Loading...
HomeMy WebLinkAboutFL DEPT OF E.P.SCANNED FLORIDA DEPARTMENT OF ENVIRONMENTAL PROTECTION BY Division of Water Resource Management St. Lucie County Coastal Construction Control Line Program 2600 Blair Stone Road, M.S. 3522 Tallahassee, FL 32399-2400 Permit No. -8033373 _ SL Phone: (850) 245-8336 No. of Pages Attached: 8 FIELD PERMIT PURSUANT TO SECTION 161.053 OR 161.052, FLORIDA STATUTES FINDINGS OF FACT AND CONCLUSION OF LAW: The request for a field permit was considered by the staff designee of the Department of Environmental Protection and found to be in compliance with the requirements of Chapter 62B-33, Florida Administrative Code(F.A.C.). Approval is specifically limited to the activity in the stated location and by the project description, approved plans (if any), attached standard conditions, and any special conditions stated below pursuant to Paragraph 161.053(5), Florida Statutes (F.S.). This permit maybe suspended or revoked in accordance with Section 62-4.100, F.A.C. PROJECT LOCATION: N0070/N0570 of DEP R-21 3880 N. AIA (Hibiscus by the Sea Condominium Association, Inc) Fort Pierce"'IL"'OP - PROJECT DESCRIPTION: As per attached plan, may extend dune walkover seaward and ramp down to grade. Seaward extension and re -configuration is not to exceed multi -residential dune walkover guideline maximums (6'wide, 6" posts, no further than 10' seaward of vegetation, no concrete). Page] of4 DEP form 73-122 (Updated 5/05) xrrrit No.-8033373 SL SPECIAL PERMIT CONDITIONS: The permit is valid only after all applicable federal, state, and local permits are obtained and does not authorize contravention of local setback requirements or zoning or building codes. Ibis permit and public notice shall be posted on the site immediately upon issuance and shall remain posted along with local approval until the completion of any activity authorized by this permit. Other special conditions of this permit include: Standard field permit conditions and dune walkover guidelines prevail, no lighting is authorized. No additions or modifications w/o prior DEP approval. No work authorized during marine turtle nesting season (3/1 through 10/31). For additional seaward encroachment, the existing 9Vx steps are to be removed and allowed to re -vegetate with native dune vegetation. STANDARD PERMIT CONDITIONS: The pemtittee shall comply with the attached standard field permit conditions. APPLICANT INFORMATION: I hereby certify that I am either. (la) the owner of the subject property or (lb) I have the owner's consent to secure this permit on the owner's behalf, and that (2)1 shall obtain any applicable licenses or permits which may be required by federal, state, county, or municipal law prior to commencement of the authorized work; (X acknowledge that the authorized work is what I requested and (4)1 accept responsibility for compliance with all permit conditions. Applicant's Applicant's Printed e/ N If applicant is an agent: See above ,rye 4R2r1e% (—) Printed time ofproperty owner Property owner's address Property owner's telephone no. DEPARTMENT FINAL ACTION AND FILING AND ACKNOWLEDGMENT: This field permit is approved on behalfofthe Department of Environmental Protection by the undersigned staff designee, and filed on this date, pursuant to section 120.52, F.S., with the undersigned designated Deputy Clerk, receipt of which is hereby 7rd g. [Jason M. SDanier t 08/30/2018 EXPIRATION DATE: 02/28/2019 (Emergency permits issued pursuant to Section 62B-33.014, F.A.C., are valid for no more than ninety days and other field permits are valid for no more than 12 months. Thestaffdesignee may specify a shortertime limit) EMERGENCY PERMIT: YES Z NO Approved plans are attached: ZYES ❑ NO Page 2 of 4 DEP form 73-122 (Updated 5105) mnit No.-8033373 SL POST PERMIT AND PUBLIC NOTICE CONSPICUOUSLY ON THE SITE PUBLIC NOTICE The foregoing constitutes final agency action. Any person whose substantial interests are affected by any decision made by the Department on the Field Permit has a right to request an administrative hearing in accordance with the provisions of Sections 120.569 and 120.57, F.S. The request for an administrative hearing must comply with the provisions of Rule 28-106.201, F.A.C., and must be received by the Department (at the address given below) within twenty-one (21) days from the date of this notice. When the Department receives an adequate and timely filed request for hearing, the Department will request the assignment of an administrative law judge. Once the administrative law judge is requested, the Division of Administrative Hearings will have jurisdiction over the formal proceeding and the Department (as the referring agency) will take no further action with respect to the proceeding except as a party litigant. Section 120.54(5)(b)4, F.S., and Rule 28-106.201(2), F.A.C., explain that the following items must be included in a petition for a formal administrative hearing (a) The name and address of each agency affected and each agency's file or identification number, if known; (b) The name, address, any e-mail address, any facsimile number, and telephone number of the petitioner, if the petitioner is not represented by an attorney or a qualified representative; the name, address, and telephone number of the petitioner's representative, if any, which shall be the address for service purposes during the course of the proceedings; and an explanation of how the petitioner's substantial interests will be affected by the agency determination; (c) A statement of when and how the petitioner received notice of the agency decision; (d) A statement of all issues of material fact disputed by the petitioner, or a statement that there are no disputed facts; (e) A concise statement of the ultimate facts alleged, including a statement of the specific facts that the petitioner contends warrant reversal or modification of the Department's action; (f) A statement of the specific rules or statutes the petitioner contends require reversal or modification of the Department's action, including an explanation of how the alleged facts relate to the specific rules or statutes; and (g) A statement of the relief sought by the petitioner, stating precisely the action that the petitioner wants the Department to take with respect to its action. A person may request an extension of time to petition for an administrative hearing. The person filing the request for extension must do so within the time limits for filing a petition described above. The request must state why an extension of time is needed. The Department will grant an extension only when good cause is shown. If a petition or a request for time extension is filed, further order of the Department becomes necessary to effectuate this Field Permit. Accordingly, the Department's final action may be different from the position taken in this notice. Actions undertaken by any person under this permit, pending the lapse of time allowed for the filing of such a request for hearing, may be subject to modification, removal, or restoration. Failure to petition within the allowed time frame constitutes waiver of any right that a person has to request a hearing under Section 120.57, F.S., and to participate as a party to the proceeding. If a legally sufficient petition for hearing is not timely received, this notice constitutes final agency action. When this order becomes final and is filed with the Department Clerk, any party to the order has the right to seek judicial review under Section 120.57, F.S., and Rule 9.030(b)l(c) and 9.110, Florida Rules of Appellate Procedure. A notice of appeal must be filed within thirty (30) days with both the Department Clerk (see address below) and with the appropriate district court of appeal. The notice filed with the district court must be accompanied by the filing fee specified in Section 35.33(3), F.S. Any subsequent intervention will be only by the approval of the presiding officer on motion filed under Rules 28-5.207 or 60Q-2.010, F.A.C. All requests for hearings are to be filed with the Department at the following address: Florida Department of Environmental Protection Office of General Counsel Department Clerk 3900 Commonwealth Boulevard Mail Station 35 Tallahassee, Florida 32399-3000 Page 3 of 4 DEP form 73-122 (Updated 5105) M Permit No.-8033373 _ SL STANDARD FIELD PERMIT CONDTTIONS The following conditions shall apply to FIELD PERMrrs (unless waived by DEP or modified by special permit condition). In the event of a conflict between a field permit condition and a special permit condition, the special condition shall prevail. 1) The permittee shall carry out the construction or activity for which the permit was granted in accordance with the plans and specifications that were approved by DEP as part of the permit. Any deviation there from shall be grounds for suspension of the work and revocation of the permit pursuant to Section 120.60(7), F.S., and may result in assessment of civil fines or issuance of an order to alter or remove the unauthorized structure, or both. No other construction or activities shall be conducted. No modifications to project size, location, or structural design are authorized. A copy of the permit shall be conspicuously displayed at the project site. 2) The permittee shall conduct the construction or activity authorized under the permit using extreme care to prevent any adverse impacts to the beach and dune system, marine turtles and their nests and habitats, or adjacent property and structures. 3) The pemuttee shall allow any duly authorized member of the staff to enter upon the premises associated with the project authorized by the permit for the purpose of ascertaining compliance with the terms of the permit and with the rules of DEP, until all construction or activities authorized or required in the permit have been completed and the project accepted by DEP. 4) The permittee shall hold and save the State of Florida, DEP, its officers and employees, harmless from any damage (no matter how occasioned and no matter what the amount) to persons or property that might result from the construction or activity authorized under the permit and from any and all claims and judgments resulting from such damage. 5) The permittee shall allow DEP to use all submitted records, notes, monitoring data, and other information relating to construction or any activity under the permit for any purpose it may deem necessary or convenient, except where such use is otherwise specifically forbidden by law. 6) Construction traffic shall not operate and building materials shall not be stored on vegetated areas seaward of the control line, unless specifically authorized by the permit. If (in the opinion of DEP staff) this requirement is not being met, positive control measures shall be provided by the permittee at the direction of DEP staff. Such measures may include temporary fencing, designated access roads, adjustment of construction sequence, or other requirements. 7) The permittee shall not disturb existing beach and dune topography and vegetation except as expressly authorized in the permit. Before the project is considered complete, any disturbed topography or vegetation shall be restored (as prescribed in the permit) with suitable fill material or revegeaated with appropriate beach and dune vegetation. 8) The fill material shall be obtained from a source landward of the control line and shall consist of sand which is similar to that already on the site in both grain size and coloration. This fill material shall be free of construction debris, rocks, or other foreign matter. A sample of the sand shall be provided to the staff representative of the Bureau of Beaches and Coastal Systems during the preconstmction conference. 9) If surplus sand fill results from any approved excavation seaward of the CCCL, such material shall be distributed seaward of the CCCL on the site, as directed by DEP staff (unless otherwise specifically authorized by the permit). 10) Any native salt -resistant vegetation destroyed during construction shall be replaced with plants of the same species or, by authorization of DEP, with other native salt -resistant vegetation suitable for beach and dune stabilization. Unless otherwise specifically authorized by the staff, all plants installed in beach and coastal areas (whether to replace vegetation displaced, damaged, or destroyed during construction or otherwise) shall be of species indigenous to Florida beaches and dunes (i.e., sea oats, sea grape, saw palmetto, panic grass, salt meadow hay cord grass, seashore salt grass, and railroad vine). 11) All topographic restoration and revegetation work is subject to approval and acceptance by DEP staff. 12) If not specifically authorized elsewhere in this permit, no operation, transportation, or storage of equipment or materials is authorized seaward of the dune crest or rigid coastal structure during the marine turtle -nesting season. The marine turtle -nesting season is May 1 through October 31 in all counties (except Brevard, Indian River, St. Lucie, Martin, Palm Beach and Broward counties where marine turtle nesting occurs during the period of March 1 through October 31). 13) If not specifically authorized elsewhere in this permit, no temporary lighting of the construction. area is authorized at any time during the marine turtle -nesting season and no additional permanent exterior lighting is authorized. 14) This permit has been issued to a specified property owner and is not valid for any other person. Page 4 of 4 DEP farm 73-122 (Updated 5105) T- 50'RAMP ADDITION SLOPE 8:1 10.5' TOCONDOMMII+X�INIUM Z 1 5' STAIRS TO BEACH TO BE REMOVED SHOWER AREA "'NOTES'- - PROPOSED WORK IS TO CONSTRUCTA 5' X 50' RAMP ADDITION TO EXISTING BOARDWALK, REMOVE EXISTING STEPS, AND REPLACE RAIL CAP ON EXISTING PLATFORM WITH P.T. 2" X 12' -ALL NEW HARDWARE TO BE SS AND ALL LUMBER TO BE P.T. -ALL NEW POSTS TO BE 6" X 6' P.T. POSTS (0.80 CCA TREATED MIN.) - MIN. PENETRATION INTO SAND VARIES 4' TO 6' OR AS NECESSARY TO PROVIDE ADEQUATE BEARING STABILITY - DECK DESIGN LOADS TO MEET 2014 FBC: WIND LOAD AS PER ANSIIASCE 7-10 SPEED= 170 MPH EXPOSURE = D IMPORTANCE FACTOR=1.0 Environmental ►S ervices, Inc. 1901 SW Yellowtail Avenue Port Saint Lucie, FL 34963 Phone: 772-216-3997 Fax: 772-679-4520 www.disenvironmentalserAces.com Hibiscus by the Sea Condominium Association, Inc. 3880 N A1A Fort Pierce, Florida PIN# 1423-805-0000-0003 1" = 40' 4� N 01- 20' ' 0' GRAPHIC SCALE Paul Welch, Inc. 1984 SW Biltmore Street, #114 Port St. Lucie, FL 34964 Paul Welch, PE No. 29945 JAN 2017 1 SHEET 1 of 4 0 SLOPE 10.6 88' 5' TO CONDOMINIUM ZA 4� N S LANDING S LANDING s _ EXISTING 9' X4' STAIRS TO BEACH TO BE REMOVED — EXISTING SHOWERAREATO REMAIN .•NO 29945 • , ep: C -01 STATE OF .,Z i T`�AN .'�/a m0c4'�ORIDp os�aSlBONq n EN�� `vea —NOTES— - PROPOSED WORK IS TO CONSTRUCTA 5' X V RAMP AD O EXISTING BOARDWALK REMOVE EXISTING STEPS, -,.eQ�$E�L,A„ Qua PL7C�F�Af IT P.T. T X 12' BOARDWALK R4MP IS N N ACCESS %ALCNEW HARDWARE T08ESSA AL LUMBERTOBEP.T. - ALL NEW POSTS TO BE B' X 8' P.T. POSTS (0.80 CCA TREATED MIN.) - MIN. PENETRATION INTO SAND VARIES 4'TO8'OR AS NECESSARY TO PROVIDE ADEQUATE BEARING ST siur1' - DECK DESIGN LOADS TO MEET 2014 FBC: 0' 20' 40' WIND LOAD AS PERANSIASCE 7-10 SPEED =170 MPH EXPOSURE= ❑ GRAPHIC SCALE IMPORTANCE FACTOR=1.0 BOARDWALK RAMP ADDITION Paul Welch, Inc. Environmental PLAN VIEW 1984 SW Biltmore Street1,1� 4 Hibiscus by the Sea Port St Lucie, FL 34984 Inc. Services, Condominium Association, Inc. 1901 SW Yellowtail Avenue 3880 N A1A JAN 2 2018 Port Saint Lucie, FL 34953 Fort Pierce, Florida Paul Welch, PE No. 29945 Phone: 772-2164997 Fax: 772-879-0520 PIN# 1423-805-0000-0003 1vww.dlsenvironmentalserliices.com $f^IF , JAN 2017 1 —40 REVISED JAN 2018 SHEET 1 of 1-12 O GRASPABLE HAND RAIL OFFSET FROM T X e' WITH BRACKETS 2' X 8- VERTICAL RAIL crop RAIL) —TOP VIEW 2-X 2- PICKETS _J 4. O.C. (IYP) T X 12' P.T. CROwnES J 6' X 6- P.T. POSTS (ABOVE DECK) SPACING VARIES 4'-10. O.C. (TYP.) 2'X 8' P.T. STRINGERS 18' O.C. (MAX) (2) 518- SS THRU BOLTS —J "P) PER POST 4' X 6'P.T. DECKING —NOTES' - NEW POSTS TO BE 6' X 8' P.T. POSTS (0.80 CCA TREATED MIN.) -6' MIN. PENETRATION FOR ALL POSTS GREATER THAN T EXPOSED HEIGHT -4' MIN. PENETRATION FOR ALL POSTS WITH T OR LESS EXPOSED HEIGHT - 2' X 2' PICK0=T5 NOT ALL SHOWN FOR CLARITY -ALL HARDWARETO BE SS AND ALL LUMBER TO BE P.T. 9 Jr-dnvironmental Services, Inc. 1901 SW Y011owtail Avenuo Port Saint Lucie, FL 34953 Phone: 772-2153997 Fax:772-879-0520 www.disonvironmentalsemices.com WITH (2) #14 SS SCREWS PER POST Hibiscus by the Sea Condominium Association, Inc. 3880 N A1A Fort Pierce, Florida swE 1 =10, QPU1 C..w6 C E NO 29945 0_ 5' . 10, GRAPHIC SCALE Paul Welch, Inc' 1984 SW Biltmore Street, t 1.1.4_ Port St. Lucie, FL 34984 J AN 252018 Paul Welch, PE No. 29945 JAN2017 SHEET2of4 SED JAN 2018 6' X a' (A( 2' X 6' P.T. I 21X a, P.T. 24' (2) 518' SS TH (TYP) 2'X 12' P.T. CI —NOTES- - ALL NEW POSTS TO BE a' X e' P.T. POSTS (0.80 CCA TREATED MIN.) - MIN. PENETRATION INTO SAND VARIES 4' TO 6' OR AS NECESSARYTO PROVIDE ADEQUATE BEARING STABILITY -ALL HARDWARETO BE SS OR HDG AND ALL LUMBER TO BE P.T. -2' X 6' P.T. DECKING NOT ALL SHOWN FOR CLARITY -DECKINGWILLBEATTACHEDWRH 9105SDECKSCREWX3' Environmental q_S RAMP'PLAN VIEW DETAIL TT S Hibiscus by the Sea ervices, 1nC. Condominium Association, Inc. 1901 SW Yellowtail Avenue 3880 N A1A Port Saint Lucie, FL 34963 Fort Pierce, Florida Phone: 772-216-3997 Fax: 772-8794520 PIN#1423-805-0000-0003 w Alsenvironmentalservices.com sr 1"=3' VARIES -1w O.C. ee`oesQPJ ..... NO 29945 •'�[!� m9 �. STATE OF •toe 0' A P,•�ee �O�� R\peee ss `O N Aj6�10`e� 0' 1.5' 3' ;fk. GRAPHIC SCALE Paul Welch, Inc. 1984 SW Biltmore Street, 14- Port St. Lucie, FL 34984 JAN252018 1 Paul Wetch, PE No. 29945 JAN 2017 SHEET 3 of 4 SED JAN 2018 2' X 8' P.T. RAIL GAP 2' X 8' P.T. TOP RAIL AND 2° X 6' P.T. BOTTOM RAIL WRH 2'X 2' PICKETS 4' O.C. T('P. BOTTOM RAILAT DECK LEVEL PROVIDE EDGE PROTECTION (2).SW SSTHRU' :fb77 T X 6' PS. DECKING - 8' X 8' P.T. POSTS (ABOVE DECK) 2' X 8' P.T. STRINGERS _ 24' O.C. (MAX) 2' X 12' P.T. CROS&TIES —NOTES- - NEW POSTS TO BE B' X 6' P.T. POSTS (0.80 CCA TREATED - 8' MIN. PENETRATION FOR ALL POSTS GREATER THAN T t - 4' MIN. PENETRATION FOR ALL POSTS WITH 7' OR LESS E) -ALL HARDWARETO BE SS AND ALL LUMBER TO BE P.T. DECKIN F,-�T,Jg{;)i !(11� �p1gf4UgRM iVLS ANDGUAR-❑ ILSMEETTH REQUIREMENTS t FBC 1707.8.1 FOR 50PLF AND 2000 CONCENTRATED LOA q Environmental Services, Inc. 1901 SW Yellowtail Avenue Port Saint Lucie, FL 34953 Phone: 772-2153997 Fax: 772-8794520 www.disenvironmentaisemices.com 5' - w1 EXISTING GRADE ) HEIGHT HEIGHT RAMP CROSS SECTION . VIEW DETAIL -Hibiscus by the Sea - Condominium Association, Inc. 3880 N A1A Fort Pierce, Florida PIN# 1423-805-0000-0003 sruE 1"=2' • VARIES ®e116tHB iA98®QOe eeee``4`U` C- ......... Q�Z i No e * . 29945 a �'. STATE OF 0' 1' . 2' GRAPHIC SCALE Paul Welch, Inc. 1984 SW Biitmore Street, Port St. Lucie, FL 34984 JAN 2017 SHEET 4 of 4 REVISED JAN 2018 FLORIDA DEPARTMENT OF ENVIRONMENTAL PROTECTION Division of Water Resource Management Coastal Construction Control Line Progmm 2600 Blair Stone Road, M.S. 3522 Tallahassee, FL 32399-2400 Permit No. -8033373 _ SL Phone: (850) 245-8336 No. of Pages Attached: 8 FIELD PERMIT PURSUANT TO SECTION 161.053 OR 161.052, FLORIDA STATUTES FINDINGS OF FACT AND CONCLUSION OF LAW: The request for a field permit was considered by the staff designee of the Department of Environmental Protection and found to be in compliance with the requirements of Chapter 62B-33, Florida Administrative Code(F.A.C.). Approval is specifically limited to the activity in the stated location and by the project description, approved plans (ifany), attached standard conditions, and any special conditions stated below pursuant to Paragraph I61.053(5), Florida Statutes (F.S.). This permit may be suspended or revoked in accordance with Section 62 4. 100, F.A.C. PROJECT LOCATION: N0070/N0570 of DEP R-21 3880 N. AIA (Hibiscus by the Sea Condominium Association, Inc) Fort Pierce PROJECT DESCRIPTION: As per attached plan, may extend dune walkover seaward and ramp down to grade. Seaward extension and re -configuration is not to exceed multi -residential dune walkover guideline maximums (6'wide, 6" posts, no further than 10' seaward of vegetation, no concrete). Page 1 of 4 DEP form 73-122 (Updated 5105) .. matNo.-8033373 _ SL SPECIAL PERMIT CONDITIONS: The permit is valid only after all applicable federal, state, and local permits are obtained and does not authorize contravention of local setback requirements or zoning or building codes. This permit and public notice shall be posted on the site immediately upon issuance and shall remain posted along with local approval until the completion of any activity authorized by this permit Other special conditions of this permit include: Standard field permit conditions and dune walkover guidelines prevail, no lighting is authorized. No additions or modifications w/o prior DEP approval. No work authorized during marine turtle nesting season (3/1 through 10/31). For additional seaward encroachment, the existing 9'x V steps are to be removed and allowed to re -vegetate with native dune vegetation. STANDARD PERMIT CONDITIONS: The permittee shall comply with the attached standard field permit conditions. APPLICANT INFORMATION: I hereby certify that I am either. (Is) the owner of the subject property or (lb) I have the owner's consent to secure this permit on the owner's behalf, and that (2) I shall obtain any applicable licenses or permits which may be required by federal, state, county, or municipal law prior to commencement of the authorized work; (3 I//a�ck�nowledgthat�thh//Ie� authorized work is what I request d (4) I accept responsibility for'c/omp%Hance with all permit conditions. Applicant's Signature /�[.X. n m t�^tiVN� Date �prlrZ Telephune No.(�Yi Applicant's Printed Name P-14LRJ Lu / Address �D /d r� y rT%l.4 T( y/i/Vr$D,c/ /S nd ...- - If applicant is an agent: See above �) Prinledname ofproperty owner Property owner's address Property owner's telephone no. DEPARTMENT FINAL ACTION AND FILING AND ACKNOWLEDGMENT: This field permit is approved on behalf ofthe Department of Environmental Protection by the undersigned staff designee, and filed on this date, pursuant to section 120.52, F.S., with the undersigned designated Deputy Clerk, receipt of which is hereby acknowledged. 9., W -�. / Jason M. Spanier / 08/30/2018 Clerk EXPIRATION DATE: 02/28/2019 (Emergency permits issued pursuant to Section 62B-33.014, F.A.C., are valid for no more than ninety days and other field permits are valid for no more than 12 months. The staff designee may specify a shorter time limit) EMERGENCY PERMIT: 11 YES ❑✓ NO Approved plans are attached: ❑✓ YES ❑ NO Page 2 of 4 DEP form 73-122 (Updated 5/05) -ennitNo, -8033373 SL POST PERMIT AND PUBLIC NOTICE CONSPICUOUSLY ON THE SITE PUBLIC NOTICE The foregoing constitutes final agency action. Any person whose substantial interests are affected by any decision made by the Department on the Field Permit has a right to request an administrative hearing in accordance with the provisions of Sections 120.569 and 120.57, F.S. The request for an administrative hearing must comply with the provisions of Rule 28-106.201, F.A.C., and must be received by the Department (at the address given below) within twenty-one (21) days from the date of this notice. When the Department receives an adequate and timely filed request for hearing, the Department will request the assignment of an administrative law judge. Once the administrative law judge is requested, the Division of Administrative Hearings will have jurisdiction over the formal proceeding and the Department (as the referring agency) will take no further action with respect to the proceeding except as a party litigant. Section 120.54(5)(b)4, F.S., and Rule 28-106.201(2), F.A.C., explain that the following items must be included in a petition for a formal administrative hearing (a) The name and address of each agency affected and each agency's file or identification number, if known; (b) The name, address, any e-mail address, any facsimile number, and telephone number of the petitioner, if the petitioner is not represented by an attorney or a qualified representative; the name, address, and telephone number of the petitioner's representative, if any, which shall be the address for service purposes during the course of the proceedings; and an explanation of how the petitioner's substantial interests will be affected by the agency determination; (c) A statement of when and how the petitioner received notice of the agency decision; (d) A statement of all issues of material fact disputed by the petitioner, or a statement that there are no disputed facts; (e) A concise statement of the ultimate facts alleged, including a statement of the specific facts that the petitioner contends warrant reversal or modification of the Department's action; (f) A statement of the specific rules or statutes the petitioner contends require reversal or modification of the Dep"ent's action, including an explanation of how the alleged facts relate to the specific rules or statutes; and (g) A statement of the relief sought by the petitioner, stating precisely the action that the petitioner wants the Department to take with respect to its action. A person may request an extension oftime to petition for an administrative hearing. The person filing the request for extension must do so within the time limits for filing a petition described above. The request must state why an extension of time is needed. The Department will grant an extension only when good cause is shown. If a petition or a request for time extension is filed, further order of the Department becomes necessary to effectuate this Field Permit. Accordingly, the Department's final action may be different from the position taken in this notice. Actions undertaken by any person under this permit, pending the lapse of time allowed for the filing of such a request for hearing, may be subject to modification, removal, or restoration. Failure to petition within the allowed time frame constitutes waiver of any right that a person has to request a hearing under Section 120.57, F.S., and to participate as a party to the proceeding. If a legally sufficient petition for hearing is not timely received, this notice constitutes final agency action. When this order becomes final and is filed with the Department Clerk, any party to the order has the right to seek judicial review under Section 120.57, F.S., and Rule 9.030(b)l(c) and 9.110, Florida Rules of Appellate Procedure. A notice of appeal must be filed within thirty (30) days with both the Department Clerk (see address below) and with the appropriate district court of appeal. The notice filed with the district court must be accompanied by the filing fee specified in Section 35.33(3), F.S. Any subsequent intervention will be only by the approval of the presiding officer on motion filed under Rules 28-5.207 or 60Q-2.010, F.A.C. All requests for hearings are to be filed with the Department at the following address: Florida Department of Environmental Protection Office of General Counsel Department Clerk 3900 Commonwealth Boulevard Mail Station 35 Tallahassee, Florida 32399-3000 Page 3 of 4 DEP form 73-122 (Updated 5105) Permit No.-8033373 SL STANDARD FIELD PERMIT CONDITIONS The following conditions shall apply to FIELD PERMITS (unless waived by DEP or modified by special permit condition). In the event of a conflict between a field permit condition and a special permit condition, the special condition shall prevail. 1) The permittee shall carry out the construction or activity for which the permit was granted in accordance with the plans and specifications that were approved by DEP as part of the permit. Any deviation there from shall be grounds for suspension of the work and revocation of the permit pursuant to Section 120.60(7), F.S., and may result in assessment of civil fines or issuance of an order to alter or remove the unauthorized structure, or both. No other construction or activities shall be conducted. No modifications to project size, location, or structural design are authorized. A copy of the permit shall be conspicuously displayed at the project site. 2) The permittee shall conduct the construction or activity authorized under the permit using extreme care to prevent any adverse impacts to the beach and dune system, marine turtles and their nests and habitats, or adjacent property and structures. 3) The permittee shall allow any duly authorized member of the staff to enter upon the premises associated with the project authorized by the permit for the purpose of ascertaining compliance with the terms of the permit and with the rules of DEP, until all construction or activities authorized or required in the permit have been completed and the project accepted by DEP. 4) The permittee shall hold and save the State of Florida, DEP, its officers and employees, harmless from any damage (no matter how occasioned and no matter what the amount) to persons or property that might result from the construction or activity authorized under the permit and from any and all claims and judgments resulting from such damage. 5) The permittee shall allow DEP to use all submitted records, notes, monitoring data, and other information relating to construction or any activity under the permit for any purpose it may deem necessary or convenient, except where such use is otherwise specifically forbidden by law. 6) Construction traffic shall not operate and building materials shall not be stored on vegetated areas seaward of the control line, unless specifically authorized by the permit. If (in the opinion of DEP staff) this requirement is not being met, positive control measures shall be provided by the permittee at the direction of DEP staff. Such measures may include temporary fencing, designated access roads, adjustment of construction sequence, or other requirements. 7) The permittee shall not disturb existing beach and dune topography and vegetation except as expressly authorized in the permit. Before the project is considered complete, any disturbed topography or vegetation shall be restored (as prescribed in the permit) with suitable fill material or revegetated with appropriate beach and dune vegetation. 8) The fill material shall be obtained from a source landward of the control line and shall consist of sand which is similar to that already on the site in both grain size and coloration. This fill material shall be free of construction debris, rocks, or other foreign matter. A sample of the sand shall be provided to the staff representative of the Bureau of Beaches and Coastal Systems during the preconstruction conference. 9) If surplus sand fill results from any approved excavation seaward of the CCCL, such material shall be distributed seaward of the CCCL on the site, as directed by DEP staff (unless otherwise specifically authorized by the permit). 10) Any native salt -resistant vegetation destroyed during construction shall be replaced with plants of the same species or, by authorization of DEP, with other native salt -resistant vegetation suitable for beach and dune stabilization. Unless otherwise specifically authorized by the staff, all plants installed in beach and coastal areas (whether to replace vegetation displaced, damaged, or destroyed during construction or otherwise) shall be of species indigenous to Florida beaches and dunes (i.e., sea oats, sea grape, saw palmetto, panic grass, salt meadow hay cord grass, seashore salt grass, and railroad vine). 11) All topographic restoration and revegetation work is subject to approval and acceptance by DEP staff. 12) If not specifically authorized elsewhere in this permit, no operation, transportation, or storage of equipment or materials is authorized seaward of the dune crest or rigid coastal structure during the marine turtle -nesting season. The marine turtle -nesting season is May 1 through October 31 in all counties (except Brevard, Indian River, St. Lucie, Martin, Palm Beach and Broward counties where marine turtle nesting occurs during the period of March 1 through October 31). 13) If not specifically authorized elsewhere in this permit, no temporary lighting of the construction area is authorized at any time during the marine turtle -nesting season and no additional permanent exterior lighting is authorized. 14) This permit has been issued to a specified property owner and is not valid for any other person. Page 4 of 4 DEP form 73-122 (Updated 5105) V , f 1 4 ■ N 5' EXISTING 9'X4' ii STAIRS TO BEACH 50' RAMP ADDITION TO BE REMOVED SLOPE 8:1 SHOWER `— AREA 92. TO CONDOMINIUM 2/1 •"NOTES'- -PROPOSED WORK IS TO CONSTRUCTA 5'X50' RAMP ADDITION TO EXISTING BOARDWALK, REMOVE EXISTING STEPS, AND REPLACE RAIL CAP ON EXISTING PLATFORM WITH P.T.2" X 12" -ALL NEW HARDWARE TO BE SS AND ALL LUMBER TO BEP.T. -ALL NEW POSTS TO BE 6" X 6' P.T. POSTS (0.80 CCA TREATED MIN.) - MIN. PENETRATION INTO SAND VARIES 4' TO T OR AS NECESSARY TO PROVIDE ADEQUATE BEARING STABILITY 01. 20' ' 0' - DECK DESIGN LOADS TO MEET 2014 FBC: WIND LOAD AS PER ANSVASCE 7-10 SPEED -170 MPH EXPOSURE =D GRAPHIC SCALE IMPORTANCE FACTOR = 1.0 Environmental BOARDWALK RAMP ADDITION Paul Welch, Inc. 1?s PLAN VIEW 1984 SW Biltmore Street, 9114 by the Sea ]Inc Port St: Lucie, FL 34984 -Hibiscus ervices, l Condominium Association, Inc. 79D1 SWYellowtail Avenue 3880 N'A1A Port Saint Lucie, FL 34963 Fort Pierce, Florida Paul Welch, PE No. 29945 Phone: 772-215J997 Fax: 772A78d520 PIN# 1423-805-0000-0003 sume 1„ = 40 JAN 2017 SHEET 1 of 4 www.disenvironmeiitalservices.com L 110.5, 88. TO CCONNDDOOMMINX+NIUM '•'NOTES— P.T. -ALL NEW POSTS TO BE6•X 6' P.T. POSTS (0.80 CCATRE 4' TO 6' OR AS NECESSARY TO PROVIDE ADEQUATE B - DECK DESIGN LOADS TO MEET 2014 FBC: WIND LOAD AS PER ANS9ASCE 7-10 SPEED =170 MPH EXPOSURE= D IMPORTANCE FACTOR =1.0 X 12- 4�N & LANDING X S LANDING S _ EXISTING 9'X4' STAIRSTO BEACH TO BE REMOVED — EXISTING SHOWERAREATO REMAIN pP�11- C .. psi O%% e 'motC ElyS :Qtio. No 29945 _ o' STATE pp iir .�� AN CRF9!:- ess'Si2NA e E��� `owe BOARDWALK REMOVE EXISTINGSTEPS, PENETRATION INTO SAND VARIES a 20. 40' GRAPHIC SCALE BOARDWALK RAMP ADDITION Paul -Welch;.Inc. nvironmental PLAN VIEW 1984 SW Biltmore Street, 14 Inc.Hibiscus by the Sea Part St Lucie, FL 34984 / S ervices, ICondominium Association, Inc. A or19otSintLuce,FILvenue 3880N.A1A JAN `2 PJ 20i0 I Port Saint Luele,.FL 34953 Fort Pierce, Florida ?-Rnd_hnnn-nnn_z PauFWelCh, PE N0.29945 PIN#142 Phane:772-215 4997 Fax: 772-8794520 - w .dlsenvironmentalservices.com SwE JAN 2018I SHEET 1 of 4 I on 1-12' O GRASPABLE HAND. RAIL OFFSET FROM Y X V WITH BRACKETS 7 X S'VERTICAL RAIL (TOP RAIL) P.T. RAIL e' P.T. RAIL CAP • i I E70SNNG GRADE 2' X V PICKETS _ 4' O.C. (TYP) 7 X 12' P.T. CROSSTIES S' X 6' P.T. POSTS (ABOVE DEC19 SPACING VARIES 4'-10. O.C. (TYP.) 2' X S'P.T. STRINGERS Is- O.C. (MAX) 2' X e' P.T. BOTTOM RAIL ATTACHED WITH (2) 914 SS SCREWS PER PILE AT DECK LEVEL FOR EDGE PROTECTION (2) 518' SS THRU:BOLTS (FYP) PER POST 2' X 6' P.T. DECKING -NEW POSTSTOBE 6' X 6' P.T. POSTS (0.80CCA TREATEI -& MIN. PENETRATION FOR ALL POSTS GREATER THAN 7' - 4' MIN. PENETRATION FOR ALL POSTS WrrH 7' OR LESS - 2' X 7 PICKETS NOT ALL SHOWN FOR CLARITY -ALL HARDWARETO BE SS AND ALL LUMBER TO BE P.T. Z§ECCIy-@F�A$GNED. RASPABLE HAND RAIL LOCATE�36°TO 36' OVE OEC L:nvironmenta S ervices, Inc. 1901SWYellowtail Avenue Port Saint Lucie, FL 34953 Phone: 772-215-3997 Fax: 772-879AS20 vrNw.dlsenvironmentalservices.com .7X 8'P.T. TOP RAIL I I WITH (2) S14 SS SCREWS PER POST Hibiscus by the Sea -- Condominium Association, Inc. 3880 N A1A Fort Pierce, Florida. PIN# 1423-805-0000-0003 1"=10' `�o�aOQPUL C.1®�y°F� es�s 00,. • �� c eNs. qS'-.e. a �t • No 29,9 =,33 T - 7ATE OF ��m '�QRIDP` osBS'ONA....... Ea 0' 5' 10, GRAPHIG SCALE Paul Welch, Inc: 1984 SW Biltmore Street, 114 Port -St. Lucie, FL 34984 JAN 2 5 2018 Paul Welch, PE No. 29945 JAN2017 SHEET2of4 REVISED JAN 2018 M/ 6' X I 2' X 6' P.T 2'X Ir P. (2) 51W SS l (TYF 2` X 12' P.T. —NOTES- - ALL NEW POSTS TO BE e' X 6' 6' CCA TREATED MIN.) - MIN. PENETRATION INTO SAND TO BE PT_ 2' X S' P.T. DECKING NOTALL SHOWN FOR CLARITY - DECKING WILL BE ATTACHED WITH %18 SS DECKSCREIN qE'-nvironmental Services, Inc. 101 SW Yellowtail Avenue Port Saint Lucie, FL 34953 Phone: 772-2154997 Fax: 772-879-4520 vmnv.dlsenvlrorimentalservices.com RAMP PLAN VIEW DETAIL — Hibiscus by the Sea Condominium Association, Inc. 3880 N A1A Fort Pierce, Florida scats 1" = 3' VARIES -1w O.C. (TYR) No 29945 mom' � �LUm STATE OF •1j p• On `'aseSBgONA� E�ea'` 0. 1.& 3' GRAPHIC SCALE Paul Welch,.lnc.- 1994SW Biltmore Street, 14- Port St Lucie, FL 34984 JAN251018 J� Paul Welch, PE No. 29945 JAN 2017 SHELT3of4 SED JAN 2018 w 2' X 8' P.T. RAIL CAP 2' X e' P.T. AND 2' X 6' P.T. BOT WITH r X 2' 4' BOTTOM RAILATDE (2) 2' X 6' P-T. DECKING —� a, x 6' P.T. POSTS _ (ABOVE DECK) 2' X 6' P.T. STRINGERS 24' O.C. (MAX) — T X 12' P.T. CROSS -TIES - NEW POSTS TO. BE 6' X 6' P:T. - W MIN- PFNFTHATIM FnP a,, Environmental Services, Inc. 1901 SW Yellowtall Avenue Port Saint Lucle,FL 34953 Phone: 772-215-3997 Fax: 772-97"20 www.dlsenvironmentalsomices.com • EXISTING GRADE VARIES / tBnote X)N- 7C- PVohs' ....... C E NSF m y No 29945 a Q A e P ems: sk :Yr a p":• . STATE OF �B0A®SB;0NALt EN%% 1) OSED HEIGHT ISED HEIGHT 0' 1' 2' IITHEY GRAPHIC SCALE RAMP CROSS SECTION Paul Welch, Inc. 11 VIEW DETAIL 1984 SW ®iltmore-Street, 0114 - Hibiscus .by the.Sea Poit St.:Lucie, FL 34984 - -- Condominium Association, Inc. - --/ P eo N J AN 2 5 2i115 For3880 -d ... i PIN# 1423-805-0006-00" Paul Welch, PE No. 29945: JAN 2017 SHEEP 4 of 4 REVISED JAN 2018 j j FLORIDA DEPARTMENT OF ENVIRONMENTAL PROTECTION Division of Water Resource Management Coastal Constrnction Control Line Program' 2600.BIainS[one Road, M.S. 3522 -$U33279 _ SL. Tallahassee, FL 32399-2400 .. Permit No. Phone: (850) 245-8336 - " No. of Pages"Attached:.8 FIELD PERMIT PURSUANT TO SECTION-161.053 OR 161.052,.FLORIDA STATUTES FINDINGS OF FACT AND CONCLUSION OF LAW: The request for a field permit was considered by the staff designee of the Department of Environmental Protection and found to be in compliance with the requirements of Chapter 62B-33, Florida Administrative Code (F.A.C.). Approval is specifically limited to the activity in the stated location and by the project description, approved plans (if any), attached standard conditions, and any, special conditions stated below pursuant to Paragraph 161.053(5), Florida Statutes (F.S.). This permit maybe suspended or revoked in accordance with Section 62-4.100, F.A.C. PROJECT LOCATION:, N0070/N0570 of DEP R-21 3880 N. A I A (Hibiscus by the Sea Condominium Association, Inc). Fort Pierce Ri111J T-AC HQ iT'O!T — ID..S NOV 2 2 2011 �.. C"SIDE BY. :........:....... RE'R . ZRG l TEC OJECT DESCRIPTION: As per attached plan, may extend dune walkover seaward aniframp down to grade. Seaward extensionand re -configuration is not to exceed.multi-residential dune walkover guideline maximums (6'wide; 6" _posts; no further than 10' seaward of vegetation, no concrete). .. .... _ .... - .. E - Cy" PY .. - Page I of 4 " DEP form 73-122 (Updated 5105) • CNI. -8033279 - SL SPECIAL PERMIT CONDITIONS: The permit is valid only after all applicable federal, state, and local permits are obtained and does not authorize contravention of local setback requirements or zoning or building codes. This permit and public notice shall be posted on the site immediately upon issuance and shall remain posted along with local approval until the completion of any activity authorized by this permit. Other special conditions of this permit include: Standard field permit conditions and dune walkover guidelines prevail, no lighting is authorized. No additions or modifications w/o prior DEP approval. No work authorized during marine turtle nesting season (3/1 through 10/31). For additional seaward encroachment, the existing 9'x4' steps are to be removed and allowed to re -vegetate with native dune vegetation. STANDARD PERMIT CONDITIONS: The permittee shall comply with the attached standard field permit conditions. APPLICANT INFORMATION: I hereby certify that I am either: (la) the owner of the subject property or (Ib) I have the owner's consent to secure this permit on the owner's behalf; and that (2) I shall obtain any applicable licenses or permits which may be required by federal, state, county, or municipal law prior to commencement of the authorized work; (3 acknowledge t authorized work is what I requ/e'°ted; a d (4))I7accept responsibility for compliance with all permit conditions. Applicant's Signature L Date ��/n, / Telephone /Noo Applicant's Printed Name �V // /LEI ddress/Q N �/'r,UY/ /d(//f/U/�/7L ✓z / Y'g If applicant is an agent: See above �) Printed name ofproperry owner Property owner's address Property owner's telephone no. DEPARTMENT FINAL ACTION AND FILING AND ACKNOWLEDGMENT: This field permit is approved on behalf of the Department of Environmental Protection by the undersigned staff designee, and filed on this date, pursuant to section 120.52, F.S., with the undersigned designated Deputy Clerk, receipt of which is hereby acknowledged. �aee.�7rG �oar�u. /Jason M. Spanier /11/12/17 Staff Design-" Depury Clerk Printed Name ofDesignee/Depury Clerk Dale EXPIRATION DATE: 02/28/18 (Emergency permits issued pursuant to Section 62B-33.014, F.A.C., are valid for no more than ninety days and other field permits are valid for no more than 12 months. The staff designee may specify a shorter time limit.) EMERGENCY PERMIT: ❑ YES ENO Approved plans are attached: EYES ❑ NO Page 2 of 4 DEP form 73-122 (Updated 5105) • hermit No.-8033279 _ SL POST PERMIT AND PUBLIC NOTICE CONSPICUOUSLY ON THE SITE PUBLIC NOTICE The foregoing constitutes final agency action. Any person whose substantial interests are affected by any decision made by the Department on the Field Permit has a right to request an administrative hearing in accordance with the provisions of Sections 120.569 and 120.57, F.S. The request for an administrative hearing must comply with the provisions of Rule 28-106.201, F.A.C., and must be received by the Department (at the address given below) within twenty-one (21) days from the date of this notice. When the Department receives an adequate and timely filed request for hearing, the Department will request the assignment of an administrative law judge. Once the administrative law judge is requested, the Division of Administrative Hearings will have jurisdiction over the formal proceeding and the Department (as the referring agency) will take no further action with respect to the proceeding except as a party litigant. Section 120.54(5)(b)4, F.S., and Rule 28-106.201(2), F.A.C., explain that the following items must be included in a petition for a formal administrative hearing (a) The name and address of each agency affected and each agency's file or identification number, if known; (b) The name, address, any e-mail address, any facsimile number, and telephone number of the petitioner, if the petitioner is not represented by an attorney or a qualified representative; the name, address, and telephone number of the petitioner's representative, if any, which shall be the address for service purposes during the course of the proceedings; and an explanation of how the petitioner's substantial interests will be affected by the agency determination; (c) A statement of when and how the petitioner received notice of the agency decision; (d) A statement of all issues of material fact disputed by the petitioner, or a statement that there are no disputed facts; (e) A concise statement of the ultimate facts alleged, including a statement of the specific facts that the petitioner contends warrant reversal or modification of the Department's action; (f) A statement of the specific rules or statutes the petitioner contends require reversal or modification of the Department's action, including an explanation of how the alleged facts relate to the specific rules or statutes; and (g) A statement of the relief sought by the petitioner, stating precisely the action that the petitioner wants the Department to take with respect to its action. A person may request an extension of time to petition for an administrative hearing. The person filing the request for extension must do so within the time limits for filing a petition described above. The request must state why an extension of time is needed. The Department will grant an extension only when good cause is shown. If a petition or a request for time extension is filed, further order of the Department becomes necessary to effectuate this Field Permit. Accordingly, the Department's final action may be different from the position taken in this notice. Actions undertaken by any person under this permit, pending the lapse of time allowed for the filing of such a request for hearing, may be subject to modification, removal, or restoration. Failure to petition within the allowed time frame constitutes waiver of any right that a person has to request a hearing under Section 120.57, F.S., and to participate as a party to the proceeding. If a legally sufficient petition for hearing is not timely received, this notice constitutes final agency action. When this order becomes final and is filed with the Department Clerk, any party to the order has the right to seek judicial review under Section 120.57, F.S., and Rule 9.030(b)l(c) and 9.110, Florida Rules of Appellate Procedure. A notice of appeal must be filed within thirty (30) days with both the Department Clerk (see address below) and with the appropriate district court of appeal. The notice filed with the district court must be accompanied by the filing fee specified in Section 35.33(3), F.S. Any subsequent intervention will be only by the approval of the presiding officer on motion filed under Rules 28-5.207 or 60Q-2.010, F.A.C. All requests for hearings are to be filed with the Department at the following address: -- Florida Department of Environmental Protection Office of General Counsel Department Clerk 3900 Commonwealth Boulevard Mail Station 35 Tallahassee, Florida 32399-3000 Page 3 of 4 DEP form 73-122 (Updated 5/05) • IPermit No.-8033279 - SL STANDARD FIELD PERMIT CONDITIONS The following conditions shall apply to FIELD PERNUTS (unless waived by DEP or modified by special permit condition). In the event of a conflict between a field permit condition and a special permit condition, the special condition shall prevail. 1) The permittee shall carry out the construction or activity for which the permit was granted in accordance with the plans and specifications that were approved by DEP as part of the permit. Any deviation there from shall be grounds for suspension of the work and revocation of the permit pursuant to Section 120.60(7), F.S., and may result in assessment of civil fines or issuance of an order to alter or remove the unauthorized structure, or both. No other construction or activities shall be conducted. No modifications to project size, location, or structural design are authorized. A copy of the permit shall be conspicuously displayed at the project site. 2) The permittee shall conduct the construction or activity authorized under the permit using extreme care to prevent any adverse impacts to the beach and dune system, marine turtles and their nests and habitats, or adjacent property and structures. 3) The permittee shall allow any duly authorized member of the staff to enter upon the premises associated with the project authorized by the permit for the purpose of ascertaining compliance with the terms of the permit and with the rules of DEP, until all construction or activities authorized or required in the permit have been completed and the project accepted by DEP. 4) The permittee shall hold and save the State of Florida, DEP, its officers and employees, harmless from any damage (no matter how occasioned and no matter what the amount) to persons or property that might result from the construction or activity authorized under the permit and from any and all claims and judgments resulting from such damage. 5) The pemtince shall allow DEP to use all submitted records, notes, monitoring data, and other information relating to construction or any activity under the permit for any purpose it may deem necessary or convenient, except where such use is otherwise specifically forbidden by law. 6) Construction traffic shall not operate and building materials shall not be stored on vegetated areas seaward of the control line, unless specifically authorized by the permit. If (in the opinion of DEP staff) this requirement is not being met, positive control measures shall be provided by the permittee at the direction of DEP staff. Such measures may include temporary fencing, designated access roads, adjustment of construction sequence, or other requirements. 7) The permittee shall not disturb existing beach and dune topography and vegetation except as expressly authorized in the permit. Before the project is considered complete, any disturbed topography or vegetation shall be restored (as prescribed in the pemtit) with suitable fill material or revegetated with appropriate beach and dune vegetation. 8) The fill material shall be obtained from a source landward of the control line and shall consist of sand which is similar to that already on the site in both grain size and coloration. This fill material shall be free of construction debris, rocks, or other foreign matter. A sample of the sand shall be provided to the staff representative of the Bureau of Beaches and Coastal Systems during the preconstruction conference. 9) If surplus sand fill results from any approved excavation seaward of the CCCL, such material shall be distributed seaward of the CCCL on the site, as directed by DEP staff (unless otherwise specifically authorized by the permit). 10) Any native salt -resistant vegetation destroyed during construction shall be replaced with plants of the same species or, by authorization of DEP, with other native salt -resistant vegetation suitable for beach and dune stabilization. Unless otherwise specifically authorized by the staff, all plants installed in beach and coastal areas (whether to replace vegetation displaced, damaged, or destroyed during construction or otherwise) shall be of species indigenous to Florida beaches and dunes (i.e., sea oats, sea grape, saw palmetto, panic grass, salt meadow hay cord grass, seashore salt grass, and railroad vine). 11) All topographic restoration and revegetation work is subject to approval and acceptance by DEP staff. 12) If not specifically authorized elsewhere in this permit, no operation, transportation, or storage of equipment or materials is authorized seaward of the dune crest or rigid coastal structure during the marine turtle -nesting season. The marine turtle -nesting season is May 1 through October 31 in all counties (except Brevard, Indian River, St. Lucie, Martin, Palm Beach and Broward counties where marine turtle nesting occurs during the period of March 1 through October 31). 13) If not specifically authorized elsewhere in this permit, no temporary lighting of the construction area is authorized at any time during the marine turtle -nesting season and no additionalpermanentexterior lighting is authorized. 14) This permit has been issued to a specified property owner and is not valid for any other person. Page 4 of 4 DEP form 73-122 (Updated 5/05) n l 5- EXISTING 9'X 4' 40'RAMP ADDITION .STAIRS TO BEACH - - SLOPE 8.1 �, TO BE REMOVED .; .. SHOWER AREA',' 10.5' ' 110.5' ' 5' 10.5'I 92,. 5- TO CONDOMINIUM 2/1 ... NOTES... - PROPOSED WORK IS TO CONSTRUCT A V X 40' RAMP ADDITION TO EXISTING BOARDWALK, REMOVE EXISTING STEPS, AND REPLACE RAIL CAP ON EXISTING PLATFORM WITH P.T. 2' X 12- - ALL HARDWARE TO BE SS OR HDG AND ALL LUMBER TO BE P.T. -ALL NEW PILES.TO BE 6"O MARINE PILES- MIN. PENETRATION INTO BAND VARIES 4'.TO V OR AS NECESSARY TO.PROVIDE ADEQUATE BEARING STABILITY - DECK DESIGN LOADS TO MEET 2014 FBC: - - - - WIND LOAD ASRERANSI/ASCE 7-10 SPEED=170 MPH EXPOSURE = D IMPORTANCE FACTOR =1.0 - - - - - - BOARDWALK RAMP ADDITION I'sEnv1rOTYTTI'e11ia1 PLAN VIEW S[`^t Hibiscus by the Sea . ervices, Inc., Condominium Association, Inc. 19011 SW Yellovitail Avenue- - — 3880 N AIIA Port Saint Lucie, FL 34953 Fort Pierce; Florida Phone: 771-215-3997 Fax: 772.879-4520 PIN# 1423.805.0000-0003 www:dlsenvironmentalsomices.com scnLe: � . N JAN 2017 01. 20' 40' IN 11111110111111 GRAPHIC SCALE SHEET 1 of4 EXISTING 40' RAMP ADDITION 10.6' PLATFORM - , 8' O.C. 8:1. SLOPE 2' X 12- P.T. RAIL CAP 2' X 8' P.T. RAIL CAP 2' X 8' P.T. TOP RAIL 2'X 6'.P.T. MIDRAIL / 2'X8" P.T.CROSS-TIES) 6° 0 MARINE PILES (ABOVE DECK) 2' X 8" P.T. STRINGERS _ 24' D.C. (MAXJ (2) 1/2' CARRIAGE BOLTS (TYP)PER PILE - 2'X6'P.T. DECKING "'NOTES"' - NEW PILES TO BE6.0 MARINE PILES 0' 5' 101 , -6' MIN. PENETRATION FOR ALL PILES GREATER THAN 7'EXPOSED HEIGHT -4' MIN. PENETRATION FOR ALL PILES WITH TOR LESS EXPOSED HEIGHT -ALL HARDWARE TO BE SS OR HOG AND ALL LUMBER TO BE P.T. GRAPHIC SCALE - DECKING WILL BE ATTACHED WITH #10 SS DECK SCREW X3' _ - - OVERALL -RAMP . lron 1ehtz CROSS SECTION VIEW EriV Hibiscus by the Sea Services;. I11C.:' Condominium Association, Inc. 1901',SW Yellowtall Avenue - - 3880 N A1A Port Saint Lucie, FL 34953 Fort Pierce, Florida-- Phone: 772-215J997 Fax: 772.879-4520 : PIN# 1423-805-0000=(1004 www.disenvironmentalsemices.com Sc E'' - - - V, =10' JAN 2017 SHEET 2 of 4 I 5 I (A 2" X 6"P.T. 2" X 8" P.T 2, (2)'1/2-CARRI (TYI 2" X 8" P.T. I 8' O.C. (TYP.) ""NOTES*- _ - ALL NEW PILES TO BE6"ID MARINE PILES- MIN. PENETRATION INTO SAND VARIES - p 1.5'. 3' 4' TO6' OR AS NECESSARY TO PROVIDE ADEQUATE BEARING STABILITY - ALL HARDWARE TO BE SS OR HOG AND ALL LUMBER TO BE P.T. -2"X6" DECKING NOT ALL SHOWN FOR CLARITY GRAPHIC SCALE -DECKING WILL BE ATTACHED WITH #10SSOECKSCREW 3° Environment' al. PLAN VIEW DETAIL .: C� ' Hibiscus by the Sea ►.7Services; IilC.,- Condominium Association, Inc.' -.-1901SWYellowtallAvenue -- .. - 3880NA1A Port Saint Lucie, FL 34953 Fort Pierce, Florida Phone:.772-215.3997 'Fax: 772-879-4520 - PIN# 1423-805-0000-000-3 scN.e: 1" = 3' JAN 2017 SHEET 3 of 4 www.dlsenvironmentalservices.com 2".X W P.T. RAIL 2- X 6' P.T. TOF 2'X 6'P.T. MIL (2) 1/2- CARRIAGE BOLTS (TYP) PER PILE 2' X 6" P.T. DECKIP 6'0 PI (ABOVE DE 2' X 8° P.T. STRIP 24" O.C. ... NOTES... _ - NEW PILES TO. BE 6"0 MARINE PILES 0' - 1' 2' - 6' MIN. PENETRATION FOR ALL PILES GREATER THAN T EXPOSED HEIGHT .-4' MIN. PENETRATION FORALLPILES WITH TOR LESS EXPOSED HEIGHT .. - ALL HARDWARE TO BEGS OR HDG AND ALL LUMBER TO -BE P.T. GRAPHIC SCALE. - DECKING WILL BE ATTACHED WITH #10 SS DECK SCREWX3- - Fnviror1111ental'" RAMP CROSS SECTION VIEW DETAIL Hibiscus by the Sea Inc. -Services, Inc. Condominium Association, Inc. - - 190tsW YellowtalbAvenue- - - -_ - - 3880 N.A1A Port Saint Lucie, FL 34953 - Fort Pierce; Florida- - Phone: 772-2153997 .Fax: 772.879-4520 - PIN# 1423-805-00004003 . sme 1"=2' JAN:2017 SHEET401`4. www.dlsenvironmentalsemices.com ` T ( 5. 9'X4',AREA TO BE 40'RAMP ADDITION I{ .REPLANTED -- SLOPE 8:1 I - -L SHOWER L AREA 10.5' 110.5' S 10.5.1 92 5' TO CONDOMINIUM .. _ .. .. 01 20 40' _ ..' .. .,..NOTES.,. .. .. :. -AREA OF EXISTING STEPS TO BE REPLANTED WITH SEA OATS (Uniolapaniculata)-(10)1-GALLON'PLANTS GRAPHIC SCALE - BOARDWALK RAMP ADDITION Env lrOnmentall- PLANTING PLAN Hibiscus by the Sea S erviceS; Condominium Association, Inc. . _19o1 SW Yellowtall Avenue-- — :-"-- 3880 N A1A Port Saint Lucie; FL 34953 Fort Pierce; Florida - Phone: 772-215-3997 Fax: 772-8794520. " PIN# 1423-805-0000-0003 scue wwwAlsenvironmentalsomices.com 1" = 40'.. JAN:2017 EXHIBIT I I 40' RAMP ADDITION SLOPE 8:1 10.5' C I70.5' 92' TOCONDOMINIUM 2 1 EXISTING 9' X 4' STAIRS TO BEACH TO BE REMOVED SHOWER AREA 5' 10.5'I ••'NOTES•" - PROPOSED WORK IS TO CONSTRUCTA 5' X 40' RAMP ADDITION TO EXISTING BOARDWALK, REMOVE EXISTING STEPS, AND REPLACE RAIL CAP ON EXISTING PLATFORM WITH P.T. 2' X 12' -ALL NEW HARDWARE TO BE SS AND ALL LUMBER TO BE P.T. -ALL NEW POSTS TO BE 8" X 0" P.T. POSTS (0.80 CCA TREATED MIN.) - MIN. PENETRATION INTO SAND VARIES 4' TO V OR AS NECESSARY TO PROVIDE ADEQUATE BEARING STABILITY - DECK DESIGN LOADS TO MEET 2014 FBC: WIND LOAD AS PER ANSVASCE 7-10 SPEED =170 MPH EXPOSURE =D IMPORTANCE FACTOR=1.0 1?s Environmental Services, Inc. 1901 SW Yellowtail Avenue Port Saint Lucie, FL 34953 Phone: 772-2153997 Fax: 772-879-4520 www.disonvironmentalservlces.com RAMP ADDITION Hibiscus by the Sea Condominium Association, Inc. 3880 N A1A Fort Pierce, Florida PIN# 1423-805-0000-000-3 N 0' 20' 40' m GRAPHIC,SCALE Paul Welch, Inc. 1984 SW Biltmore Street, 114 Port St LyeI F,J 3A984 Paul Welch, PELN�oIl.I129945 a� JAN 2017 1 SHEET 1 of 4 EXISTING 40' RAMP ADDITION 10.5' PLATFORM B' OTC 8:1 SLOPE I - (TWTI - I :-; - GRADE 2' X 12' P.T. RAIL CAP 2' X 8' P.T. RAIL CAP 2' X B' P.T. TOP RAIL 2' X 6' P.T. MID RAIL 2' X 12' P.T. CROSS -TIES 6' X 6' P.T. POSTS (ABOVE DECK) 2' X 8' P.T. STRINGERS 24' O.C. (MAX.) (2) 61W SS THRU BOLTS (TYP) PER POST '••NOTES••• 2'X6'P.T. DECKING- - NEW POSTS TO BE 6' X 6' P.T. POSTS (0.80 CCA TREATED MIN.) - 6' MIN. PENETRATION FOR ALL POSTS GREATER THAN T EXPOSED HEIGHT -4' MIN. PENETRATION FOR ALL POSTS WITH 7' OR LESS EXPOSED HEIGHT - ALL HARDWARE TO BE SS AND ALL LUMBER TO BE P.T. -DECKING WILL BE ATTACHEDwrrH #10 SS DECK SCREW X 3' Environmental OVERALL RAMP CROSS SECTION VIEW Inc.Services, Hibiscus by the Sea I Condominium Association, Inc. 1901 sW Yellowtall Avenue 3830 N Al Port Saint Lucie, FL 34953 Fort Pierce, Florida Phone: 772-215-3997 Fax: 772-879-4520 PIN# 1423-805-0000-000-3 www.dlsenvironmentalservices.com sca.E: 1"=10' 0' 5' 10, GRAPHIC SCALE Paul Welch, Inc. 1984 SW Biltmore Street, 114 Port St. Lucie, FL 34984 / JUN 2 6 2017 Paul Welch, PE No. 29945 JAN 2017 1 SHEET 2 of 4 6' X 6' (AE 2' X 6' P.T. I 2' X 8' P.T. 24' (2) 5/8- SS TH (TYP) 2" X 12" P.T. C -ANOTES•WARE_ BE SS - ALL NEW POSTS TO BE 6' X 6- P.T. POSTS (0.80 CCA TREATED MIN.) - MIN. PENETRATION INTO SAND 0' 1.5' 3' VARIES 4' TO V OR AS NECESSARY TO PROVIDE ADEQUATE BEARING STABILITY m -ALL HARDWARE TO BE SS OR HOG AND ALL LUMBER TO BE P.T. -2' X 6' DECKING NOT ALL SHOWN FOR CLARITY GRAPHIC SCALE) RAMP PLAN VIEW DETAIL Paul Welch, Inc. m Environental 1984 SW Biltmore Street, 114 Hibiscus by the Sea Port St. Lucie, FL 34984 Inc. ervices, Condominium Association, Inc.IQS ��� 2 8 2017 / 1901 SW Yellowtail Avenue 3880 N A1A Port Saint Lucie, FL 34953 Fort Pierce, Florida PIN# 1423-80"000-000-3 Paul Welch, PE No. 29945 Phone: 772-2163997 Fax: 772-879-4520 www.disenvironmentalsemices.com scA�e' 1" = 3' JAN 2017 SHEET 3 of 4 Phone: 772-2153997 Fax: 772-879-4520 www.disenvironmentalservices.com I 5 —�I 2' X 8' P.T. RAIL 2' X 8' P.T. TOF 2' X 6' P.T. MIE (2) Sla' SS THRU BOLTS fIYP) PER POST 2' X 6' P.T. DECKIb 6' X 6' P.T. PO (ABOVE DE 2' X 8' P.T. STRIh 24' O.C. 2' X 12' P.T. CF "'NOTES"' - NEW POSTS TO BE 6' X 6- P.T. POSTS (0.80 CCA TREATED MIN.) - 6' MIN. PENETRATION FOR ALL POSTS GREATER THAN T EXPOSED HEIGHT -4' MIN. PENETRATION FOR ALL POSTS WITH 7' OR LESS EXPOSED HEIGHT - ALL HARDWARETO BE SS AND ALL LUMBER TO BE P.T. - DECKING WILL BE ATTACHED WITH #10 SS DECK SCREW X 3- RAMP CROSS SECTION Environmental VIEW DETAIL Hibiscus by the Sea IncServices, I. Condominium Association, Inc. 1901 SW Yellowtail Avenue 3880 N A1A Port Saint Lucie, FL 34953 Fort Pierce, Florida PIN# 1423-805-0000-0003 0' 1' 2' m Paul Welch, Inc. 1984 SW Biltmore Street #114 Port St. Lucie, FL 34984 JUN 2 8 toil Paul Welch, PE No. 2994 scA E 1"=2' JAN 2017 I SHEET 4 of 4 pbpere°jQ - °. FLORIDA DEPARTMENT OF ENVIRONMENTAL PROTECTION ° Division of Water Resource Management CoastalConstruction Control Line Program. e 2600 Blair Stone Road, M.S. 3522 - Tallahassee, FL 32399-2400 PemritNa. -8033279 _ SL Phone: (850) 245-8336 No. of Pages Attached: 8 FIELD PERMIT PURSUANT TO SECTION 161.053 OR 161.052,.FLORIDA STATUTES FINDINGS OF'FACT AND CONCLUSION OF LAW- The request for a field permit was considered -by the'stalF designee of the Department of Environmental Protection and found to be in compliance with the requirements of Chapter 62B33, Florida Administrative Code (F,A.C.). Approval is specifically limited to tthe activity in the stated location and by the project description, approved plans (if any), attached standard conditions, and any special condi_ti_ons stated below pursuant to Paragraph 161.053(5), Florida Statutes (F.S.). This permit maybe suspended or revoked m accordance with Section 62-4.100, F.A.C. PROJECT LOCATION: .. .. N0070/N0570 of DEP R-21 3880 N. AlA (Hibiscus by the Sea Condominium Association, Inc) Fort Pierce PROJECT DESCRIPTION: -. o �C�3II1 NOV 2.2 2017 BY : ............ y 1�1�ti �t7�iSClt ���. t MOW f sia�s c1iil sl s REA— B Ma. As per attached plan, may extend dune walkovecseaward.and:ramp down to grade: Seaward extension and're-configuration is not to exceed multi -residential dune walkover guideline maximums (6'wide, 6" posts, no further than 10' seaward of vegetation, no concrete): - - - - - - Pagel of4 DEP form73-122 (Updated 5105) ' :Cmdt No.-8033279 - SL SPECIAL PERMIT CONDITIONS: The permit is valid only after all applicable federal, state, and local permits are obtained and does not authorize contravention of local setback requirements or zoning or building codes. This permit and public notice shall be posted on the site immediately upon issuance and shall remain posted along with local approval will the completion of any activity authorized by this permit. Other special conditions of this permit include: Standard field permit conditions and dune walkover guidelines prevail, no lighting is authorized. No additions or modifications w/o prior DEP approval. No work authorized dining marine turtle nesting season (3/1 through 10/31). For additional seaward encroachment, the existing 9'x4' steps are to be removed and allowed to re -vegetate with native dune vegetation. CONDITIONS: The permittee shall comply with the attached standard field permit conditions. APPLICANT INFORMATION: I hereby certify that I am either. (la) the owner of the subject property or (lb) I have the owner's consent to secure this permit on the owner's behalf; and that (2)1 shall obtain any applicable licenses or permits which may be required by federal, state, county, or municipal law prior to commencement of the authorized work; (3) acknowledge th nzed work is what I requ ted; a d (4) I accept responsibility for compliance with all permit conditions. Applicant's Signature Date 11111S/a0/7 Telephone No. ,(O,/Y6 ,��q /� Applicant's Printed Name r'C /V/1 / /./iluy Address .3NO rrt�Y 4,4 YYY,%%%/fM A(c'OVA n`J If applicant is an agent: See above l() Printed name ofproperry owner Property owner's address Property owner's telephone no. DEPARTMENT FINAL ACTION AND FILING AND ACKNOWLEDGMENT: This freldpermit is approved on behalf of the Department of Environmental Protection by the undersigned staff designee, and filed on this date, pursuant to section 120,52, F.S., with the undersigned designated Deputy Clerk, receipt of which is hereby acknowledged. uew7rG SOoa.uan, /Jason A Spanier /11/12/17 StafDesigne.Deputy Clerk Printed Name ofDesignee/Depury Clerk Dare EXPIRATION DATE: 02/28/18 (Emergency permits issued pursuant to Section 62B-33.014, F.A.C., are valid for no more than ninety days and other field permits are valid for no more than 12 months. The staff designee may specify a shorter time limit). EMERGENCY PERMIT: ❑ YES Z NO Approved plans are attached: ZYES ❑ NO Page 2 of 4 DEP form 73-122 (Updated 5105) ....nit No.-8033279 _ SL POST PERMIT AND PUBLIC NOTICE CONSPICUOUSLY ON THE SITE PUBLIC NOTICE The foregoing constitutes final agency action. Any person whose substantial interests are affected by any decision made by the Department on the Field Permit has a right to request an administrative hearing in accordance with the provisions of Sections 120.569 and 120.57, F.S. The request for an administrative hearing must comply with the provisions of Rule 28-106.201, F.A.C., and must be received by the Department (at the address given below) within twenty-one (21) days from the date of this notice. When the Department receives an adequate and timely filed request for hearing, the Department will request the assignment of an administrative law judge. Once the administrative law judge is requested, the Division of Administrative Hearings will have jurisdiction over the formal proceeding and the Department (as the referring agency) will take no further action with respect to the proceeding except as a party litigant. Section 120.54(5)(b)4, F.S., and Rule 28-106.201(2), F.A.C., explain that the following items must be included in a petition for a formal administrative hearing (a) The name and address of each agency affected and each agency's file or identification number, if known; (b) The name, address, any e-mail address, any facsimile number, and telephone number of the petitioner, if the petitioner is not represented by an attorney or a qualified representative; the name, address, and telephone number of the petitioner's representative, if any, which shall be the address for service purposes during the course of the proceedings; and an explanation of how the petitioner's substantial interests will be affected by the agency determination; (c) A statement of when and how the petitioner received notice of the agency decision; (d) A statement of all issues of material fact disputed by the petitioner, or a statement that there are no disputed facts; (e) A concise statement of the ultimate facts alleged, including a statement of the specific facts that the petitioner contends warrant reversal or modification of the Department's action; (f) A statement of the specific rules or statutes the petitioner contends require reversal or modification of the Department's action, including an explanation of how the alleged facts relate to the specific rules or statutes; and (g) A statement of the relief sought by the petitioner, stating precisely the action that the petitioner wants the Department to take with respect to its action. A person may request an extension of time to petition for an administrative hearing. The person filing the request for extension must do so within the time limits for filing a petition described above. The request must state why an extension of time is needed. The Department will grant an extension only when good cause is shown. If a petition or a request for time extension is filed, further order of the Department becomes necessary to effectuate this Field Permit. Accordingly, the Department's final action may be different from the position taken in this notice. Actions undertaken by any person under this permit, pending the lapse of time allowed for the filing of such a request for hearing, may be subject to modification, removal, or restoration. Failure to petition within the allowed time frame constitutes waiver of any right that a person has to request a hearing under Section 120.57, F.S., and to participate as a party to the proceeding. If a legally sufficient petition for hearing is not timely received, this notice constitutes final agency action. When this order becomes final and is filed with the Department Clerk, any party to the order has the right to seek judicial review under Section 120.57, F.S., and Rule 9.030(b)l(c) and 9.110, Florida Rules of Appellate Procedure. A notice of appeal must be filed within thirty (30) days with both the Department Clerk (see address below) and with the appropriate district court of appeal. The notice filed with the district court must be accompanied by the filing fee specified in Section 35.33(3), F.S. Any subsequent intervention will be only by the approval of the presiding officer on motion filed under Rules 28-5.207 or 60Q-2.010, F.A.C. All requests for hearings are to be filed with the Department at the following address: Florida Department of Environmental Protection Office of General Counsel Department Clerk 3900 Commonwealth Boulevard Mail Station 35 Tallahassee, Florida 32399-3000 Page 3 of 4 DEP form 73-122 (Updated 5105) Pe aitNo.-8033279 - SL STANDARD FIELD PERMIT CONDITIONS The following conditions shall apply to FIELD PERhuTS (unless waived by DEP or modified by special permit condition). In the event of a conflict between a field permit condition and a special permit condition, the special condition shall prevail. 1) The permittee shall carry out the construction or activity for which the permit was granted in accordance with the plans and specifications that were approved by DEP as part of the permit. Any deviation there from shall be grounds for suspension of the work and revocation of the permit pursuant to Section 120.60(7), F.S., and may result in assessment of civil fines or issuance of an order to alter or remove the unauthorized structure, or both. No other construction or activities shall be conducted. No modifications to project size, location, or structural design are authorized. A copy of the permit shall be conspicuously displayed at the project site. 2) The permittee shall conduct the construction or activity authorized under the permit using extreme care to prevent any adverse impacts to the beach and dune system, marine turtles and their nests and habitats, or adjacent property and structures. 3) The permittee shall allow any duly authorized member of the staff to enter upon the premises associated with the project authorized by the permit for the purpose of ascertaining compliance with the terms of the permit and with the rules of DEP, until all construction or activities authorized or required in the permit have been completed and the project accepted by DEP. 4) The permittee shall hold and save the State of Florida, DEP, its officers and employees, harmless from any damage (no matter how occasioned and no matter what the amount) to persons or property that might result from the construction or activity authorized under the permit and from any and all claims and judgments resulting from such damage. 5) The permittee shall allow DEP to use all submitted records, notes, monitoring data, and other information relating to construction or any activity under the permit for any purpose it may deem necessary or convenient, except where such use is otherwise specifically forbidden by law. 6) Construction traffic shall not operate and building materials shall not be stored on vegetated areas seaward of the control line, unless specifically authorized by the permit. If (in the opinion of DEP staff) this requirement is not being met, positive control measures shall be provided by the permittee at the direction of DEP staff. Such measures may include temporary fencing, designated access roads, adjustment of construction sequence, or other requirements. 7) The permittee shall not disturb existing beach and dune topography and vegetation except as expressly authorized in the permit. Before the project is considered complete, any disturbed topography or vegetation shall be restored (as prescribed in the permit) with suitable fill material or revegetated with appropriate beach and dune vegetation. 8) The fill material shall be obtained from a source landward of the control line and shall consist of sand which is similar to that already on the site in both grain size and coloration. This fill material shall be free of construction debris, rocks, or other foreign matter. A sample of the sand shall be provided to the staff representative of the Bureau of Beaches and Coastal Systems during the preconstruction conference. 9) If surplus sand fill results from any approved excavation seaward of the CCCL, such material shall be distributed seaward of the CCCL on the site, as directed by DEP staff (unless otherwise specifically authorized by the permit). 10) Any native salt -resistant vegetation destroyed during construction shall be replaced with plants of the same species or, by authorization of DEP, with other native salt -resistant vegetation suitable for beach and dune stabilization. Unless otherwise specifically authorized by the staff, all plants installed in beach and coastal areas (whether to replace vegetation displaced, damaged, or destroyed during construction or otherwise) shall be of species indigenous to Florida beaches and dunes (i.e., sea oats, sea grape, saw palmetto, panic grass, salt meadow hay cord grass, seashore salt grass, and railroad vine). 11) All topographic restoration and revegetation work is subject to approval and acceptance by DEP staff. 12) If not specifically authorized elsewhere in this permit, no operation, transportation, or storage of equipment or materials is authorized seaward of the dune crest or rigid coastal structure during the marine turtle -nesting season. The marine turtle -nesting season is May 1 through October 31 in all counties (except Brevard, Indian River, St. Lucie, Martin, Palm Beach and Broward counties where marine turtle nesting occurs during the period of March 1 through October 31). 13) If not specifically authorized elsewhere in this permit, no temporary lighting of the construction area is authorized at any time during the marine turtle -nesting season and no additional permanent exterior lighting is authorized. 14) This permit has been issued to a specified property owner and is not valid for any other person. Page 4 of 4 DEP form 73-122 (Updated 5105) ' IN 'D,T'A NRIPE DA 66 T:. % L I'E ST. LUCIE COUNTY. 0 �t-f Queens 0 A 7r 4C f h Y f lqq SECTION 23, TOWNSHIP 34 SOUTH, RANGE 40 EAST Env , lriin'mentd Location -Map. Hibiscus by the Sea condominium Association, Inc. Ser,vices, 14P., 3880 N AM 1901 SW Yellowtall Avenue- Fort Pierce; Florida Port Saint Lucia, FL 34953 PIN#--1423-865-0000-000-3 Phone: 772-215-3997 Fax: 7,72-879-4520 v .dlsenvironmentalsewicesxorn SME! N.T.S. JAN.2017 EXISTING 9'X 4' 40• RAMP ADDITION - STAIRS TO BEACH - - SLOPE 8:1 TO BE REMOVED SHOWER f _ AREA 10.5.1 .. .. 92' TO CONDOMINIUM - "`NOTES— _ - PROPOSED WORK IS TO CONSTRUCT TX 40' RAMP ADDITION TO EXISTING BOARDWALK, REMOVE EXISTING STEPS, AND REPLACE RAIL CAP ON EXISTING PLATFORM WITH P.T. 26 X 12- _ -.ALL HARDWARE TO BE SS OR HOG AND ALL LUMBER TO BE P.T. -ALL NEW PILES TO BE 6'0 MARINE PILES- MIN. PENETRATION INTO SAND VARIES 4'.TO6'OR AS NECESSARY TO. PROVIDE ADEQUATE BEARING STABILITY - 0' 29 40' DECK DESIGN LOADS TO MEET 2014 FBC: - - - - - - = WIND LOAD ASP.ER ANSI/ASCE 7-10 SPEED=170 MPH ' EXPOSURE=D.GRAPHIC SCALE .IMPORTANCE FACTOR=1.0- - ` BOARDWALK RAMP ADDITION EII_ vi onmi ellial PLAN VIEW c T Hibiscus Sby the Sea ervices; nC. ' Condominium Association, Inc. - -=-1601SW YellowtaibAvenue-- - . 3880 N A1A Port Saint Lucie, FL 34953 Fort Pierce, Florida Phone: 772-215.7997 Fax: 772-879-0PIN# 1423-805-0000.000-3520 ... w W.dlsenvironmentalservices.com Ste' 1" = 40' . JAN:2017 SHEET 1 of 4 EXISTING _ 40'RAMPADDITION. 10.9 PLATFORM �J 8:1 SLOPE 61- (TVP) -I GRA 2' X 12' P.T. RAIL CAP _f 2' X 8' P.T. RAIL CAP 2" X 8" P.T. TOP RAIL 2° X 6' P.T. MID RAIL 2'X 8" P.T. CROSS -TIES 6' 0 MARINE PILES .(ABOVE DECK) 2°-X 8° P.T. STRINGERS 24- D.C. (MAX.) (2)1/2' CARRIAGE BOLTS - (TYP)'PER PILE .. 2'X6"P.T. DECKING "NOTES"' -NEW PILESTOBE6°0 MARINE PILES 0' 5' 10, - 6' MIN. PENETRATION FOR ALL PILES GREATER THAN T EXPOSED HEIGHT - 4' MIN. PENETRATION FOR ALL PILES WITH 7' OR LESS EXPOSED HEIGHT -ALL HARDWARE TO BE SS OR HOG AND ALL LUMBER TO BE P.T. - GRAPHIC SCALE -DECKING WILL BE ATTACHED WITH #10SSDECKSCREWX3' - OVERALLRAMP Environmental - CROSS SECTION VIEW c T Hibiscus by the Sea - ►J ervices, Inc. Condominium Association, Inc. 1901 SW Yellowtall Avenue-- — - — 3880 N A1A Port Saint Lucle, FL 34953 Fort Pierce, Florida Phone: 772-2154997 Fax: T72-879-4520 PIN# 1423-805-0000-000J www.dlsenvironmentalservices.com - = SME V =10' . JAN:2017 SHEET 2 of 4 (AF 8' O.C. (TYPJ 2' X 6'-P.T. I 2' X 8' P.T. 24' (2) 112' CARRIP (rYP 2' X 8' P.T. C '**NOTES'*' - - ALL NEW PILES TO BE 6'0 MARINE PILES - MIN. PENETRATION INTO SAND VARIES 0. 1.5' 3' 4' TO & OR AS NECESSARY TO PROVIDE ADEQUATEBEARING STABILITY -ALL" HARDWARE TO BE SS OR HDG AND ALL LUMBER TO BE P.T. - -2' X 6' DECKING NOT ALL SHOWN FOR CLARITY _ - GRAPHIC SCALE - DECKING WILL BE ATTACHED WITH #10 SS DECK SCREW 3' - Environmental,:IL4MR PLAN VIEW DETAIL Services, Inc., Hibiscus by the Sea Condominium Association, Inc. 1901-SW-Yellowtall Avenue-- - - - 3880 N A1A Port Saint Lucie, FL 34953 Fort Pierce; Florida PIN# 7423-805-0000-000.3 - Phone: 772-2153997 Fax: 772-879-4520 W .dlsenvironmentalservices.com Sous: JAN,2017 SHEET 3 of 4 5' T X 8' P.T. RAIL 2' X 6' P.T. TOP .2' X 6' P.T. MIC (2) 1/2' CARRIAGE BOLTS (TYP) PER PILE 2'X6'P.T. DECKID 6*0 PI (ABOVE DE 2" X 8" P.T. STRI< 24" O.C. 2'XH' PT-CP -'NOTES'" _ - NEW PILES TO. BEB'H MARINE PILES 12, E01 - 6' MIN. PENETRATION FOR ALL PILES GREATER THAN T EXPOSED HEIGHT F -4'MIN. PENETRATION FOR ALL PILES WITH TOR LESS EXPOSED HEIGHT -.ALL HARDWARE TO BE SS OR HDG AND ALL LUMBER TO BE P.T. GRAPHIC SCALE -DECKING WILL BE ATTACHED WITH #10SSDECKSCREWX3- . ' ' - - - Environment RAMP CROSS SECTION VIEW DETAIL T S Hibiscus by the Sea. ervlces, .nq.. - S1901-SIN Condominium'Association, Inc. . _.-_._ _ - 3880NA1A Port Saint Lucie, FL 34953 _ - Fort Pierce, Florida • - - Phone: 772-215-3997 Fax: 772.879-4520 PIN# 1423-805-0000400-3 www.dlsenvirodmentalservices.com - SC Et 1"=2' JAN2017 SHEET4bf4 T- 40' RAMP ADDITION SLOPE 8:1 1�E 110.5, 92' TO CONDOMINIUM 2 1 �— 5' 9' X 4'.AREA TO BE REPLANTED SHOWER AREA «� N - 0' 20' 40' -NOTES... -AREA OF EXISTING STEPS TO BE REPLANTED WITH SEA OATS(Uniola paniculafa)-(10)1-GALLONPLANTS .. GRAPHIC SCALE Environmental BOARDWALK RAMP ADDITION PLANTING PLAN :S = ' ' Inc, Hibiscus by the Sea . ervices, Condominium Association, Inc. --: - _. 19o1-8WYellowtanAvenue­ 3880N.A1A Port Saint Lucie, FL 34953 Fort Pierce; Florida Phone:.772-2153997 Fax: 772-879-4520 PIN# 1423-805-0000-0003 - - - www.disenvironmentaiservices.com scue . 11 = 40' . JAN 2017 EXHIBIT] N I- 40' RAMP ADDITION SLOPE 8:1 10.5' I 110.5, 92' TO CONDOMINIUM Z� 5' 5' EXISTING 9' X 4' STAIRS TO BEACH TO BE REMOVED SHOWER AREA -NOTES... - PROPOSED WORK IS TO CONSTRUCT F X 40' RAMP ADDITION TO EXISTING BOARDWALK, REMOVE EXISTING STEPS, AND REPLACE RAIL CAP ON EXISTING PLATFORM WITH P.T. TX 12' -ALL NEW HARDWARE TO BE SS AND ALL LUMBER TO BE P.T. -ALL NEW POSTS TO BE 6- X 6- P.T. POSTS (0.80 CCA TREATED MIN.) - MIN. PENETRATION INTO SAND VARIES 4' TO 8' OR AS NECESSARY TO PROVIDE ADEQUATE BEARING STABILITY - DECK DESIGN LOADS TO MEET 2014 FBC: WIND LOAD AS PER ANSVASCE 7-10 SPEED =170 MPH EXPOSURE=D IMPORTANCE FACTOR =1.0 Rs Environment ►S ervices, Inc 1901 SW Yellowtail Avenue Port Saint Lucie, FL 34953 Phone: 772-215-3997 Fax:772-879.4520 www.dlsenvironmentalservices.com 0' 20' 40' GRAPHIC SCALE BOARDWALK RAMP ADDITION Paul Welch, Inc. al PLAN VIEW 1984 SW I iltmore Stre t, #114 Hibiscus by the Sea Port St. Lucie, FL 349 / Condominium Association, Inc. JUN 2 8 2011 3880 N A1A Fort Pierce, Florida Paul Welch, PE No. 2994 PIN# 1423-80MOOO-000-3 sc� 1" = 40' JAN 2017 SHEET 1 of 4 EXISTING 40' RAMP ADDITION 10.5' PLATFORM e. 8:1 SLOPE 2' X 12" P.T. RAIL CAP� 2' X 8' P.T. RAIL CAP — 2' X 8' P.T. TOP RAIL — 2' X 6' P.T. MID RAIL 2° X 12' P.T. CROSS- 6' X 6' P.T. POSTS (ABOVE DECK) 2" X 8° P.T. STRINGERS 24- O.C. (MAX.) (2) 518° SS THRU BOLTS (TYP) PER POST '••NOTES•" 2' X 6° P.T. DECKING - NEW POSTS TO BE 6° X 6° P.T. POSTS (0.80 CCA TREATED MIN.) - 6' MIN. PENETRATION FOR ALL POSTS GREATER THAN 7' EXPOSED HEIGHT -4' MIN. PENETRATION FOR ALL POSTS WITH TOR LESS EXPOSED HEIGHT -ALL HARDWARE TO BE SS AND ALL LUMBER TO BE P.T. -DECKING WILL BEATTACHED WITH #10 SS DECK SCREW X 3' q_sEnvironmental S ervices, Inc. 1901 SW Yellowtail Avenue Port Saint Lucie, FL 34953 Phone: 772-215-3997 Fax: 772-8794520 www.dlsenvironmentalservices.com OVERALL RAMP Hibiscus by the Sea Condominium Association, Inc. 3880 N Al Fort Pierce, Florida PIN# 1423-805-0000-0003 SQM.F 1"=10, ... _� F -.• ,--may 0' 5' 10, GRAPHIC SCALE Paul Welch, Inc. 1984 SW Biltmore Street, 1 Port St`1. Lucie gL,3-4884 ✓ Paul Welch, PE No.0129945 JAN 2017 I SHEET 2 of 4 I 5' I 6' X 6' (AE 2' X 6' P.T. 2' X 8' P.T. 24 (2) 518- SS T} (TYP) 2' X 12' P.T. C "'NOTES— - ALL NEW POSTS TO BE 6' X 6' P.T. POSTS (0.80 CCA TREATED MIN.) - MIN. PENETRATION INTO SAND VARIES 4' TO V OR AS NECESSARY TO PROVIDE ADEQUATE BEARING STABILITY - ALL HARDWARE TO BE SS OR HDG AND ALL LUMBER TO BE P.T. -2'-X 6' DECKING NOT ALL SHOWN FORCLARITY- - DECKING WILL BE ATTACHED WITH 910 SS DECK SCREW x3- 1?s Environmental Services, Inc. 1901 SW Yellowtail Avenue Pon Saint Lucie, FL 34953 Phone: 772-215-3997 Fax: 772-879-4520 www.dlsenvironmentalservices.com RAMP PLAN VIEW DETAIL Hibiscus by the Sea Condominium Association, Inc. 3880 N A1A Fort Pierce, Florida PIN# 1423-805-0000-0003 8' O.C. (TYP.) 0' 1.5' 3' m Paul Welch, Inc. 1984 SW Biltmore Street, #114 Port St. Lucie, FL 34984 JUN 2 8 2011 Paul Welch, PE No. 2994 1"= 3' JAN 2017 1 SHEET 3 of 4 O 2* X 8'P.T �4:(:Hi K1:"z (2) 518- SS THRU B (rYP) PER 2' X 6' P.T. ❑ 6'X6'P (ABC 2' X 8' P.T. 24 2'X 12" 1 5- *-NOTES*- - NEW POSTS TO BE 6' X 6- P.T. POSTS (0.80 CCA TREATED MIN.) 0' 1' 2' - 6' MIN. PENETRATION FOR ALL POSTS GREATER THAN T EXPOSED HEIGHT m -4' MIN. PENETRATION FOR ALL POSTS WITH 7' OR LESS EXPOSED HEIGHT - ALL HARDWARE TO BE SS AND ALL LUMBER TORE P.T. GRAPHIC SCALE - DECKING WILL BE ATTACHED WITH 910 SS DECK SCREW X 3' RAMP CROSS SECTION Paul Welch, Inc. Environmental VIEW DETAIL 1984 SW Biltmore Street, # Inc.Hibiscus by the Sea Port St. Luci F S ervices, ICondominium Association, Inc. j U� 2 hjg984 qS 1901 SW Yellowtail Avenue Port Saint Lucie, FL 34953 Phone: 772-215-3997 Fax:772-879-4520 www.dlsenvironmentalservices.com 3880 N A1A Fort Pierce, Florida PIN# 1423-805-0000-000-3 scu E: 1"=2' Paul Welch, PE No. 29946 JAN2017 I SHEE-r40f4