HomeMy WebLinkAboutMISC LETTERAtlantis 1 Condominium
140102 S. Ocean Drive
Jensen Beach, FL 34957
Hurricane Irma damaged the mansard on the face of the exterior wall of the building.
The scope of work for this project will only include removing the damaged mansard and
extending the stucco to the top of the wall. This modification only has been designed in
accordance with the requirements of the 2014 Florida Building Code, Fifth Edition —
Residential, Chapter 3, Section R301.2.1. The following wind load requirements, in
accordance with the 2014 Florida Building Code, Fifth Edition — Building, Chapter 16,
Structural Design, Section 1609 and ASCE 7-10 were employed in the design of the
structure:
Ultimate Design Wind Speed (V u): 164 MPH (3-Second Gust)
Nominal Design Wind Speed (Vmd): 127.03 MPH (3-Second Gust)
Risk Category: II
Wind Exposure Category: "D"
Applicable Internal Pressure Coefficient: +/- 0.18
Design Pressure for Exterior Components & Cladding:
• Walls: N/A (Roof is Existing)
• Roof: N/A (Wall is Existing)
Type of Roof System: Existing.
Materials: Existing.
Fastening Requirements: Existing.
Flashing Requirements: Existing.
SCANNED
BY
St. Lucie County
DAvis & CLEATON ENGINEERING, INC.
260 WEKIVA SPRINGS ROAD, SUITE 1060
LONGWOOD, FL 32779
PHONE#:407-539-2353 Lic.#35816
40% i♦s ��ii r