plates per manufacturers published instructions.
TABLE4D:.LIGHTWEIGHT. CONCRETE DE'N15 CONST7iUCfION; RER00F. (TEAR OFe)'on R¢COYER' - :SYSTEN4 TYPE D-Si MECHANICALLYHE1111 400FCOVER_(n4RouGHLWICTo.EncAG[srxuciuwupiat).;-'
system7steel;6'span
Deck. LWC Insulation
No.ote 1) (Nate 15) Roaf Cover.
TYPO Attach Menibrane Fasteners 4) MOP
go.,type BV, Grade MIn.200 psi, min.2- Attachment (Ps9
Inch thick cellular (Optional) One or more EverGuard Drill-Tec XHD with Drill-Tec 2 in. LWC-33. s, 5/8-Inch puddle Prelim. TPO ar lightweight insulating layers, any combination, Double Barbed XHD Plates, DrilHTec 12-Inch D.C. within 6-inch wide laps SaceE54-
concrete, min. 0.25-Inch attach EverGuard Eyehook AccuSeam Plates or Drill- Inch D.0 and sealed with a lS-in hheat weld. -45.0
TPO.FB Ultra Teo 2-3/81n. Barbed XHD Plates Min: 22 go
type B, Grade 33 FBC HVHZ approved (Optional) One or more Drill-TecXHD(steelonly)orDrill-
LWC-34. . steel; 6'spars, Tm)W5 screw cellular lightweight layers, any combination, Prelim. EverGuard Teo 414 Fasteners(concrete only) Fastened through to engage structural deck,6.
6" olc orstructrural concrete Insulating concrete min. 1-Inch attach TPO FB Ultra with Drill-Tec 23/8In. Barbed XHD Inch D.C. within min. 6-Inch wide laps spaced 114- -45.0
Wm 220a.,rype B,Gmde80 FBC HVHZa raved Plates inch D.C. and sealed with a 1.625-Inch heat weld.
PP (Option al) Combination
more Prelim. EverGuard Drill-Tec SXHD with Ddll-Tec 23/4 Fastened through to engage str°cturaldeck,l2-
LWC-35. steel; 6'spans, TmoC/S screw cellular lightweight layers, any One
or ore
6° D.C. Insulating concrete min, 0.25-Inch attach TPO In. Barbed S%HD Plates Inch ox within 5.5-Inch wide laps spaced 114.5- -45.0
Min. 22 ga., rype.B, Grade 80 FBC HVHZapproved (Optional)One or more Inch D.C. and sealed with a lS-inch heat weld.
LWC-36. steel; 6'spans,:rmar/S screw • cellular lightweight layers, any combination, Prelim, EverGuard Drill-Tec XHD with Drill-Tec 23/8 in. Fastened through to engage structural deck,6-
6"o.c• Insulating concrete min. 0.25-Inch attach TPO Barbed XHD Plates or Drill-Tec2 in. Inch D.C. within 5-Inch wide laps spaced 115•Inch -52.5
Min. 22 ga., type BV(0.5%), Double Barbed XHD Plates _ D.C. and sealed with a I.5-Inch heat weld
Min. 200 psi, min. 3- (Optional) One or more Drill-Tec XHD with Drill-Tec2-3/8In.
LWC-37. puddle welds
6'spans, 5/8' layers, any combination, Prelim. EverGuard Barbed XHD Plates, Drill -To Fastened through to engage structural deck,6.
puddle welds 6"o.c. Inch thick Elastizell Attach TPO Inch D.C.within 6-Inch wide la
min. 1•Inch EyehookAttuSeam Plates or Drill- laps spaced 114-Inch -52.5
Teo 2 In. Double Barbed XHD Plates D.C. and sealed with a 1.5-inch heat weld.
Min. 22 ga., type B, Grade 33 FBC HVHZ approved (Optional) One ormore Drill-Tec %HD steel on IV) orDrill-
LWC-38. steel; 6'spans,Trezz/5 screw celllightweight layers, any Combination,
min. Prelim. EverGuard Teo 414 Fasteners (concrete only) inch D.C.Fastenedwthin min.6inch wide lap, spacedG
6"o.c. orstmttrural concrete Insulating concrete 1-Inch attach TPO FB Ultra with Drill-Tec 23/8 In. Barbed XHD 112.5-Inch D.C. and sealed whha1.625-Inch heat
60.0
Min. 22 ga.; type BV (0.5%), MIn. 330 si, min. 2• Platesore. weld.
LWG39. puddle
dle weld 66Dspans, 5/8" Inch thick Celmre IaOyeq any mmbination, Prelim. EverGuard Dr111-Tec XHD with Drill-Tec23/B In. k, 6-
Cellular through to engage structural der pudtlle welds 6"o.c, Cellular Concrete min. 0.25-Inch attach TPO Barbed XHD Plates Inch D.C. within 6-Inch wide la ss aced 90-Inch MIn. 22 ga., type BV 0.5%, p a -60.0
( ) MIn.330 psi, min. 2- (Optianal)One or more D.C. and sealed whhal.5-Inch heat weld.
LWC-40. Grade 33 Steel; 6'spans, 5/8 . Inch thick Celcore layers, any combination, Prelim. EverGuard Drill-Tec XHD with Drill-Tec 21n. Fastenedthroughtoengage Stmtturaldeck,6-
puddle welds 6 oc _ Cellular Concrete min. 0.25-Inch attach TPO Double Barbed XHD Plates Inch D.C. within 6-inch wide laps spaced 114-Inch
�LW -57711 stee 6eaaospTBfGr�_Seri > FBC HVHghtweiapproved (Optipnap One or more
o c, and sealed with a 1.5•Inch heatweld.. -60.0
„• P ,aralaj/Screw cellular lightweight layers, any combination, Prelim. EverGuard Drill-Tec XHO,with'Dn0-Tec23Z4 in: nFaed th7orgp;p engage struetu-jai deek, 6- `L
'�iO c•pinsulating concrete min. 0.2SInch t>'ta� TPO' Sartled_3_N16eI tesf-^^-�' F^that viRhln6,-nth v icjrjpsspaced]314•mchr'l
ek`5+in9 " laz..aadsealed wi h a 1,5H6 aAweid i"
DPvlSdeclt
Ezterlor Research and Design, LLG d/b/e Trinity(ERD /�%dM j
Prepared
repCertiacateaf Robert
NiemieniPE- � - Evaluation Repart01506.12.13-1-R33 for R36730-R32
Prepar ate of Robert Nieminen; PE-591 ppp FBC HVHZ EVALUATION
L E
T� LyGAF; (800) 766-3411 Revision 13: Page
57 of 84
Appendix 1, Page 57 of 84
Lab Report No. 127553A-6
07 FLORIDAI TEC
PROVIDING SOLUTIONS TO THE ROORNG WDUS
CA # 30448
Lab Certificate # 17-0703.01
FIELD WITHDRAWAL RESISTANCE TEST RESULTS TAS-105
TEST DATE: Au ust 17, 2017
COMPANYNAA&: Tecta America
PROJECT ADDRESS: 4810 - 4818 N Kings Hwy, Fort Pierce MILE COPY
Note: The undersigned representative agrees that all testing has been conducted and results have been reported in
compliance with Miami Dade County Protocol TAS 105 or TAS 105A.
FIELD TECHNICIAN:
EQUIPMENT INFORMATION:
Test Apparatus:
Com-Ten
Blanco
2000 / SPl-lKD-RS
Deck Type: -- = Meta I -
Min Characteristic '275 or above.
Resistance Force: -
See following pages for more details.
DISCLAIMER
All r pen ations performed by Florida Tec, Inc. in order to perform the required number of tests will ONLY be sealed on a
li ited F,.LI�ORARY basis. Contractor and/or owner are responsible to perform permanent repairs to avoid any roof leaks.
P.E.
10735 SW 216v' St. Unit 416 Page 1 of 3 Tel: 305-256-4550
Miami FL 33170 www.FloridaTEC.net Fax: 305-256-6833
FLO 4 TEC
PROVIDING SOLUTIONS TO THE ROOFfNG INDUSTRY
FIELD WITHDRAWAL RESISTANCE TEST RECORDING SHEET
Roof
Area:
BUILDING/ROOF SYSTEM INFORMATION
Roof Area Dimensions: Height:
15Fr
Length:
92 FT
Second Largest Dimension:
7Fr
Total Roof Area:
644Fr
Squares:
6
DECK TYPE
FASTENER INSTALLATION INFORMATION
FastenerType:
Is the fastener a self -driller?
Number of tests conducted:
Component to be secured:
Pre -drilled?
Metal
NISXHDFasteners
YES
10
Anchor or Bose Sheet
YES
Test-1—
:Number.;
PI'..'...;
.Identifiers
Indiai&Failure
r�
,.,. Load. Ib
Field
Perimete ,ortCorneriArea
,y
1
A
466
Comer
2
475
Comer,
3
495
Field
4
573
Perimeter
5
529
Field
6 `
512
Field
7
S27
Field
8
478
Perimeter
9
566
Perimeter
10
520
Comer
STATISTICAL ANALYSIS:
Mean Failure Load:
Sample Standard Deviation:
Min. Charasteristic Resistance Force:
It 513.10
Sr— 36_41
F= 487.08
MINEAN-OW4,
• M M
bi
10735 SW 2161' St. Unit 416 Page 2 of 3 Tel: 305-256-4550
Miami FL 33170 www.FloridaTEC.net Fax: 305-256-6833
FLORIDA TE'C
PROVIDING SOLE ONS TO THE ROOFlNG INOuI y
Roof Are
Grounl
ROOF SKETCH:
9z
W ' 05 �
07 09 10
02 �3 *4 �6 08
T
7'
L
10735 SW 216th St. Unit 416 Tel: 305-256-4550
Miami FL 33170 Page 3 of 3 Fax: 305-256-6833
www.FloridaTEC.net
Lab Report No. 127553B-6
FLORIDAI TEC
PROVIDING SOLUTIONS TO THE ROOFING INDUSTRY
CA. # 30448
Lab Certificate # 17-0703.01
DATE: August 18, 2017
COMPANYNAd1E: TectaAmerica
PRoJECTADDREss: 4810 - 4818 N Kings Hwy, Fort Pierce
ASCE 7-10
Input Parameters: Directional Procedure All
Heights Building (Ch 27
Part 1)
Basic Wind Speed(V) =
170.00 mph
Structural Category =
II
Exposure Category
= C
Natural Frequency =
N/A
Flexible Structure
= No
Importance Factor =
1.00
Ed Directional Factor
= 0.85
Alpha =
9.50
Zg
= 900.00
ft
At =
0.11
Bt
= 1.00
Am =
0.15
BM
= 0.65
Cc =
0.20
1
= 500.00
£t
Epsilon =
0.20
Zmin
= 15.00
ft
Pitch of Roof =
0 : 12
Slope of Roof(Theta)
_ .00
Deg
h: Mean Roof Ht =
15.00 ft
Type of Roof
= FLAT
RHt: Ridge Ht =
15.00 ft
Eht: Eave Height
= 15.00
ft
OH: Roof Overhang at Eave=
.00 ft
Overhead Type
= No Overhang
Bldg Length Along Ridge =
92.00 ft
Bldg Width Across Ridge= 7.00
ft
Wind Pressure on Components and Cladding (Ch 30 Part 1)
All pressures shown are based upon ASO Design, with a Load Factor of .6
Width of Pressure Coefficient Zone ^a^ = = 3.00 ft
Description Width Span Area Zone Max Min Max P Min P
£t ft ft-2 GCp GCp psf Pee
Field 2.00 5.00 10.0 1 0.30 -1.00 15.37 -37.80
Perimeter 2.00 5.00 10.0 2 0.30 -1.80 15.37 -63.42
Corner 2.00 5.00 10.0 3 0.30 -2.80 15.37 -95.45
FASTENER SPACING CALCULATION
NOA: 171,16730-R12
Fastener Spacing Calculated In Accordance WithRAS-137 System Type: LWC-41
" ,rMaiDesiguPressure^>
_ :tiZ/=Fastener':'++`
�. 3,^F
-Mck:Type
60 y
r
,
285
t Metal
475
DevatedPressureZGne
Fasteners Spacing.
Sheet Width
=..
,(inch)
(inch) _-
". 11e1d .
37.80',
6
114
enmeters'='f
:. 6142
12
35
12
35
P.E.
Perimeter
Width (inch)'
36.0
,y j¢w YYs�r �3
gulf ARE t