.' AyF a °�� °t,� ° 'gyp °�� "6�a ®� e.` , ; •. r �� ° ��\�' .* � ..^_ti
y
Business& Frofessiotalesptla#ton �e
OF '•.• * e • y. ° s�§`; .Oexrt1 ASduf osPliotv(el4E
dFlorida b PrProduct Approval
USER: Public User
tu3P
Produd Aeprvval Menu > Product or Application Search > AooRabpn List > Applirathsn Detail
FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed
the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
FL16730-R13
Revision
2014
Approved
n
GAF
1 Campus Drive
Parisppany, NJ 07054
(800) 766-3411
mstieh@gaf.com
Robert Nieminen
lindareith@trinityerd.com
William Broussard
1 Campus Drive
Parsippany, NJ 07054
(800) 766-3411
TechnimiQuestionsGAF@gaf.com
Roofing
Single Ply Roof Systems
ST. LUCIE COUNTY
BUILDING DIVISION
REVIEWED
FOR COMPLIANG$�
'D BY
MUST BE KEPT ON JOB OR
NO INSPECTION WILL BE MADE
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
❑ Evaluation Report- Hardcopy Received
Robert Nieminen
PE-59166
UL LLC
10/18/2018
John W. Knezevich, PE
Validation Checklist - Hardcopy Received
F4F673Q R13 401 17 41 CpI Ni rninen,pdf
Referenced Standard and Year (of Standard) Standard
TAS 110
TAS 114
TAS 131
Equivalence of Product Standards
Certified By
Sections from the Code
year
2000
2011
1995
THESC PLANS AND ALL PROPOSCD WORK
ARE SUBJECT TO ANY COPRECTIONS
REQUIRED BY PICLD INSPECTORS THAT
MAY BE NECESSARY IN ORD29 TO
COMPLY WITH ALL APPMADLE CODES.
http://www.floridabuilding.orglprlpr_app_dtl.aspx?param=wGEV XQwtDqu8obl%2flZm... 11 /20/2017
'Florida Building Code Onlin- -,
Page 2 of 2- -
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Date Revised
Summary of Products
Method 1 Option D
08/1/2017 V1 T
q F 08/18/2017 I
08/24/2017 FLI
LE (MV
10/10/2017
10/17/2017
FL #
Model, Number or Name
Description
16730.1
Ever -Guard TPO Single Ply Roof
Thermoplastic polyolefiln single ply roof systems
Systems
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FLI 730 Rl11 2017 08 FINALAl ER GAF EG
TPO HVHZ FL16730-R33.odf
Approved for use outside HVHZ: No
Impact Resistant: N/A
Verified By: Robert Nieminen PE-59166
Design Pressure: +N/A/-502.5
Created by Independent Third Party: Yes
Other: 1.) The design pressure herein pertains to one
Evaluation Reports
system. Refer to ER Appendix for all systems and maximum
FL16730 R13 AE 2017 08 FINAL ER GAF EG
design pressures. 2.) Refer to ER Section 5 for Limits of Use.
TPO HVH7 FL16730-R13.odf
Created by Independent Third Party: Yes
Pack nett
Contact Us :: 2601 Blair Stone Road. Tallahassee B. 32399 Phone: 850487-3824
The State of Florida is an A vEED employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: AcceS5lbibty Statement :: Refund Statement
Under Florida law, email addresses are public rea is. If you do not want your a -mall address released in response m a public -records retuest, do not send
lectronic mall to this entity. Instead, contact the office by phone or by traditional mall. If you have any guestlons, please contact 850.487.1395. *Pursuant to
dlon 455.275(1), Florida statutes, eBechve October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if
ley have one. The emai s provided may be used for official communication with the licensee. However email addresses are public remm. If you do not wish m
ly a personal address, please provide the Department with an emall address which an be made available to the public. To determine if you are a licensee under
chapter 455, F.S., please click lb 1 .
Product Approval Accepts:
M M ® RE M
SCCIlrtl?'hi6-1'R1C5
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDqu8ob101o2fIZm... 11 /20/2017
Drawing Report
Indrio Crossings - Alternate Bid I - Reroof GAF TP-O 8/18/17
Section: Entire Job
Page: Rooms
I
1*� A■ 7
g
C 0
Tecta America South Florida -1431 SW 30th Avenue Deerfield Beach Florida Phone: 954419-9339
Florida Building Code Sth Edition (2014)
High -Velocity Hurricane Zone Uniform Permit Application Form
Section' C: (Low Sloped Roof Svidem)
FIR, In Speclfb; Roof Assembly Components
and Identify Manufaqurer
(Ha 6orripaneM M irorired, IOerrtlfy ae'NA�
System Marttdaduer. cnF
NC)ANa. F116736R72.
Design Wind Preaewas, From RAS 128 or Calculations:
P 1=1 a7.80 'per $3A2 . Prl ea B5A1
Meic D.aslgn PreWre, From the Spsi fie NOA
Deck.
- TYPe- LWIC over Steer
am-, 22 ga
Slope. 1/4"hi min -
AndrotlBeseSheet6Ntr:ofPly(a): NA -
AnchodBase Sheet Fasten Material:
Insuaton Base Layer NA N- -
Bats Inswetion Sze arw Thidmess- NA
Base Irssikon FastenerlBondag Mafertrai:
Topinstrlaticirti er. Dens Deck
Top Insulation Stze and Thldarasr 4X4z1/2
Top Insul fon FastenerAWWing Materiel
#15 Fastener
Base Snest(s) & No. or ply(s)-NA _
- Baca Sheet Fastener/BorWing Material
. - NA .
PlySheet(a)A No. of Ply(s);
Pry Sheet NEesteneriBomcling Material:
ppy To:aGa/t►AFFa60 Mil TPO
Top Ply Fif16,FIrKft
Meterial - .
asttsoar
Sts(adng: NA
Fastener Spseing for Anchorl6sp Shoat
AftachnWi tt See IEngineerinq
114" sheet.width
F7e14: s' 'ae®L>ap,llRowa_�'_ orS.
42"sheet width
Pertmeter 10'oo@Lap, .eRom _(t3 00
42" sheet width:
Comer 1v'oo®Lep.0Rbws_@_ oe
Number offesteners Per lnsulaho'n
dowd P�elimi .Fastened
4 fasteners per 4z8 board
Fleld _ Perimeter _Comer
Illusfraia Components Noted and
D"s as -Applicable:
WoodWocking. Gutter, ' Edge Termination;
Stripping,. Flashing, Continuous C;aA Corti
Strip. ', Base Flashing, Counter- Flashing,
C 104 Etc.. .. .
Indlrol: Mean Roof Height Parapet Height;
Height of Base Fla ping, Component Material,
Materiel ThIcknese, Fastener Type, Fastener.
Spacing or Submit Menuradurere Details that
Ccmply with RAS 111 and Cho .
24 ga coping fastened 12" oc
w/ 1110, fasteners
22 go deat fastened w/:
129a annular roofing nails 4"
Top Ply 6
Insulation,
-jr Lightweight -
Over Steel Deck-
�- New Gutter 8 D
Spout.. See Detail '
I I I Fr.I 3r+
TECTAr,,MERICA
South Florida, Inc.
Florida Product Approval
IN E rim I
MA
M /HIM@
Tecta America South Florida Inc. 11431 SW 30th Avenue, Deerfield Beach, FL 334421 T. 954.419.9339 F: 954.419.9337 tectaamerica.com
Exterior Re searchand Design, 03 d/6/a Trinity ERDCert. ��
Prepared bv: AuthoRobert lz�
01-1
EVALUATION
Prepared bv: Rohert Nleminen, PE-59166
(, 8 )7663411
Evaluation Report 01506.12.13-1-R13 for FL16730-R32
Revision 13: 02/16/2017
Appendix 1, Page 1 of 84
eJI RlNIW I ERD
The following notes apply to the systems outlined herein:
i
1. The evaluation herein pertains to above -deck roof components;. deck -attachment details pertaln to 'as -tested' conditions under TAS 114, Appendix 1. Roof decks shallbeIn accordance with FBC (HVHZ) requirements
to the satisfaction of the AHI.
2. Unless otherwise noted, fasteners and stress plates for insulation or base sheet attachment shall be as follows.. Fasteners shall be of sufficient length for the following engagements:
➢ Wood Deck: Drill-Tec 912 Fastener or Drill-Tec #14 Fastener with Drill-Tec 3" Standard Steel Plate, Drill -Tee 3" Steel Plate, Drill-Tec 3In. Ribbed Galvalume Plate (Flat) or Drill-Tec AccuTrac Flat Bottom
Plate or Drill-Tec AccuTrac Recessed Plate (insulation only),. Drill-Tec ASAP 3S or Drill-Tec Heavy Duty ASAP 3S. Min. 0.75-Inch plywood penetration or minimum 1-Inch wood plank
embedment.
D Steel Deck: Drill-Tec #12 Fastener, Drill-Tec H34 Fastener or Drill-Tec XHD Fastener with Drill-Tec 3" Standard Steel Plate, Drill-Tec 3" Steel Plate, Drill-Tec 3 in. Ribbed Galvalume Plate (Flat) or Drill -
Tee AccuTrac Flat Bottom Plate or Drill-Tec AccuTrac Recessed Plate (insulation only); Minimum 0.75-Inch steel penetration, engage the top flute of the steel deck.
➢ Structural concrete: Drill-Tec #14 Fastener or Drill-Tec CD-10 with Drill-Tec 3" Standard Steel Plate; Drill-Tec 3" Steel Plate, Drill-Tec 3 In. Ribbed Galvalume Plate (Flat) or.Drill-Tec AccuTrac Flat Bottom Plate
or Drill-Tec AccuTrac Recessed.Plate (Insulation only) or.Drill-Tec Heavy Duty ASAP 35. Minimum 1.25-Inch. embedment. Fasteners Installed with a pilot hole In accordance with the
fastener manufacturer's published installation Instructions.
3. Unless otherwise noted, insulation may be any one layer or combination of polylsocyanurate, polystyrene, wood fiberboard, perllte, gypsum -based roof board or mineral wool roof board that meets the OA
requirements of F.A.C. Rule 61G20.3. and is documented as meeting FBC (HVHZ)1516 and, for foam plastic, FBC Chapter 26, when installed with the roof cover.
Refer to GAF published Installation instructions for details and requirements regarding the use of FBC HVHZ approved polystyrene insulation In EverGuard® roofing systems:
Insulation: High Traffic Applications: Recover Applications:
➢ FBC HVHZ approved Expaned polystyrene (EPS) meeting or ➢ FBC HVHZ approved Extruded polystyrene (XPS) meeting or ➢ FBC HVHZ approved XPS Fan -Fold Recover Board with plastic
exceeding TAS 110 and ASTM C578, Type IX, nominal 1.8 Ib/ft2 exceeding TAS 110 and ASTM C578, Type IV, minimum 1-Inch facer meeting or exceeding 7A5 110 and ASTM C578, Type IV,
density and minimum 25 psi compressive strength. thick and minimum 25 psi compressive strength. 3/8-Inch thick and minimum 25 psi compressive strength.
D FBC HVHZ approved Expanded polystyrene (EPS) with plastic ➢ FBC HVHZ approved Expanded polystyrene (EPS) with plastic ➢ FBC HVHZ approved EPS Recover Board meeting or exceeding
facer meeting or exceeding TAS 110 and ASTM C578, Type IX, facer meeting or exceeding TAS 110 and ASTM C578, Type IX,, TAS 110 and ASTM C578, Type IX, 1/2-Inch thick and minimum 25
nominal 1.8 Ib/ft2 density and minimum 25 psi compressive minimum 1-Inch thick and minimum 25 psi compressive strength. psi compressive strength.
strength. ➢ FBC HVHZ approved EPS Recover Board with plastic facer
meeting or exceeding TAS 110 and ASTM C578, Type IX, 1/2-Inch
thick and minimum 25 psi compressive strength.
TOPCOAT- FlreOut- Fire Barrier Coating, VersaShleld® Flre-Resistant Roof Deck Protection or VersaShleld• Solo"' Fire -Resistant Slip Sheet, installed in accordance with GAF published Installation instructions and fire
resistance certification listings, may be used as a non -load -bearing, fire -barrier/ slip -sheet component within any system outlined herein.
4. If mechanical attachment to the structural deck through lightweight Insulating concrete is proposed, field withdrawal resistance testing shall be performed to confirm equivalent or determine enhanced fastening
patterns and density. All testing and fastening design shall be In compliance with Testing Application Standard TAS 105 and Roofing Application Standard RAS 117 and/or RAS 137. Calculations shall be prepared,
signed and sealed by a qualified design professional.
S. Preliminary insulation attachment for System Type C-2 and D= Minimum fourfasteners per 4X 8 ft board or minimum two fasteners per 4 x 4 it board.
6. Unless otherwise noted, Insulation adhesive application rates are as follows. Ribbon or head width Is at the time of application; the ribbons/beads shall expand as noted In the manufacturer's Published Instructions.
➢ Hot Asphalt (HA): Full mopping, 25-30lbs/square.
➢ GAF 2-Part Roofing Adhesive (GAF 2-Part): Continuous 2.5 to 3.5=Inch ribbons, 12-Incho.c.
➢ LRF Adhesive M (LRF-M): Continuous 0.75 to 1-Inch wide ribbons„12-Inch o.c.
D OlyBond Adhesive Fastener (Classic): Full coverage,1 gal/square.
➢ OlyBond 500 (OB500): Continuous 0.75 to 1-inch wide ribbons, 12-Inch o.c. using PaceCart or SpotShot. Note: OlyBond Classic or OlyBond 5GO Green maybe used In place of OB500;
➢ Note: When multiple layers(s)ofInsulation 'and/orcoverboard are Installed in ribbon -applied adhesive, board/ointsshall be staggered.
➢ Note: The maximum edge distance from the adhesiveribbon to the edge of the Insulation board shall benot less than one-half the specified ribbons spacing.
7. Unless otherwise noted, all insulations are flat stock or taper board of the minimum thickness noted. Tapered polylsocyanurete at the following thickness limitations maybe substituted with the following Maximum
Design Pressure (MDP) limitations. In no case shall these values be used to 'Increase' the MOP listings In the tables; rather if MOP listing below meets or exceeds that listed for a particular system In the tables, then
the thinner board listed below may be used as a drop -in for the equivalent thicker material listed in the table.
Exterior Research and Design, U.C. d/b/a TrinityI ERD
Certificate of Authorization a9503 � � � FBC HVNZ0V766-34 ON Evaluation Report 01506.12.1Appendfor FL3673 of 84
Prepared by: Robert Nieminen, PE-S 66 GAF; (600) 766.34IO Revlslon 13: 02/16/2017
Appendix 1, Page 2 of 84
D Hot Asphalt (HA): TRINITYERD
D GAF 2-Part Roofing Adhesive (GAF 2-Part): MDP- -117.5 psf (Min. 1.0-inch thick)
'> LRF Adhesive M (LRF-M): MDP = -2325 psf (Min. 0.5-Inch thick EnergyGuard Polyiso Insulation, EnergyGuard NH POIyIso Insulation, EnergyGuard Ultra Polyiso Insulation,
➢ OlyBond 500 (OB500): EnergyGuard NH Ultra Polyiso Insulation)
> OlyBond 500 (OB500): MDP = -315.0 psf (Min. 0.5-Inch thick EnergyGuard RH or RN)
MDP.= -487.5 psf (Mtn. 0.5-Inch thick EnergyGuard RA)
> OlyBond Boo (OB500): MDP = -2925 psf (Min. 0.5-inch thick EnergyGuard Polyiso Insulation, EnergyGuard NH Polyiso Insulation, EnergyGuard Ultra Polyiso Insulation,
EnergyGuard NH Ultra Polyiso Insulation)
8. Bonded polyisocyanurate Insulation boards shall be maximum 4x4ft.
9. Perimeter and corner areas shall Comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be Increased, as calculated in compliance with Roofing Application Standard RAS 117 -
and/or RAS 137 by a qualified design professional. "This extrapolation is notpermittedforsystems marked with an"tedW.
10. .For assemblies marked with an asterisk•, the maximum design pressure (MDP) limitationlisted shall be applicable to all roof pressure zones (i.e., field, perimeters and comers). Neither rational analysis, nor
extrapolation is permitted for enhanced attachment at enhanced pressure zones (i.e., perimeters, corners and extended corners).
11. .Fastener spacing for mechanical attachment is based on a minimum fastener resistance value in conjunction with the maximum design pressure (MDP) listed for a specific system. Should the fastener resistance be
less than that required, as determined bythe Building Official, a revised fastener spacing —prepared, signed and sealed by a qualified design professional —may be submitted. Said revised fastener spacing shall utilize
the withdrawal resistance value taken from Testing Application Standard TAS 105 and calculations In compliance with Roofng Application Standard RAS 117 or RAS 137.
12. For bonded Insulation or membrane over existing substrates In a recover installation, the existing roof system shall be capable of resisting project design pressures on Its own merit to the satisfaction of the AHJ, as
documented through field uplift testing In accordance with TAS124.
13._ For System Type D, steel deck applications, the roof membrane shall be run with Its length perpendicular to the steel deckflutes.
14. For recover Installations, the existing roof shall be examined In accordance with FBC 1521. For Recover Applications using System Type C-2 or or any System Type D, the Insulation is optional. Alternatively, a
separator board maybe Installed prior to roof cover Installation when using System Type C-2 or any System Type D or a separator sheet maybe Installed prior to roof cover installation when using any System Type D.
The separator component shall be documented as meeting FBC (HVHZ)1516 and, forfoam plastic, FBC Chapter 26, when Installed with the roof cover In Recover applications.
> Separator Board Option for Recovers stem Type C 2 or System Type O Min. 0.5-Inch Ener
Polyiso Insulation, EnergyGuard NH Ultra Polyiso Insulation, Structodeck High Density Fiberboard Roof insuard iulationso l Ener EnergyGuard RH HD and NH Polyiso Insulation, EnergyGuard
H RA, EnergyGuard Insulation,
n, EnergyGuard Ultra
Polyiso lnsulatlon, EnergyGuard HD Plus Polylso Insulation or EnergyGuard NH HD Plus Polyiso Insulation or min. 0.25-inch De s De k, DensiDeck Primeso ,ISECUROCK Gypsuum-F bier Roof Board or SEROCK NH Glass -
Mat Roof Board.
> Separator Sheet Options for Recover System Type D EverGuard Polymat Separation Layer (3 oz/yd') or EverGuard Polymat Cushioning Layer (6 oz/yd'). "
I5. For systems where speclflc lightweight Insulating concrete (LWIC) is referenced, refer to current LWIC Product Approvalfor specific deck construction and limitations. Unless otherwise noted, for systems where /
specific LWIC is not referenced, the minimum design mix shall be 300 psl.
16. Side laps for EverGuard Freedom TPO with RapidSeam Technology are self -adhering. Side laps for EverGuard Freedom TPO HW are heat welded. Unless otherwise noted, reference to EverGuard Freedom TPO In this
Appendix relates to either. method.
Ay;7
Extedof Research and Design, LLG d/b/a TdnitylERD
Certificatey: AuthRobert
Nleon 99503 Evaluation Report 01506.12.13-1-R33 for FL36730-R11
Prepared by: Robert Nleminen, PE-59166 FBC
GAF (800) 66-34 1R Revision 13:02/16/2017
Appendix 1, Page 3 of 84
17. For adhesive -applied membrane systems, side laps shall. be minimum 3-Inch wide sealed with min. 1.5-Inch heat weld. Unless otherwise noted, membrane adhesive application rates are as follows: i
EverGuard TPO
tve�u= rPO #2121 Bonding Adhesive
(#1121
(#1121)
Contact (both sides)
0.8to1.Ogal/square/surface. For use over SECUROCK Gypsum -Fiber Roof Board, the application
rate
changes to 1.2 to 1.67 gal/s /surface
EverGuard TPO
EverGuard WB181 Bonding Adhesive (WB181)
Contact (both sides)
To Polylsoty -
at 0.63 gal/squaretand roof cover underside or
EverGuard TPO
EverGuard Low VOC TPO Bonding Adhesive (L-
aDensl
0.21 gal/square. To ens DeckbPrime SE_CUROCK Gypsum
Fiber Roof Board at 0.63 to 0.75 gallsquare and roof miter underside at 0.21 to 0.25 al/s uare
VOC)
Contact (both sides)
0.46 gal/square/surface
EverGuard TPO
EverGuard 1 Fu 6 bquare Low VOC Bonding
Adhesive TPO 3-S uare)
Contact (both sides)
0.84 gal/square/surface
EverGuard TPO FB Ultra I GAF LRF,Adheslve M (LRF-M) or LRF Adhesive I I i-Inch witle ribbons spacetl as noted in tables herein. Note: The adhesive ribbons are iocated directly over
0 (LRF-0) Wet lay (substrate) the adhesive ribbons used to secure the insulation when the cover is bonded to insulation less than SS -Inch thick.
28. The "Triposite Roofing System" noted herein consists of loose -laid GAFGLAS Stratavent Perforated Venting Base Sheet, followed by asphalt -applied two (2) plies of Ruberoid 20 Smooth or three (3) plies of GAF
FlexPly 6, followed by asphalt-applled 80-mil EverGuard TPO FB Ultra with 1-5/8" heat welded side laps. GLAS
19. Unless otherwise noted, the "Hybrid Roofing System" noted herein consists of asphalt -applied Ruberold 20 Smooth, Ruberold Mop. Smooth, Ruberold Mop Smooth 1.5, GAFGLAS #75 Base Sheet, Tri-Ply #75 Base
Sheet or GAFGLAS #80 Ultima.Base Sheet followed by asphalt -applied EverGuard TPO FB Ultra.
20. EverGuard Extreme TPO may be used as an altemate to EverGuard TPO. EverGuard Extreme TPO FB Ultra may be used as an alternate to EverGuard TPO FB Ultra.
21. The following Insulations are interchangeable within the scope of this Evaluation Report:
D EnergyGuard Polyiso Insulation.* EnergyGuard NH POMso Insulation;
> EnergyGuard Ultra Polyiso Insulation * EnergyGuard NH Ultra Polyiso Insulation;
➢ EnergyGuard HD Polyiso Insulation * EnergyGuard NH HD Polyiso Insulation;
> EnergyGuard HD Plus Polyiso Insulation * EnergyGuard NH HD Plus Polyiso Insulation.
FmILE COPY
Exterior Research and Design, U.C. d/b/a Trinityl ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
FRCHVHLEVALUAmON
GAF; (800) 766-3411
Evaluation Report 01506.12.13-1-R13 for FL36730-R32
Revision 13: 02/16/2017
Appendix 1, Page 4 of 84
22. Vapor barrier options for over structural con r v' 1 RINI e � 'ERD
c ete deck with adhered Insulation carry the following Maximum Design Pressure (MDP) limitations The lesser of the MDP listings below vs. those In Table 3A applies:
'VAPoaBApaIER OPDONS STRUCTUpAtiANCRETE DE[x ADHERFD INSODITION PERTABlEN - DU,
�i
Option W
1
2A
2B
2C
2D
2E
3A
3B
Primer
Matrix 307 Premium Asphalt Primer or ASTM D41 primer 'I One or two
Matrix 307 Premium Asphalt Primer or ASTM D41 primer
Matrix 307 Premium Asphalt Primer or ASTM D41 primer I
One
or
4D
I Matrix 307 Premium Asphalt Primer or ASTM D41
primer
Ruberold 20 Smooth
4E
Matrix 307 Premium Asphalt Primer or M I V41
primer
Ruberold HW S n
4F
I Matrix 307 Premium Asphalt Primer or ASTM D41
primer
One or two piles, GAI
Hot asphalt applied
Base !b I Hot asphalt applied
Hot asphalt applied
102
Hot asphalt applied
Insulation Adhesive MDP(psf)
Hot asphalt -360.0
GAF 2-Part, 12-Inch o.c.
-169.0
GAF 2-Part, 12-Inch O.C.
-180.0
GAF 2-Part, 12-Inch o.c.
1 -250.0
GAF 2-Part, 12-Inch o.c.
1 -2625
LRF-M, 12-Inch mc.
OlyBond 500, 12-Inch o.c.
OlyBond 500 12-Inch o
23. "MDP' = Maximum Design Pressure Is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC (HVHZ)1620 and RAS 128 for determination of design wind loads.
c.
-495.0
-2025
-352.5
Exterior Research and Design, LLC. d/b/a TrinkylERD
Certificate of Robert tion
49503 Evaluation Report 01506.12.13-1-R33 for FL36730.R32
Prepared by: Robert Nieminen, PE-59166 FBC HVH2 EVALUATION
GAF, (800)766-3411 Revision13:02/16/2017
Appendix 1, Page 5 of 84
S
`TABLE2B-2; UGHTWEIGHTCONCRETE DECKS NEW.CONSTRUCTION, REROOF,(TEAq-OFF);On.RECOVER• ' TRIiVIlYIERR
SYSTEM TYPEC=Z?MECHANICALLY AT YACHEOINSULATION;PL ii--BONbtD'R00F;COVER:,
System, Deck LWO
NO• (Note 11 (Note 15) Insulation Layer Attachment
Fasteners(Note4) Density Roof Cover T
Min. 22 ga., type BV, Grade Min. 200 psi, min. 2- (Optional) One or more layers, Drill-Tec XHD and Drill-Tec -ill-Tec Rhino
LWC-32: '33 steel; 6'spam; 5/8-Inch inch thick cellular any combination, preliminarily RhinoBond TPO %HD Plates Max.2a-Inch o.c. In rows XHD Plates or DrEverGuard TPO ill-Tec Ahlnoonded to rBond TPO XHBond TPO
D TrTPO
ead
lightweight insulating attached read Safe - min. 2 or Ddll-Tec RhlnoBond TPO spaced max. 30-Inch d.c. Safe Plate` with RhinoBond Portable Bonding T
Puddle welds, 6" o.c. (T
_ concrete. inch thick insulation) XHD Tread Safe Plates
TABLE 4D:LIGHTWEIGHT CONCRETEDECKS=NEVjYCONSTRUCTION, REROOF(TEAa OFFII ..........oa RECOVER•'
System Deck" LWC
• =SYSTEM TYPE D•1: MECHANICALLY ATTACHE®.ROOF' COVER.(iicaoucH LWICSo.ENGAG85T5u
No. cfuniLL DEcg)ti , •
-
Insulation
'(Note 1) (Note 15) T .Boot Cover -
YP° Attach Membrane Fasteners(Note 4)- MDP
Min. 22 ga., type BV, Grade 33 MIn.200psllular 2- Attachment (psfl
Inch thick cellular (avers, an) One orcombination,
more EverGuard Drill-Tec XHD with Drill-Tec
ato, Din.
LWC-33. welds,"" ans, 5/8-Inch paddle layers, any comhination, Prelim. TPO or Double Barbed XHD Plates, Drill-Tec 12-inch o.c.within6-Inchwidelapsspaced54-
welds,6"o.c. Ightwelght insulating min. 0.25-Inch attach EverGuard Eyehook AccuSeam Plates or Drill- inch o.c. and sealed with a l.5-inch heat weld.
concrete: TPO F8 Ultra Tec2-3/Sin.Barbed XHDPlates -450
Min. 22 ga.; type B, Grade 33 FBC HVHZ approved (Optional) One or more Drill-Tec XHD (steel only) or Drill. LWC•34. steel; 6'spans, TmW5 screw cellular lightweight layers, any combination, Prelim. EverGuard Tec 414 Fasteners(concrete only) Fastenedthrough to engage structural deck, 6-
6' o.c. or structmral concrete Insulating concrete min. 1-Inch attach TPO FB Ultra with Drill-Tec 23/8In, Barbed XHD Inch o.c. within min. 6-Inch wide laps spaced 114- -45.0
1122 ga. type B, Grade 80 FBC HVHZa roved Plates Inch o.c. and sealed with a 1.625•Inch heat weld.
PP (Optional) combs mare Prelim. EverGuard Drill-Tec SXHDwith Drill-Tec LWC-35. steel; 6'. spans, Traxx/5 screw cellular lightweight layers, any combination, Fastened through to engage structural deck, l2-
6"o.e. insulating concrete min. 0.25-Inch attach TPO In. Barbed SXHD Plates Inch o.c. within 5.5-inch wide laps spaced 114.5- -45.0
Min.22ga.,type.B,Grade80 FBCHVHZapproved (Optionaq Oneor more Inch c.c. and sealed with a LS-Inch heatweld.
UTIV . steel; 6'spans, Tma/5 screw cellular""
eight layers, any combination, Prelim. EverGuard Drill-Tec XHD with Drill-7ec23/8 in. Fastened through to engage structural deck,6.
6" o.c. Insulating concrete. min. 0.25-Inch attach TPO Barbed XHD Plates or Drill-Tec 21n. Inch o.c. within S-inch wide laps spaced 115-Inch
BV Double Barbed XHD Plates. O.C. and sealed with a 1.5•inch heatweld. -52.5
MIn.22ga., steel;
spam,5/,One or Drill-Tec XHD with Drill-Tec 2-3/81n.
LWC-37. puddle welds
-o.c. s,5/e' MIh this Psi, tuell (Optional) an) combs more Prelim. EverGuard Barbed XHD Plates, Drill-Tec through to engagestructuraldeck,6-
InchthickElastizell layers, any combination, Fastened throw
puddle welds 6"'o.c. min. 14nch Attach TPO Eyehook AccuSeam Plates or Drill- Inch O.C. within 6-Inch wide laps spaced 114-Inch -52.5
Tec 2 in. Double Barbed XHD Plates 01 and sealed with a 1.5-Inch heat weld.
Min. 22 ga., type B, Grade 33 FBC HVHZ approved (Optional) One or more Drill-Tec XHD steel only) or Drill•
LWC-38. steel; 6'spans,Tmxx/5 screw cellular lightweight layers, any combination, Prelim. EverGuard Tec 414 Fasteners (concrete enly) Inchgmin�6--Inch wide laps sengage 1paced�
6" o.c. orstmctrural concrete .insulating concrete min. 1-Inch attach TPO FB Ultra with Drill-Tec 23/8In. Barbed XHD Inch o.c.
min. 6-Inch
space heat
60.0
Min- 22 ga., type BV.(0,5%), .MIn. 330 I,min. 2- Plates weld.
Ps (Optional) aq One more prelim. EverGuard Drill-Tec with Drill-Tec In.
LWC-39. puGraddle
weld ""'spans, 5/6" -Inch thick Celcore layers, any combination; Fastened through to engage structural deck,6-
-paddle welds 6" o.c Cellular Concrete min. 0.25-Inch attach TPO Barbed XHD Plates Inch o.c. within 6-Inch wide laps spaced 90-Inch -60.0
Min. 22 ga., type BV(0.591), MIn. 330psLmin. 2- (Optional) One or more o.c. and sealed with a 1.5-inch heat weld.
LWC-40. Grade 33 steel; G'spaos, 5/8" inch thick Celcore layers, any combination, Prelim. EverGuard Drill-Tec XHD with Drill-Tec 21n. Fastened through to engage structural Tack, 6-
addlewelds6 oa Cellular Concrete attach TPO inch O.C.within G-inch wide laps aced 114-Inch
Tn. Double Barbed XHD Plates P P -60.0
�., ge 22ga;type 8'�Grade;80r FBC HVHZ approved (Optional) Oneormore oc and sealed with a 1S-Inch heat weld.
Ley steel 6�tspaa4s;TrWxf cr y cellular lightweight layers, any combination, Prelm EverGuard:prut_TecXHD,withDnll-Tec231410; I4astenedthrnugh ngagestmg=.,�
.1 6ro.c.,r- insulating concrete min. 0.25-Inch :attach SPO 68ar6er1gIEIate /�•'�---•-+' IIncho•°• within`&Inch wide laps s
De 5 d ec K (p 0 M ' ( l°•c•.andsealed,Iyit'h ach hea
Erterior Research and Design, LLC d/b/a TrMRyIFBD
Autho
PreparedCertificatbV: Robetization Nlemiit9503 ,,,ff``r;;;***,,s ��Fjjj±±±��^��Evaluation Report 01506.12.13-1-R13 for R16730-R32
Prepared by: RobertNleminen;PE-59166 19LE
�E,1*W._Y76I
ALUATON Revision 13: 02/16/2017
Appendix 1, Page 57 of 94
Lab Report No. 127553A-4
FLORIDA TEC
PROVIDING SOLUTIONS TO THE ROOFING INDUSTRY
CA # 30448
Lab Certificate # 17-0703.01
FIELD WITHDRAWAL RESISTANCE TEST RESULTS TAS-105
=DATE. --August 17, 2017 � • .
COMPANY NAME: Tecta America
PROJECTADDRESS: 4880 - 4882 N Kings Hwy, Fort Pierce
Note: The undersigned representative agrees that all testing has been conducted and results have been reported in
compliance with Miami Dade County Protocol TAS 105 or TAS 105A.
FIELDTECHNICLIN.Angelo Blanco
EQUIPMENT INFORMATION:
Test Apparatus:
Com-Ten FGC 2000 / SP 1-1KD-RS
r
Deck Type: - Wetal
Min Characteristic n 1'✓
275or,abo`.v& ,
Resistance Force:
See following pees for more details.
DISCLAIMER
All roofpen41MARY
erformed by Florida Tec, Inc. in order to perform the required number of tests will ONLY be sealed on a
lim' eVnd basis. Contractor and/or owner are responsible to perform permanent repairs to avoid any roof leaks.
P.E.
10735 SW 2161^ St. Unit 416 Page 1 of 3 Tel: 305-256-4550
Miami FL 33170 Fax: 305-256-6833
www.FloridaTEC.net
FLORIDI TEC
PROVIDING SOLUTIONS TOi ROOFfNG Woos Ry
FIELD WITHDRAWAL RESISTANCE TEST RECORDING SHEET
Roof ffl;04vffi FHLE Area: Ww
COPY
BUILDING/ROOF SYSTEM INFORMATION
Roof Area Dimensions: Height:
15FT
Length:
SOFT
Second Largest Dimension:
38FT
Total Roof Area:
2840FT2
Squares:E
28
DECKTYPE
FASTENER INSTALLATION INFORMATION
FastenerType:
Is the fastenera self -driller?
TESTINFORMATION
Number of tests conducted:
Component to be secured:
Pre -drilled?
Metal
#15XHD Fasteners
YES
S"Sheet
Anchor or
YES
,
_�arj
Offifnittal'Failure
<ieRPer�iniete oCot�n,
.er,Atea n
:.Number-
=ldentl0er_
.::=.Load. Ib
1
A
392
Comer
2
385
Perimeter
3
376
Comer
4 _
417
Field,.
5
470
Perimeter
6
426'.
Field
'
7
421
Perimeter
Field
-
9
401
Comer
10 , ,
395 "
Comer..
STATISTICAL ANALYSIS•
Mean Failure Load: -
Sample Standard Deviation:
Min. Charasteristic Resistance Force:
409.30
Sr— 26.73
F'= 390.19
10735 SW 21611 St. Unit 416 Page 2 of 3 Tel: 305-256-4550
Miami FL 33170 www.FloridaTEC.net Fax: 305-256-6833
ROOF SKETCH:
FLORIDA TEC
PROVIDING SOLU77 igTHE ROOFING INDUSTRY
Roof Are
Grouni
Is
•
80'
5
s
6
•
10 $
! No 38'
3
7
�I -�, +-w� � d•� gyp/'
10735 SW 216th St. Unit 416 Page 3 of 3 Tel: 305-256-4550
Miami Fl.33170 www.FloridaTEC.net Fax: 305-256-6833
r I
FLORIDAI TEC
PROVIDING SOLUTIONS TO THEII� RoanNG/NDusr y
DATE: August 18, 2017
CoMPANYNAME: Tecta America
PRo1ECTADDREss: 4880 - 4882 N Kings Hwy, Fort Pierce
ASCE 7-10
Lab Report No. 127553E-4
C.A. # 30448
Lab Certificate # 17-0703.01
Input Parameters: Directional
Procedure A11
Heights Building (Ch 27
Part 1)
Basic Wind Speed(V) =
170.00 mph
Structural Category =
II
Exposure Category
= C
Natural Frequency =
N/A
Flexible Structure
= No
Importance Factor =
1.00
Kd Directional Factor
= 0.85
Alpha =
9.50
Zg
= 900.00
ft
At =
0.11
Bt
= 1.00
Am =
0.15
Bm
= 0.65
Cc =
0.20
1
= 500.00
ft
Epsilon =
0.20
Zmin
= 15.00
ft
Pitch of Roof =
0 : 12
Slope of Roof(Theta)
_ .00
Deg
h: Mean Roof Ht =
15.00 ft
Type of Roof
= FLAT
RHt: Ridge Ht =
15.00 ft
Eht: Eave Height
= 15.00
ft
OH: Roof Overhang at Eave=
.00 ft
Overhead Type
= No Overhang
Bldg Length Along Ridge =
80.00 ft
Bldg Width Across Ridge=
38.00
ft
Wind Pressure on Components and Cladding (Ch 30 Part 1)
All pressures shown are based upon ASO Design, with a Load Factor of .6
Width of Pressure Coefficient Zone "a" = = 3.80 ft
Description Width SPen Area Zone Max Min Maz P Min P
ft ft ft-2 GCp GOP Pee pef
-----------------------------------------------------------------------
Field 2.00 5.00 10.0 1 0.30 -1.00 15.37 -37.80
Perimeter 2.00 5.00 10.0 2 0.30 -1.80 15.37 -63.42
Corner 2.00 5.00 10.0 3 0.30 -2.80 15.37 -95.45
FASTENER SPACING CALCULATION
NOA: FL16730.R12
Fastener Spacing Calculated In Accordance WithRAS-137 Svstem'1WDe:LWC-41
f�I17 DesignPressuri,
:S24astener"
FVi',,
Deck•`Type +'
Elevated PressIoreZone
Fasteners Spacing
Sheet Width
(inch)
Field.
3Z80
6
114 ..
Pel eter.
63:42 '
10
42
95.45,
10
42
Since
Jorge G e7, P.E.
Lic. 0 42 1 11
Perimeter
Wrdth (inch)
_45.5
10735 SW 216'h St. Unit 416 Page 1 1 Tel: 305-256-4550
Miami FL33170 www.FloridaT Fax: 305-256-6833
EC.net