HomeMy WebLinkAboutREVIEW COMMENTSjG. lmci ' {/pLNlwl Planning & Development Services Building &Code Regulation Division 2300 Virginia Avenue Fort Plerce, FL 34982 Phone:(772)462-2172 Fex:(772)462.6443 PROPERTY INFORMATION Address: 4551 St Lucie Blvd City / State / Zip: Fort Pierce, FI 34946 Parcel#: 1431-120-0000-000/6 Zoning: IL APPLICATION INFORMATION Permit Number: 1711-0360 Permit Type: SLAB ONLY CONTRACTOR INFORMATION Contractor Name: Ronald H Foulks Business Name: R F Concrete Construction Inc Business Addr: 664 Old Dixie Hwy City / State / Zip: Vero Beach, FI 32962 REVIEWS AND COMMENTS Review Tvoe DOCUMENTS MISSING 11/14/2017 Comment: 11/14/2017 Comment: Comment: 11/14/2017 11/15/2017 Comment: Comment: 11/15/20W 11/1512017 Comment: ENGINEERING DEPARTMENT Comment: ENVIRONMENTAL REVIEW Comment: FIRE DEPARTMENT REVIEW Comment: FRONT COUNTER REVIEW Comment: SCANNED REVIEW COMMENTS BY ,t Lucie County 1 Owner(s): Maverick Boat Group Inc Jurisdiction: SAINT LUCIE COUNTY Lot#: Block: Stories- Automatic Sprinkler System? No Fax Number: 772-778-2142 Email: Terri@Rfcconstruction.Com Status Reviewed By Date Started Date Completed Date Released PENDING Lashahna Ingram FILLED LANDS AFFIDAVIT./I/30t/ RECORDED NOTICE OF COMMENCEMENT.✓///SO// / VEGETATION REMOVA OR EMPTION PERMIT AT TIME OF PICKUP. PLEASE SUBMIT APPLICATION AS SOON� . POSSIBLE.✓ �j3Fi//"% DRIVEWAY PERMIT APPLICATION. A COPY OF THE PAID UTILITY SERVICE RECEIPT FOR WATER AND SEWER FROM FPUA OR A LETTER FROM THE UTILITY SERVICES PROVIDER STATING SERVICES ARE AVAILABLE (ABILITY TO CONNECT AT THE SUBJECT LOCATION) A COPY OF THE PAID UTILITY SERVICE RECEIPT FOR ELECTRIC SERVICE OR A LETTER FROM THE ELECTRICAL UTILITY PROVIDER THAT ELECTRIC WILL BE AVAILABLE TO THE LOCATION. PENDING PENDING PENDING COMPLETE Lashahna Ingram 11/1412017 1111412017 1111412017 Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:(772)462-2172 FaX:(772)462-6443 REVIEW COMMENTS 2 PLANS EXAMINER ELECTRIC INCOMPLETE waver rnue ninmu If Comment: ELECTRICAL PLAN SHEETS EO.1—E5.1 ARE COMPLETE,O.K. TO DO SLAB WORK AND UNDER GROUND 11/22/2017 ELECTRICAL AND GROUNDING,BONDING OF STEEL,WALTER PRIDE SR. PLANS EXAMINER MECHANICAL INCOMPLETE Carl Peterson 1112112017 Comment: IS THERE ANY MECHANCIAL CHASES IN THE SLAB THERE IS NOTHING SHOWEN ON SLAB PLAN? 11/21/2017 PLANS EXAMINER PLUMBING INCOMPLETE Carl Peterson 1112112017 11121/2017 Comment: PLEASE CORRECTTHE FIXTURE COUNT WHEN THE OCCUPANT IS CORRECTED. Comment: PLEASE SHOW THE EYEWASH AND EMERGENCY SHOWER REQUIRED IN TABLE 403.1 MEETING THE STANDARDS ISEA Z358.1. IN 411 IF IT IS THE ONE INSIDE THE RESTROOM. IF IT IS NOT IN THE RESTROOM 11/21/2017 PLEASE SHOW THE LOCATION ON PLANS. EMERGENCY SHOWERS AND EYE WASHES SHOULD BE READIIYACCESIBLEAND NOT BEHIND CLOSED DOORS. Comment: PLEASE ADD FUTHER AREA SHOWEN ON PLANS PAGE A5 OF 61N THE OCCUPANT LOAD SO THE 11/2112017 FIXTURES WILL NOT HAVE TO BE ADDED IN THE FUTHER FOR A HIGHER OCCUPANT LOAD. Comment: PLEASE SHOW HOT WATER IN ACCORDANCE WITH 607.1 OF THE 2014 FLORIDA PLUMBING CODE. 11/27/2017 Comment: PLEASE SPECIFY HOW THE FLOR DRAIN TRAPS WILL BE SEALED OR PRIMED IN ACCORDANCE WITH 11/27/2017 1002.4 OF THE 2014 OF THE FLORIDA PLUMBING CODE PLANS EXAMINER REVIEW INCOMPLETE Ed Roseberry 1111712017 Comment: THIS IS AN F-1 FACTORY INDUSTRIAL OCCUPANCY CLASSIFICATION. AS SUCH, PER TABLE 1004.1.2, INDUSTRIAL AREAS, THE OCCUPANT LOAD SHOULD BE CALCULATED AT too SF/OCCUPANT. PLEASE 11/20/2017 ADJUST OCCUPANT LOAD, OR SUBMIT DETAILED RATIONAL ANALISYS TO BUILDING OFFICIAL, PER FBC 1004.1.2 EX., FOR APPROVAL USING A DESIGN OCCUPANT LOAD. ZONING REVIEW INCOMPLETE . Lydia Galbraith 11/14/2017 Comment: PLEASE PROVIDE4 SIGNED AND SEALED SETS OF CIVIL DRAWINGS 11/1412017 Comment: PLEASE PROVIDE 3 BOUNDARY SURVEYS WITH ALL ELEVATIONS IN NAVD 11/14/2017