HomeMy WebLinkAboutINSPECTION REPORTInspection Date: March 21, 2019 Saint Lucie County Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 SCANNED a pX BY ENG IN E R ING GROUP St. Lucie Countv Subject: Specjal l,�lnspect'on Report 1 of 1 (Final) [3C] Permit: SL17a11-0506 AT&T Site: Midway R FA#, 00489091 Site Address: 5690 Environment Drive, Fort Pierce, Saint Lucie County, FL 34981 APX Project: 17-0115.95 Dear Building Official: APX Engineering Group, LLC (APX) performed observations of the AT&T telecommunication facility located at the above -referenced site. The purpose of these observations was to inspect the following in accordance with the Florida Building Code, 5'h Edition (2014) and the National Electric Code (NEC), 2011 Edition: 1. Removal of nine existing antennas. 2. Removal of three existing Remote Radio Units (RRUs). 3. Removal of three existing antenna mounts. 4. Installation of nine proposed antennas. 5. Installation of nine proposed RRUs. 6. Installation of one proposed surge suppressor. 7. Installation of three proposed antenna mounts. 8. Installation of proposed power cables. 9. Installation of proposed fiber cables. 10. Installation of proposed grounding system. MAR 2 8 2019 Permitting Department St. Lucie County, FL The Installation of the above -mentioned items was visually inspected and compared with the approved construction drawings by APX Engineering Group, LLC dated January 5, 2018. Based on these observations and to the best of my knowledge and belief, the above -described construction of all structural load -bearing components complies with the permitted documents. Should you have any questions or wish to discuss any aspect of this letter, please do not hesitate to contact the undersigned. Michael A. Phillips, P.E. Chief Engineer Florida License #68312 zn Inspection Date: March 21, 2019 Saint Lucie County Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 s� a pA ENGIN'EERI NG •GROUP Subject: Special Inspection Report 1 of 1 (Final) [3C] Permit: SLC 1711.0506 AT&T Site: Midway Rd [FA# 100489091 Site Address: 5690 Environment Drive, Fort Pierce, Saint Lucie County, FL 34981 APX Project: 17-0115.95 Dear Building Official: APX Engineering Group, LLC (APX) performed observations of the AT&T telecommunication facility located at the above -referenced site. The purpose of these observations was to inspect the following in accordance with the Florida Building Code, 51h Edition (2014) and the National Electric Code (NEC), 2011 Edition: 1. Removal of nine existing antennas. 2. Removal of three existing Remote Radio Units (RRUs). 3. Removal of three existing antenna mounts. 4. Installation of nine proposed antennas. 5. Installation of nine proposed RRUs. 6. Installation of one proposed surge suppressor. 7. Installation of three proposed antenna mounts. 8. Installation of proposed power cables. 9. Installation of proposed fiber cables. 10. Installation of proposed grounding system. MAR 2 8 2019 Permitting Department St. Lucie County, FL The installation of the above -mentioned items was visually inspected and compared with the approved construction drawings by APX Engineering Group, LLC dated January 5, 2018. Based on these observations and to the best of my knowledge and belief, the above -described construction of all structural load -bearing components complies with the permitted documents. Should you have any questions or wish to discuss any aspect of this letter, please do not hesitate to contact the undersigned. Sincerely, APX Engineering Group, LLC Michael A. Phillips, P.E. Chief Engineer Florida License #68312 ° No O , g TE F .'AZ -o .c �p� �' O1VA 11„'G,°° November 16, 2017 Saint Lucie County SCANNED Planning & Development Services BY Building & Code Regulation Division St. Lucie County 2300 Virginia Avenue Fort Pierce, FL 34982 A a pA E N G IN E E R ING G R O UP Subject: Special Inspection Letter of Intent AT&T Site: Midway Rd [FA# 10048909] Site Address: 5690 Environment Drive, Fort Pierce, Saint Lucie County, FL 34981 APX Project: 17-0115.95 Dear Sir or Madam: APX Engineerin Group, LLC (APX) understands that the Ci ort Saint Lucie requires t a as s ecial . Inspec of for floe sublecf�consi-rifctivn:prot`e_c�f APX supplies specifications setting for a procedures to ibe taken for the req I -Inspec ions The purpose of these inspections will be to determine if the installation of the antenna equipment and antenna platform mount is in substantial accordance with the approved construction drawings prepared by APX dated November 16, 2017, Such special inspections will be performed in accordance with Section 110.10.1.1 of the Florida Building Code and will include, but not be limited to, the following: 1. Inspect anchoring, spacing and mounting of the proposed antennas to the existing tower structure. 2. Inspect mounting of proposed remote radio units (RRLIs) and proposed peripheral equipment to proposed antenna mounts and anchoring and spacing of proposed antenna mounts. Copies of the inspections shall be sent to the Building Department on a weekly basis, and the final letter of completion will be provided at the completion of the final inspection. This letter has been prepared for the purpose of fulfilling the requirements of the City of Port Saint Lucie with respect to the specific installation described. It is intended for the exclusive use of the City of Port Saint Lucie and AT&T. The information, assumptions and recommendations contained in this letter should not be used by others for any purpose without express written authorization from APX. Should you have any questions or wish to discuss any aspect of this letter, please do not hesitate to contact the undersigned. Sincerely, APX Engineering Group, LLC No Michael A. Phillips, P.E.F+��C��4 Chief Engineer Florida License #68312 A. EA a� OF 16 ( 4� 4LSV %' 38111ss' fj January 5, 2018 Saint Lucie County Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 MAR e 9 2018 SCANNED BY St. Lucie County ax E N GIN E E III N G G R O UP Subject: Special Inspection Letter of Intent AT&T Site: Midway Rd [FA# 10048909] Site Address: 5690 Environment Drive, Fort Pierce, Saint Lucie County, FL 34981 APX Project: 17-0115.95 Dear Sir or Madam: LE COPY APX Engineering Group, LLC (APX) understands that Saint Lucie County requires that, as special inspector for the subject construction project, APX supplies specifications setting forth the procedures to be taken for the required inspections. The purpose of these inspections will be to determine if the installation of the antenna equipment and antenna platform mount is in substantial accordance with the approved construction drawings prepared by APX dated January 5, 2018. Such special inspections will be performed in accordance with Section 110.10.1.1 of the Florida Building Code and will include, but not be limited to, the following: 1. Inspect anchoring, spacing and mounting of the proposed antennas to the existing tower structure. 2. Inspect mounting of proposed remote radio units (RRUs) and proposed peripheral equipment to proposed antenna mounts and anchoring and spacing of proposed antenna mounts. Copies of the inspections shall be sent to the Building Department on a weekly basis, and the final letter of completion will be provided at the completion of the final inspection. This letter has been prepared for the purpose of fulfilling the requirements of Saint Lucie County with respect to the specific installation described. It is intended for the exclusive use of Saint Lucie County and AT&T. The information, assumptions and recommendations contained in this letter should not be used by others for any purpose without express written authorization from APX. Should you have any questions or wish to discuss any aspect of this letter, please do not hesitate to contact the undersigned. Sincerely, APX Engineering Group, LLC Michael A. Phillips, P.E.-------- - Chief Engineer Florida License #68312