Loading...
HomeMy WebLinkAboutEVALUATION REPORTI SCANNED BY St. Lucie County ,,) TRINITY ;ERD 1' . EVALUATION REPORT 7—f EXTERIOR RESEARCH & DESIGN, U.C. Certificate of Authorization #9503 353 CHRISTIAN STREET, UNIT#13 OXFORD, CT 06478 (203)262-9245 Tarco Roofing -STY Et-ILTT-G nlcrrtylnN Evaluation Report 10880.07.08-R9 One Information Way, Suite 225 ST. LUC. C : FL10450-R9 Little Rock, AR 72202 REVIEWED FOR C01A�- SCOPE:, f/.Date of Issuance: 07/11/2008 (254) 913-7750 REVIEWED is ZRevision 9:10/03/2017 DATE PLANS AND PE KIT 1!1iJSTN JOB p i r 2kN§y& ION WILL BE MADE. This Evaluation Report is issued u and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6v' Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Tarco Roof Underlayments LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinitylERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words 'TrinityI ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation RepoHrSt�tgflsRR($R@r3iQRK Prepared by: ARE SUBJECT TO ANY CORRECTfO REQUIRED BY FIELD INSPECTORS THaT MAY BE NNITH AORDER TO LL APPLICABLE CODES. Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 CONCEALED FASTENERS OR ATTACHMENTS ARE THE RESPONSIBILITY OF THE CONTRACTOR OF RECORD The faCumi@ seal apsearung errs authorized by Robert Nieminen, P.E. on 10/0312017. Tb6 does not serve as an elearandelly signed document. CERTIFICATION OF INDEPENDENCE: 1. Trinityl ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinity ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity] ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. Fide Copy vJ TRINITY ERD ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Underlayment Compliance Statement: Tarco Roof Underlayments, as produced by Tarco Roofing, have demonstrated compliance with the following sections of the a Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section 1504.3.1 1507.1.1, T1507.1.1 1507.1.1, T1507.1.1 1507.1.1, T1507.1.1, 1507.2.9.2 1507.2.9.2 1507.2.9.2, FR5A/TRI April 2012 1507-3.3 FRSA/TRI April 2012 3. REFERENCES: Enti ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) PRI (TST5878) Miami -Dade (CER1592) Tarco Roofing UL, L-C. (QUA9625) Property Standard Year Wind Uplift FM 4474 2011 Physical Properties ASTM D226 2009 Physical Properties ASTM D4869 2016 Physical Properties ASTM D1970 2015 Physical Properties ASTM D3909 2012 Physical Properties ASTM D6380 2013 Physical Properties FRSA/TRI April 2012 (04-12) 2012 Physical Properties ASTM D6164 2011 Examination Reference Date FRSA/TRI April 2012(04-12) T33190.08.10 08/06/2010 ASTM D1970 T32530.08.10 08/17/2010 ASTM D1970 T30160.08.09-R1 10/12/2010 FM 4474 T37610.07.11 06/29/2011 ASTM D3909 T40780.04.12 04/06/2012 ASTM 06380 T40790.04.12 04/06/2012 ASTM D6164 T35410.04.12 04/18/2012 ASTM D1970 T45250.04.13-R2 04/23/2013 FRSA/TRI April 2012 (04-12) T43930.09.13-R2 09/11/2013 ASTM D226 & D4869 SC4950.02.14-R2 06/25/2014 ASTM D1970 TAR-SC9480.15 07/02/2015 FM 4474 TAR-SC8020.14 12/03/2015 FM 4474 TAR-SC5670.03.16 03/21/2016 FM 4474 T6460.06.07-R2 05/26/2017 ASTM D226 TAR-SC13965.02.17-R1 05/17/2017 FBC 1507.1.1(Exception) TAR-SC16115.17 10/02/2017 FRSA/TRI April 2012 (04-12) TAR-SC16115.17 10/02/2017 ASTM D1970 BRY-018-02-01 08/11/2003 ASTM D1970 BRY-017-02-01 08/11/2003 ASTM D226 TOT-014-02-02 05/18/2004 ASTM D226 TOT-015-02-02 05/24/2004 ASTM D4869 TOT-009-02-01 09/14/2004 ASTM D4869 TOT-009-02-02 09/14/2004 ASTM D226 TOT-041-02-01 05/24/2006 FBC HVHZ Certification 16-1116.09 01/12/2017 Adhesive compound Affidavit 12/15/2015 Quality Assurance Service Confirmation Exp.06/28/2020 Exterior Research and Design, LLC. Evaluation Report 10880.67.08-119 Certifirnte ofAutharrzo0on#9503 6'"EDITION(2017)FBC NON-HVHZ EVALUATION FL10450-R9 Tarco Roof Underlayments; (254) 913-7750 Revision 9:10/03/2017 Page 2 of 10 TRINITYERD 4. PRODUCT DEscmpTiON: 4.1 Self -Adhering Underlayments: LeakBarrier MS cea ater Armor is a self -adhering, glass mat reinforced, mineral surfaced, SBS I led roof underlayment; meets TM D1970. LeakBarrier P5200Hr Ice and Wate Armor is aself-adhering, glass mat reinforced, fabric surfaced, SBS odified roof underlayment; ASTM D1970 and FRSA/TRI April 2012 (04-12j. Leak ce and Water Armor is a self -adhering, glass mat reinforced, smooth poly film surfaced, SBS modified roof underlayment; meets ASTM D1970. LeakBarrier NR500Hr is a self -adhering, plastic film surfaced, modified underlayment; meets ASTM D1970. LeakBarrier SS400 Ice and Water Armor is a self -adhering, fiberglass reinforced, smooth surfaced modified underlayment; meets ASTM D1970. 4.2 Mechanically Fastened Underlayments: Tarco 1S is an asphalt -saturated organic felt; meets ASTM D226, Type I. Tarco 30 is an asphalt -saturated organic felt; meets ASTM D226, Type 11. Tarco NO 30 is an asphalt -saturated organic felt; meets ASTM D4869, Type IL LeakBarrier EasyLay is an asphalt -coated polyester fabric roof underlayment; meets physical requirements of ASTM D226, Types I and If. 4.3 Mechanically Fastened and/or Bonded Underlayments: Fiberglass Mineral Surfaced Roll Roofing is a glass -fiber -reinforced, asphalt -coated, granule surfaced underlayment used as a valley liner; meets ASTM D3909. ASTM Organic Mineral Surface Tile Underlayment is an asphalt -saturated organic roll roofing sheet; meets ASTM D6380, Class M. LeakBarrier EasyMop' 5BS is a polyester reinforced, SBS modified bitumen roofing underlayment; meets FRSA/TRI April 2012 (04-12). 4.4 Mechanically Fastened Base Sheets: LeakBarrier' EasyLay UDL 15 consists of a woven -polymeric scrim with a textured fabric on the top surface; meets FBC 1507.1.1 (Exception). Within this Evaluation Report, it is used as a base sheet in multi- ply underlayment systems. See FBC File No. FL16884 use as a stand-alone roof underlayment. LeakBarrier EasyLay UDL Basic consists of a woven -polymeric scrim with a textured fabric on the top surface; meets FBC 1507.1.1 (Exception). Within this Evaluation Report, it is used as a base sheet in multi- ply underlayment systems. See FBC File No. FL16884 use as a stand-alone roof underlayment. LeakBarrier EasyLay UDL 50 consists of a woven -polymeric scrim with a non -woven fabric on the top surface and a rubberized polymeric coating on the back surface; meets FBC 1507.1.1 (Exception). Within this Evaluation Report, it is used as a base sheet in multi -ply underlayment systems. See FBC File No. FL16884 use as a stand-alone roof underlayment. 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design, U.C. Evaluation Report 10880.07.08-R9 Certificate o)Authorhation 49503 6" EDITION 12017) FBC NON-HVHZ EVALUATION FL10450-RS Tarco Roof Underlayments; (254) 913-7750 Revision 9: 10/03/2017 Page 3 of 10 a 1 TRINITY I ERD 5.4 Tarco Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable Roof Covers: TABLE I. ROOF COVER OPTIONS Asphalt Wood Shakes Underlayment Shingles Nail -On Tile Foam -On Tile Metal & Shingles Slate LeakBarrier P5200"r s 'ip Y Vest iL Yes Y2Y w krob Yes _lGea Barrier P5200"'u %s; Ye5 Yes[Yes LeakBarrier N11500" LeakBarrier SS400 Yes :u;lF':" b• �'"''`' S� yes H LeakBarrier Easytay VeS: jastiasashee�tsr •:'(anl>aYdshectlh Yes rvi.., ra+'Ye§ a y,,. *-0.:.. I?FAY tern} muh PMsKfeiSh a, =<ee3, ,> u c. ..*.:,•':� LeakBarrier EaryLaY UDL 15 x { UDL Basic or UDL 50 4 Yei (See FLSt�$$a) (ai ti2se sheet In:�(asih8se - sheetirY : � n (See Fl1li88tl} Y (5e�f71688d) , fSee,Ftlt*§� �� Tarco 15 . >..,YeuF. r 'i<.ff" _ .n "`:a.e-N'rv`r- yes Tarco 30 Yes ...,{as TasLaze sheot1�s isase SHee[in y'5✓.: Yes sir �tr' aie Yes' System`(, i-m ulti-ply systeml _.:+. :: .. s-•4.cv.-+}�'; 'C ,,. ::, Tarco NO 30 ok*.,r.r. .,, ='"'ties ,; w.;�:'r1Yes, ,+'.s-r 'VeS'...'.: Fiberglass Mineral Surfaced Lnerpe A Roll Roofing Valley [Y55�„ xF x. f t �• .w f,.. , 15p7 T;9?12r ASTM Organic Mineral Surface Tile Underlayment LeakBarrier EasyMop SBS "iNo- r *YeYr,.T= r17 do g�Yes 5.5.1 Tarco 15, Tarco 30, Tarco NO 30 and Easyl ay may be used as a mechanically attached base layer followed by a LeakBarrier self -adhering top layer or asphalt -applied ASTM Organic Mineral Surface Tile Underlayment or LeakBarrier EasyMop SBS with allowable roof covers noted above for the respective top layer underlayments. 5.5.2 "Foam -On Tile" is limited to use of fallowing Approved the adhesives / underlayment combinations. 1.nf '.,, ;, TABLE lA: ALLOWABLE TnE ADHESIVEf.UIyDERU\YMEMT'L`bMeINA71ON51 ii t Adhesive Florida Product Underlayments Approval I LeakBarrier PS200"T, ASTM Organic Mineral Surface Tile ICP Adhesives Polysete AH-160 FL6332 Underlayment or LeakBarrier EasyMop SBS t Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. Exterior Research and Design, LLC. Evaluation Report 10880.07.08-119 Certificate ofAuthorizetion a95(E6r"EDITION 12017)FBC NON-HVHZ EVALUATION FL10450.R9 Tarco Roof Underlayments; (254) 913-7750 Revision 9:10/03/2017 Page 4 of 10 a TRINITY i ERD 5.6 Allowable Substrates: 5.6.1 Direct -bond to deck: LeakBarrier MS300, LeakBarrier PS200HT, LeakBarrier PS200A4U, LeakBarrier NR500HT or LeakBarrier SS400 self -adhered to: Y New untreated plywood (unprimed or primed with ASTM D41 primer); ➢ Existing plywood (unprimed or primed with ASTM D41 primer); ➢ New or existing OSB (unprimed or primed with ASTM D41 primer); ➢ Structural concrete (unprimed or primed with ASTM D41 primer). Note: Turco does not require priming of new or existing plywood or OSB sheathing. New or existing sheathing should be cleaned of all dirt and debris prior to application of LeakBarrier membranes. ASTM Organic Mineral Surface Tile Underlayment or LeakBarrier EasyMop SBS in hot asphalt to: ➢ ASTM D41 primed structural concrete. Note: Refer to Section 5.6.4 for uplift limitations associated with direct -deck underlayment installations where the overlying roof cover is foam -on the roofing. 5.6.2 Bond to Mechanicaliv Attached Base Sheet LeakBarrier MS300, LeakBarrier P5200"T, LeakBarrier PS2001"u, LeakBarrier NR500HT or LeakBarrier 55400 self -adhered to: ➢ ASTM D226, Type I or II felt; ➢ ASTM D4869 felt; ➢ LeakBarrier EasyLay, LeakBarrier EasyLay UDL 15, LeakBarrier EasyLay UDL Basic or LeakBarrier EasyLay UDL 50. ASTM Organic Mineral Surface Tile Underlayment or LeakBarrier EasyMop SBS in hot asphalt to: ➢ ASTM D226, Type I or If felt; ➢ ASTM D4601, Type II base sheet. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam -on tile systems, base layer shall be attached per minimum requirements of FRSA/TRI April 2012 (04-12), Appendix A, Table 1, or as listed in Section 5.6.4 herein, or as tested in accordance with FBC 1504.3.1. 5.6.3 Bond to Other Substrate Types: LeakBarrier MS300, LeakBarrier PS200"T, LeakBarrier PS200t"u, LeakBarrier NRS00"T or LeakBarrier SS400 self -adhered to ASTM D41 primed metal (flashing metal, valley metal, etc.) 5.6.4 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath foam -on the systems, where the underlayment forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-12), Appendix A, Table 1A or FBC 1609 for determination of design wind loads. #1 Maximum Design Pressure =-75.0 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction Primer: (Optional) ASTM D41 Base Ply: (Optional) LeakBarrier P5200Nu, self -adhered. Underlayment: LeakBarrier P5200"T, self -adhered. Exterior Research and Design, LLC. Evaluation Report 10890.07.08-R9 Certificate ofAuthoraatian a3503 6'.. EDITION (2017)FBC NON-HVHZ EVALUATION FL104SO-R9 Tarco Roof Underlayments; (254) 913-7750 Revision 9: 10/03/2017 Page 5 of 10 "-JTRINITY ! ERD #2 Maximum Design Pressure= -120 0 Dsf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction Primer: (Optional) ASTM D41 Joint Treatment: Plywood joints are covered with 4-inch wide strips of LeakBarrier PS200mu or LeakBarrier EasyBase, rolled into place to create continuous bond Base Ply: (Optional) LeakBarrier PS200mu, self -adhered Underlayment: LeakBarrier PS200W, self -adhered. #3 Maximum Design Pressure = -217.5 osf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional) ASTM D41 Base Ply: (Optional) LeakBarrier PS200mu, self -adhered Underlayment: LeakBarrier P5200n self -adhered. #4 Maximum Design Pressure =-45.0 Dsf*: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Leak8arrier Easylay UDL 15, LeakBarrier EasyLay UDL Basic or LeakBarrier EasyLay UDL 50 (48" wide rolls); See FBC FL16884. Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails and 1-5/8-inch diameter tin caps Spacing: G" o.c. at the 4-inch wide side laps and 8"-a.c. at three (3) equally spaced, staggered center rows. Base Ply: (Optional) LeakBarrier PS200mv, self -adhered Underlayment: LeakBarrier P5200ar, self -adhered. #5 Maximum Design Pressure =-60.0 Dsf: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: LeakBarrier Easylay Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails and 1-5/8-inch diameter tin caps Spacing: 7" o.c. at the 4-inch wide side laps and 7" o.c. at three (3) equally spaced, staggered center rows. Base Ply: (Optional) LeakBarrier PS200mu, self -adhered Underlayment: LeakBarrier PS200a', self -adhered. #6 Maximum Design Pressure = -60.0 osf Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: LeakBarrier EasyLay UDL 15, LeakBarrier EasyLay UDL Basic or LeakBarrier EasyLay UDL 50 (48" wide rolls); See FBC FL16884. Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails and 1-5/8-inch diameter tin caps Spacing: 6" o.c. at the 4-inch wide side laps and 6" o.c. at four (4) equally spaced, staggered center rows. Base Ply: (Optional) LeakBarrier PS200mu, self -adhered Underlayment: LeakBarrier PS200ur, self -adhered. #7 Maximum Design Pressure =-82 5 Dsf• Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: LeakBarrier EasyLay Fasteners: Simplex MAXX Cap Fasteners Spacing: 8" o.c. at the 4-inch wide side laps and 8" o.c. at four (4) equally spaced, staggered center rows. Base Ply: (Optional) LeakBarrier PS200mu, self -adhered Underlayment: LeakBarrier PS200ar, self -adhered. Exterior Research and Design, LLC. Evaluation Report 10880.07.08-R9 Certificate ofAuthoruodon a9503 6'"EDITION (2017)FBC NON-HVH2 EVALUATION FL10450-R9 Tarco Roof Underlayments; (254) 913-7750 'Revision 9: 10/03/2017 Page 6 of 10 TRINITY j ERD #8 Maximum Design Pressure=-120 0 osf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: LeakBarrier EasyLay Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails and 1-5/8-inch diameter tin caps Spacing: 4" o.c. at the 4-inch wide side laps and 4" o.c. at four (4) equally spaced, staggered center rows. Base Ply: (Optional) LeakBarrier P5200mu, self -adhered Underlayment: LeakBarrier PS200"r, self -adhered. 5.6.4.1 All other direct -deck, adhered Tarco underlayment systems beneath foam -on tile systems carry a Maximum Design Pressure of -45 psf. 5.6.4.2 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI April2012 (04-12), Appendix A, Table IA. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WDS, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 5.7 Exposure Limitations: LeakBarrier EasyLay, ASTM Organic Mineral Surface Tile Underlayment and LeakBarrier EasyMop SIBS shall not be left exposed for longer than 180-days after installation. LeakBarrier PS200"rshall not be left exposed for longer than 120-days after installation. LeakBarrier MS300, N11500H1, PS200mU or SS400 shall not be left exposed for longer than 30-days after installation. Tarco 1S, Tarco 30 and Tarco NO 30 shall be covered as soon as possible after installation; exposure for more than 24 hours after installation could adversely affect performance. 5.8 Tile Slippage Limitations (TAS 103 Per FRSA/TRI April 2012 (04-12)): When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. r.. .,. �. TABLE2: T1LE�L1PPA" ., ,a vM L t LIfJIFiA'Tf,O,NS tONDIRECT'-DECK TfI.�INSTALtATIOf4�3• _. ;. � :,.,: ;.;. Underlayment Tile Profile Staging Method Maximum Slope LeakBarrier PS200"' Flat 10-tile stack or 6-tile stack (4 over 2) 6:12 Lugged 6-tile stack (4 over 2) 6:12 LeakBarrier EasyMop SB6 Flat 6-tile stack (4 over 2) 5:12 Lugged 6-tile stack (4 over 2) 6:12 Exterior Research and Design, U.C. Evaluation Report 10880.07.08-R9 re"cute ofAuthornotion 09503 6" EDITION (20171 FBC NON-HVHZ EVALUATION FL10450.R9 Tarco Roof Underlayments: (254) 913-7750 Revision 9:10103/2017 Page 7 of 10 8 . 0 i �1 TRINITY i ERD 6. INSTALLATION: 6.1 Tarco Roof Underlayments shall be installed in accordance with Tarco Roofing published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if applicable). ® ,2=fir LeakBarner. MS30_0„PSf00 ,PS200 ,NRSQO dr 5S4Uq'fceand%ii(ater 6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. 6.3.2 Non -Tile Applications: Cut to manageable sections and allow to relax prior to application. Membrane Application: 0, Place a full width piece on the prepared substrate, aligned parallel to the eave edge and extend approximately 3/8" over the eave and rake with the selvedge edge positioned upslope. ➢ Fold back the upslope half of the sheet and remove the exposed release film, taking care not to displace the membrane A Working from the centerline out, roll the membrane onto the substrate, taking care to avoid wrinkles and ridges Y Apply a 1/16" thick layer of asphalt plastic cement over the eave and rake metal, extending 2" to 3" onto the deck surface. ➢ Fold back the downslope half of the sheet, remove the release film and roll the membrane onto the substrate from the centerline out. ➢ Seal all 6" end laps with a 1/16" thick application of asphalt plastic cement and stagger all end laps minimum 36". ➢ Remove selvage release film, if present, and install second and subsequent courses in a similar manner. �;- Install capped or tin -tagged nails 6" o.c. along the centerline of the laps. ➢ At all T-joints, where an end -lap and the next overlapping course intersect, apply a bead of roofing laps cement before the overlapping course is laid. ➢ Roll the entire surface with a weighted roller, paying particular attention to side laps, end laps and eave / rake areas to ensure a complete bond. 6.3.3 Tile Applications (PS200"ronly): Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted above as a guideline. Wait a minimum of 24 hours prior to loading roof tiles. For mechanically fastened tile roofing over 2-ply system, consisting of Base Sheet and self -adhering top sheet(s), Base Sheet fastening shall be not less than FRSA/TRI April 2012 (04-12), Table 1. For adhesive -set tile applications, refer to Section 5.6.4 herein. Refer to Section 5.8 for tile staging limitations. If tiles are to be left in a staged condition for more than 30 days, Tarco Roofing requires tiles be staged two tiles perpendicular to slope, four tiles on top, parallel to slope, regardless of the allowance in Section 5.8. 6.3.4 Multi -Ply Underlavment Systems: LeakBarrier® SS400 Ice and Water Armor followed by LeakBarrier® SS400 Ice and Water Armor (direct -to - deck per 5.6.1 or over mechanically attached base sheet per 5.6.2) is allowable for use under mechanically attached prepared roof systems. Limits of use are those associated with the top -layer material. This is not a requirement, but is allowable if a multi -ply underlayment system is desired. Exterior Research and Design, LLC. Evaluation Report 10880.07.08-R9 Certificate o7AutholuoNun x9909 eEDRION(2017) FBC NON.HVHZ EVALUAnoN FL10450-R9 Tarco Roof Underlayments; (Z54) 913-7750 Revision 9:10103/2017 Page 8 of 10 / J `�i TRINITY ERD �_.Tar2o 5'ati0,30 6.4.1 Non -Tile Applications: Shall be installed in compliance with the codified requirements for ASTM D226, Type I (Tarco 15) or ASTM D226 Type II (Tarco 30) underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. 6.4.2 Tile Applications (Tarco 30 only]_ Tarco 30 is limited to use as a mechanically attached base sheet in the "Two Ply System' from FRSA/TRI April 2012 (04-12). Reference is made to Table 1 herein, coupled with FRSA/TRI April 2012 (04-12) Installation Manual. ;i 6.5.1 Shall be installed in compliance with the codified requirements for ASTM D4869, Type II underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. 6.6.1 Shall be installed in compliance with the codified requirements for ASTM D226, Type II underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. 6.6.2 Non -Tile Applications: Place a full width section of EasyLay, parallel to the eave edge of the roof and unroll 2 to 3 feet with the lay lines facing up, and position to the edge of the eave and rake. Install a few fasteners at the top, near the rake, and roll out the sheet to a manageable length. Pull, straighten and align the sheet so that any wrinkles are eliminated and the sheet is even with the eave edge. Fasten with 3/8" headed roofing nails or 1" capped (plastic or metal) nails, driven by hand or pneumatically, spaced 6" o.c. at all laps in the center of the seam area, and two staggered rows fastened 12" o.c. in the field of the sheet. Install nails such that the head of the nail is flush with the surface, without cutting into the surface. Fasten from the top to avoid walking or kneeling on unsecured sheet. Continue to the end of the substrate and fasten down. Align the next roll over the preceding sheet so as to form a minimum 4", water -shedding lap, and install per instructions above. Apply subsequent sheets in the same manner, with minimum 4" water -shedding laps and minimum 8" end -laps, which are staggered minimum 36" fro the preceding course. For double layer applications, follow the instructions noted above, but using a minimum 19", water - shedding side lap. Allow for minimum 6" up the vertical transitions and minimum 6" over hips and ridges. At valleys, first install a vertical length of EasyLay down the center of the valley, then start at the low point and work to the high point, rolling the membrane from the center outward in each direction, ensuring no wrinkles or tears. Covered with valley -metal or other valley lining material in accordance with NRCA recommendations. Apply a thin coat of asphalt plastic cement to waterproof areas where any cuts or tears have occurred. Seams or joints that require adhesive or sealant can be treated with high quality plastic cement (asbestos free). 6.6.3 Tile- Applications base layer in multi -ply system: LeakBarrier EasyLay is limited to use as a mechanically attached base sheet in the "Two Ply System" from FRSA/TRI April 2012 (04-12). Reference is made to Table 1 and Section 5.6.4 herein, coupled with FRSA/TRI April 2012 (04-12) Installation Manual Exterior Research and Design, I.I.C. Evaluation Report 10880.07.08-R9 Cer;Pwte of Authorization#99a3 EDITION (2017) FBC NON-HVHZ EVALUATION FL10450-R9 Tarco Roof Underlayments; (254) 913-7750 Revision 9:10/03/2017 Page 9 of 10 8. PA i �yJ TRINITY 1 ERD 6.7.1 Shall be installed in compliance with current Tarco Roofing published installation requirements. For use in tile applications: ASTM Organic Mineral Surface Tile Underlayment and LeakBarrier'"' EasvMop SBS are for use as an alternate to "Mineral Surface Roll Roofing' (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TR1 April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems. 6_8 Tile Staging: 6.8.1 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. Refer to Table 2 herein, and Tarco Roofing published requirements for tile staging. 6.8.2 Battens and/or Counter -battens, as required by the tile manufacturer and FRSA/TRI April 2012 (04-12) must be used on all roof slopes greater than 7:12. Precautions should be taken as needed, such as the use of battens or nail -boards, to prevent tile sliding and/or damage to the underlayment during the loading process- 6.8.3 Tarco Roofing specifies the minimum cure time after installation of self -adhering membranes and before loading of roofing tiles is forty-eight (48) hours. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. MANUFACTURINGPLANTS: Contact the noted QA agency for information on product locations covered for F.A.C. 61G20-3 CA requirements. The following plants have qualified products under their respective physical properties specifications. Pliant- 35'beuflcanbH;;;; ,, products a ASTM ASTM D226 LeakBarrier EasyLay, Tarco 15, Tarco 30 ASTM D4869 Tarco NO 30 ASTM D3909 Fiberglass Mineral Surfaced Roll Roofing Greencastle, ASTM D6380 ASTM Organic Mineral Surface Tile Underlayment PA ASTM D1970 LeakBarrier MS300 Ice and Water Armor, LeakBarrier PS200 Ice and Water Armor, LeakBarrier SS400 Ice and Water Armor ASTM D1970 & FRSA/TRI 04-2012 LeakBarrier PS200 Ice and Water Armor FRSA/TRI 04-2012 LeakBarrier EasyMop"' SBS ASTM D226 LeakBarrier EasyLay, Tarco 15, Tarco 30 ASTM D4869 Tarco NO 30 Belton, TX ASTM D1970 LeakBarrier MS300 Ice and Water Armor, LeakBarrier PS200 Ice and Water Armor, LeakBarrier 55400 Ice and Water Armor ASTM D1970&FRSA/TRI 04-2012 LeakBarrier PS200 Ice and Water Armor Coshocton, OH ASTM D1970 LeakBarrier NR500 Gujarat, India FBC 1507.1.1 {Exception) LeakBarrier EasyLay Ea UDL 15, LeakBarrier syLay UDL Basic, LeakBarrier' EasyLay UDL 50 QUALITY ASSURANCE ENTITY: UL, LLC. — QUA9625; (847) 664-3281 END OF EVALUATION REPORT - Exterior Research and Design, I.I.C. Evaluation Report 10880.07-08-R9 Cenifmte.fAuthoriurtfo"N950a 6" EDITION (2027)FSCNON-HVHZ EVALUATION F1.10450-R9 Tarco Roof Underlayments; (254) 913-77511 Revision 9: 10/03/2017 Page 10 of 10