Loading...
HomeMy WebLinkAboutSTRUCTURAL ANALYSIS PAPPERaw August 31, 2017 Dennis Demarco MasTec Network Solutions, LLC 6100 Broken Sound Parkway, Suite 6 Boca Raton, FL 33487 SCANNED BY St. Lucie County Subject: Structural Analysis — Proposed Antenna Mounts [2C] AT&T Site: C-Indrio [FA# 100368331 Site Address: 4690 Emerson Avenue, Fort Pierce, FL 34951 APX Project: 17-0107.75 Dear Mr. Demarco: A ax E N GIN E E R ING G R O UP APX Engineering Group, LLC (APX) understands that you have requested a statement confirming that the proposed AT&T antenna mounts to be located at the above -referenced site can adequately support the proposed AT&T equipment loading configuration. This letter was based on published catalog information, and information provided by AT&T. It is our understanding that AT&T would like to support their proposed equipment with a new Connect -IT Wireless #LPPX14-12-3096-HD-PKBK-PHK heavy-duty platform mount. As indicated in the wind load calculations attached, the proposed antenna equipment loading will have its weight and projected area within the design parameters of the proposed mount. Therefore, based on our analysis, the proposed Connect -IT Wireless #LPPX14-12-3096-HD-PKBK-PHK platform antenna mount will support the proposed AT&T loading. Should you have any questions or wish to discuss any aspect of this letter, please do not hesitate to contact the undersigned. Sincerely, APX Engineering Group, LLC ,tea v; •�� 'ZF• No Gertha Wesh Michael A. Phillips, P.E. Junior Project Engineer Chief Engineer Florida License #68312 U x S T E OF QC 7 NA L Structural Evaluation na Mounting System Engineering Group, LLC I Lakeside Drive, #525, Miramar, FL 33027 Loading ®®®Appurtenance C�mml • - - ®KW rr rr .• MM �MEE I otal -- 164 45(JU AT&T C-Indrio (FA# 10036833) 17-0107.75 G.Wesh. August 2017 ) Page 1 of 1 Proposed Loading Sec. EL (ft.) City. Appurtenance Type A, Each (ft2) Total Wit (lbs) Each Total 3 CommScopeSBNHH-1D85A Panel 3.97 11.9 31.7 95.1 6 Kathrein/Scala 800-10121 Panel 3.9 23.4 46.3 278 3 Ericsson RRUS-11 Radio 2.1 6.3 54 162 A 3 Ericsson RRUS-32 Radio 2.29 6.86 50.6 152 B 102 3 Raycap DC6-48-60-18-8F squid OVP 3.18 9.53 20 60 C 6 RFS FDGW5504/3C-3 Dtplexer 1 6.02 2.9 17.4 6 RFS ATM19801712-0 TMA 1.83 11 19 114 NOT USED - 0 0 0 0 NOT USED - 0 0 0 0 NOT USED - 0 0 0 0 NOT USED - 0 0 0 0 NOT USED - 0 0 0 0 NOT USED - 0 0 0 0 NOT USED 0 0 0 0 NOT USED - 0 0 0 0 NOT USED - 0 0 0 0 NOT USED 0 0 0 0 NOT USED - 0 0 0 0 NOT USED - 0 0 0 0 NOT USED 0 0 0 0 NOT USED 0 0 0 0 Total = 64 764 REVISION STATUS OF SHEETS NOTES: 1. ALL STRUCTURAL STEEL SHALL CONFORM TO ASTM A36 GRADE. 2. ALL CONNECTIONS SHALL CONFORM TO AISC MANUAL OF STEEL CONSTRUCTION, ALL BOLTS SHALL BE A325-X; SIZE AS SHOWN ON DRAWING. ALL RODS SHALL BE ASTM A36; SIZE AS SHOWN ON DRAWING. 3. ALL STRUCTURAL STEEL SHALL BE FABRICATED TO FIT AT BOLTED CONNECTIONS WITHIN 1/16 INCH TOLERANCE. 4. STRUCTURAL STEEL SHALL NOT BE FLAME CUT UNDER ANY CIRCUMSTANCES WITHOUT APPROVAL OF THE ENGINEER. 5. ALL WELDING SHALL BE DONE BY AN AWS CERTIFIED WELDER AND IN COMPLIANCE WITH AWS DI.I. ALL WELD SIZES SHALL BE THE MAXIMUM ALLOWED BY THE MATERIAL BEING WELDED WITH 0.30 WIRE WIRE -WELD. 6. HOT DIP GALVANIZE ALL STRUCTURAL STEEL. TOUCH UP ALL FIELD WELDS AND ABRADED AREAS WITH TWO COATS OF GALVANIZED PAINT. 7. DO NOT EXCEED THE LOAD LIMIT SHOWN IN TABLE A (SHT3) OR TABLE B (SHT4). 8. LOAD MUST BE EVENLY DISTRIBUTED FOR LOAD & WIND RATING. 9. ALL 1/2" FASTENERS MUST BE TORQUED 50-60 FT: LBS. to. ALL 5/8" FASTENERS MUST BE TORQUED 100-120 FT: LBS. 11. ALL 3/4" FASTENERS MUST BE TORQUED 175-195 FT.-LBS. 12. SEE RM1030-3 DRAWING (1_13ENGO40A) FOR RING MOUNT INSTALL DETAILS. 13. SEE SCX3 DRAWING (L73ENGO2SA) FOR CROSSOVER PLATE INSTALL DETAILS. 14. SEE PHK14-12-HD DRAWING (L14ENGO21B) FOR HANDRAIL KIT INSTALL DETAILS. 15. A CONNECT -IT RM SERIES RING MOUNT IS READ. FOR LOAD & WIND RATING. 16. ANYONE WORKING OR STANDING ON THE PLATFORM MUST BE TETHERED TO THE TOWER ATALL TIMES. 17. AVERAGE ASSEMBLY WEIGHT 2,809 LBS. MAX PROJECTED ASSEMBLY AREA 6,415 SQ. IN. (EPAT). MAX. NORMAL PROJECTED ASSY AREA: 3,699 SQ. IN. (EPAN). FRANK ANDREW FORE, P.E. 42661 LIC. NO. SEAL 4 THIRD ANGLE PROJECTION DATE 717 PREPARED UNDER CONTRACT 1UPDATED NOTES 01/26/16 FAF 6ENG313 I I B I UPDATED NOTES I 05/09/ 6 I FAR 177 SUITE CONNECT -IT WIRELESS INI.: SUITE #310 TI TEOUESTA, FL 33469 � USA (561) 744-0510 2 DATE LPPS14-12-3096-HD-PKBK-PHK LOW =.E. 02-02-14 PROFILE PLATFORM MONO -POLE KIT ...... __ _ . .. SIZE DRAFTSMAN'. APPROVED BY: II C JOB NO: 14ENG022 CADFILENAME: llppS14-12-3096-hd-pkbk-phk.a4SHEEI CAGE CODE: I DWG NO: L14ENG022 J 0.048/1 4 3 2 1 D C e A - THIRD ANGLE FRANK ANDREW FORE, P.E. DATE \�4N�/ PREPARED UNDER 4256, FURNISHED UNDER LIC. NO. SEAL RENSIONS ' O C B A CNTNGE NO. IZONIRT1DESCRIPTION DATE /1PPROVED 16ENG293 16ENG313 A I B UPDATED NOTES UPDATED NOTES 01/26/16 05/09/16 PAP. 1 PAP. 2 1 2 1 1 1 1 1 1 72 1491 1 12N NUT- HEX, V2%13 NOTE 9 2 2 1 1 1 1 1 1 72 481 1 12SFW FLAT WASHER-1/2" 2 2 72 471 1 12LW LOCK WASHER- 1/2" 1 46 UB12-25-4.01 U-BOLT-1/2"-13x3x4" NOTE 2 1 1 1 45 UB12-254 U-BOLT KIT- 1/2"-13x3x4" NOTE 9 11 1 1 44 UB12-3-514.01 U-BOLT-1/2"-13x3x5-1/4" NOTE 2 121 1 1 43 UB12-3-514 U-BOLT KIT- 1/2"-130x5-1/4" NOTE 9 36 42 UBS12-35-514.01 SO U-BOLT- 1/2"-13x3-5-1/4" NOTE 9 2 41 58N NUT -HEX, 5/8"-11 NOTE 10 2 40 58SFW FLAT WASHER-5/8" 9 24 39 58NA NUT -HEX, 5/8"A1 NOTE 10 18 148 38 58FW FLAT WASHER-5/8" 2 9 24 37 58LW LOCK WASHER- 5/8" 24 36 58-212BA BOLT- 5/8"-11x2-1/2" NOTE 10 9 35 58E13A BOLT- 5/8"-11x6" NOTE 10 1 34 UBS58-578-75.01 SO U-BOLT-5/8%11x5.875x7.5" NOTE 10 6 33 UBS58-578-75 U-BOLT KIT- 5/8"-11x5.875x7.5" NOTE 10 12 18 32 34NA NUT -HEX, 3/4"-10 NOTE 11 12 18 31 34FW FLAT WASHER-314" 12 18 30 34LW LOCK WASHER-3/4" 6 9 21 GR34-24 ROD- 3/4"-10x24" NOTE 11 3 20 GP174-25 PIPE- V5 2-3/8" OD SCH 40 A36 GALV. STEEL 1 19 SCX2 CROSSOVER PLATE A36 GALV. STEEL 12 1 118 1 COP2-25 CROSSOVER PLATE KIT VARIOUS 3 1 117 HCP HANDRAIL CORNER PC A36 GALV. STEEL 1 16 PHK14-12-HD PLATFORM HANDRAIL KIT VARIOUS NOTE 14 12 15 GP96-30 PIPE- 0 2-7/8"ODx96" SCH 40 A36 GALV. STEEL 12 14 SCX3 CROSSOVER PLATE A36 GALV. STEEL NOTE 13 3 13 KM-SP PIPE- 1" O.D. SCH. 40 A36 GALV. STEEL 6 12 KM -A KICKERANGLE A36 GALV. STEEL 12 11 KM-TS TOP MOUNT SPACER A36 GALV. STEEL 3 10 KM-TP TOP MOUNT ASSY VARIOUS 3 9 KM -BM BOTTOM MOUNT ASSY VARIOUS 1 8 PKBK PLATFORM KICKER KIT VARIOUS 3 7 ST14-35-168 SO TUBE- 1/4"x3-1/2"x168" A36 GALV. STEEL 6 LPP14-2.01 PLATFORM SUB-ASSY VARIOUS 5 RM1030.01 RING MOUNT SUB-ASSY VARIOUS f3318 4 RM1030 RING MOUNT ASSY VARIOUS UPPER 113 3 RM1030-3.01 HD RING MOUNT SUB-ASSY VARIOUS 2 RM1030-3 HD RING MOUNT ASSY VARIOUS LOWER 1 LPPS14-12-96-HD-PKBK-PHK PLATFORM ASSY VARIOUS NOTE 7.8,16 45 UNITS/ASSY 0 A :IND N ON PART OR IDENTIFYING NO. NOMENCLATURE MATERIAL SPECIFICATIONS OR REMARKS CAD RECTS PARTS LIST PROJECTION 177 U.S. HIGHWAY SUITE IFL ENONEEx6NU TECA(561) FL 33469 ANALYSES 6 SOLUTIONS USA (561) 744-0510 ........ CONNECT -IT WIRELESS IN(? I LPP814-12-3096-HD-PKBK-PHK LOW PROFILE PLATFORM MONO -POLE KIT ENGINEER DATE DESIGN ENGINEER: F.A. FORE P.E. 02-02-14 CONTRACT STRUCTURES ENGINEER: F.A. FOREP.E. 02-04-14 SIZE c CAGE CODE: DWG NO: L14ENG022 J DRAFTSMAN: CONTRACT APPROVED BY: JOB NO: 14ENG022 CADFILENAME: Appsl 4I2-309G­hd-pkbk-phkS.iII SHEET: 20f12 REVISION: B SCALE: WA 4 3 2 1 AT&T MOUNT DESIGN CRITERIA AND PARAMETERS: Load rating determined in accordance with: TIA-EIA-222-G4 A.S.C.E. 7-10 BASIC WIND SPEED WITHOUT ICE, V. (See Table A) BASIC WIND SPEED WITH ICE, VI: (See Table A) DESIGN ICE THICKNESS, t 0", 0.5 & 1.0" WIND DIRECTION FACTOR, Kd: 0.95 RISK CATEGORY: II STRUCTURE CLASS: II IMPORTANCE FACTOR, I: 1.00 MOUNT & ANTENNA CL: 300' AGL EXPOSURE CATEGORY: C VELOCITY PRESSURE COEFFICIENT, KZ 0.85 A UPDATED NOTES 1/26/16 PAP. 16ENG3 33 I I B I UPDATED NOTES I 05/09/ 6 I FAR TOPOGRAPHIC CATEGORY: 1 TOPOGRAPHIC FACTOR, Kzt: 1.0 GUST EFFECT FACTOR, Gh: 1.00 1. AT&T load limits are calculated with four (Heavy-5 and Heavy-10) or Five (WILL only) symmetrically arranged mount pipes located across the front face of the mount. 2. (EPA)N is the total combined effective projected area of the normal (front) face of the antenna, mount pipe, radio and any other appurtenance attached to themount pipe. 3. (EPA)T is the total combined effective projected area of the transverse (side) face of the antenna, mount pipe, radio and any other appurtenance attached to the mount pipe. 4. FACTORED WEIGHT is the factored vertical down load due to total combined factored weight of antenna, radio, and all other appurtenance attached to the mount pipe for bare and iced conditions. 5. Factored ice thickness was applied to all mount members and is included in the EPA and factored vertical down loads shown in the table. 6. The EPA's & Factored Weights shown in the table For the Iced Condition are based on escalated ice thickness. 7. The EPA's & Factored Weights shown in the table apply at each mount pipe location. 8. The design wind force was determined in accordance with 2.6.9. 9. Mount is also designed for maintenance conditions using the following parameter changes: 40 mph, 3-second gust Basic Wind Speed for bare condition. EPA's and Factored Weights as noted for the Bare Condition in the mount classification table. A nominal (unfactored) live load of 500 lbs. at the worst case mount pipe location. A nominal (unfactored) live load of 250 Ibs. at the worst case location of horizontal members, excluding the tieback. TABLE A- AT&T MOUNT DESIGN CRITERIA AND CLASSIFICATIONS Bare Condition Iced Condition Mount Classification Basic Wind S eed (MPH) P (EPA) N (s . R) (EPA) T (s . R) actor¢ Wei ht 0 Basic Wind Speed (MPH) P Desi n Ice Thickness (EPA)N (s . R) (EPA)T (s . ft.) actor¢ Weight t@O' AGL t. @300' AGL Heavy-5 90 15.0 11.0 111 50 0.50" 1.15" 19.1 19.5 750 Heavy-10 120 15.0 15.0 663 60 1.00° 2.49" 24.0 29.0 1,325 Heavy-WLL 120 1 17.5 175 1 530 6o 1.00" 2.49" 1 24.0 24.0 1,060 FRANKANDREW FORE, P.E. DATE 42561 LIC. NO. SEAL THIRD ANGLE PROJECTION 1 177 U.S. HIGHWAY 1 tm SUITE 9310 7T7ENGMERING TEOUESTA, FL 33469 .. ANALYSES dSOLUTIONS USA (561)744-0510 DESIGN ENGINEER: F.A. FORE,P.E. 02-02-14 STRUCTURESENGINEER; F A. FORE PE 02-04-14 iOVEO BV: NO: 14ENG022 CAD FILE NAME: CONNECT -IT WIRELESS, I LPPS14-12-3096-HD-PKBK-PHK LOW PROFILE PLATFORM MONO -POLE KIT SIZE CAGE CODE: DWG NO: C L1 SCALE: 4 FBC 2014 MOUNT DESIGN CRITERIA AND PARAMETERS: Load rating determined in accordance with: TIA-EIA-222-G-4 A.S.C.E. 7-10 FLORIDA BUILDING CODE 2014 BASIC WIND SPEED WITHOUT ICE, V: 181 MPH (&T) or 140 MPH (VASD) DESIGN ICE THICKNESS, t 0" WIND DIRECTION FACTOR, Kd: 0.85 RISK CATEGORY: II STRUCTURE CLASS: II IMPORTANCE FACTOR, I: 1.00 MOUNT & ANTENNA CL: 150' AGL EXPOSURE CATEGORY: C VELOCITY PRESSURE COEFFICIENT, KZ 0.85 1A UPDATED NOTES 1/26/16 FAR 6ENG3 33 I I B I UPDATED NOTES I 05/09/ 6 I FAR TOPOGRAPHIC CATEGORY: 1 TOPOGRAPHIC FACTOR, Kzt: 1.0 GUST EFFECT FACTOR, Gh: 0.85 1. FBC 2014 load limits are calculated with 3, 4, or 5 symmetrically arranged mount pipes located across the Front face of the mount. 2. (EPA)N is the total combined effective projected area of the normal (front) face of the antenna, mount pipe, radio and any other appurtenance attached to the mount pipe. 3. (EPA)T is the total combined effective projected area of the transverse (side) face of the antenna, mount pipe, radio and any other appurtenance attached to the mount pipe. 4. FACTORED WEIGHT is the factored vertical down load due to total combined factored weight of antenna, radio, and all other appurtenance attached to the mount pipe for bare and iced conditions. 5. Factored ice thickness was assumed O" in the EPA and factored vertical down loads shown in the table. 6. The EPA's & Factored Weights shown in the table for the Iced Condition are based on O" escalated ice thickness. 7. The EPA's & Factored Weights shown in the table apply at each mount pipe location. 8.The design wind force was determined in accordance with 2.6.9. 9. Mount walso designed for maintenance conditions using the following parameter changes: 40 mph, 3-second gust Basic Wind Speed for bare condition. EPA's and Factored Weights as noted for the Bare Condition in the mount classification table. A nominal (unfactored) live load of 500 lbs. at the worst case mount pipe location. A nominal (unfactored) live load of 250 lbs. at the worst case location of horizontal members,excluding the tieback. FRANK ANDREW FORE, P.E. DATE 42561 LIC. NO. SEAL TABLE B- FLORIDA CODE SPECIFIC HIGH WIND MOUNT DESIGN CRITERIA Max. Combined Factored Weight Per Sector. 1,500 lbs. Max. Combined Factored Load Force (P'A) Per Sector. 3,640 Ibz Max Combined EPA at 181 MPH (V ) OR 14O MPH IVA,); 7,850 sq.-in. Max. Combined EPA at 194 MPH (V ) OR 150 MPH IVA,): 6,830 sq.-in. THIRD --ANGLE PROJECTION `F� 177 U.S. HIGHWAY I EN TEQUE SUITE 3 33469 10 1 NALYSE36 SOLUTIONS USA 744-0510 "p CONNECT -IT WIRELESS, INI..: LPPS14-12-3096-HD-PKBK-PHK LOW PROFILE PLATFORM MONO -POLE KIT ENGINEER DATE DESIGN ENGINEER: F.A. FORE P.E. 02-02-14 PREPARED UNDER CONTRACT STRUCTURES ENGINEER: F.A. FORE P. E. 02-04-14 SIZE C CAGE CODE: DWG NO: L14ENG022 J DRAFTSMAN: FURNISHED UNDER CONTRACT APPROVED BY: JOB NO: 14ENG022 CADFILENAME: 9PP3W2-309S­hd-pkbk-pM as4i SHEET: 40112 REVISION: B I SCALE: WA 4