Loading...
HomeMy WebLinkAboutMISC LETTERAtlantis 1 Condominium 140102 S. Ocean Drive Jensen Beach, FL 34957 Hurricane Irma damaged the mansard on the face of the exterior wall of the building. The scope of work for this project will only include removing the damaged mansard and extending the stucco to the top of the wall. This modification only has been designed in accordance with the requirements of the 2014 Florida Building Code, Fifth Edition — Residential, Chapter 3, Section R301.2.1. The following wind load requirements, in accordance with the 2014 Florida Building Code, Fifth Edition — Building, Chapter 16, Structural Design, Section 1609 and ASCE 7-10 were employed in the design of the structure: Ultimate Design Wind Speed (V u): 164 MPH (3-Second Gust) Nominal Design Wind Speed (Vmd): 127.03 MPH (3-Second Gust) Risk Category: II Wind Exposure Category: "D" Applicable Internal Pressure Coefficient: +/- 0.18 Design Pressure for Exterior Components & Cladding: • Walls: N/A (Roof is Existing) • Roof: N/A (Wall is Existing) Type of Roof System: Existing. Materials: Existing. Fastening Requirements: Existing. Flashing Requirements: Existing. SCANNED BY St. Lucie County DAvis & CLEATON ENGINEERING, INC. 260 WEKIVA SPRINGS ROAD, SUITE 1060 LONGWOOD, FL 32779 PHONE#:407-539-2353 Lic.#35816 40% i♦s ��ii r