Loading...
HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCEPlanning & Development Services Department SCANIvt Building & Code Regulations Division pp � 13Y 2300 Virginia Avenue, Fort Pierce, F1.34982 — (772) 46-S55Oe Col Certification for Design Load Compliance Project Name: )tL CJn-+- R PS . a % / ® FT- fit//W/JO"VPOrJItiS Project Address: 9 4ela S OCCAti Da Sy�TIC 5104 �fn5M OPa� Permit#: Occupancy Type: 9: � construction Type: 15 • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o ResidentialAddRlon w/ Any accessory structure requiring a building permit o Any non-residential structure. • Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. `DESIGN CODE: Florida 157& G Code Fifth Edition with 20LL Supplements using ASCE 7-10 2. Structure Designed as (check one). Y%Enclosed _Partially Enclosed _Open 3. Risk Category: _I II _III _ IV Exposure Category: _B C _SLc 4. Design Wind Velocity 12 O mph ASD _LRFD End Zone Width: ft S. Mean Roof Height 519 ft Roof Pitch: o :12 Parapet (Qft 6. Components &�Cladding Design Pressures Used: (PSF, based on 10sgft @ IYMRH, clearly label on all plan openings): Zone 1,g,3 J-7 Zone 2: h Zone 3: -r4&,5 Zone 4: * 2, Zone 5: fP 57 Garage: 7. Design Loads: Floor. ! 2S PSF Roof/Dead: 5512f . PSF Roof/Live. 39 Balcony. a PSF Dock: ll Z& _PSF Deck: /- PSF Stairs: Mai} PSF Fence: & 4- PSF Railings: N I -PSF S. Were Shear Walis'ConsideredFor Structure? Yes �NotApplicable Explain Why Not: PAt. -1aA RvlLlJ rAJG , 9. Is A Continuous Load Path Provided? Yes _Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: __L6±__PSF Soil Test Reports Submitted? �i9-Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT, I certify that to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St Lucie County. I also, eM that structural elements depicted on these plans provide adequate resistance to the design / qc .. l y • I r Company Revised 07AS/2014